Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
J Vasc Surg Cases Innov Tech ; 10(5): 101580, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39234560

RESUMO

Cone-beam computed tomography (CBCT) is widely used for the technical assessment of standard and complex endovascular aortic interventions. Use of iodinated contrast in CBCT imaging might provide useful additional information; however, this also increases the procedural contrast dose, which may cause renal function deterioration, and the radiation exposure. We describe the technique and feasibility of carbon-dioxide (CO2)-enhanced CBCT for the technical assessment of standard and complex endovascular aortic repair. In our experience CO2-CBCT had no related adverse events and provided satisfactory imaging quality to assess endograft integrity, vessels patency, and was safely performed in case of severe chronic renal insufficiency.

2.
J Vasc Surg ; 2024 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-39159889

RESUMO

BACKGROUND: Intravenous thrombolysis (IVT) is the mainstay of treatment for patients presenting with acute ischemic stroke, whereas carotid endarterectomy (CEA) is indicated in patients with symptomatic carotid stenosis. However, the impact of prior IVT on the outcomes of CEA (IVT-CEA) is not clear. The aim of this study was to determine whether IVT may create additional stroke and death risk for CEA, compared with CEA performed in the absence of a history of recent IVT, and to determine the optimal timing for CEA after IVT. METHODS: We conducted a systematic review and meta-analysis of studies comparing the outcomes of IVT-CEA vs CEA, using the Medline, Embase, and Cochrane databases. RESULTS: We included 11 retrospective comparative studies, in which 135,644 patients underwent CEA and 2070 underwent IVT-CEA. The pooled rate of perioperative stroke was 4.2% in the IVT-CEA group and 1.3% in the CEA group (odds ratio [OR], 0.44; 95% confidence interval [CI], 0.12-1.58; P = .21), with a high heterogenicity (I2 = 93%). The rate of stroke/death was 5.9% in patients undergoing IVT-CEA 1.9% in those receiving CEA only (OR, 0.42; 95% CI, 0.15-1.14; I2 = 92%; P = .09); after exclusion of studies including TIA as presenting symptom, stroke/death risk was 3.6% in IVT-CEA and 3.0% in CEA (OR, 1.42; 95% CI, 0.80-2.53; I2 = 50%; P = .11). The risk of stoke decreased with a delay in the performance of CEA (P = .268). Using results of the metaregression, the calculated delay of CEA that allows for a <6% risk was 4.6 days. Compared with CEA, patients undergoing IVT-CEA had a significantly higher risk of intracranial hemorrhage (2.5% vs 0.1%; OR, 0.11; 95% CI, 0.06-0.21; I2 = 28%; P < .001) and neck hematoma requiring reintervention (3.6% vs 2.3%; OR, 0.61; 95% CI, 0.43-0.85; I2 = 0%; P = .003). CONCLUSIONS: In patients presenting with an acute ischemic stroke, CEA can be safely performed after a prior endovenous thrombolysis, maintaining a stroke/death risk of <6%. After IVT, CEA should be deferred for ≥5 days to minimize the risk for intracranial hemorrhage and neck bleeding.

3.
Life (Basel) ; 14(7)2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-39063553

RESUMO

Background. Readmissions rates and costs were analysed over follow-up for patients who underwent open or endovascular procedures for aorto-iliac occlusive disease (AIOD). Methods. Patients who underwent aorto-bifemoral bypass (ABF) or covered kissing stent (CKS) for AIOD from May 2008 to February 2018 were compared in terms of readmission rates, related costs expressed in EUR, freedom from generic readmission (FFGR), and freedom from readmission for surgical reasons (FFRS). Results. ABF had a readmission rate of 16% and CKS of 18% (p = 0.999). The most common cause of readmission was prosthesis limb or stent occlusion. Time to readmission was longer for ABF (35 months [21-82] vs. 13.5 months [1-68.7] in the CKS group, p = 0.334). CKS group had higher cumulative re-hospitalisation, ICU stay, and reintervention costs (11569 ± 2216 SEM, 2405 ± 1125, 5264 ± 1230, respectively) and a trend for more readmissions in the first 36 months, without reaching significance. Conclusion. This study reports on a period of time exceeding ninety days. Even if not reaching significance, the CKS group presented a higher trend in readmissions till 36 months and a higher trend in readmission costs, while time-to-readmission was longer in the ABF group.

4.
J Vasc Surg Cases Innov Tech ; 10(4): 101517, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39034961

RESUMO

The aim is to describe the technical feasibility, early outcomes, and graft stability of the Excluder iliac branch endoprosthesis (W.L. Gore & Associates) used as an infrarenal abdominal bifurcated endograft in cases unsuitable for standard endovascular aortic repair. The technique was used in 13 cases with abdominal and/or iliac aneurysms (n = 6), occlusive disease (n = 3), or complex aneurysms in association with a proximal fenestrated/branched endograft (n = 4). Technical success was 100%, and there were no adverse events, with 100% graft stability at 3 months. This case series demonstrates, in extremely selected cases, the feasibility and safety of Excluder iliac branch endoprosthesis used as an infrarenal aortic bifurcated device.

5.
J Vasc Surg ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38908806

RESUMO

OBJECTIVE: The aim of this study was to report the outcomes of endovascular urgent thoracoabdominal aortic (TAAA) repair, using an off-the-shelf preloaded inner branch device (E-nside; Artivion). METHODS: Data from a physician-initiated national multicenter registry, including patients treated with E-nside endograft (INBREED) were prospectively collected (2020-2024); only urgent cases were included in this study. Primary outcomes were technical success and mortality at 30 days. Secondary outcomes were spinal cord ischemia rate, stroke rate, major adverse events (MAE) as also branch instability at 12 months. RESULTS: Of 185 patients enrolled in the INBREED, 64 (34.5%) were treated in a urgent setting and were included in the study. Reason for urgent repair was presence of aneurysm-related symptoms in 31 patients (48.4%), a contained rupture in eight (12.5%), and a large aneurysm >80 mm in 25 (39.1%). Extent of repair was I to III in 32 patients (50%) and IV in 32 (50%); 18 (28%) had a narrow (<25 mm) paravisceral aortic lumen. An adjunctive proximal thoracic endograft was deployed in 29 patients (45.3%); a distal bifurcated abdominal endograft was used in 33 (51.5%). Two hundred forty-nine target vessels (97.2%) were successfully incorporated through an inner branch from an upper arm (81.2%) or femoral (18.8%) access. A balloon expandable stent was used in 184 (75.7%) target vessels, a self-expandable stent in 59 (24.3%). Mean time for target vessel bridging was 39.9 ± 28.4 minutes per target vessel. Thirty-day cumulative major adverse event (MAE) rate was 28%, and mortality occurred in five patients (9.1%). There was one postoperative stroke (1.6%), and the spinal cord ischemia (SCI) rate was 8% (n = 5). For the 249 target vessels successfully incorporated through an inner branch, 1-year freedom from target vessel instability was 93% ± 3% after 1 year. CONCLUSIONS: The E-nside represents a valid solution for the urgent treatment of TAAAs, including symptomatic and ruptured TAAAs, as well as large asymptomatic TAAAs that cannot wait for a custom-made device. The preloaded inner branches and available proximal and distal graft diameters might be useful in urgent settings and provided satisfactory early and 1-year results, in terms of both endograft and target vessel stability. Further studies are required to assess the clinical role of E-nside for urgent TAAA repair.

6.
J Vasc Surg Cases Innov Tech ; 10(3): 101491, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38699664

RESUMO

We describe the feasibility and safety of a standardized approach for four-fenestrated physician-modified endograft (PMEG) placement to treat complex abdominal aortic aneurysms using the Valiant Captivia platform (Medtronic). The standardization is based on specific selection criteria for anatomical feasibility, measurement method, and modification technique of a single endograft type. Six cases (two juxtarenal, two pararenal, and two type IV thoracoabdominal aneurysms) were treated, with 24 target vessels incorporated with fenestrations. Four cases were treated in an urgent setting and two were elective. The time modification required was 121 ± 18 minutes. Technical success was 100%, with no mortality or complications at 30 days. Postoperative computed tomography at 3 months demonstrated complete aneurysm exclusion, without a type I or III endoleak, no main graft- or fenestration-related loss of integrity, and no target vessel misalignment or stent fracture. The present standardized approach seems safe and feasible and might represent an initial benchmark for comparison with future studies.

7.
Eur J Vasc Endovasc Surg ; 68(1): 50-59, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38636923

RESUMO

OBJECTIVE: This study aimed to compare two commercially available off the shelf branched endografts for thoraco-abdominal aortic aneurysm (TAAA) repair, namely the E-nside (Artivion) and Zenith t-Branch (Cook Medical) devices. METHODS: This multicentre retrospective study (2020 - 2023) included patients treated by branched endovascular aortic repair (BEVAR) for TAAA using the inner branched E-nside or the outer branched t-Branch. Endpoints were 30 day technical success and major adverse events (MAEs) as well as one year freedom from target vessel instability and main endograft instability. RESULTS: The study included 163 patients: 79 (307 target vessels) treated with E-nside and 84 (325 target vessels) with t-branch. Aneurysm extent was I - III in 91 patients (55.8%; 47% of E-nside and 66% of t-Branch) and IV in 72 patients (44.2%; 53% of E-nside and 34% of t-Branch) (p = .011). An adjunctive proximal thoracic endograft was used in 43% of E-nside vs. 69% of t-Branch (p < .001), with less frequent thoracic endografting (14% vs. 76%; p < .001) and shorter length of coverage (p = .024) in extent IV TAAA treated by E-nside. E-nside cases had shorter renal artery bridging lengths (66 ± 17 mm vs. 76 ± 20 mm; p < .010) and less frequent use of a distal bifurcated endograft (53% vs. 80%; p < .001). Comparing 30 day results, the mortality rate was 1% vs. 2% (p = .62), any MAE occurred in 18% vs. 21% (p = .55), the stroke rate was 3% vs. 0% (p = .23), and the elective spinal cord ischaemia rate was 5% vs. 8% (p = .40) for E-nside and t-Branch, respectively. At one year, freedom from target vessel instability was 96 ± 3% for E-nside and 95 ± 3% for t-Branch (p = .58), and freedom from endograft instability was 98 ± 2% vs. 97 ± 3% (p = .46), respectively. CONCLUSION: Both off the shelf devices provided excellent early and one year results. The E-nside may require shorter thoracic aortic coverage and bridging length for the renal arteries, and less frequent implantation of a concomitant proximal thoracic or distal abdominal bifurcated endograft. However, these aspects did not determine significant differences in clinical outcomes.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Complicações Pós-Operatórias , Desenho de Prótese , Humanos , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Estudos Retrospectivos , Feminino , Masculino , Idoso , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Fatores de Tempo , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Stents
8.
J Vasc Surg ; 80(2): 441-450, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38485070

RESUMO

OBJECTIVE: The aim of this study was to evaluate the role of intravascular ultrasound (IVUS) for the technical assessment of kissing stents (KSs) and covered endovascular reconstruction of the aortic bifurcation (CERAB) in the treatment of aortoiliac obstructive disease involving the aortic bifurcation. METHODS: We conducted a single-center retrospective review of patients undergoing endovascular treatment of severe aorto-iliac obstructive disease (2019-2023). IVUS was performed in patients treated by KSs or CERAB according to preoperative indications, in cases of moderate/severe calcifications, mural thrombus, total occlusions, and lesion extension towards the proximity of renal or hypogastric arteries. Indications for IVUS-guided intraoperative revisions were residual stenosis or compression >30%, incomplete stent-to-wall apposition, or flow-limiting dissection at the landing site. Follow-up assessment was performed at 6 and 12 months, and then yearly. Thirty-day outcomes and 2-year patency rates were evaluated. Logistic regression was used to identify factors associated with significant technical defects detected by IVUS needing intraoperative revision. RESULTS: IVUS was used for the technical assessment of 102 patients treated by KSs (n = 57; 56%) or CERAB (n = 45; 44%) presenting with severe intermittent claudication (39%), rest pain (39%), or ischemic tissue loss (25%). Twenty-nine significant technical defects were identified by IVUS in 25 patients (25%) who then had successful intraoperative correction by additional ballooning (n = 23; 80%) or stenting (n = 6; 20%). Patients with a severely calcified chronic total occlusion (odds ratio, 1.85; 95% confidence interval, 1.01-5.27; P = .044) or severely calcified narrow aortic bifurcation with <12 mm diameter (odds ratio, 2.34; 95% confidence interval, 1.10-8.64; P = .032) were at increased risk for IVUS-guided intraoperative revision. There were no postoperative deaths and no major adverse events. Two-year primary patency was 100%. CONCLUSIONS: IVUS was used for the technical assessment of KSs/CERAB in a selected cohort of patients with severe aorto-iliac obstructive disease. This allowed the identification and intraoperative correction of a significant technical defect not detected by completion angiogram in one-quarter of patients, achieving optimal 2-year results. IVUS assessment of KSs/CERAB may be considered especially in patients with a calcified total occlusion or narrow aortic bifurcation.


Assuntos
Doenças da Aorta , Procedimentos Endovasculares , Artéria Ilíaca , Stents , Ultrassonografia de Intervenção , Grau de Desobstrução Vascular , Humanos , Estudos Retrospectivos , Masculino , Feminino , Idoso , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Resultado do Tratamento , Pessoa de Meia-Idade , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Doenças da Aorta/fisiopatologia , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Artéria Ilíaca/cirurgia , Fatores de Tempo , Idoso de 80 Anos ou mais , Valor Preditivo dos Testes , Fatores de Risco , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/fisiopatologia , Arteriopatias Oclusivas/cirurgia
9.
Healthcare (Basel) ; 12(1)2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38201025

RESUMO

BACKGROUND: Carotid artery stenting (CAS) using first-generation single-layer stents is widely accepted as a good alternative to standard carotid endarterectomy (CEA) but it is associated with worse outcomes in terms of both plaque prolapse and cerebral embolization. AIM: To evaluate the perioperative and midterm outcomes of CAS using the new-generation RoadsaverTM dual-layer micromesh-covered carotid stent. METHODS: Herein, we present the results of an observational, retrospective, multicentric study on non-consecutive patients who underwent the CAS procedure between January 2017 and December 2022 at three Italian, high-volume vascular surgery centers. The inclusion criteria were the patients' eligibility for the CAS procedure in accordance with the current Italian guidelines, and the implantation of a Roadsaver stent. Both symptomatic and asymptomatic patients were included in the study. The patients requiring reintervention for carotid restenosis following CEA were also included. Perioperative data regarding procedural success was defined as the successful implantation of the device in the desired position, less than 30% residual stenosis, and the absence of intraoperative neurological complications. The primary outcome was any adverse cerebrovascular event such as stroke or transient ischemic attack (TIA) during the procedure and/or after discharge. The secondary outcomes were the need for further intervention, and all-cause death following procedure. RESULTS: Three-hundred-fifty-three (353) patients were included in our study; the mean age was 74.3 years. A total of 5.9% of the patients were symptomatic on their operated side, while 7.3% had contralateral carotid occlusion. A cerebral embolic protection device (CPD) was employed in all patients. A total of 13.3% of the patients were operated on for restenosis after CEA Technical success was achieved in 96.9% of the cases with an intraoperative report of six TIAs (1.7%) and six ipsilateral strokes (1.7%). The mean hospital stay was 1.8 days. The thirty-day follow up showed one TIA and one more stroke. At the mean 35-month follow-up time, the primary outcome was present in six patients (1.7%), where four TIAs (1.1%) and two strokes (0.5%) were reported. Restenosis occurred in five patients (1.4%). Death for any cause was reported in 11 patients (3.1%). CONCLUSIONS: As most recent, high-quality studies show, the CAS procedure with second-generation devices such as the Roadsaver stent is safe and effective in preventing carotid-related cerebrovascular events in both symptomatic and asymptomatic patients. The intraoperative and postoperative cerebrovascular complication rate in high volume centers is very low, ensuring confidence in its employment for the CAS procedure along with a CPD as a valid alternative to CEA.

10.
J Vasc Surg ; 79(2): 217-227.e1, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37852334

RESUMO

OBJECTIVE: To investigate the effect of narrow paravisceral aorta (NPA) on target vessel instability (TVI) after fenestrated-branched endovascular aortic repair. METHODS: We conducted a single-center retrospective study (2014-2023) of patients treated by fenestrated-branched endovascular aortic repair for thoracoabdominal aortic aneurysms (TAAA) or pararenal aortic aneurysms. The paravisceral aorta was defined as the aortic segment limited by the diaphragmatic hiatus proximally and the emergence of lower renal artery distally, and was considered "narrow" in case of a minimum inner diameter of <25 mm. The minimum aortic diameter, location, longitudinal extension, angulation, calcification, and thrombus thickness of NPA were evaluated at the preoperative computed tomography angiogram. End points were 30-day technical success and freedom from TVI. RESULTS: There were 142 patients with JRAA/pararenal aortic aneurysm (n = 85 [59%]) and extent IV (n = 24 [17%]) or extent I-III (n = 33 [23%]) TAAA, with 513 target arteries successfully incorporated through a fenestration (n = 294 [57%]) or directional branch (n = 219 [43%]). A NPA was present in 95 patients (70%), 73 (86%) treated by fenestrated endovascular aortic repair (FEVAR) and 22 (39%) by branched endovascular aortic repair (BEVAR). The overall 30-day mortality was 2% and technical success was 99%, without differences between NPA and non-NPA (P = .99). Kaplan-Meier estimated freedom from TVI at 4 years was 82%, 81% (95% CI, 75-95) in patients with a NPA and 80% (95% CI, 68-94) and in those without NPA (P = .220). The result was maintained for both FEVAR (NPA: 81% [95% CI, 62-88]; non-NPA: 76% [95% CI, 60-99]; P = .870) and BEVAR (NPA: 77% [95% CI, 69-99]; non-NPA: 80% [95% confidence interval (CI) 66-99]; P = .100). After multivariate analysis, the concomitant presence of a NPA <20 mm and angulation of >30° was significantly associated with TVI in FEVAR (HR, 3.21; 95% CI, 1.03-48.70; P = .036), being the result mostly driven by target vessel occlusion. In BEVAR, a NPA diameter of <25 mm was not associated with TVI (HR, 2.02; 95% CI, 0.59-5.23; P = .948); after multivariate analysis, the use of outer branches in case of a NPA longitudinal extension of >25 mm (hazard ratio [HR], 3.02; 95% CI, 1.01-36.33; P = .040) and NPA severe calcification (HR, 1.70; 95% CI, 1.00-22.42; P = .048) were associated with a higher chance for TVI. CONCLUSIONS: FEVAR and BEVAR are both feasible in cases of NPA and provide satisfactory target vessels durability. The use of outer branches should be avoided in cases with an inner aortic diameter of <25 mm with a longitudinal extension of >25 mm or moderate to severe NPA calcifications. In FEVAR, bridging stent patency may be negatively influenced by NPA of <20 mm in association with aortic angulation of >30°.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Correção Endovascular de Aneurisma , Prótese Vascular , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Aorta/cirurgia
11.
J Vasc Surg ; 79(2): 207-216.e4, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37804955

RESUMO

OBJECTIVE: The aim of this study was to investigate the outcomes of primary determinate and indeterminate target vessel endoleaks (TVELs) after fenestrated-branched endovascular aortic repair (F-BEVAR). METHODS: We conducted a single-center retrospective study (2014-2023) on F-BEVAR for thoracoabdominal (TAAAs) or pararenal aortic aneurysms (PRAAs). TVELs were classified as "primary" if present at the first postoperative computed tomography angiogram. Endoleaks were defined "determinate" (dELs) if the cause (type Ic or IIIc) and implicated target vessel were identifiable and "indeterminate" (iELs) if contrast enhancement was detectable at the level of fenestrations/branches without any evident source. Endoleaks involving multiple inflows (type II and target vessels) were defined as "complex" (cELs). Endpoints were endoleak spontaneous resolution, 1-year aneurysm sac failure to regress (>5 mm diameter decrease), and 4-year endoleak-related secondary interventions. Kaplan-Meier estimates and Cox regression were used for the analysis. RESULTS: There were 142 patients with JRAAs/PRAAs (n = 85; 60%) or TAAAs (n = 57; 40%), with 513 target arteries incorporated through a fenestration (n = 294; 57%) or directional branch (n = 219; 43%). Fifty-nine primary TVELs (12%) were identified in 35 patients (25%), a dEL in 20 patients (14%) and iEL in 15 (11%); 22 (15%) had a determinate or indeterminate cEL. Overall spontaneous resolution rate was 75% (95% confidence interval [CI], 51%-87%) at 4 years. cELs (odds ratio [OR], 5.00; 95% CI, 1.10-49.4; P < .001) and iELs after BEVAR (OR, 9.43; 95% CI, 3.41-56.4; P = .002) were more likely to persist >6 months, and persistent forms were associated with sac failure to regress at 1 year (OR, 1.72; 95% CI, 1.03-12.59; P = .040). Overall freedom from endoleak-related reinterventions was 85% (95% CI, 79%-92%) at 4 years, 92% (95% CI, 87%-97%) for those without primary TVELs and 62% (95% CI, 46%-84%) for those with any primary TVEL (P < .001). In particular, cELs (hazard ratio, 1.94; 95% CI, 1.4-18.81; P = .020) were associated with an increased need for reintervention. In case a secondary intervention was needed, iEL or cEL had an increased risk for multiple secondary procedures (hazard ratio, 2.67; 95% CI, 1.22-10.34; P = .034). CONCLUSIONS: Primary TVELs are frequent after F-BEVAR, and a clear characterization of the endoleak source by computed tomography angiogram is not possible in 40% of patients. Most primary TVELs spontaneously resolve, but during follow-up, patients with any primary TVEL experience a worsened freedom from endoleak-related reinterventions that is mostly driven by persistence of cELs and post-BEVAR iELs. Multiple secondary procedures may be required in case of iELs or cELs.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/terapia , Correção Endovascular de Aneurisma , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Fatores de Tempo , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Prótese Vascular/efeitos adversos
12.
J Cardiovasc Surg (Torino) ; 65(1): 49-63, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38037721

RESUMO

The objective of these Guidelines is to provide recommendations for the classification, indication, treatment and management of patients suffering from aneurysmal pathology of the visceral and renal arteries. The methodology applied was the GRADE-SIGN version, and followed the instructions of the AGREE quality of reporting checklist. Clinical questions, structured according to the PICO (Population, Intervention, Comparator, Outcome) model, were formulated, and systematic literature reviews were carried out according to them. Selected articles were evaluated through specific methodological checklists. Considered Judgments were compiled for each clinical question in which the characteristics of the body of available evidence were evaluated in order to establish recommendations. Overall, 79 clinical practice recommendations were proposed. Indications for treatment and therapeutic options were discussed for each arterial district, as well as follow-up and medical management, in both candidate patients for conservative therapy and patients who underwent treatment. The recommendations provided by these guidelines simplify and improve decision-making processes and diagnostic-therapeutic pathways of patients with visceral and renal arteries aneurysms. Their widespread use is recommended.


Assuntos
Aneurisma , Embolização Terapêutica , Humanos , Artéria Renal/diagnóstico por imagem , Radiologia Intervencionista , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Embolização Terapêutica/efeitos adversos , Itália
13.
J Endovasc Ther ; : 15266028231212131, 2023 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-37990854

RESUMO

PURPOSE: To describe the endovascular treatment of a symptomatic juxtarenal abdominal aortic aneurysm (JAAA) using a combination of endoanchors (Heli-FX EndoAnchor, Medtronic, Minneapolis, Minnesota) and a physician-modified single-fenestrated endograft. TECHNIQUE: An 85 year-old patient unfit for open aortic repair presented for a symptomatic JAAA, characterized by an infrarenal neck with 0.6 cm in length and 23 mm in diameter. A 28 mm-diameter Endurant aortic cuff (Medtronic, Minneapolis, Minnesota) was modified with a single fenestration for the left renal artery (LRA) and diameter-reducing tie, then re-sheathed and deployed. The LRA was cannulated with a 7F sheath and the constraining wire was withdrawn. Being the shortest neck length on the right side of the cuff, the endograft was anchored to the aortic wall on this side with 2 endoanchors. The LRA was stented and flared, then a distal physician-modified (without free-flow) bifurcated Endurant graft (Medtronic, Minneapolis, Minnesota) was overlapped with the proximal cuff and stabilized with 6 endoanchors. Correct positioning with complete aneurysm exclusion was confirmed with a 30 day and 9 month computed tomography angiograms. CONCLUSIONS: In extremely selected cases, association of endoanchors and single-fenestrated physician-modified graft may be useful to treat complex urgent aortic aneurysm using readily available devices. CLINICAL IMPACT: This technical note demonstrates the feasibility of a single-fenestrated physician-modified Endurant endograft deployed in combination with endosuture fixation (FESAR), to urgently treat a juxtarenal aortic aneurysm unfit for open repair and not suitable for standard endovascular repair nor off-the-shelf endografts.

14.
J Cardiovasc Surg (Torino) ; 64(6): 561-569, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38015553

RESUMO

Carotid artery stenting (CAS) represents today an accepted option for the treatment of severe carotid artery stenosis. The evolution of materials, techniques, perioperative medical management and patients' selection, has allowed to progressively reduce CAS complications. However, the main drawback of CAS is still represented by the risk of cerebral embolization, that may occur during several steps of the procedure and also in the early postoperative period. Preoperative carotid plaque morphological characteristics may have a great role in determining the risk of embolization during CAS. This review summarizes the current knowledge on carotid plaque characteristics that may influence the risk of complication during CAS. This information may be important for the optimization of CAS patients' selection and adaptation of the materials and techniques.


Assuntos
Estenose das Carótidas , Embolização Terapêutica , Endarterectomia das Carótidas , Placa Aterosclerótica , Humanos , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Stents , Artérias Carótidas , Placa Aterosclerótica/complicações , Placa Aterosclerótica/terapia , Endarterectomia das Carótidas/métodos , Resultado do Tratamento , Fatores de Risco
15.
Artigo em Inglês | MEDLINE | ID: mdl-37858703

RESUMO

OBJECTIVE: This single centre, retrospective study (2014 - 2022) on juxta-, pararenal, or thoraco-abdominal aortic aneurysms treated by fenestrated endovascular aortic repair (FEVAR) was conducted to investigate the clinical impact and determinants of fenestration to target vessel misalignment in FEVAR. METHODS: Pre-operative supracoeliac, pararenal, and infrarenal aortic angles were measured on three dimensional computed tomography angiography (CTA) reconstructions. Two components of misalignment were measured on the first post-operative CTA: horizontal misalignment (angle between the fenestration and the target vessel ostium on perpendicular CTA cuts) and vertical misalignment (vertical distance between the fenestration and the target vessel at its origin). Endpoints were freedom from target vessel instability (TVI) and alignment change over time. RESULTS: Of 65 patients treated by FEVAR, 60 (202 target arteries) with juxta-, pararenal (80%), or thoraco-abdominal aortic aneurysm (20%) were included. Mean horizontal misalignment was 9 ± 12° (median 5°; IQR 0 - 16) and mean vertical misalignment was 0.7 ± 1 mm (median 0 mm, IQR 0 - 1). Freedom from TVI was 92% (95% CI 88 - 98) at 36 months. Horizontal misalignment > 15° was significantly associated with TVI (HR 5.19; 95% CI 1.54 - 17.48; p = .008); vertical misalignment did not significantly impact TVI (HR 0.99; 95% CI 0.56 - 1.73; p = .97). By multivariable analysis, pararenal aortic angle (OR 1.01 per increased degree of angulation; 95% CI 1.00 - 1.02; p = .044), bridging distance > 5 mm (OR 1.07; 95% CI 1.02 - 1.11; p = .003), and use of higher profile endografts in tortuous iliac access (OR 7.55; 95% CI 4.55 - 1.11; p = .003) were associated with clinically significant misalignment. Bridging distance > 5 mm (OR 2.00; 95% CI 1.02 - 11.29; p = .044), degree of baseline misalignment (OR 1.04; 95% CI 1.01 - 1.08; p = .036), and persistence of any primary endoleak for > 6 months (OR 5.85; 95% CI 1.23 - 29.1; p = .023) were associated with misalignment increase during follow up. CONCLUSION: Horizontal misalignment > 15° is associated with worsened target vessel outcomes. This may occur as a result of excessive iliac access tortuosity, high pararenal aortic angulation, and bridging distance > 5 mm.

17.
Stroke ; 54(10): 2534-2541, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37593847

RESUMO

BACKGROUND: The carotid stent design may influence the risk of embolization during carotid artery stenting. The aim of the study was to assess this risk by comparing the quantity of embolized material captured by filters during carotid artery stenting, using different stent designs. METHODS: We conducted a single-center retrospective study of patients undergoing carotid artery stenting for asymptomatic carotid stenosis >70% (2010-2022) in a tertiary academic hospital (Padua University Hospital, Italy). Carotid stents were classified according to their design as open-cell (OCS), closed-cell (CCS), or micromesh stents (MMS). A distal filter protection was used in all patients, and the amount of captured embolized particles was semiautomatically analyzed using a dedicated software (Image-Pro Plus, Media Cybernetics). Primary end point was embolic filter debris (EFD) load, defined as the ratio of the filter area covered by particulate material to the total filter area. Secondary end points were 30 days major stroke and death. RESULTS: Four-hundred-eighty-one carotid artery stentings were included; 171 (35%) using an OCS, 68 (14%) a CCS, and 242 (50%) a MMS. Thirty-days mortality was 0.2% (n=1) and major stroke rate was 0.2% (P=0.987). Filters of patients receiving MMS were more likely to be free from embolized material (OCS, 30%; CCS, 13%; MMS, 41%; P<0.001) and had a lower EFD load (OCS, 9.1±14.5%; CCS, 7.9±14.0%; MMS, 5.0±9.1%; P<0.001) compared with other stent designs. After stratification by plaque characteristics, MMS had a lower EFD load in cases of hypoechogenic plaque (OCS, 13.4±9.9%; CCS, 10.9±8.7%; MMS, 6.5±13.1%; P<0.001), plaque length>15 mm (OC, 10.2±15.3; CC, 8.6±12.4; MM, 8.2±13.6; P<0.001), and preoperative ipsilateral asymptomatic ischemic cerebral lesion (OCS, 12.9±16.8%; CCS, 8.7±19.5%; MMS, 5.4±9.7%; P<0.001). After multivariate linear regression, use of MMS was associated with lower EFD load (P=0.038). CONCLUSIONS: The use of MMS seems to be associated with a lower embolization rate and EFD load, especially in hypoechogenic and long plaques and in patients with a preoperative evidence of asymptomatic ischemic cerebral lesion.


Assuntos
Estenose das Carótidas , Dispositivos de Proteção Embólica , Embolia , Placa Aterosclerótica , Acidente Vascular Cerebral , Humanos , Estenose das Carótidas/cirurgia , Estenose das Carótidas/complicações , Estudos Retrospectivos , Resultado do Tratamento , Stents/efeitos adversos , Embolia/complicações , Acidente Vascular Cerebral/complicações , Placa Aterosclerótica/complicações , Artérias Carótidas/cirurgia , Artérias Carótidas/patologia
18.
J Vasc Surg Cases Innov Tech ; 9(3): 101215, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37408941

RESUMO

We describe the feasibility of a technique for temporary aneurysm sac reperfusion after endovascular single-stage thoracoabdominal aortic aneurysm exclusion, to be used in the case of postoperative spinal cord ischemia. Two cases were treated for impending rupture of a thoracoabdominal aortic aneurysm. Before completion of sac exclusion, a supplementary buddy wire (V-18 control guidewire; Boston Scientific) was advanced in parallel fashion from the left percutaneous femoral access into the aneurysmal sac on the posterior aspect of the endograft. Distal aneurysm exclusion was completed using the main superstiff guidewire, and the femoral access was closed with a percutaneous closure device (ProGlide; Abbott) in standard fashion, leaving in place the sole V-18 guidewire, draped in sterile fashion. In the case of spinal cord ischemia, the "safe-line" can be rapidly used for spinal reperfusion after trans-sealing exchange with a 6F, 65-cm-long Destination sheath (Terumo) connected to a 6F introducer on the contralateral femoral artery.

20.
Diagnostics (Basel) ; 13(11)2023 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-37296807

RESUMO

Background. The aim of this study was to assess the incidence of two post-operative acute kidney injury (AKI) stages according to the Risk, Injury, Failure, Loss of function, End-stage (RIFLE) criteria in patients undergoing fenestrated endovascular aortic repair (FEVAR) for complex aortic aneurysms. Furthermore, we analyzed predictors of post-operative AKI and mid-term renal function deterioration and mortality. Methods. We included all patients who underwent elective FEVAR for abdominal and thoracoabdominal aortic aneurysms between January 2014 and September 2021, independently from their preoperative renal function. We registered cases of post-operative acute kidney injury (AKI) both at risk (R-AKI) and injury stage (I-AKI) according to the RIFLE criteria. Estimated glomerular filtration rate (eGFR) was noted preoperatively, at the 48th post-operative hour, at the maximum post-operative peak, at discharge, and then during follow-up approximately every six months. Predictors of AKI were analyzed with univariate and multivariate logistic regression models. Predictors of mid-term chronic kidney disease (CKD) (stage ≥ 3) onset and mortality were analyzed using univariate and multivariate Cox proportional hazard models. Results. Forty-five patients were included in the present study. Mean age was 73.9 ± 6.1 years and 91% of patients were males. Thirteen patients (29%) presented with a preoperative CKD (stage ≥ 3). Post-operative I-AKI was detected in five patients (11.1%). The aneurysm diameter, thoracoabdominal aneurysms and chronic obstructive pulmonary disease were identified as predictors of AKI in univariate analysis (OR 1.05, 95% CI [1.005-1.20], p = 0.030; OR 6.25, 95% CI [1.03-43.97], p = 0.046; OR 7.43, 95% CI [1.20-53.36], p = 0.031; respectively), yet none of these factors were significative on multivariate analysis. Predictors of CKD onset (stage ≥3) during follow-up on multivariate analysis were age (HR 1.16, 95% CI [1.02-1.34], p = 0.023), post-operative I-AKI (HR 26.82, 95% CI [4.18-218.10], p < 0.001) and renal artery occlusion (HR 29.87, 95% CI [2.33-309.05], p = 0.013), while aortic-related reinterventions where not significantly associated with this outcome in univariate analysis (HR 0.66, 95% CI [0.07-2.77], p = 0.615). Mortality was influenced by preoperative CKD (stage ≥3) (HR 5.68, 95% CI [1.63-21.80], p = 0.006) and post-operative AKI (HR 11.60, 95% CI [1.70-97.51], p = 0.012). R-AKI did not represent a risk factor for CKD (stage ≥ 3) onset (HR 1.35, 95% CI [0.45-3.84], p = 0.569) or for mortality (HR 1.60, 95% CI [0.59-4.19], p = 0.339) during follow-up. Conclusions. In-hospital post-operative I-AKI represented the main major adverse event in our cohort, influencing CKD (≥ stage 3) onset and mortality during follow-up, which were not influenced by post-operative R-AKI and aortic-related reinterventions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA