Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
World J Urol ; 42(1): 248, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38647689

RESUMO

PURPOSE: Although targeted biopsies (TBx) are associated with improved disease assessment, concerns have been raised regarding the risk of prostate cancer (PCa) overgrading due to more accurate biopsy core deployment in the index lesion. METHODS: We identified 1672 patients treated with radical prostatectomy (RP) with a positive mpMRI and ISUP ≥ 2 PCa detected via systematic biopsy (SBx) plus TBx. We compared downgrading rates at RP (ISUP 4-5, 3, and 2 at biopsy, to a lower ISUP) for PCa detected via SBx only (group 1), via TBx only (group 2), and eventually for PCa detected with the same ISUP 2-5 at both SBx and TBx (group 3), using multivariable logistic regression models (MVA). RESULTS: Overall, 12 vs 14 vs 6% (n = 176 vs 227 vs 96) downgrading rates were recorded in group 1 vs group 2 vs group 3, respectively (p < 0.001). At MVA, group 2 was more likely to be downgraded (OR 1.26, p = 0.04), as compared to group 1. Conversely, group 3 was less likely to be downgraded at RP (OR 0.42, p < 0.001). CONCLUSIONS: Downgrading rates are highest when PCa is present in TBx only and, especially when the highest grade PCa is diagnosed by TBx cores only. Conversely, downgrading rates are lowest when PCa is identified with the same ISUP through both SBx and TBx. The presence of clinically significant disease at SBx + TBx may indicate a more reliable assessment of the disease at the time of biopsy potentially reducing the risk of downgrading at final pathology.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Humanos , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Masculino , Pessoa de Meia-Idade , Idoso , Biópsia Guiada por Imagem/métodos , Gradação de Tumores , Prostatectomia/métodos , Estudos Retrospectivos , Medição de Risco , Próstata/patologia , Biópsia/métodos
2.
Prostate Cancer Prostatic Dis ; 27(1): 122-128, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37770613

RESUMO

BACKGROUND: Robot-Assisted Simple Prostatectomy (RASP) has emerged as a promising alternative in the treatment of benign prostatic obstruction (BPO). However, there is currently a lack of comparative studies evaluating different robotic platforms for performing RASP. Therefore, we aimed to compare perioperative and functional outcomes of RASP performed using the HUGO™ RAS System versus the DaVinci® Xi System. METHODS: Forty consecutive cases of RASP performed between May 2021 and March 2023 with the HUGO™ RAS and the DaVinci® Xi at OLV Hospital (Aalst, Belgium) were included in this retrospective study. All surgeries were performed by three experienced surgeons using the same approach. Baseline characteristics, peri-operative and functional outcomes were collected and compared between the two groups. RESULTS: The population was equally divided between the two groups with 20 patients in each group. There were no significant differences in preoperative patient characteristics between the two groups, except for the presence of bladder stones prior to the surgery (p = 0.03). No significant differences in total operative time and console time between the two groups were reported (p = 0.3). No cases required conversion to open surgery or additional port placement. During one case performed with the HUGO™ RAS, a malfunctioning monopolar curved shear had to be replaced. However, there was no statistically significant differences in terms of technical robotic problems between the groups (p = 0.3). There was no significant difference between the two groups in perioperative and functional outcomes (all p ≥ 0.2). CONCLUSIONS: We did not observe any statistically significant difference in perioperative and functional outcomes in case of RASP performed with the HUGO™ RAS System and with the DaVinci® Xi System. These findings provide compelling support for considering the HUGO™ RAS as a promising tool for robot-assisted procedures, thereby expanding the utilization of robotics for benign conditions.


Assuntos
Hiperplasia Prostática , Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Robótica/métodos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Hiperplasia Prostática/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA