Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 16(8): 10427-10438, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38375854

RESUMO

Capture and real-time recording of precise body movements using strain sensors provide personal information for healthcare monitoring and management. To acquire this information, a sensor that conforms to curved irregular surfaces, including biological tissue, is desired to record complex body movements while acting like a second skin to avoid interference with the movements. In this study, we developed a thin-film-type capacitive strain sensor that is flexible and stretchable on the surface of a living body. We fabricated conductive polymeric ultrathin films ("nanosheets") comprising polystyrene-block-polybutadiene (SB) elastomers and single-walled carbon nanotubes (SWCNTs) (i.e., SWCNT-SB nanosheets) via gravure coating; the SWCNT-SB-coated nanosheets were used as the flexible electrode in a capacitive strain sensor. The dielectric (DE) layer was then prepared using the silicone elastomer Ecoflex 00-30 because its Young's modulus is comparable to that of the epidermis. The normalized capacitance changes (ΔC/C0) in the sensor increased with increasing tensile strain over a range from 0-100%, indicating that the proposed sensor can measure the strain of biological movements, including those of skin and blood vessels. To improve sensor conformability further, the effect of sensor thickness on the gauge factor (GF) was investigated using thinner DE layers by focusing on their flexural rigidity. As a result, the GF increased from 0.64 to 1.13 as the DE layer thickness decreased from 260 to 40 µm. Finally, we evaluated the fabricated sensor's signal stability and mechanical durability, including during wireless sensing when applied to human skin and a vascular model. The ΔC/C0 values varied in response to the bending motion of a finger, dilation of a blood vessel, and the swallowing movement of the throat. These results indicate that our capacitive strain sensor is conformable and functional on biological tissue to enable monitoring of dynamic biological movements (e.g., pulse rate and arterial dilation) without wearer discomfort.


Assuntos
Nanotubos de Carbono , Dispositivos Eletrônicos Vestíveis , Humanos , Nanotubos de Carbono/química , Módulo de Elasticidade , Movimento , Movimento (Física)
2.
Biochem Biophys Res Commun ; 668: 1-7, 2023 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-37230045

RESUMO

The ability to monitor levels of endogenous markers and clearance profiles of drugs and their metabolites can improve the quality of biomedical research and precision with which therapies are individualized. Towards this end, electrochemical aptamer-based (EAB) sensors have been developed that support the real-time monitoring of specific analytes in vivo with clinically relevant specificity and sensitivity. A challenge associated with the in vivo deployment of EAB sensors, however, is how to manage the signal drift which, although correctable, ultimately leads to unacceptably low signal-to-noise ratios, limiting the measurement duration. Motivated by the correction of signal drift, in this paper, we have explored the use of oligoethylene glycol (OEG), a widely employed antifouling coating, to reduce the signal drift in EAB sensors. Counter to expectations, however, when challenged in 37 °C whole blood in vitro, EAB sensors employing OEG-modified self-assembled monolayers exhibit both greater drift and reduced signal gain, compared with those employ a simple, hydroxyl-terminated monolayer. On the other hand, when EAB sensor was prepared with a mix monolayer using MCH and lipoamido OEG 2 alcohol, reduced signal noise was observed compared to the same sensor prepared with MCH presumably due to improved SAM construction. These results suggest broader exploration of antifouling materials will be required to improve the signal drift of EAB sensors.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Técnicas Biossensoriais/métodos , Oligonucleotídeos , Glicóis , Técnicas Eletroquímicas
3.
Biomacromolecules ; 23(7): 2785-2792, 2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35700101

RESUMO

One strategy to prepare phase-separated co-assembly is to use the existing assembly as a platform to architect structures. For this purpose, the edge of a sheet or tube-shaped molecular assembly, which is less hydrophilic than the bulk region can become a starting point to build assembly units to realize more complex structures. In this study, we succeeded in preparing rod-shaped nanocapsules with previously unachieved sealing efficiency (>99%) by fine-tuning the properties of cationic amphiphilic polypeptides to seal the ends of neutral charge nanotubes. In addition, we demonstrated the nanocapsule's reversible responsiveness to salt. In high salt concentrations, a decrease in electrostatic repulsion between cationic polypeptides caused tearing and shrinking of the nanocapsule's sealing dome, which resulted in an opened nanotube. On the other hand, when salt was removed, the electrostatic repulsion among the cationic peptides localizing on the edge of opened nanocapsules was recovered, and the sealing membrane swelled up like an accordion to create a distance between the peptides, resulting in the restoration of the seal.


Assuntos
Nanocápsulas , Nanotubos de Peptídeos , Nanotubos , Cátions , Interações Hidrofóbicas e Hidrofílicas , Nanotubos/química , Peptídeos/química , Cloreto de Sódio
4.
Anal Sci ; 37(5): 707-712, 2021 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-33487600

RESUMO

In vitro selection has been widely used to generate molecular-recognition elements in analytical sciences. Although reconstituted types of in vitro transcription and translation (IVTT) system, such as PURE system, are nowadays widely used for ribosome display and mRNA/cDNA display, use of E. coli extract is often avoided, presumably because it contains unfavorable contaminants, such as ribonuclease. Nevertheless, the initial speed of protein translation in E. coli extract is markedly faster than that of PURE system. We thus hypothesized that E. coli extract is more appropriate for instant translation in ribosome display than PURE system. Here, we first revisit the potency of E. coli extract for ribosome display by shortening the translation time, and then applied the optimized condition for selecting peptide aptamers for ovalbumin (OVA). The OVA-binding peptides selected using E. coli extract exhibited specific binding to OVA, even in the presence of 50% serum. We conclude that instant translation in ribosome display using E. coli extract has the potential to generate easy-to-use and economical molecular-recognition elements in analytical sciences.


Assuntos
Escherichia coli , Ribossomos , Escherichia coli/genética , Ovalbumina , Peptídeos , Extratos Vegetais , Ribossomos/genética
5.
J Control Release ; 322: 209-216, 2020 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-32194174

RESUMO

Using polyethylene glycol (PEG) to functionalize liposomes improves their stealth properties and stability in blood. However, PEG is known to induce the accelerated blood clearance (ABC) phenomenon, which occurs for multiple doses owing to anti-PEG IgM being produced after the initial injection. In this study, as an alternative to PEG, polysarcosine (PSar) was selected owing to its low antigenicity and its highly dense chains with controllable lengths, similar to PEG. Furthermore, we directly evaluate the potential of PSar for avoiding the ABC phenomenon by comparing PSar with PEG on the same liposome platform, which has similar physicochemical properties such as hydrophobic region, membrane fluidity, and size. PEG- and PSar-liposomes were prepared and characterized for comparison. PSar-liposomes showed similar physicochemical properties to PEG-liposomes in terms of size control, zeta potential, membrane polarity, and fluidity; however, ELISA results showed noticeably lower levels and faster production speeds of both IgM and IgG for PSar-liposomes than for PEG-liposomes. In addition, a pharmacokinetics experiment with multiple injections showed that PSar-PE coating of liposomes may help to circumvent the ABC phenomenon.


Assuntos
Lipossomos , Polietilenoglicóis , Imunoglobulina M , Peptídeos , Sarcosina/análogos & derivados
6.
Biomacromolecules ; 20(10): 3908-3914, 2019 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-31532187

RESUMO

Artificial tubular networks are promising structures for biomaterial applications because of their large surface areas. A tubular network was formed by co-assembling two different amphiphilic polypeptides, poly(ethylene glycol)-b-(l-Leu-Aib)6 (PL12) and polysarcosine-b-(l-Leu-Aib)6 (SL12). They both have the same hydrophobic 12-mer helical block (l-Leu-Aib)6 but different hydrophilic chains, poly(ethylene glycol) and polysarcosine. In water, both polypeptides self-assembled into a tubular structure having a uniform 80 nm diameter that was formed by packing among the hydrophobic L12 blocks. The SL12 nanotubes were short (200 nm), straight, and robust. PL12 formed long (>1 µm), bendable, and fusogenic nanotubes. The amphiphiles were then co-assembled with various mixing ratios to form tubular networks. Higher concentrations of PL12 made the nanotubes more bendable and fusogenic between open tube ends, which produced branching junctions under heat treatment.


Assuntos
Nanotubos/química , Peptídeos/química , Temperatura Alta , Interações Hidrofóbicas e Hidrofílicas , Polietilenoglicóis/química , Sarcosina/análogos & derivados , Sarcosina/química
7.
Cancer Sci ; 110(3): 875-887, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30629329

RESUMO

Recent immunotherapies have shown clinical success. In particular, vaccines based on particulate antigen (Ag) are expected to be implemented based on their efficacy. In the current study, we describe a strategy entailing Ag-encapsulating PEG-modified liposomes (PGL-Ag) as antigen protein delivery devices and show that the success of the liposome depends on the antigen-presenting cell (APC) capacity; after administration of PGL-Ag, dendritic cells (DCs) in particular take up the Ag and subsequently prime T cells. For the generation of antitumor T cell responses in the lymphoid tissues, the function of encapsulated Ag-capturing DCs in vivo could be a biomarker. We next designed a prime-boost strategy to enhance the antitumor effects of the PGL-Ag. In the tumor sites, we show that Ag retention in nanoparticle-capturing DCs promotes a robust antitumor response. Thus, this efficient particulate Ag-based host antigen-presenting cell delivery strategy provides a bridge between innate and adaptive immune response and offers a novel therapeutic option against tumor cells.


Assuntos
Células Apresentadoras de Antígenos/imunologia , Antígenos/imunologia , Lipossomos/química , Animais , Biomarcadores Tumorais/imunologia , Vacinas Anticâncer/imunologia , Linhagem Celular Tumoral , Células Dendríticas/imunologia , Sistemas de Liberação de Medicamentos/métodos , Linfócitos/imunologia , Camundongos , Camundongos Endogâmicos C57BL , Nanopartículas/química , Linfócitos T/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA