Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 705
Filtrar
1.
World J Gastrointest Surg ; 16(3): 823-832, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38577081

RESUMO

BACKGROUND: Abdominal wall deficiencies or weakness are a common complication of temporary ostomies, and incisional hernias frequently develop after colostomy or ileostomy takedown. The use of synthetic meshes to reinforce the abdominal wall has reduced hernia occurrence. Biologic meshes have also been used to enhance healing, particularly in contaminated conditions. Reinforced tissue matrices (RTMs), which include a biologic scaffold of native extracellular matrix and a synthetic component for added strength/durability, are designed to take advantage of aspects of both synthetic and biologic materials. To date, RTMs have not been reported to reinforce the abdominal wall following stoma reversal. AIM: To evaluate the effectiveness of using an RTM to reinforce the abdominal wall at stoma takedown sites. METHODS: Twenty-eight patients were selected with a parastomal and/or incisional hernia who had received a temporary ileostomy or colostomy for fecal diversion after rectal cancer treatment or trauma. Following hernia repair and proximal stoma closure, RTM (OviTex® 1S permanent or OviTex® LPR) was placed to reinforce the abdominal wall using a laparoscopic, robotic, or open surgical approach. Post-operative follow-up was performed at 1 month and 1 year. Hernia recurrence was determined by physical examination and, when necessary, via computed tomography scan. Secondary endpoints included length of hospital stay, time to return to work, and hospital readmissions. Evaluated complications of the wound/repair site included presence of surgical site infection, seroma, hematoma, wound dehiscence, or fistula formation. RESULTS: The observational study cohort included 16 male and 12 female patients with average age of 58.5 years ± 16.3 years and average body mass index of 26.2 kg/m2 ± 4.1 kg/m2. Patients presented with a parastomal hernia (75.0%), incisional hernia (14.3%), or combined parastomal/incisional hernia (10.7%). Using a laparoscopic (53.6%), robotic (35.7%), or open (10.7%) technique, RTMs (OviTex® LPR: 82.1%, OviTex® 1S: 17.9%) were placed using sublay (82.1%) or intraperitoneal onlay (IPOM; 17.9%) mesh positioning. At 1-month and 1-year follow-ups, there were no hernia recurrences (0%). Average hospital stays were 2.1 d ± 1.2 d and return to work occurred at 8.3 post-operative days ± 3.0 post-operative days. Three patients (10.7%) were readmitted before the 1-month follow up due to mesh infection and/or gastrointestinal issues. Fistula and mesh infection were observed in two patients each (7.1%), leading to partial mesh removal in one patient (3.6%). There were no complications between 1 month and 1 year (0%). CONCLUSION: RTMs were used successfully to treat parastomal and incisional hernias at ileostomy reversal, with no hernia recurrences and favorable outcomes after 1-month and 1-year.

2.
Org Lett ; 26(9): 1975-1979, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38412434

RESUMO

We report the use of simple 1,4-dihydropyridine anions as a general platform for promoting single-electron photoreductions. In the presence of a mild base, 1,4-dihydropyridines were shown to effectively promote the hydrodechlorination and borylation of aryl chlorides and the photodetosylation of N-tosyl aromatic amines under visible light irradiation. Our studies also demonstrate that the C4 substituent can influence the reactivity of these anions, reducing unwanted side reactions like hydrogen atom transfer and back-electron transfer.

3.
J Biomech Eng ; 146(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38323715

RESUMO

To help foster interest in science, technology, engineering, and math (STEM), it is important to develop opportunities that excite and teach young minds about STEM-related fields. Over the past several years, our university-based research group has sought to help grow excitement around the biomechanics and biomedical engineering fields. The purposes of this technical brief are to (1) discuss the development of a partnership built between a St. Louis area high school and biomechanics research lab and (2) provide practical guidance for other researchers looking to implement a long-term outreach program. The partnership uses three different outreach opportunities. The first opportunity consisted of 12th-grade students visiting university research labs for an up-close perspective of ongoing biomedical research. The second opportunity was a biomedical research showcase where research-active graduate students traveled to the high school to perform demonstrations. The third opportunity consisted of a collaborative capstone project where a high school student was able to carry out research directly in a university lab. To date, we have expanded our reach from 19 students to interacting with over 100 students, which has yielded increased interest in STEM related research. Our postprogram survey showed that outreach programs such as the one described herein can increase interest in STEM within all ages of high school students. Building partnerships between high schools and university researchers increases the interest in STEM amongst high school students, and gives graduate students an outlet to present work to an eager-to-learn audience.


Assuntos
Instituições Acadêmicas , Estudantes , Humanos , Universidades , Engenharia , Engenharia Biomédica
4.
Dev Dyn ; 253(2): 233-254, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37688792

RESUMO

BACKGROUND: Latent TGFß binding protein-2 (LTBP2) is a fibrillin 1 binding component of the microfibril. LTBP2 is the only LTBP protein that does not bind any isoforms of TGFß, although it may interfere with the function of other LTBPs or interact with other signaling pathways. RESULTS: Here, we investigate mice lacking Ltbp2 (Ltbp2-/- ) and identify multiple phenotypes that impact bodyweight and fat mass, and affect bone and skin development. The alterations in skin and bone development are particularly noteworthy since the strength of these tissues is differentially affected by loss of Ltbp2. Interestingly, some tissues that express high levels of Ltbp2, such as the aorta and lung, do not have a developmental or homeostatic phenotype. CONCLUSIONS: Analysis of these mice show that LTBP2 has complex effects on development through direct effects on the extracellular matrix (ECM) or on signaling pathways that are known to regulate the ECM.


Assuntos
Proteínas de Transporte , Matriz Extracelular , Animais , Camundongos , Proteínas de Transporte/genética , Proteínas de Transporte/metabolismo , Matriz Extracelular/metabolismo , Fenótipo , Fator de Crescimento Transformador beta/metabolismo , Isoformas de Proteínas/metabolismo , Ligação Proteica
5.
Angew Chem Int Ed Engl ; 63(2): e202316064, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38015966

RESUMO

The cyclopropyl group is of great importance in medicinal chemistry, as it can be leveraged to influence a range of pharmaceutical properties in drug molecules. This report describes a Vitamin B12 -photocatalyzed approach for the cyclopropanation of electron-deficient alkenes using dichloromethane (CH2 Cl2 ) as the methylene source. The reaction proceeds in good to excellent yields under mild conditions, has excellent functional group compatibility, and is highly chemoselective. The scope could also be extended to the preparation of D2 -cyclopropyl and methyl-substituted cyclopropyl adducts starting from CD2 Cl2 and 1,1-dichloroethane, respectively.

6.
Kans J Med ; 16: 261-263, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37954880

RESUMO

Introduction: At home suture or staple removal can be stressful for patients and may lead some to seek out additional instruction via online resources as an adjunct to what was explained to them by their provider. The purpose of this study was to examine the existing online resources available to patients who may be interested in or have been instructed to remove sutures at home after a simple procedure, such as a skin biopsy or excision. Methods: A systematic search was conducted using internet search engines to identify videos and webpages targeting at home suture removal instruction. The DISCERN instrument was used to evaluate the information quality of each included resource. Results: There was no statistically significant difference between average DISCERN scores for videos and webpage resources, and the majority were rated poor in quality. Conclusions: The online resources for at home suture and staple removal were often not comprehensive and were below the standard quality for written information. Health care providers should consider referring their patients to validated online sources for suture removal to prevent misinformation and improve patient safety.

7.
J Homosex ; : 1-26, 2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37505504

RESUMO

This article presents a critical discourse analysis of groups on the free speech social media platform Gab that were intended to be LGBTQ+-friendly but became spaces of queerphobia. Results indicate that Gab users deployed discourses of difference to situate the platform as heteronormative and to denigrate the LGBTQ+ community. In particular, discourses utilized in the name of free speech were used to establish LGBTQ+ individuals as abominations, undergird hegemonic masculinity, and marginalize queer folk by reducing them to sex acts and sex organs. This study provides a better understanding of the (in)efficacy of "free speech" as a content moderation policy and unpacks how anti-LGBTQ+ hate speech spreads in digital spaces.

8.
J Biomed Opt ; 28(10): 102902, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37441242

RESUMO

Significance: Division-of-focal-plane Stokes polarimetry is emerging as a powerful tool for the microstructural characterization of soft tissues. How individual extracellular matrix (ECM) properties influence polarimetric signals in reflectance or transmission modes of quantitative polarized light imaging (QPLI) is not well understood. Aim: We aimed to investigate how ECM properties affect outcomes obtained from division-of-focal-plane polarimetric imaging in reflectance or transmission modes. Approach: Tunable collagen gel phantoms were used to modulate ECM properties of anisotropy, collagen density, crosslinking, and absorber density; the effects of degree of linear polarization (DoLP) and angle of polarization (AoP) on polarimetry outcomes were assessed. A model biological tissue (i.e., bovine tendon) was similarly imaged and evaluated using both reflectance and transmission modes. Results: Reflectance QPLI resulted in decreased DoLP compared with transmission mode. A 90 deg shift in AoP was observed between modes but yielded similar spatial patterns. Collagen density had the largest effect on outcomes besides anisotropy in both imaging modes. Conclusions: Both imaging modes were sufficiently sensitive to detect structural anisotropy differences in gels of varying fiber alignment. Conclusions drawn from phantom experiments should carry over when interpreting data from more complex tissues and can help provide context for interpretation of other Stokes polarimetry data.


Assuntos
Colágeno , Diagnóstico por Imagem , Animais , Bovinos , Análise Espectral , Anisotropia , Imagens de Fantasmas , Colágeno/química
9.
Med Devices (Auckl) ; 16: 123-132, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37304735

RESUMO

Introduction: Excessive bleeding in trauma and surgical settings leads to increased operative time, reoperation rates, and overall healthcare costs. A wide range of hemostatic agents have been developed to control bleeding that can vary considerably in type of hemostatic action, ease of application, cost, risk of infection, and dependence on patient coagulation. Microfibrillar collagen-based hemostatic materials (MCH) have yielded beneficial results in a variety of applications. Methods: A new flowable collagen product, containing a modified MCH flour, but in a more convenient flowable delivery system, was evaluated for hemostatic efficacy in preclinical models of solid organ injury and spinal cord exposure. The primary objective of this study was to compare the hemostatic potential and local tissue responses to this novel, flowable collagen-based hemostatic agent to the original flour formulation to confirm that the new method of delivery did not interfere with the hemostatic properties of the MCH flour. Results: When observed visually, the flowable MCH flour mixed with saline (FL) provided more precise application and uniform coverage to injured tissues compared to the dry MCH flour alone (F0). All of the treatments (FL, F0, and gauze) exhibited comparable Lewis bleed grade at all three time points evaluated in the capsular resection liver injury model (bleed grade: 1.0-1.3; p> 0.05 in all cases). FL and F0 exhibited comparable 100% acute hemostatic efficacy and similar long-term histomorphological properties (up to 120 days) in a capsular resection liver injury in pigs, while gauze resulted in significantly lower rates of acute hemostatic efficacy (8-42%, p<0.05 in all cases). In an ovine model of dorsal laminectomy and durotomy, FL and F0 again exhibited comparable results without any neurological effects. Conclusion: Flowable microfibrillar collagen was shown to yield favorable short- and long-term outcomes in two representative applications where hemostatic efficacy is critical to surgical success.

10.
J Orthop Res ; 41(10): 2105-2113, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37312619

RESUMO

Tendons are critical for the biomechanical function of joints. Tendons connect muscles to bones and allow for the transmission of muscle forces to facilitate joint motion. Therefore, characterizing the tensile mechanical properties of tendons is important for the assessment of functional tendon health and efficacy of treatments for acute and chronic injuries. In this guidelines paper, we review methodological considerations, testing protocols, and key outcome measures for mechanical testing of tendons. The goal of the paper is to present a simple set of guidelines to the nonexpert seeking to perform tendon mechanical tests. The suggested approaches provide rigorous and consistent methodologies for standardized biomechanical characterization of tendon and reporting requirements across laboratories.


Assuntos
Músculos , Tendões , Fenômenos Biomecânicos , Tendões/fisiologia , Resistência à Tração , Testes Mecânicos
11.
Plant Genome ; 16(3): e20349, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37195017

RESUMO

Quinoa (Chenopodium quinoa), an Andean pseudocereal, attained global popularity beginning in the early 2000s due to its protein quality, glycemic index, and high fiber, vitamin, and mineral contents. Pitseed goosefoot (Chenopodium berlandieri), quinoa's North American free-living sister species, grows on disturbed and sandy substrates across the North America, including saline coastal sands, southwestern deserts, subtropical highlands, the Great Plains, and boreal forests. Together with South American avian goosefoot (Chenopodium hircinum) they comprise the American tetraploid goosefoot complex (ATGC). Superimposed on pitseed goosefoot's North American range are approximately 35 AA diploids, most of which are adapted to a diversity of niche environments. We chose to assemble a reference genome for Sonoran A-genome Chenopodium watsonii due to fruit morphological and high (>99.3%) preliminary sequence-match similarities with quinoa, along with its well-established taxonomic status. The genome was assembled into 1377 scaffolds spanning 547.76 Mb (N50 = 55.14 Mb, L50 = 5), with 94% comprised in nine chromosome-scale scaffolds and 93.9% Benchmarking Universal Single-Copy Orthologs genes identified as single copy and 3.4% as duplicated. A high degree of synteny, with minor and mostly telomeric rearrangements, was found when comparing this taxon with the previously reported genome of South American C. pallidicaule and the A-subgenome chromosomes of C. quinoa. Phylogenetic analysis was performed using 10,588 single-nucleotide polymorphisms generated by resequencing a panel of 41 New World AA diploid accessions and the Eurasian H-genome diploid Chenopodium vulvaria, along with three AABB tetraploids previously sequenced. Phylogenetic analysis of these 32 taxa positioned the psammophyte Chenopodium subglabrum on the branch containing A-genome sequences from the ATGC. We also present evidence for long-range dispersal of Chenopodium diploids between North and South America.


Assuntos
Chenopodium quinoa , Chenopodium , Chenopodium quinoa/genética , Chenopodium/genética , Filogenia , Genoma de Planta , Tetraploidia , Cromossomos
13.
J Bone Joint Surg Am ; 105(3): 223-230, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36723466

RESUMO

BACKGROUND: Simple elbow dislocation occurs at an incidence of 2.9 to 5.21 dislocations per 100,000 person-years, with as many as 62% of these patients experiencing long-term elbow joint contracture, stiffness, and/or pain. Poor outcomes and the need for secondary surgical intervention can often be prevented nonoperatively with early or immediate active mobilization and physical therapy. However, immobilization or limited mobilization may be necessary following trauma, and it is unknown how different periods of immobilization affect pathological changes in elbow joint tissue and how these changes relate to range of motion (ROM). The purpose of this study was to investigate the effects of varying the initiation of free mobilization on elbow ROM and histological features in an animal model of elbow posttraumatic joint contracture. METHODS: Traumatic elbow dislocation was surgically induced unilaterally in rats. Injured forelimbs were immobilized in bandages for 3, 7, 14, or 21 days; free mobilization was then allowed until 42 days after injury. Post-mortem joint ROM testing and histological analysis were performed. One-way analysis of variance was used to compare ROM data between control and injured groups, and Pearson correlations were performed between ROM parameters and histological outcomes. RESULTS: Longer immobilization periods resulted in greater ROM reductions. The anterior and posterior capsule showed increases in cellularity, fibroblasts, adhesions, fibrosis, and thickness, whereas the measured outcomes in cartilage were mostly unaffected. All measured histological characteristics of the capsule were negatively correlated with ROM, indicating that higher degrees of pathology corresponded with less ROM. CONCLUSIONS: Longer immobilization periods resulted in greater ROM reductions, which correlated with worse histological outcomes in the capsule in an animal model of posttraumatic elbow contracture. The subtle differences in the timing of ROM and capsule tissue changes revealed in the present study provide new insight into the distinct timelines of biomechanical changes as well as regional tissue pathology. CLINICAL RELEVANCE: This study showed that beginning active mobilization 3 days after injury minimized posttraumatic joint contracture, thereby supporting an immediate-motion clinical treatment strategy (when possible). Furthermore, uninjured but pathologically altered periarticular tissues near the injury location may contribute to more severe contracture during longer immobilization periods as the disease state progresses.


Assuntos
Contratura , Articulação do Cotovelo , Luxações Articulares , Ratos , Animais , Cotovelo , Luxações Articulares/complicações , Contratura/etiologia , Modalidades de Fisioterapia , Amplitude de Movimento Articular
14.
FASEB J ; 37(2): e22714, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36583692

RESUMO

While it is well known that mechanical signals can either promote or disrupt intervertebral disc (IVD) homeostasis, the molecular mechanisms for transducing mechanical stimuli are not fully understood. The transient receptor potential vanilloid 4 (TRPV4) ion channel activated in isolated IVD cells initiates extracellular matrix (ECM) gene expression, while TRPV4 ablation reduces cytokine production in response to circumferential stretching. However, the role of TRPV4 on ECM maintenance during tissue-level mechanical loading remains unknown. Using an organ culture model, we modulated TRPV4 function over both short- (hours) and long-term (days) and evaluated the IVDs' response. Activating TRPV4 with the agonist GSK101 resulted in a Ca2+ flux propagating across the cells within the IVD. Nuclear factor (NF)-κB signaling in the IVD peaked at 6 h following TRPV4 activation that subsequently resulted in higher interleukin (IL)-6 production at 7 days. These cellular responses were concomitant with the accumulation of glycosaminoglycans and increased hydration in the nucleus pulposus that culminated in higher stiffness of the IVD. Sustained compressive loading of the IVD resulted in elevated NF-κB activity, IL-6 and vascular endothelial growth factor A (VEGFA) production, and degenerative changes to the ECM. TRPV4 inhibition using GSK205 during loading mitigated the changes in inflammatory cytokines, protected against IVD degeneration, but could not prevent ECM disorganization due to mechanical damage in the annulus fibrosus. These results indicate TRPV4 plays an important role in both short- and long-term adaptations of the IVD to mechanical loading. The modulation of TRPV4 may be a possible therapeutic for preventing load-induced IVD degeneration.


Assuntos
Antineoplásicos , Degeneração do Disco Intervertebral , Disco Intervertebral , Núcleo Pulposo , Humanos , Canais de Cátion TRPV/genética , Canais de Cátion TRPV/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo , Disco Intervertebral/metabolismo , Degeneração do Disco Intervertebral/metabolismo , Núcleo Pulposo/metabolismo , Antineoplásicos/metabolismo
15.
J Physiol ; 601(15): 3151-3171, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36223200

RESUMO

Electrophysiological recordings can provide detailed information of single neurons' dynamical features and shed light on their response to stimuli. Unfortunately, rapidly modelling electrophysiological data for inferring network-level behaviours remains challenging. Here, we investigate how modelled single neuron dynamics leads to network-level responses in the paraventricular nucleus of the hypothalamus (PVN), a critical nucleus for the mammalian stress response. Recordings of corticotropin releasing hormone neurons from the PVN (CRHPVN ) were performed using whole-cell current-clamp. These, neurons, which initiate the endocrine response to stress, were rapidly and automatically fit to a modified adaptive exponential integrate-and-fire model (AdEx) with particle swarm optimization (PSO). All CRHPVN neurons were accurately fit by the AdEx model with PSO. Multiple sets of parameters were found that reliably reproduced current-clamp traces for any single neuron. Despite multiple solutions, the dynamical features of the models such as the rheobase, fixed points, and bifurcations, were shown to be stable across fits. We found that CRHPVN neurons can be divided into two subtypes according to their bifurcation at the onset of firing: CRHPVN -integrators and CRHPVN -resonators. The existence of CRHPVN -resonators was then directly confirmed in a follow-up patch-clamp hyperpolarization protocol which readily induced post-inhibitory rebound spiking in 33% of patched neurons. We constructed networks of CRHPVN model neurons to investigate the network level responses of CRHPVN neurons. We found that CRHPVN -resonators maintain baseline firing in networks even when all inputs are inhibitory. The dynamics of a small subset of CRHPVN neurons may be critical to maintaining a baseline firing tone in the PVN. KEY POINTS: Corticotropin-releasing hormone neurons (CRHPVN ) in the paraventricular nucleus of the hypothalamus act as the final neural controllers of the stress response. We developed a computational modelling platform that uses particle swarm optimization to rapidly and accurately fit biophysical neuron models to patched CRHPVN neurons. A model was fitted to each patched neuron without the use of dynamic clamping, or other procedures requiring sophisticated inputs and fitting algorithms. Any neuron undergoing standard current clamp step protocols for a few minutes can be fitted by this procedure The dynamical analysis of the modelled neurons shows that CRHPVN neurons come in two specific 'flavours': CRHPVN -resonators and CRHPVN -integrators. We directly confirmed the existence of these two classes of CRHPVN neurons in subsequent experiments. Network simulations show that CRHPVN -resonators are critical to retaining the baseline firing rate of the entire network of CRHPVN neurons as these cells can fire rebound spikes and bursts in the presence of strong inhibitory synaptic input.


Assuntos
Hormônio Liberador da Corticotropina , Núcleo Hipotalâmico Paraventricular , Hormônio Liberador da Corticotropina/metabolismo , Hipotálamo/metabolismo , Neurônios/fisiologia
16.
J Orthop Res ; 41(10): 2329-2338, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36324161

RESUMO

Quantitative magnetic resonance imaging (qMRI) measures have provided insights into the composition, quality, and structure-function of musculoskeletal tissues. Low signal-to-noise ratio has limited application to tendon. Advances in scanning sequences and sample positioning have improved signal from tendon allowing for evaluation of structure and function. The purpose of this study was to elucidate relationships between tendon qMRI metrics (T1, T2, T1ρ and diffusion tensor imaging [DTI] metrics) with tendon tissue mechanics, collagen concentration and organization. Sixteen human Achilles tendon specimens were collected, imaged with qMRI, and subjected to mechanical testing with quantitative polarized light imaging. T2 values were related to tendon mechanics [peak stress (rsp = 0.51, p = 0.044), equilibrium stress (rsp = 0.54, p = 0.033), percent relaxation (rsp = -0.55, p = 0.027), hysteresis (rsp = -0.64, p = 0.007), linear modulus (rsp = 0.67, p = 0.009)]. T1ρ had a statistically significant relationship with percent relaxation (r = 0.50, p = 0.048). Collagen content was significantly related to DTI measures (range of r = 0.56-0.62). T2 values from a single slice of the midportion of human Achilles tendons were strongest predictors of tendon tensile mechanical metrics. DTI diffusivity indices (mean diffusivity, axial diffusivity, radial diffusivity) were strongly correlated with collagen content. These findings build on a growing body of literature supporting the feasibility of qMRI to characterize tendon tissue and noninvasively measure tendon structure and function. Statement of Clinical Significance: Quantitative MRI can be applied to characterize tendon tissue and is a noninvasive measure that relates to tendon composition and mechanical behavior.


Assuntos
Tendão do Calcâneo , Imagem de Tensor de Difusão , Humanos , Imagem de Tensor de Difusão/métodos , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética , Tendão do Calcâneo/diagnóstico por imagem , Colágeno
17.
Physiol Rev ; 103(2): 1667-1691, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36395349

RESUMO

The corticotropin-releasing hormone cells in the paraventricular nucleus of the hypothalamus (CRHPVN) control the slow endocrine response to stress. The synapses on these cells are exquisitely sensitive to acute stress, leveraging local signals to leave a lasting imprint on this system. Additionally, recent work indicates that these cells also play key roles in the control of distinct stress and survival behaviors. Here we review these observations and provide a perspective on the role of CRHPVN neurons as integrative and malleable hubs for behavioral, physiological, and endocrine responses to stress.


Assuntos
Hormônio Liberador da Corticotropina , Núcleo Hipotalâmico Paraventricular , Humanos , Hormônio Liberador da Corticotropina/metabolismo , Núcleo Hipotalâmico Paraventricular/metabolismo , Neurônios/fisiologia , Sinapses/metabolismo , Estresse Fisiológico
18.
Am J Sports Med ; 51(1): 205-213, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36412519

RESUMO

BACKGROUND: Medial ulnar collateral ligament (mUCL) reconstructions are becoming increasingly prevalent among the overhand throwing population. Suture tape augmentation has the potential to provide biomechanical advantages over standard docking reconstruction. However, the optimal tensioning of the suture augmentation technique has not yet been evaluated. PURPOSE: To compare the subfailure biomechanical performance and graft strain of a standard docking mUCL reconstruction to an mUCL reconstruction using suture tape augmentation tensioned with 1 mm or 3 mm of laxity. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 18 cadaveric elbows were dissected to the mUCL anterior band and biomechanically assessed via a valgus torque protocol to failure. Elbows were randomly assigned to be reconstructed via (1) a standard docking technique, (2) a suture-augmented reconstruction with 1-mm laxity, or (3) a suture-augmented reconstruction with 3-mm laxity. Reconstructed elbows were then subjected to the same loading protocol. Subfailure mechanical properties, failure mode, and mUCL/palmaris strain were assessed. RESULTS: All reconstruction groups had decreased rotational stiffness, torque at 5° of angular rotation, and resilience compared with matched native controls. There were no differences in transition torque between groups. The failure mode of suture-augmented specimens was most often due to bone tunnel failure or reaching the maximum allowable angular displacement. In native controls or docking reconstructions, the primary failure mechanism was in the ligament or graft midsubstance. There were no significant differences in strain on the reconstructed or suture-augmented groups at any laxity compared with native controls. CONCLUSION: Suture augmentation results in similar subfailure joint biomechanical properties as the standard docking reconstruction procedure at both laxity levels in a cadaveric model. There are improvements in the failure mode of suture-augmented specimens compared with standard docking. Graft strain may be modestly reduced in the 1-mm laxity group compared with other reconstruction groups. CLINICAL RELEVANCE: Suture augmentation at both 1-mm and 3-mm laxity appears to offer similar advantages in subfailure biomechanics to standard docking reconstruction of the mUCL, with some improvements associated with failure mode. Strain data suggest a potential avoidance of graft stress shielding when tensioning the suture augmentation to 3-mm laxity, which is not as apparent with 1-mm laxity.


Assuntos
Ligamento Colateral Ulnar , Ligamentos Colaterais , Articulação do Cotovelo , Reconstrução do Ligamento Colateral Ulnar , Humanos , Cotovelo/cirurgia , Reconstrução do Ligamento Colateral Ulnar/métodos , Cadáver , Amplitude de Movimento Articular , Articulação do Cotovelo/cirurgia , Ligamento Colateral Ulnar/cirurgia , Fenômenos Biomecânicos , Suturas , Ligamentos Colaterais/cirurgia
19.
J Aquat Anim Health ; 35(1): 11-19, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36052668

RESUMO

OBJECTIVE: A privately owned, 4-year-old female Showa koi (ornamental variant of Common Carp Cyprinus carpio) was presented for erratic swimming, air gasping, water spitting, and abnormal orientation in the water column. Initial physical examination revealed an obese patient with no external abnormalities except a small plaque localized to filaments on a right gill hemibranch. METHODS: The fish was anesthetized using AQUI-S 20E (10% eugenol solution) at 50 mg/L to facilitate diagnostic evaluation. Biopsy of the gill lesion yielded no significant findings. Whole-body computed tomography confirmed an excess of adipose tissue and mild scoliosis, with narrowing of the 10th-11th intervertebral space. A weight loss plan and need for repeat assessment were recommended. RESULT: The patient's original abnormal behaviors resolved over the following weeks, but it subsequently became hyporexic and depressed. Full-body magnetic resonance imaging (MRI) showed extensive alteration of vertebral centra, with multifocal compression of the spinal cord. Due to the patient's declining clinical condition and the grave prognosis based on MRI findings, the patient was humanely euthanized. CONCLUSION: Postmortem examination showed severe transmural myelomalacia associated with a vertebral subluxation. This case demonstrates the practical application of advanced cross-sectional imaging that has not been commonly afforded to fish or other lower vertebrates.


Assuntos
Carpas , Imageamento por Ressonância Magnética , Traumatismos da Coluna Vertebral , Tomografia Computadorizada por Raios X , Animais , Carpas/lesões , Tomografia Computadorizada por Raios X/veterinária , Traumatismos da Coluna Vertebral/diagnóstico por imagem , Traumatismos da Coluna Vertebral/veterinária , Feminino , Imageamento por Ressonância Magnética/veterinária , Comportamento Animal , Compressão da Medula Espinal/diagnóstico por imagem , Compressão da Medula Espinal/veterinária , Eutanásia Animal
20.
Acta Biomater ; 163: 91-105, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35306182

RESUMO

Elastin, the main component of elastic fibers, has been demonstrated to significantly influence tendon mechanics using both elastin degradation studies and elastinopathic mouse models. However, it remains unclear how prior results differ between species and functionally distinct tendons and, in particular, how results translate to human tendon. Differences in function between fascicular and interfascicular elastin are also yet to be fully elucidated. Therefore, this study evaluated the quantity, structure, and mechanical contribution of elastin in functionally distinct tendons across species. Tendons with an energy-storing function had slightly more elastin content than tendons with a positional function, and human tendon had at least twice the elastin content of other species. While distinctions in the organization of elastic fibers between fascicles and the interfascicular matrix were observed, differences in structural arrangement of the elastin network between species and tendon type were limited. Mechanical testing paired with enzyme-induced elastin degradation was used to evaluate the contribution of elastin to tendon mechanics. Across all tendons, elastin degradation affected the elastic stress response by decreasing stress values while increasing the modulus gradient of the stress-strain curve. Only the contributions of elastin to viscoelastic properties varied between tendon type and species, with human tendon and energy-storing tendon being more affected. These data suggest that fascicular elastic fibers contribute to the tensile mechanical response of tendon, likely by regulating collagen engagement under load. Results add to prior findings and provide evidence for a more mechanistic understanding of the role of elastic fibers in tendon. STATEMENT OF SIGNIFICANCE: Elastin has previously been shown to influence the mechanical properties of tendon, and degraded or abnormal elastin networks caused by aging or disease may contribute to pain and an increased risk of injury. However, prior work has not fully determined how elastin contributes differently to tendons with varying functional demands, as well as within distinct regions of tendon. This study determined the effects of elastin degradation on the tensile elastic and viscoelastic responses of tendons with varying functional demands, hierarchical structures, and elastin content. Moreover, volumetric imaging and protein quantification were used to thoroughly characterize the elastin network in each distinct tendon. The results presented herein can inform tendon-specific strategies to maintain or restore native properties in elastin-degraded tissue.


Assuntos
Colágeno , Elastina , Camundongos , Animais , Humanos , Elastina/metabolismo , Colágeno/metabolismo , Tendões/fisiologia , Envelhecimento/metabolismo , Tecido Elástico/metabolismo , Módulo de Elasticidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA