Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Inflamm Bowel Dis ; 2023 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-37738567

RESUMO

BACKGROUND: Chronic inflammation in immune-mediated conditions has been associated with an increased risk in atherosclerotic disease. There is paucity of evidence regarding the prevalence of asymptomatic atherosclerosis in patients with ulcerative colitis (UC) and its association with disease activity. We sought to compare the prevalence of asymptomatic atherosclerotic disease between young patients with UC with and without mucosal healing (MH) and healthy control individuals. METHODS: An observational study was conducted in 2 hospitals in Buenos Aires, Argentina. Patients with UC 18 to 50 years of age with at least 1 previous colonoscopy in the last year were enrolled, along with age- and sex-matched healthy control individuals. Carotid and femoral ultrasound assessments were performed to determine the prevalence of atherosclerotic lesions and abnormal intima-media thickness (IMT). We compared the prevalence of atherosclerotic disease and the prevalence of abnormally increased IMT in at least 1 vascular territory. RESULTS: Sixty patients with UC and 60 healthy control individuals were enrolled. Mean age was 38 years and 53.33% were men. Although the prevalence of atherosclerotic lesions was similar in patients with UC without MH when compared with both patients with UC with MH and control individuals (3.7% vs 0% vs 6.67%; P = .1), we found a significant increase in abnormal IMT in at least 1 vascular territory in UC patients without MH when compared with healthy control individuals (48.15% vs 26.67%; P = .05). CONCLUSIONS: Patients with UC with active mucosal inflammation showed a significantly increased odds of asymptomatic femoral or carotid vascular disease when compared with control individuals.


Young patients with endoscopically active ulcerative colitis showed a significantly higher prevalence of abnormal intima-media thickness when compared with control individuals. Among patients with ulcerative colitis, age, disease duration, and C-reactive protein were associated with increased odds of asymptomatic vascular lesions.

2.
Medicina (B.Aires) ; 82(1): 61-65, feb. 2022. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1365129

RESUMO

Abstract Coronavirus disease 2019 (COVID-19) produces a significant burden to severely ill patients affected by acute respiratory failure. The aim of this study was to describe echocardiographic findings in a series of mechanically ventilated patients with moderate and severe acute respiratory distress syndrome (ARDS) due to COVID-19. This was a single center, descriptive and cros s-sectional study of prospectively collected data. Patients had severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and moderate or severe ARDS. Initial echocardiogram was performed within 7 days of intensive care unit admission and every 15 days until mechanical ventilation ended, 28 days or death. Time spent by the physician for each study was measured. Multiple echographic measurements were acquired; 33 patients were analyzed. Total number of echocardiograms performed was 76. The median imaging time required to complete a standard study was 13 [10-15] minutes. Chronic structural abnormalities were present in 16 patients (48%), being LV hypertrophy the main finding in 11 patients (33%). The most frequent acute or dynamic finding was RV enlargement (43%) when considering all echocardiograms performed from admission to day 28 of follow-up. Other findings were: pulmonary hypertension (15%), new or dynamic left ventricle (LV) regional wall motion abnormalities (15%), new or dynamic LV global contractility deterioration (6%) and hypercontractility (12%).


Resumen La enfermedad por coronavirus 2019 (COVID-19) produce una carga significativa para los pacientes gravemente enfermos afectados por insuficiencia respiratoria aguda. El objetivo de este estudio fue describir los hallazgos ecocardiográficos en una serie de pacientes ventilados mecánicamente con síndrome de dificultad respiratoria aguda (SDRA) moderado y grave debido a COVID-19. Se trata de un estudio unicéntrico, descriptivo y de corte transversal de datos recopilados en forma prospectiva. Los pacientes tenían una infección por el coronavirus SARS-Cov-2 y SDRA moderado o grave. El ecocardiogra ma inicial se realizó dentro de los 7 días del ingreso en la unidad de cuidados intensivos y luego cada 15 días hasta finalizar la ventilación mecánica, 28 días o fallecimiento. Se midió el tiempo empleado por el operador en cada estudio. Se adquirieron múltiples medidas ecográficas. Se analizaron 33 pacientes. El número total de ecocardiogramas realizados fue de 76. El tiempo necesario (mediana [RIQ]) para la obtención de las imágenes de un estudio estándar fue de 13 [10-15] minutos. Las anomalías estructurales crónicas estuvieron presentes en 16 pacientes (48%), siendo la hipertrofia ventricular izquierda la principal (11 pacientes, 33%). El hallazgo agudo o dinámico más frecuente fue el agrandamiento del ventrículo derecho (VD) (43%) al considerar todos los ecocardiogramas realizados desde el ingreso hasta el día 28 de seguimiento. Otros hallazgos fueron: hipertensión pulmonar (15%), anomalías del movimiento de la pared regional del VI nuevas o dinámicas (15%), deterioro de la contractilidad global del ventrículo izquierdo, nuevo o dinámico (6%), e hipercontractilidad (12%).

3.
Medicina (B Aires) ; 82(1): 61-65, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35037862

RESUMO

Coronavirus disease 2019 (COVID-19) produces a significant burden to severely ill patients affected by acute respiratory failure. The aim of this study was to describe echocardiographic findings in a series of mechanically ventilated patients with moderate and severe acute respiratory distress syndrome (ARDS) due to COVID-19. This was a single center, descriptive and cros s-sectional study of prospectively collected data. Patients had severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and moderate or severe ARDS. Initial echocardiogram was performed within 7 days of intensive care unit admission and every 15 days until mechanical ventilation ended, 28 days or death. Time spent by the physician for each study was measured. Multiple echographic measurements were acquired; 33 patients were analyzed. Total number of echocardiograms performed was 76. The median imaging time required to complete a standard study was 13 [10-15] minutes. Chronic structural abnormalities were present in 16 patients (48%), being LV hypertrophy the main finding in 11 patients (33%). The most frequent acute or dynamic finding was RV enlargement (43%) when considering all echocardiograms performed from admission to day 28 of follow-up. Other findings were: pulmonary hypertension (15%), new or dynamic left ventricle (LV) regional wall motion abnormalities (15%), new or dynamic LV global contractility deterioration (6%) and hypercontractility (12%).


La enfermedad por coronavirus 2019 (COVID-19) produce una carga significativa para los pacientes gravemente enfermos afectados por insuficiencia respiratoria aguda. El objetivo de este estudio fue describir los hallazgos ecocardiográficos en una serie de pacientes ventilados mecánicamente con síndrome de dificultad respiratoria aguda (SDRA) moderado y grave debido a COVID-19. Se trata de un estudio unicéntrico, descriptivo y de corte transversal de datos recopilados en forma prospectiva. Los pacientes tenían una infección por el coronavirus SARS-Cov-2 y SDRA moderado o grave. El ecocardiograma inicial se realizó dentro de los 7 días del ingreso en la unidad de cuidados intensivos y luego cada 15 días hasta finalizar la ventilación mecánica, 28 días o fallecimiento. Se midió el tiempo empleado por el operador en cada estudio. Se adquirieron múltiples medidas ecográficas. Se analizaron 33 pacientes. El número total de ecocardiogramas realizados fue de 76. El tiempo necesario (mediana [RIQ]) para la obtención de las imágenes de un estudio estándar fue de 13 [10-15] minutos. Las anomalías estructurales crónicas estuvieron presentes en 16 pacientes (48%), siendo la hipertrofia ventricular izquierda la principal (11 pacientes, 33%). El hallazgo agudo o dinámico más frecuente fue el agrandamiento del ventríc ulo derecho (VD) (43%) al considerar todos los ecocardiogramas realizados desde el ingreso hasta el día 28 de seguimiento. Otros hallazgos fueron: hipertensión pulmonar (15%), anomalías del movimiento de la pared regional del VI nuevas o dinámicas (15%), deterioro de la contractilidad global del ventrículo izquierdo, nuevo o dinámico (6%), e hipercontractilidad (12%).


Assuntos
COVID-19 , Síndrome do Desconforto Respiratório , Ecocardiografia , Humanos , Respiração Artificial , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/terapia , SARS-CoV-2
4.
Eur Heart J Case Rep ; 3(2)2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-31449614

RESUMO

BACKGROUND: The Ehlers-Danlos Syndrome (EDS) is part of a group of connective tissue diseases that affect the synthesis and processing of collagen leading to alterations in the structure of many tissues and organs. CASE SUMMARY: Herein, we reported a case of a patient with prolapse of the four cardiac valves. Non-significant regurgitation of the mitral, aortic, and tricuspid valves was observed. The pulmonary regurgitation (PR) was considered significant. Dilatation of the right ventricle with preserved systolic function was also noted. A cardiac magnetic resonance confirmed the findings of the echocardiogram and determined a severe PR (regurgitant fraction of 41%). The physical examination revealed hyperlaxity of the joints, skin hyperelasticity, defects in wound healing, and abdominal hernias suggesting EDS. The stress test did not develop any symptoms or complex arrhythmias. In this patient, the heart team initially decided medical treatment and evolutionary control. At the moment, he remains asymptomatic. DISCUSSION: Valvular involvement in EDS is an infrequent event and the compromise of the four cardiac valves is exceptional. The existence of severe PR with a marked increase in ventricular volumes, even in the absence of symptoms, in most cases requires an intervention on the valve. However, in patients with EDS, there are a high rate of complications and interventions should be avoided as much as possible.

5.
Rev. argent. cardiol ; 84(4): 1-10, ago. 2016. ilus
Artigo em Espanhol | LILACS | ID: biblio-957742

RESUMO

Introducción: La insuficiencia mitral de causa degenerativa es una enfermedad de alta prevalencia que, de hecho, constituye la causa más común de necesidad de cirugía sobre la válvula mitral y su resultado está en íntima relación con el tipo de procedimiento que se realice. El ecocardiograma transesofágico tridimensional (3D) permite determinar la complejidad y la extensión del proceso degenerativo y, de este modo, optimizar la estrategia terapéutica. Objetivos: Evaluar las características y las dimensiones del aparato valvular mitral en la insuficiencia mitral degenerativa grave con el propósito de reconocer pacientes con diferente complejidad y extensión de la enfermedad mediante ecocardiograma transesofágico 3D y, asimismo, compararlas con una población sin cardiopatía. Material y métodos: Se incluyeron prospectivamente 25 pacientes con insuficiencia mitral grave degenerativa y 26 pacientes sin enfermedad cardiovascular, a los que se estudió con ecocardiograma transesofágico en 2D y 3D. Con la mejor secuencia 3D se construyó un modelo tridimensional valvular del que se obtuvieron mediciones de las valvas y el anillo (indexadas por la superficie corporal). La población con insuficiencia mitral se dividió en dos grupos: grupo A, compuesto por 17 pacientes con prolapso de un solo segmento y grupo B, conformado por 8 pacientes con más de un segmento con prolapso. Ambas poblaciones se compararon entre sí. Posteriormente se compararon la morfología y las dimensiones del anillo mitral de los pacientes con insuficiencia mitral versus la población sin cardiopatía. Los datos se presentan como mediana con rango intercuartil. En la comparación de los grupos se empleó la prueba de Wilcoxon. Se consideró significativa una p < 0,05 a dos colas. Resultados: El 76% de los pacientes con insuficiencia mitral eran hombres. La edad promedio fue de 60,6 (53-73,2) años. Los pacientes del grupo B presentaron diámetro diastólico del ventrículo izquierdo y anillo mitral con área, circunferencia y diámetro intercomisural significativamente más grandes. El área de la valva anterior y el volumen del prolapso fueron significativamente mayores en el grupo B. Cuando se compararon todos los pacientes con insuficiencia mitral con los pacientes sin cardiopatía, no se observaron diferencias en la morfología del anillo valvular mitral. Conclusiones: En pacientes con insuficiencia mitral grave degenerativa, el ecocardiograma transesofágico 3D permite poner en evidencia diferencias notables entre poblaciones con desigual extensión del compromiso valvular. Los datos así obtenidos podrían tener valor agregado a la hora de decidir la conducta terapéutica.

6.
Rev. argent. cardiol ; 82(4): 297-296, ago. 2014. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-734514

RESUMO

Introducción El ecocardiograma transesofágico en tres dimensiones (ETE 3D) es una herramienta especialmente útil en el estudio de la patología de la válvula mitral. En la bibliografía existe poca información, ninguna de nuestro país, acerca de los valores normales a partir de los cuales se pueda definir la enfermedad. Objetivo Definir los valores normales de las medidas del anillo y de las valvas de la válvula mitral a través del estudio de una población sin cardiopatía utilizando el ETE 3D. Material y métodos Se incluyeron prospectivamente 26 pacientes sin patología cardiovascular que fueron estudiados con ETE en dos y tres dimensiones. Con el mejor volumen 3D adquirido se construyó un modelo tridimensional de la válvula mitral del que se obtuvieron las medidas de las valvas y del anillo (indexadas por superficie corporal). Los datos se presentan como mediana con rango intercuartil. Resultados La edad fue de 64,5 años (39,1-69,7), el 46% eran hombres. Las medidas del anillo mitral fueron: diámetro intercomisural 18,7 mm (16,5-19,9), diámetro anteroposterior 16,4 mm (15,1-17,8), altura 4,4 mm (3,6-5,4), circunferencia en un plano 55,1 mm (52,2-60), circunferencia en 3D 57,8 mm (55,5-64,1), área en un plano 433,9 mm² (405,3-489) y área en 3D 457,8 mm² (431,2-515,8). Las medidas de las valvas fueron: longitud de la valva anterior 13,4 mm (12,4-14), área de la valva anterior 328,6 mm² (297-359,8), longitud de la valva posterior 7,8 mm (7,1-8,3) y área de la valva posterior 242 mm² (214,3-265,5). Se evaluó la reproducibilidad de las mediciones del anillo mitral en 3D y se observó muy buena concordancia tanto intraobservador como interobservador. Conclusiones Los resultados muestran los valores de referencia de las valvas y del anillo de la válvula mitral en una población sin cardiopatía estudiada con ETE 3D. Sientan las bases para futuros estudios que, asociando mediciones similares en todo el rango de gravedad de la patología mitral, permitan definir prospectivamente la sensibilidad y la especificidad del estudio para enfermedad mitral.


Introduction Three-dimensional transesophageal echocardiography (3D TEE) is a useful tool, particularly for the evaluation of mitral valve disease. There are few reports in the literature, none of our country, about the normal values in order to define the disease. Objective The aim of this study was to define the normal values of the mitral valve annulus and leaflets in a population without heart disease using 3D TEE. Methods Twenty-six patients without heart disease were prospectively included and underwent two-dimensional and 3D TEE. The best 3D volume acquired was used to construct a three dimensional model of the mitral valve to measure the mitral valve leaflets and annulus (indexed for body surface area). Data are presented as median with interquartile range. Results Age was 64.5 years (39.1-69.7) and 46% were men. Mitral annulus measurements were: intercommissural diameter 18.7 mm (16.5-19.9), anteroposterior diameter 16.4 mm (15.1-17.8), height 4.4 mm (3.6-5.4), circumference in projection plane 55.1 mm (52.2-60), 3D circumference 57.8 mm (55.5-64.1), area in projection plane 433.9 mm² (405.3-489) and 3D area 457.8 mm² (431.2-515.8). The leaflets measurements were: anterior leaflet length 13.4 mm (12.4-14), anterior leaflet area 328.6 mm² (297-359.8), posterior leaflet length 7.8 mm (7.1-8.3) and posterior leaflet area 242 mm² (214.3-265.5). The reproducibility of mitral annulus measurements in 3D was evaluated and showed good intraobserver and interobserver agreement. Conclusions Results show reference values of the mitral valve leaflets and annulus estimated by 3D TEE in a population without heart disease. These data lay the foundations for future studies which, by associating similar measurements across all the ranges of severity of mitral valve disease, may prospectively define the sensitivity and specificity of the method for mitral valve assessment.

7.
World J Cardiol ; 4(3): 84-6, 2012 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-22451857

RESUMO

Brugada syndrome is a major cause of sudden death in young adults. Fever has been described to induce a Brugada-type electrocardiogram in asymptomatic patients with a negative family history, to disclose Brugada syndrome and to increase the risk of death and induce T wave alternans in patients with diagnosed Brugada syndrome. Risk stratification is challenging and demands a careful evaluation. Here we present 2 case reports and review the literature.

8.
Cardiovasc Ultrasound ; 5: 1, 2007 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-17201908

RESUMO

BACKGROUND: The occurrence of pulmonary artery obstruction in the course of acute aortic dissection is an unusual complication. The mechanism implicated is the rupture of the outer layer of the aorta and the subsequent hemorrhage into the adventitia of the pulmonary artery that causes its wall thickening and, at times, produces extrinsic obstruction of the vessel. There are no reports of this complication in acute intramural hematoma. CASE PRESENTATION: An 87-year-old woman was admitted to the hospital in shock after having had severe chest pain followed by syncope. An urgent transesophageal echocardiogram revealed the presence of acute intramural hematoma, no evidence of aortic dissection, severe pericardial effusion with cardiac tamponade, and periaortic hematoma that involved the pulmonary artery generating circumferential wall thickening of its trunk and right branch with no evidence of flow obstruction. Urgent surgery was performed but the patient died in the operating room. The post mortem examination, in the operating room, confirmed that there was an extensive hematoma around the aorta and beneath the adventitial layer of the pulmonary artery, with no evidence of flow obstruction. CONCLUSION: This is the first time that this rare complication is reported in the scenario of acute intramural hematoma and with the transesophageal echocardiogram as the diagnostic tool.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Ecocardiografia Transesofagiana , Hematoma/complicações , Hematoma/diagnóstico por imagem , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/etiologia , Doença Aguda , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Doenças da Aorta/complicações , Feminino , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA