1.
Sleep Breath ; 28(1): 221-230, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37542679

RESUMO

BACKGROUND: Breathing-synchronized hypoglossal nerve stimulation (HNS) is routinely used as an alternative treatment for patients with obstructive sleep apnea (OSA). Significant and clinically relevant improvements in disease severity and OSA symptoms such as daytime sleepiness as well as overall quality of life have been reported in randomized-controlled trials and large real-world cohort studies. However, so far, few data exist on patient-reported experience with the treatment. METHODS: A structured survey with 22 questions was constructed using five-level Likert scales (1 = no agreement, 5 = complete agreement) to evaluate patient experience with HNS and perception of the treatment in the domains "Overall experience with therapy," "Experience with treatment process," and "Side-effects from treatment." Additional data were collected on current symptom status, measured with Epworth sleepiness scale (ESS) questionnaire, and OSA disease history. Multiple linear regression analysis was conducted to test associations of medical variables and response behavior. Correlations between variables and domains, as well as individual items, were assessed using Spearman rank test. RESULTS: A total of 75 patients from Germany who were treated with breathing-synchronized HNS were enrolled (mean age 57.3 years, 78% male), and 71 questionnaires with complete data were included for analysis. Two-thirds of participants (67%) had a history of OSA history for 5 years or longer. Of all patients, 76% had normalized OSA symptoms at time of the study (ESS: 6.4 ± 5.0) and 98% reported using stimulation therapy every night. Regression analysis revealed an association of current symptoms measured with ESS and response behavior. Hence, patients with normalized daytime sleepiness reported significantly more positive experience across all domains assessed, compared to patients with residual daytime sleepiness. Overall, only 2% of participants reported side effects that made them reduce or discontinue stimulation therapy. The rate of reported side effects was associated with current symptom control under therapy. CONCLUSIONS: Overall patient-reported experience with breathing-synchronized HNS therapy was positive and high satisfaction with the treatment process was observed. Side effects occurred, but rarely affected subjective use of the therapy or satisfaction. Subjective experience and perception are influenced by residual daytime sleepiness with stimulation therapy.


Assuntos
Distúrbios do Sono por Sonolência Excessiva , Apneia Obstrutiva do Sono , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Nervo Hipoglosso , Qualidade de Vida , Distúrbios do Sono por Sonolência Excessiva/complicações , Medidas de Resultados Relatados pelo Paciente
2.
Eur Arch Otorhinolaryngol ; 280(10): 4627-4639, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37354340

RESUMO

INTRODUCTION: Hypoglossal nerve stimulation (HNS) has recently been introduced as an alternative treatment for patients with OSA. A large number of studies have demonstrated substantial changes in OSA with this therapy by reducing respiratory events and improving symptoms such as daytime sleepiness and quality of life. The objective of this review was to conduct a systematic review and meta-analysis to evaluate patient-reported outcomes and experience with HNS therapy. METHODS: A systematic literature search of MEDLINE, Cochrane, and Web of Science was performed to identify randomized controlled and observational studies reporting subjective outcomes with different HNS systems in patients with OSA. Abstracts of 406 articles were screened and a subset of 55 articles were reviewed for eligibility. Risk of bias was assessed using the ROBINS-I tool. Meta-analysis using RevMan was performed when > 2 studies were identified that reported data on a specific outcome. RESULTS: Thirty-four publications reporting data on 3785 patients with a mean follow-up of 11.8 ± 12.2 months were identified and included in the meta-analysis. The analysis revealed a pooled effect of 4.59 points improvement in daytime sleepiness as measured by the ESS questionnaire (Z = 42.82, p < .001), 2.84 points improvement in daytime functioning as measured by the FOSQ score (Z = 28.38, p < .001), and 1.77 points improvement in sleep quality as measured by the PSQI questionnaire (Z = 2.53, p = .010). Patient-reported experience was consistently positive and revealed additional relevant aspects from this perspective. CONCLUSION: HNS therapy significantly improves quality of life in patients with OSA and reliably produces clinically meaningful effects on daytime sleepiness, daytime functioning, and sleep quality. Treatment regularly meets or exceeds the minimum clinically important differences defined for the respective instruments. Additional research is needed to further investigate effects on quality of life beyond improvements in daytime sleepiness and daytime functioning.


Assuntos
Terapia por Estimulação Elétrica , Nervo Hipoglosso , Apneia Obstrutiva do Sono , Humanos , Apneia Obstrutiva do Sono/cirurgia , Medidas de Resultados Relatados pelo Paciente , Qualidade de Vida
3.
J Chem Phys ; 158(10): 101101, 2023 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-36922145

RESUMO

The probability per unit time for a thermally activated Brownian particle to escape over a potential well is, in general, well-described by Kramers's theory. Kramers showed that the escape time decreases exponentially with increasing barrier height. The dynamics slow down when the particle is charged and subjected to a Lorentz force due to an external magnetic field. This is evident via a rescaling of the diffusion coefficient entering as a prefactor in the Kramers's escape rate without any impact on the barrier-height-dependent exponent. Here, we show that the barrier height can be effectively changed when the charged particle is subjected to a vortex flow. While the vortex alone does not affect the mean escape time of the particle, when combined with a magnetic field, it effectively pushes the fluctuating particle either radially outside or inside depending on its sign relative to that of the magnetic field. In particular, the effective potential over which the particle escapes can be changed to a flat, a stable, and an unstable potential by tuning the signs and magnitudes of the vortex and the applied magnetic field. Notably, the last case corresponds to enhanced escape dynamics.

4.
J Chem Phys ; 157(4): 044902, 2022 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-35922352

RESUMO

The chain walking (CW) polymerization technique has the unique property of a movable catalyst synthesizing its own path by creating branch-on-branch structures. By successive attachment of monomers, the resulting architecture ranges from dendritic to linear growth depending on the walking rate, which is defined by the ratio of walking steps and reaction events of the catalyst. The transition regime is characterized by local dendritic sub-structures (dendritic blobs) and a global linear chain feature forming a dendritic bottle-brush. A scaling model for structures obtained by CW catalysis is presented and validated by computer simulation relating the extensions of CW structures to the catalyst's walking ability. The limiting case of linear (low walking rate) and dendritic growth (high walking rate) is recovered, and the latter is shown to bear analogies to the Barabási-Albert graph and Bernoulli growth random walk. We could quantify the size of the dendritic blob as a function of the walking rate by using spectral properties of the connectivity matrix of the simulated macromolecules. This allows us to fit the numerical constants in the scaling approach. We predict that independent of the underlying chemical process, all CW polymerization syntheses involving a highly mobile catalyst ultimately result in bottle-brush structures whose properties depend on a unique parameter: the walking rate.


Assuntos
Dendrímeros , Catálise , Simulação por Computador , Dendrímeros/química
5.
OTO Open ; 6(3): 2473974X221109794, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35832353

RESUMO

Objective: Unilateral hypoglossal nerve stimulation (uniHNS) is an effective treatment for obstructive sleep apnea. Bilateral hypoglossal nerve stimulation (biHNS) is a novel therapeutic option and a different approach to hypoglossal nerve stimulation. The aim of this study was to analyze the clinical outcome of the first 10 biHNS cases vs the first 10 uniHNS cases ever implanted. Study Design: Prospective data analysis. Setting: International multicenter comparative clinical trial. Methods: The first 10 patients in 2020 who received a biHNS device (Genio System; Nyxoah) and the first 10 patients in 2014 who received a uniHNS system (Inspire II; Inspire Medical Systems) were included. Treatment outcome was evaluated at 3 months after surgery. Data collection included demographics, apnea hypopnea index (AHI), oxygen saturation and desaturation index, Epworth Sleepiness Scale, and adverse events. Results: The mean ± SD age was 52.1 ± 9.6 years (biHNS) and 58.3 ± 8.6 years (uniHNS). The mean body mass index was 26.4 ± 5.6 kg/m2 (biHNS) and 26.2 ± 2.2 kg/m2 (uniHNS). The mean preimplantation AHI (biHNS, 39.9 ± 14.8/h; uniHNS, 32.2 ± 11.0/h) decreased in both groups after 3 months (biHNS, 19.2 ± 14.0/h, P = .008; uniHNS, 13.1 ± 16.8/h, P = .037) with no significant difference between groups (P = .720). The mean preimplantation Epworth Sleepiness Scale (biHNS, 11.8 ± 6.2; uniHNS, 11.1 ± 4.9) decreased as well after 3 months (biHNS, 9.4 ± 6.3; uniHNS, 6.0 ± 5.0). Conclusion: Preliminary postmarket data suggest that biHNS may be as safe and effective as uniHNS. Long-term follow-up in a larger sample size is required to assess the stability of biHNS.

6.
Sleep Med ; 95: 55-75, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35567880

RESUMO

BACKGROUND: Obstructive sleep apnea (OSA) has been linked to multiple co-morbidities, and some research points to a potential relationship between OSA and hearing and balance dysfunction, and the benefits of continuous positive airway pressure (CPAP) treatment. OBJECTIVE: The present study was undertaken as a scoping review of research on OSA and its impact on hearing and balance function in adults and children and whether the treatment of CPAP would affect hearing and balance function. METHOD: Online databases were used to identify 45 papers published that used hearing and balance assessments concerning OSA and CPAP therapy as a primary outcome. The secondary outcome was the subjective perception through validated questionnaires. RESULTS: Whilst the data on the effect of OSA on middle ear function remains inconclusive, most papers demonstrate an increase in hearing thresholds, an absence of otoacoustic emissions (OAE) and delayed auditory brainstem response (ABR) in adults with OSA. Nystagmus and abnormal vestibular evoked myogenic potentials (VEMPs) were observed in the small number of papers. The positive pressure from CPAP significantly and transiently increases middle ear pressure, however, its effects on other auditory regions and the vestibular system remains inconclusive. Research on hearing and balance function in children with OSA is limited. CONCLUSIONS: Narrow assessments of hearing and balance are not sufficient to understand the nature of hearing and balance function in OSA patients and the effect of CPAP therapy. More comprehensive assessments are necessary to observe peripheral and central changes in the auditory and vestibular pathways.


Assuntos
Apneia Obstrutiva do Sono , Adulto , Criança , Comorbidade , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Audição , Humanos , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/terapia , Inquéritos e Questionários
7.
Sleep Breath ; 26(4): 1673-1681, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34970703

RESUMO

PURPOSE: In patients with a high pre-test probability of suffering from obstructive sleep apnea (OSA), (cardio)-respiratory polygraphy (RP; level 3) is commonly used for home sleep testing (HST); however, testing based on peripheral arterial tonometry (PAT) is increasingly recognized as an alternative method. The aim of the study was to compare sleep position, patients' comfort, and technical failure rates of HST with RP and PAT in patients with suspected OSA. METHODS: Sleep position, patients' comfort, and technical failure rates of RP and PAT were compared in 56 patients receiving two nights of HST with either RP or PAT in a randomized fashion. RESULTS: Time in supine position with PAT was significantly lower (173.7±88 min) compared to RP (181.7±103.7 min; p < 0.001), although the absolute mean difference was not clinically significant. Patients reported to sleep better, feeling less disturbed when falling asleep, losing less sensors, and fewer nightly awakenings with PAT, but experienced more pain at the side of the finger probe. Forty-five out of 56 patients (80%) rated PAT as being the superior sleep test and 49 out of 56 (88%) would prefer PAT for further investigations (p<0.001). PAT testing was associated with less technical failures. CONCLUSION: The results demonstrate that HST with PAT leads to less time in supine sleep positioning, which may be clinically relevant in selected patients. Moreover, PAT is associated with less technical failures and is perceived with less discomfort during testing and a reduced number of nocturnal awakenings in patient self-reports.


Assuntos
Conforto do Paciente , Apneia Obstrutiva do Sono , Humanos , Polissonografia/métodos , Apneia Obstrutiva do Sono/diagnóstico , Sono , Manometria/métodos , Decúbito Dorsal
8.
Eur Arch Otorhinolaryngol ; 278(9): 3351-3356, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33538874

RESUMO

BACKGROUND: Patients with recurrent epistaxis, particularly due to hereditary hemorrhagic telangiectasia (HHT) are recommended to apply topical tranexamic acid (TXA) to reduce bleeding events. Those patients may suffer ciliary dysfunction due to TXA's effects on ciliary beating frequency (CBF) and their consequences. METHODOLOGY/PRINCIPAL: Human nasal epithelial cells were harvested with a nasal brush in 30 healthy subjects. We investigated the CBF in RPMI medium using high-frequency video microscopy. TXA was added to the cells in various concentrations ranging from 2 to 5%, including the therapeutic concentration (2%) and a control (0%). RESULTS: CBF in the control condition was 6.1 ± 1.6 Hz. TXA reduces CBF in a time and concentration dependent manner, to, e.g. 4.3 ± 1.2 Hz with 2% TXA and 3.3 ± 0.9 Hz with 5% TXA after 16-20 min. The differences in CBF were statistically significant for all concentrations of TXA. CONCLUSIONS: TXA has the potential to significantly impair nasal epithelial function. Therefore, frequent or regular topical nasal application of TXA should be done under close monitoring of nasal function, especially in patients with co-morbidities like chronic rhinosinusitis.


Assuntos
Ácido Tranexâmico , Cílios , Epistaxe , Células Epiteliais , Humanos , Mucosa Nasal , Ácido Tranexâmico/farmacologia
9.
BMC Med Educ ; 21(1): 31, 2021 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-33413342

RESUMO

BACKGROUND: Primary care physicians are at the very heart of managing patients suffering from multimorbidity. However, several studies have highlighted that some physicians feel ill-equipped to manage these kinds of complex clinical situations. Few studies are available on the clinical reasoning processes at play during the long-term management and follow-up of patients suffering from multimorbidity. This study aims to contribute to a better understanding on how the clinical reasoning of primary care physicians is affected during follow-up consultations with these patients. METHODS: A qualitative research project based on semi-structured interviews with primary care physicians in an ambulatory setting will be carried out, using the video stimulated recall interview method. Participants will be filmed in their work environment during a standard consultation with a patient suffering from multimorbidity using a "button camera" (small camera) which will be pinned to their white coat. The recording will be used in a following semi-structured interview with physicians and the research team to instigate a stimulated recall. Stimulated recall is a research method that allows the investigation of cognitive processes by inviting participants to recall their concurrent thinking during an event when prompted by a video sequence recall. During this interview, participants will be prompted by different video sequence and asked to discuss them; the aim will be to encourage them to make their clinical reasoning processes explicit. Fifteen to twenty interviews are planned to reach data saturation. The interviews will be transcribed verbatim and data will be analysed according to a standard content analysis, using deductive and inductive approaches. CONCLUSION: Study results will contribute to the scientific community's overall understanding of clinical reasoning. This will subsequently allow future generation of primary care physicians to have access to more adequate trainings to manage patients suffering from multimorbidity in their practice. As a result, this will improve the quality of the patient's care and treatments.


Assuntos
Multimorbidade , Médicos de Atenção Primária , Raciocínio Clínico , Humanos , Pesquisa Qualitativa , Encaminhamento e Consulta
10.
Sleep Breath ; 25(2): 1011-1017, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32623557

RESUMO

STUDY OBJECTIVES: Snoring is a common phenomenon which is generated by vibration of soft tissue of the upper airway during sleep. Due to the high incidence of isolated snoring and the substantial burden for the patient and the bed partner, a thorough examination and appropriate therapy are required. Many recommendations for the treatment of isolated snoring are either not evidence-based or are derived from recommendations for the management of obstructive sleep apnea. Therefore, the aim of this study is the identification and description of open questions in the diagnosis and treatment of isolated snoring and the illustration of areas for further research. METHODS: In the context of the development of the new version of the German guideline "Diagnosis and treatment of isolated snoring in adults," a multidisciplinary team of experts performed a systematic literature search on the relevant medical data and rated the current evidence regarding the key diagnostic and therapeutic measures for snoring. RESULTS: The systematic literature review identified 2293 articles. As a major inclusion criterion, only studies on primary snoring based on objective sleep medical assessment were selected. After screening and evaluation, 33 full-text articles remained for further analysis. Based on these articles, open questions and areas for future research were identified for this review. CONCLUSION: Several major gaps in the literature on the diagnosis and treatment of isolated snoring were identified. For the majority of diagnostic and therapeutic measures for snoring, high-level scientific evidence is still lacking.


Assuntos
Ronco/diagnóstico , Ronco/terapia , Pesquisa Biomédica , Previsões , Humanos
11.
Eur Arch Otorhinolaryngol ; 278(3): 893-900, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33111155

RESUMO

BACKGROUND: Obstructive sleep apnea (OSA) is a sleep disorder with a prevalence of 9-38%. The underlying pathology in OSA is a collapse of the upper airway. Especially in more severely affected patients, this collapse is often located at the level of the tongue base. Therefore, various implantable systems (anchors and ligament techniques) were developed to prevent or overcome this collapse. These systems are exposed to various forces. Different models have been developed to measure these forces and data comparing forces in healthy individuals with OSA patients are rare. PURPOSE: Purpose of the study was to evaluate possible differences in tongue forces between healthy individuals and patients with OSA. METHOD: To evaluate maximum isometric tongue forces, we conducted a matched pair design study including 20 healthy individuals and 20 patients suffering from OSA. Maximum isometric tongue forces were measured in an anterior/posterior direction with the help of self-designed new device that clamps the tongue. RESULTS: We could show that the maximum isometric force does not differ significantly in healthy individuals (10.7 ± 5.2N) from patients with OSA (14.4 ± 6.3N). CONCLUSION: Currently there are no indications that maximum isometric tongue force does differ in healthy individuals and patients with OSA. Higher, as well as lower, tongue forces in patients with OSA seem not to differ from healthy subjects and therefore may not be needed to consider, in the development of tongue management devices, for OSA patients.


Assuntos
Apneia Obstrutiva do Sono , Voluntários Saudáveis , Humanos , Língua
12.
In Vivo ; 34(6): 3285-3289, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33144435

RESUMO

BACKGROUND/AIM: Cocaine is a widely used recreational drug and is known for its nasal complications including epithelial, cartilage and bone damage. The aim of the study was to analyze the impact of cocaine on ciliary beat frequency (CBF) of human nasal epithelial cells and therefore better understand its side effects on nasal mucosa. MATERIALS AND METHODS: Nasal epithelial cells of 21 healthy subjects were harvested and exposed in vitro to cocaine hydrochloride solutions ranging from 0.875% to 7%. High-speed video footage was acquired with phase contrast microscopy and CBF was analyzed with Sissons-Ammons Video Analysis (SAVA) software. RESULTS: All tested concentrations led to a significant reduction in CBF compared to the control. Effects increased over time and with concentration. A mechanical inhibition of cilia by cocaine crystals was also observed. CONCLUSION: We assume that CBF reduction is part of the pathomechanism leading to nasal complications in cocaine abuse. Considering these results, clinical usage of cocaine should be critically evaluated and restricted to select cases only.


Assuntos
Cocaína , Contagem de Células , Cílios , Cocaína/farmacologia , Células Epiteliais , Humanos , Mucosa Nasal
13.
Anticancer Res ; 40(11): 6195-6203, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33109556

RESUMO

BACKGROUND: Head and neck squamous cell cancer (HNSCC) affects the oral cavity and the pharynx. The aim of the study was to investigate the effects of selective tyrosine kinase inhibitors (TKIs) erlotinib, gefitinib, nilotinib and dasatinib and the mammalian target of rapamycin (mTOR) inhibitor everolimus on the expression of apoptosis-related proteins caspase-3, FAS cluster of differentiation (CD)-95 and FAS ligand in human papilloma virus (HPV)-dependent squamous cancer. MATERIALS AND METHODS: Two HPV-negative cell lines (UMSCC-11A/-14C) and one HPV-positive cell line (CERV196) were incubated with TKIs or everolimus and protein concentrations of target proteins were analyzed with enzyme-linked immunosorbent assay (ELISA). RESULTS: Caspase-3 was affected by the tested TKIs in HPV-positive SCC, whereas FAS CD95 and FAS ligand were influenced in HPV-negative SCC. DISCUSSION: This is the first study to analyze the influence of TKIs and everolimus on key proteins of apoptosis. Our results provide novel information contributing to a better understanding of the cell biology of HPV-dependent HNSCC and might contribute to the discovery of novel pharmaceutical treatment strategies for HNSCC.


Assuntos
Proteínas Reguladoras de Apoptose/metabolismo , Everolimo/farmacologia , Papillomaviridae/fisiologia , Inibidores de Proteínas Quinases/farmacologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/metabolismo , Carcinoma de Células Escamosas de Cabeça e Pescoço/virologia , Caspase 3/metabolismo , Linhagem Celular Tumoral , Proteína Ligante Fas/metabolismo , Humanos , Proteínas de Neoplasias/metabolismo , Papillomaviridae/efeitos dos fármacos , Receptor fas/metabolismo
14.
Laryngoscope Investig Otolaryngol ; 5(2): 326-329, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32337364

RESUMO

BACKGROUND: Upper Airway Stimulation (UAS) is a well-established therapy option for obstructive sleep apnea (OSA). AIMS: There are no data on whether respiratory sensing contributes to successful UAS therapy. MATERIALS & METHODS: After initial measurements of 3 implanted patients (M1), the sensing signal was inverted (M2) without changing other parameters. Two weeks later, the signal was converted back again, and the sensitivity of breathing cycle detection was turned to a very low state (M3). RESULTS: At M2 and M3, the apnea-hypopnea index and oxygen desaturation index increased. DISCUSSION: Correct respiratory sensing is important for controlling OSA using UAS. CONCLUSIONS: Therefore, implant centers should should optimize respiratory sensing placement and adjustment.

15.
Phys Rev E ; 101(1-1): 012120, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32069672

RESUMO

The Fokker-Planck equation provides a complete statistical description of a particle undergoing random motion in a solvent. In the presence of Lorentz force due to an external magnetic field, the Fokker-Planck equation picks up a tensorial coefficient, which reflects the anisotropy of the particle's motion. This tensor, however, cannot be interpreted as a diffusion tensor; there are antisymmetric terms which give rise to fluxes perpendicular to the density gradients. Here, we show that for an inhomogeneous magnetic field these nondiffusive fluxes have finite divergence and therefore affect the density evolution of the system. Only in the special cases of a uniform magnetic field or carefully chosen initial condition with the same full rotational symmetry as the magnetic field can these fluxes be ignored in the density evolution.

16.
Epidemiol Psychiatr Sci ; 29: e84, 2020 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-31915099

RESUMO

AIMS: Although immune-mediated inflammatory diseases (IMID) are associated with multiple mental health conditions, there is a paucity of literature assessing personality disorders (PDs) in these populations. We aimed to estimate and compare the incidence of any PD in IMID and matched cohorts over time, and identify sociodemographic characteristics associated with the incidence of PD. METHODS: We used population-based administrative data from Manitoba, Canada to identify persons with incident inflammatory bowel disease (IBD), multiple sclerosis (MS) and rheumatoid arthritis (RA) using validated case definitions. Unaffected controls were matched 5:1 on sex, age and region of residence. PDs were identified using hospitalisation or physician claims. We used unadjusted and covariate-adjusted negative binomial regression to compare the incidence of PDs between the IMID and matched cohorts. RESULTS: We identified 19 572 incident cases of IMID (IBD n = 6,119, MS n = 3,514, RA n = 10 206) and 97 727 matches overall. After covariate adjustment, the IMID cohort had an increased incidence of PDs (incidence rate ratio [IRR] 1.72; 95%CI: 1.47-2.01) as compared to the matched cohort, which remained consistent over time. The incidence of PDs was similarly elevated in IBD (IRR 2.19; 95%CI: 1.69-2.84), MS (IRR 1.79; 95%CI: 1.29-2.50) and RA (IRR 1.61; 95%CI: 1.29-1.99). Lower socioeconomic status and urban residence were associated with an increased incidence of PDs, whereas mid to older adulthood (age 45-64) was associated with overall decreased incidence. In a restricted sample with 5 years of data before and after IMID diagnosis, the incidence of PDs was also elevated before IMID diagnosis among all IMID groups relative to matched controls. CONCLUSIONS: IMID are associated with an increased incidence of PDs both before and after an IMID diagnosis. These results support the relevance of shared risk factors in the co-occurrence of PDs and IMID conditions.


Assuntos
Artrite Reumatoide/epidemiologia , Doenças do Sistema Imunitário/complicações , Inflamação/complicações , Doenças Inflamatórias Intestinais/epidemiologia , Esclerose Múltipla/epidemiologia , Transtornos da Personalidade/epidemiologia , Adolescente , Adulto , Canadá/epidemiologia , Estudos de Coortes , Comorbidade/tendências , Feminino , Humanos , Doenças do Sistema Imunitário/epidemiologia , Incidência , Inflamação/epidemiologia , Masculino , Manitoba/epidemiologia , Pessoa de Meia-Idade , Transtornos da Personalidade/psicologia , Fatores de Risco , Fatores Socioeconômicos , Adulto Jovem
17.
Respir Physiol Neurobiol ; 274: 103351, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31751667

RESUMO

This study tested whether electrical stimulation of the pharyngeal mucosa is able to induce reliably the swallowing reflex in awake and asleep obstructive sleep apnea (OSA) patients, and whether the induced reflexes affect the sleep variables. In addition, the latency, occurrence, and morphology of swallows were evaluated. Eight patients received an esophageal catheter that was used on three consecutive nights for electrical stimulation and manometric recordings. The electrical stimulation proved itself safe, but its efficiency in inducing swallows sank from 80.0 % in awake to 37.4 % in sleeping subjects and was lowest in the sleep stage N3. The swallowing reflex was triggered with a mean latency of 3.69 ± 0.70 s, was predominantly induced in the hyperventilation phase, and had no significant effect on the subject's sleep variables. These findings indicate that electrical stimulation can more effectively trigger the swallowing reflex while the subjects are awake than during sleep without showing remarkable clinical benefits in terms of apnea-hypopnea index (AHI) improvement.


Assuntos
Deglutição/fisiologia , Reflexo/fisiologia , Apneia Obstrutiva do Sono/fisiopatologia , Fases do Sono/fisiologia , Vigília/fisiologia , Adulto , Idoso , Estimulação Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Faringe/fisiologia , Estudo de Prova de Conceito , Mucosa Respiratória/fisiologia
18.
Otolaryngol Head Neck Surg ; 161(5): 897-903, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31234734

RESUMO

OBJECTIVE: To examine whether previous palate or hypopharyngeal surgery was associated with efficacy of treatment of obstructive sleep apnea with hypoglossal nerve stimulation. STUDY DESIGN: Cohort (retrospective and prospective). SETTING: Eleven academic medical centers. SUBJECTS AND METHODS: Adults treated with hypoglossal nerve stimulation were enrolled in the ADHERE Registry. Outcomes were defined by the apnea-hypopnea index (AHI), in 3 ways: change in the AHI and 2 definitions of therapy response requiring ≥50% reduction in the AHI to a level <20 events/h (Response20) or 15 events/h (Response15). Previous palate and hypopharyngeal (tongue, epiglottis, or maxillofacial) procedures were documented. Linear and logistic regression examined the association between previous palate or hypopharyngeal surgery and outcomes, with adjustment for age, sex, and body mass index. RESULTS: The majority (73%, 217 of 299) had no previous palate or hypopharyngeal surgery, while 25% and 9% had previous palate or hypopharyngeal surgery, respectively, including 6% with previous palate and hypopharyngeal surgery. Baseline AHI (36.0 ± 15.6 events/h) decreased to 12.0 ± 13.3 at therapy titration (P < .001) and 11.4 ± 12.6 at final follow-up (P < .001). Any previous surgery, previous palate surgery, and previous hypopharyngeal surgery were not clearly associated with treatment response; for example, any previous surgery was associated with a 0.69 (95% CI: 0.37, 1.27) odds of response (Response20 measure) at therapy titration and a 0.55 (95% CI: 0.22, 1.34) odds of response (Response20 measure) at final follow-up. CONCLUSION: Previous upper airway surgery was not clearly associated with efficacy of hypoglossal nerve stimulation.


Assuntos
Terapia por Estimulação Elétrica , Nervo Hipoglosso , Hipofaringe/cirurgia , Palato/cirurgia , Apneia Obstrutiva do Sono/terapia , Adulto , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Retratamento , Resultado do Tratamento
19.
J Laryngol Otol ; 133(1): 59-72, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30706843

RESUMO

BACKGROUND: Important ear problems can affect the outer ear, the middle ear and the inner ear. Globally, the greatest burden of disease is due to ear conditions that are associated with otorrhoea and hearing loss. METHODS: This study reviewed the literature on the prevention and treatment of common ear conditions that are most relevant to settings with high rates of ear disease and limited resources. The grading of recommendations assessment, development and evaluation ('GRADE') approach was utilised to assess interventions. RESULTS: Accurate diagnosis of ear disease is challenging. Much of the preventable burden of ear disease is associated with otitis media. Nine otitis media interventions for which there is moderate to high certainty of effect were identified. While most interventions only provide modest benefit, the impact of treatment is more substantial in children with acute otitis media with perforation and chronic suppurative otitis media. CONCLUSION: Disease prevention through good hygiene practices, breastfeeding, reducing smoke exposure, immunisation and limiting noise exposure is recommended. Children with acute otitis media with perforation, chronic suppurative otitis media, complications of otitis media, and significant hearing loss should be prioritised for medical treatment.

20.
Eur Respir J ; 53(1)2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30487205

RESUMO

Upper airway stimulation (UAS) has been shown to reduce severity of obstructive sleep apnoea. The aim of this study was to identify predictors of UAS therapy response in an international multicentre registry.Patients who underwent UAS implantation in the United States and Germany were enrolled in an observational registry. Data collected included patient characteristics, apnoea/hypopnoea index (AHI), Epworth sleepiness scale (ESS), objective adherence, adverse events and patient satisfaction measures. Post hoc univariate and multiple logistic regression were performed to evaluate factors associated with treatment success.Between October 2016 and January 2018, 508 participants were enrolled from 14 centres. Median AHI was reduced from 34 to 7 events·h-1, median ESS reduced from 12 to 7 from baseline to final visit at 12-month post-implant. In post hoc analyses, for each 1-year increase in age, there was a 4% increase in odds of treatment success. For each 1-unit increase in body mass index (BMI), there was 9% reduced odds of treatment success. In the multivariable model, age persisted in serving as statistically significant predictor of treatment success.In a large multicentre international registry, UAS is an effective treatment option with high patient satisfaction and low adverse events. Increasing age and reduced BMI are predictors of treatment response.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Neuroestimuladores Implantáveis , Satisfação do Paciente , Vigilância de Produtos Comercializados , Apneia Obstrutiva do Sono/terapia , Idoso , Feminino , Alemanha , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS