Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Ecotoxicol Environ Saf ; 170: 559-567, 2019 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-30576891

RESUMO

The residues of pharmaceutical and personal care products are the cause of increasing concern around the world. The aim of this study was to carry out the quantification of six antipsychotic drugs in hospital wastewater with the aid of liquid chromatography-mass spectrometry and, subsequently, make a preliminary assessment of the environmental risk posed. Dispersive liquid-liquid microextraction and solid phase extraction were optimized by multivariate design and validated in compliance with international guidelines. The extraction procedures were successfully applied to the quantification of the six selected antipsychotics in samples that were formed each day and collected at two main sampling points of the sewage network over the period of a week, in December 2017. Olanzapine (0.31─0.52 µg L-1), clozapine (0.56─0.97 µg L-1), haloperidol (1.43─2.73 µg L-1), risperidone (0.92─0.98 µg L-1) and chlorpromazine (0.52 µg L-1) were found in at least one sampling point. In the case of most analytes, the highest concentrations were determined at sampling point A, which are derived from the psychiatric wing. The environmental risk quotient for clozapine, chlorpromazine and risperidone was ˃600, a very high-risk index, which signals the need for a better control of the emission of antipsychotics and an improvement of the wastewater treatment, especially, with regard to wastewater discharged from the hospital psychiatric wing.


Assuntos
Antipsicóticos/análise , Hospitais Universitários , Águas Residuárias/química , Poluentes Químicos da Água/análise , Brasil , Cromatografia Líquida/métodos , Microextração em Fase Líquida/métodos , Medição de Risco , Esgotos/química , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos
2.
Chemosphere ; 201: 178-188, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29524818

RESUMO

Currently, there is an increasing use of anti-cancer drugs, and hence their occurrence in the environment must be properly managed, in particular, in the light of their high degree of toxicity. In this study, analytical methods using HPLC-FLD assisted by microextraction and solid phase extraction, were developed and validated for the determination of doxorubicin, daunorubicin, epirubicin and irinotecan in hospital effluent. The validation results show determination coefficients (r2) higher than 0.99 and recovery values between 74% and 105%, with an intraday precision of <15%.The limit of quantification was 1.0 µg L- 1 and there were almost no matrix effects. The methods proposed were employed for the determination of the named chemotherapeutics in effluent samples of the University Hospital of Santa Maria, Brazil and quantified in the range of ≥LOQ ̶ 6.22 µg L-1. A preliminary ecotoxicological risk assessment showed values that were potentially very harmful, and thus, the treatment of the hospital effluents requires special attention.


Assuntos
Antineoplásicos/análise , Cromatografia Líquida de Alta Pressão/métodos , Microextração em Fase Líquida/métodos , Extração em Fase Sólida/métodos , Águas Residuárias/química , Poluentes Químicos da Água/análise , Brasil , Hospitais Universitários , Humanos , Limite de Detecção , Medição de Risco
3.
Artigo em Inglês | MEDLINE | ID: mdl-28575579

RESUMO

Statins are classified as being amongst the most prescribed agents for treating hypercholesterolaemia and preventing vascular diseases. In this study, a rapid and effective liquid chromatography method, assisted by diode array detection, was designed and validated for the simultaneous quantification of atorvastatin (ATO) and simvastatin (SIM) in hospital effluent samples. The solid phase extraction (SPE) of the analytes was optimized regarding sorbent material and pH, and the dispersive liquid-liquid microextraction (DLLME), in terms of pH, ionic strength, type and volume of extractor/dispersor solvents. The performance of both extraction procedures was evaluated in terms of linearity, quantification limits, accuracy (recovery %), precision and matrix effects for each analyte. The methods proved to be linear in the concentration range considered; the quantification limits were 0.45 µg L-1 for ATO and 0.75 µg L-1 for SIM; the matrix effect was almost absent in both methods and the average recoveries remained between 81.5-90.0%; and the RSD values were <20%. The validated methods were applied to the quantification of the statins in real samples of hospital effluent; the concentrations ranged from 18.8 µg L-1 to 35.3 µg L-1 for ATO, and from 30.3 µg L-1 to 38.5 µg L-1 for SIM. Since the calculated risk quotient was ≤192, the occurrence of ATO and SIM in hospital effluent poses a potential serious risk to human health and the aquatic ecosystem.


Assuntos
Inibidores de Hidroximetilglutaril-CoA Redutases/análise , Poluentes Químicos da Água/análise , Brasil , Cromatografia Líquida de Alta Pressão/métodos , Hospitais Universitários , Microextração em Fase Líquida/métodos , Extração em Fase Sólida/métodos
4.
Chemosphere ; 170: 176-182, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27988453

RESUMO

A fast method for the determination of cocaine and its metabolites in hospital effluent samples was worked out by using liquid chromatography with the aid of fluorescence and diode array detection. Solid phase extraction and dispersive liquid -liquid microextraction were employed during the sample preparation stage. The experiment was conducted by using Chromabond® C18 ec 6 ml/500 mg cartridges, with recoveries higher than 96.6%, 88.3%, 78.7%, and LOQm 0.15; 0.18 and 0.30 µg L-1 for cocaine, benzoylecgonine and anhydroecgonine respectively. In the case of DLLME, different chemical conditions and solvent combinations were tested to find the best settings for the microextraction: pH 9; addition of 0.3 mol L-1 NaCl; 150 µL extractor (chloroform) and 350 µL disperser (methanol). The recoveries for cocaine were as high as 98.3% with LOQm 0.3 µg L-1. After validation, these methods were applied to quantification of the analytes. While the concentration of the anhydroecgonine, (the main pyrolytic metabolite of cocaine), remained below the limit of detection, the range of concentrations of cocaine and benzoylecgonine determined were 0.4-4.9 µg L-1 and 0.9-8.6 µg L-1, respectively. The occurrence has a relatively median/high environmental impact. These concentration values suggest that a role is played by other sources of cocaine, probably related to transport, or handling and the consumption of the drug. The outcome is that cocaine can be quantified by using DLLME as well as SPE, however, DLLME offered clear benefits like simplicity, affordability, and speed, as well as only requiring a small volume of solvents and samples.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cocaína/análise , Hospitais Universitários , Drogas Ilícitas/análise , Microextração em Fase Líquida/métodos , Poluentes Químicos da Água/análise , Brasil , Calibragem , Cocaína/análogos & derivados , Cocaína/metabolismo , Drogas Ilícitas/metabolismo , Limite de Detecção , Metanol/química , Reprodutibilidade dos Testes , Risco , Extração em Fase Sólida/métodos , Solventes/química , Águas Residuárias/química , Poluentes Químicos da Água/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA