RESUMO
Coronary artery obstruction caused by sinus sequestration is well described after transcatheter aortic valve implantation in failed bioprosthetic valves, which usually occurs during or shortly after the transcatheter aortic valve implantation procedure. We report the presentation, management, and outcomes of 2 cases of very late sinus sequestration in native aortic annuli, which has not been described before to our knowledge. (Level of Difficulty: Advanced.).
RESUMO
PURPOSE OF REVIEW: Percutaneous structural interventions have provided patients with an effective therapeutic option, and its growth has been aided by echocardiography. We describe the vital role that transesophageal echocardiography (TEE) plays in screening patients prior to their procedure. RECENT FINDINGS: A multimodality imaging approach is employed by the valve team, but TEE plays a unique role in diagnosis and planning. Utilization of all TEE views and features such as biplane, 3D imaging, and multiplanar reconstruction ensures accurate assessment of the structural lesion of interest. The role of TEE remains essential in the planning of structural interventions, and these studies should be performed in a systematic and comprehensive manner.
Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Tridimensional , Humanos , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Tridimensional/métodos , Imagem MultimodalRESUMO
BACKGROUND: Women have a higher rate of adverse events after mitral valve surgery. We sought to evaluate whether outcomes after transcatheter edge-to-edge repair intervention by sex have similar trends to mitral valve surgery. METHODS: The primary outcome was 1-year major adverse events defined as a composite of all-cause mortality, stroke, and any bleeding in the overall study cohort. Patients who underwent transcatheter edge-to-edge repair for mitral regurgitation with the MitraClip system in the Society of Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapy registry were evaluated. Linked administrative claims from the Centers for Medicare and Medicaid Services were used to evaluate 1-year clinical outcomes. Associations between sex and outcomes were evaluated using a multivariable logistic regression model for in-hospital outcomes and Cox model for 1-year outcomes. RESULTS: From November 2013 to March 2017, 5295 patients, 47.6% (n=2523) of whom were female, underwent transcatheter edge-to-edge repair. Females were less likely to have >1 clip implanted (P<0.001) and had a lower adjusted odds ratio of device success (adjusted odds ratio, 0.78 [95% CI, 0.67-0.90]), driven by lower odds of residual mitral gradient <5 mm Hg (adjusted odds ratio, 0.54 [CI, 0.46-0.63]) when compared with males. At 1-year follow-up, the primary outcome did not differ by sex. Female sex was associated with lower adjusted 1-year risk of all-cause mortality (adjusted hazard ratio, 0.80 [CI, 0.68-0.94]), but the adjusted 1-year risk of stroke and any bleeding did not differ by sex. CONCLUSIONS: No difference in composite outcome of all-cause mortality, stroke, and any bleeding was observed between females and males. Adjusted 1-year all-cause mortality was lower in females compared with males.
Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Medicare , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Sistema de Registros , Resultado do Tratamento , Estados Unidos/epidemiologiaRESUMO
OBJECTIVES: The aim of this study was to clarify the dynamics of the mitral annulus throughout the cardiac cycle and its relevance to transcatheter mitral valve replacement (TMVR) sizing and case selection. BACKGROUND: Limited data are available regarding the relevance of mitral annular (MA) and neo-left ventricular outflow tract (LVOT) dynamics in the overall population presenting with significant mitral valve disease. METHODS: Patients attending a combined surgical-transcatheter heart valve clinic for severe symptomatic mitral valve disease were assessed using multiphase computed tomography. The relative influence of MA and neo-LVOT dynamics to TMVR case selection was studied. RESULTS: A total of 476 patients with significant mitral valve disease were evaluated. In 99 consecutive patients with severe mitral regurgitation, a 10-phase assessment showed that the mitral annulus was on average largest in late systole. On comparing maximal MA dimension with late systolic dimension, TMVR size assignment changed in 24.2% of patients. If the average MA perimeter was used to determine sizing, 48.5% were excluded because of MA dimension being too large; in a multiphase assessment of the neo-LVOT, an additional 16.2% were excluded on the basis of neo-LVOT dimension. In an expanded series of 312 consecutive patients, selection protocol influenced anatomical exclusion: a manufacturer-proposed early systolic approach excluded 69.2% of patients, whereas a late systolic approach excluded 82.7% of patients, the vast majority because of large mitral annuli. CONCLUSIONS: Contemporary TMVR can treat only a minority of patients with severe mitral regurgitation, principally because of limitations of large MA dimension.
Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Obstrução do Fluxo Ventricular Externo , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do TratamentoRESUMO
BACKGROUND: Acquired pulmonary vein stenosis (PVS) is an infrequent complication of atrial fibrillation ablation that is often misdiagnosed due to predominant respiratory symptoms. It can result in pulmonary venous hypertension, with varying presentations, ranging from shortness of breath to haemoptysis. CASE SUMMARY: We report two patients with a history of paroxysmal atrial fibrillation treated with radiofrequency ablation and pulmonary vein (PV) isolation, who subsequently developed PVS. Case 1 initially presented with indolent symptoms of shortness of breath and cough. He was initially diagnosed with and treated for pneumonia. In contrast, Case 2 presented with massive haemoptysis, requiring intubation and intensive care unit admission. Both patients were eventually diagnosed with PVS by computed tomography. They were treated with PV angioplasty and stenting. DISCUSSION: While previously limited to the congenital heart disease population, PVS is occurring more frequently now in adult patients as a complication of ablation procedures. It is most effectively treated with angioplasty and stent implantation but has a high rate of recurrence.
RESUMO
OBJECTIVES: To describe the use of orbital atherectomy to prepare iliofemoral vessels for large-bore access prior to transcatheter aortic valve replacement (TAVR). BACKGROUND: Transfemoral (TF)-TAVR has been shown to be at least equivalent to surgery. Nevertheless, many patients do not qualify for the TF approach due to severe iliofemoral occlusive disease. The use of an atherectomy device in order to facilitate TF-TAVR has only been reported in case reports. METHODS: We performed 1000 TAVR procedures from June 2017 to October 2019. Patient demographics, procedural characteristics, computed tomography characteristics, and short-term outcomes were recorded. Hostile access was defined as luminal size <5 mm, or <5.5 mm along with the presence of >270° calcification. The primary endpoint was the ability to successfully deliver a transcatheter valve via the intended pretreated access site. RESULTS: During the study period, 6 subjects (0.6%) required alternative access and 68 patients (6.8%) were considered to have a hostile iliofemoral anatomy that required vessel preparation prior to TAVR. Forty-eight patients (70.6%) had angioplasty only and 20 patients (29.4%) required atherectomy and angioplasty. Out of 20 patients treated with atherectomy, successful TF delivery of the valve was achieved in 19 patients (95%). There was no in-hospital mortality or stroke. There were no perforations. One subject required placement of a self-expandable stent due to severe dissection. CONCLUSION: Orbital atherectomy used for vessel preparation is a safe and very effective technique to facilitate TF-TAVR in patients with hostile peripheral anatomy.
Assuntos
Estenose da Valva Aórtica , Aterectomia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Humanos , Fatores de Risco , Resultado do TratamentoAssuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anticoagulantes/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Falha de Prótese , Tomografia , Resultado do TratamentoRESUMO
Left ventricular outflow tract (LVOT) obstruction in hypertrophic cardiomyopathy (HCM) is often caused by systolic anterior motion (SAM) of the mitral valve caused by the interplay between increased left ventricular (LV) wall thickness and an abnormal mitral valve anatomy and geometry. Three-dimensional (3D) echocardiographic imaging of the mitral valve has revolutionized the practice of cardiology, paving the way for new methods to see and treat valvular heart disease. Here we present the novel and incremental value of 3D transesophageal echocardiography (TEE) of SAM visualization. This review first provides step-by-step instructions on acquiring and optimizing 3D TEE imaging of SAM. It then describes the unique and novel findings using standard 3D TEE rendering as well as dynamic mitral valve modeling of SAM from 3D data sets, which can provide a more detailed visualization of SAM features. The findings include double-orifice LVOT caused by the residual leaflet, the dolphin smile phenomenon, and delineation of SAM width. Finally, the review discusses the essential role of 3D TEE imaging for preprocedural assessment and intraprocedural guidance of surgical and novel percutaneous treatments of SAM.
Assuntos
Cardiomiopatia Hipertrófica , Ecocardiografia Tridimensional , Obstrução do Fluxo Ventricular Externo , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Humanos , Valva Mitral/diagnóstico por imagem , Sístole , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagemRESUMO
BACKGROUND: Patients with renal insufficiency have poor short-term outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Retrospective chart review identified 575 consecutive patients not on hemodialysis who underwent TAVR between September 2014 and January 2017. Outcomes were defined by VARC-2 criteria. Primary outcome of all-cause mortality was evaluated at a median follow-up of 811 days (interquartile range 125-1,151). RESULTS: Preprocedural glomerular filtration rate (GFR) was ≥60 ml/min in 51.7%, 30-60 ml/min in 42.1%, and < 30 ml/min in 6.3%. Use of transfemoral access (98.8%) and achieved device success (91.0%) did not differ among groups, but less contrast was used with lower GFR (23 ml [15-33], 24 ml [14-33], 13 ml [8-20]; p < .001). Peri-procedural stroke (0.7%, 2.1%, 11.1%; p < .001) was higher with lower GFR. Core lab analysis of preprocedural computed tomography scans of patients who developed a peri-procedural stroke identified potential anatomic substrate for stroke in three out of four patients with GFR 30-60 ml/min and all three with GFR <30 ml/min (severe atheroma was the most common subtype of anatomical substrate present). Compared to GFR ≥60 ml/min, all-cause mortality was higher with GFR 30-60 ml/min (HR 1.61 [1.00-2.59]; aHR 1.61 [0.91-2.83]) and GFR <30 ml/min (HR 2.41 [1.06-5.48]; aHR 2.34 [0.90-6.09]) but not significant after multivariable adjustment. Follow-up echocardiographic data, available in 63%, demonstrated no difference in structural heart valve deterioration over time among groups. CONCLUSIONS: Patients with baseline renal insufficiency remain a challenging population with poor long-term outcomes despite procedural optimization with a transfemoral-first and an extremely low-contrast approach.
Assuntos
Estenose da Valva Aórtica , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
INTRODUCTION: Previous studies have suggested that women with chroniclimb-threatening ischemia (CLTI) may have worse outcomes than men. The aim of this study was to determine whether there are sex-related differences in outcomes of patients with CLTI undergoing endovascular treatment with current endovascular technologies. PATIENTS AND METHODS: Data were derived from the LIBERTY 360 study (NCT01855412). Hazard ratios and the respective 95% confidence intervals were synthesized to examine the association between sex and all-cause mortality, target vessel revascularization (TVR), major amputation, major adverse event (MAE) and major amputation/death up to 3 years of follow-up. RESULTS: A total of 689 patients with CLTI (female: N=252 vs male: N=437) treated with any FDA approved or cleared device were included. The mean lesion length was 126.9±117.3mm and 127.4±113.3mm for the female and male patients, respectively. Although a slightly higher incidence of in-hospital mortality was observed in the female group (1.2% vs 0.0%, p=0.049), there was no difference in female vs male survival rates during follow-up. However, the risk of major amputation at 18 months was higher for the male group (male vs female: HR: 2.36; 95% CI: 1.09-5.12; p=0.030). No difference between the two groups was detected in terms of TVR or MAE during follow-up. DISCUSSION: Data regarding sex-related disparity in outcomes after endovascular therapy of patients with CLTI are conflicting. Gender-related characteristics rather than biological sex characteristics might be the cause of these conflicting findings. Further studies are needed to evaluate the role of sex in revascularization outcomes among this high-risk population.
Assuntos
Angioplastia com Balão , Isquemia/terapia , Doença Arterial Periférica/terapia , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/mortalidade , Causas de Morte , Doença Crônica , Feminino , Mortalidade Hospitalar , Humanos , Isquemia/diagnóstico , Isquemia/mortalidade , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/mortalidade , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Resultado do TratamentoRESUMO
Glucose 6-phosphate dehydrogenase (G6PD) deficiency facilitates human coronavirus infection due to glutathione depletion. G6PD deficiency may especially predispose to hemolysis upon coronavirus disease-2019 (COVID-19) infection when employing pro-oxidant therapy. However, glutathione depletion is reversible by N-acetylcysteine (NAC) administration. We describe a severe case of COVID-19 infection in a G6PD-deficient patient treated with hydroxychloroquine who benefited from intravenous (IV) NAC beyond reversal of hemolysis. NAC blocked hemolysis and elevation of liver enzymes, C-reactive protein (CRP), and ferritin and allowed removal from respirator and veno-venous extracorporeal membrane oxygenator and full recovery of the G6PD-deficient patient. NAC was also administered to 9 additional respirator-dependent COVID-19-infected patients without G6PD deficiency. NAC elicited clinical improvement and markedly reduced CRP in all patients and ferritin in 9/10 patients. NAC mechanism of action may involve the blockade of viral infection and the ensuing cytokine storm that warrant follow-up confirmatory studies in the setting of controlled clinical trials.
Assuntos
Acetilcisteína/uso terapêutico , Antioxidantes/uso terapêutico , Betacoronavirus/patogenicidade , Infecções por Coronavirus/tratamento farmacológico , Síndrome da Liberação de Citocina/tratamento farmacológico , Deficiência de Glucosefosfato Desidrogenase/tratamento farmacológico , Pneumonia Viral/tratamento farmacológico , Adulto , Antirreumáticos/uso terapêutico , Biomarcadores/sangue , Proteína C-Reativa/metabolismo , COVID-19 , Infecções por Coronavirus/sangue , Infecções por Coronavirus/complicações , Infecções por Coronavirus/virologia , Síndrome da Liberação de Citocina/sangue , Síndrome da Liberação de Citocina/complicações , Síndrome da Liberação de Citocina/virologia , Esquema de Medicação , Ferritinas/sangue , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Deficiência de Glucosefosfato Desidrogenase/sangue , Deficiência de Glucosefosfato Desidrogenase/complicações , Deficiência de Glucosefosfato Desidrogenase/virologia , Humanos , Hidroxicloroquina/uso terapêutico , Inflamação/prevenção & controle , Masculino , Pandemias , Pneumonia Viral/sangue , Pneumonia Viral/complicações , Pneumonia Viral/virologia , SARS-CoV-2 , Resultado do TratamentoRESUMO
OBJECTIVES: This study sought to minimize the risk of permanent pacemaker implantation (PPMI) with contemporary repositionable self-expanding transcatheter aortic valve replacement (TAVR). BACKGROUND: Self-expanding TAVR traditionally carries a high risk of PPMI. Limited data exist on the use of the repositionable devices to minimize this risk. METHODS: At NYU Langone Health, 248 consecutive patients with severe aortic stenosis underwent TAVR under conscious sedation with repositionable self-expanding TAVR with a standard approach to device implantation. A detailed analysis of multiple factors contributing to PPMI was performed; this was used to generate an anatomically guided MInimizing Depth According to the membranous Septum (MIDAS) approach to device implantation, aiming for pre-release depth in relation to the noncoronary cusp of less than the length of the membranous septum (MS). RESULTS: Right bundle branch block, MS length, largest device size (Evolut 34 XL; Medtronic, Minneapolis, Minnesota), and implant depth > MS length predicted PPMI. On multivariate analysis, only implant depth > MS length (odds ratio: 8.04; 95% confidence interval: 2.58 to 25.04; p < 0.001) and Evolut 34 XL (odds ratio: 4.96; 95% confidence interval: 1.68 to 14.63; p = 0.004) were independent predictors of PPMI. The MIDAS approach was applied prospectively to a consecutive series of 100 patients, with operators aiming to position the device at a depth of < MS length whenever possible; this reduced the new PPMI rate from 9.7% (24 of 248) in the standard cohort to 3.0% (p = 0.035), and the rate of new left bundle branch block from 25.8% to 9% (p < 0.001). CONCLUSIONS: Using a patient-specific MIDAS approach to device implantation, repositionable self-expanding TAVR achieved very low and predictable rates of PPMI which are significantly lower than previously reported with self-expanding TAVR.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Estimulação Cardíaca Artificial , Bloqueio Cardíaco/terapia , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/etiologia , Bloqueio Cardíaco/fisiopatologia , Humanos , Masculino , Cidade de Nova Iorque , Estudos Prospectivos , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
BACKGROUND: While most self-expanding transcatheter valves are repositionable, only one fully retrievable valve is currently available. The Meridian valve is a new self-expanding valve with full retrievability properties. The objective of our study was to evaluate the early feasibility, preliminary safety, and efficacy of transcatheter aortic valve replacement with the HLT Meridian valve (HLT, Inc). METHODS: This was a multicenter early feasibility study including patients with severe aortic stenosis at high surgical risk undergoing transfemoral transcatheter aortic valve replacement with the 25-mm Meridian valve. All serious adverse events were adjudicated by an independent clinical events committee according to Valve Academic Research Consortium-2 criteria. Echocardiography data were assessed by an independent echocardiography core laboratory. RESULTS: A total of 25 patients (mean age, 85±6 years; 80% of men) were included. The valve was successfully implanted in 22 (88%) patients (annulus too large and extreme horizontal aorta in 2 and 1 unsuccessful cases, respectively). Valve retrieval because of an initial nonadequate positioning was attempted and successfully performed in 10 (40%) patients. Echocardiography post-transcatheter aortic valve replacement showed a low mean residual gradient (10±4 mm Hg) and the absence of moderate-severe aortic regurgitation (none-trace and mild aortic regurgitation in 76% and 24% of patients, respectively). Mortality at 30 days was 8%, with no cases of disabling stroke, valve embolization, or major/life-threatening bleeding complications. At 6-month follow-up, the cumulative mortality rate was 12%, with no changes in echocardiographic parameters and no cases of valve dysfunction. The majority of patients (89%) were in New York Heart Association class I-II at 6 months. CONCLUSIONS: Transcatheter aortic valve replacement with the Meridian valve was feasible and associated with acceptable early and 6-month clinical results. Valve retrieval after full valve deployment was successfully performed in all attempted cases, and valve performance was excellent, with low residual gradients, no cases of moderate-severe aortic regurgitation, and none-trace residual aortic regurgitation in the majority of patients. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02838680 (RADIANT-Canada); NCT02799823 (RADIANT-US).
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Canadá , Estudos de Viabilidade , Feminino , Humanos , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados UnidosRESUMO
INTRODUCTION: A common complication of transcatheter aortic valve repair (TAVR) is development of conduction defects requiring pacemaker (PPM) implantation. These defects are not universally permanent. OBJECTIVE: To determine the incidence and predictors of persistent device dependency in patients with PPM implantation following TAVR with a self-expanding prosthesis. METHODS: Records of patients who underwent post-TAVR PPM implantation were reviewed. Patients with persistent complete AV block (AVBIII) one month post-TAVR were compared to those regaining conduction. RESULTS: Between September 2014 and March 2017, 485 patients underwent TAVR with a self-expanding prosthesis; 77 (15.9%) underwent PPM implantation for AVBIII. Device interrogation at one month was available for 61 patients (79%): 22 (36.1%) had resolution of AVBIII while 39 (63.9%) remained pacemaker-dependent. Pre-TAVR right bundle branch block was more frequent in device-dependent patients (19 of 38, 50% vs 4 of 22, 18%; RR 2.75; P = .01). Device-dependence was associated with AVBIII as the first postprocedural rhythm (37 of 39, 95% vs 12 of 22, 55%; RR 1.74; P < .0001), earlier implantation (median 1d, IQR: 0-1.5d vs 2d, IQR: 1.0-4.0d, P = .0004), and a shorter duration of hospitalization (median 3d, IQR: 2-3.5d vs 4d, IQR: 2-5.75d, P = .03). Pacemaker dependence was also associated with a higher prosthesis-to left ventricular outflow tract (LVOT) diameter (1.45 ± 0.11 vs 1.39 ± 0.07; P = .02) and the lack of prior aortic valvuloplasty (5 of 39, 13% vs 8 of 22, 36%; RR 0.35; P = .03). CONCLUSIONS: In patients receiving a PPM following self-expanding TAVR, a long-term pacing requirement can be predicted from the timing of AV block, existing conduction-system disease, larger prosthesis-to-LVOT diameter, and the lack of aortic valvuloplasty.
Assuntos
Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/etiologia , Prótese Vascular , Marca-Passo Artificial , Complicações Pós-Operatórias/etiologia , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Eletrocardiografia , Feminino , Humanos , Masculino , Desenho de Prótese , Fatores de RiscoRESUMO
BACKGROUND: Thrombocytopenia after transcatheter aortic valve replacement (TAVR) is associated with adverse clinical outcomes. Whether preprocedural P2Y12 inhibition prevents postprocedural thrombocytopenia is uncertain. METHODS: This retrospective analysis identified consecutive patients (n = 266) undergoing TAVR between November 2016 and July 2017. Preprocedure clopidogrel load ≥300 mg or maintenance P2Y12 inhibitor therapy defined preprocedural P2Y12 inhibition. Patients who did not consent for the registry (n = 8), with baseline severe thrombocytopenia (<90 × 103 platelets/µL; n = 14), or without baseline platelet count (n = 4) were excluded. The primary outcome was proportion of patients who developed >20% decrease in platelet count from baseline to day 1 post-TAVR. RESULTS: Patients with (n = 134) versus without (n = 106) preprocedural P2Y12 inhibition had no differences in platelet count at baseline. Patients with preprocedural P2Y12 inhibition had a significantly lower proportion of the primary outcome (34.3% vs. 57.5%, p = .001) and a lower absolute decrease in platelet count (32.8 × 103 vs. 45.8 × 103 platelet/µL, p = .01). Of patients without baseline thrombocytopenia (n = 198), a numerically lower rate of patients with versus without preprocedural P2Y12 inhibition developed thrombocytopenia on day 1 post-TAVR (25.5% vs. 36.4%, p = .1). CONCLUSION: Patients who received preprocedural P2Y12 inhibition prior to TAVR were less likely to demonstrate a decrease in platelet count after TAVR. Prospective studies to further understand the clinical implication of these findings are warranted.
Assuntos
Plaquetas/efeitos dos fármacos , Clopidogrel/administração & dosagem , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Receptores Purinérgicos P2Y12/efeitos dos fármacos , Trombocitopenia/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Plaquetas/metabolismo , Clopidogrel/efeitos adversos , Feminino , Humanos , Masculino , Contagem de Plaquetas , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Receptores Purinérgicos P2Y12/sangue , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Trombocitopenia/sangue , Trombocitopenia/diagnóstico , Trombocitopenia/etiologia , Resultado do TratamentoRESUMO
BACKGROUND: Renal disease is associated with poor prognosis despite guideline-directed cardiovascular therapy, and outcomes by sex in this population remain uncertain. METHODS AND RESULTS: Patients (n=5213) who underwent a MitraClip procedure in the National Cardiovascular Data Registry Transcatheter Valve Therapy registry were evaluated for the primary composite outcome of all-cause mortality, stroke, and new requirement for dialysis by creatinine clearance (CrCl). Centers for Medicare and Medicaid Services-linked data were available in 63% of patients (n=3300). CrCl was <60 mL/min in 77% (n=4010) and <30 mL/min in 23% (n=1183) of the cohort. Rates of primary outcome were higher with lower CrCl (>60 mL/min, 1.4%; 30-<60 mL/min, 2.7%; <30 mL/min, 5.2%; dialysis, 7.8%; P<0.001), and all low CrCl groups were independently associated with the primary outcome (30-<60 mL/min: adjusted odds ratio, 2.32; 95% CI, 1.38-3.91; <30 mL/min: adjusted odds ratio, 4.44; 95% CI, 2.63-7.49; dialysis: adjusted hazards ratio, 4.52; 95% CI, 2.08-9.82) when compared with CrCl >60 mL/min. Rates of 1-year mortality were higher with lower CrCl (>60 mL/min, 13.2%; 30-<60 mL/min, 18.8%; <30 mL/min, 29.9%; dialysis, 32.3%; P<0.001), and all low CrCl groups were independently associated with 1-year mortality (30-<60 mL/min: adjusted hazards ratio, 1.50; 95% CI, 1.13-1.99; <30 mL/min: adjusted hazards ratio, 2.38; 95% CI, 1.78-3.20; adjusted hazards ratio: dialysis, 2.44; 95% CI, 1.66-3.57) when compared with CrCl >60 mL/min. CONCLUSIONS: The majority of patients who undergo MitraClip have renal disease. Preprocedural renal disease is associated with poor outcomes, particularly in stage 4 or 5 renal disease where 1-year mortality is observed in nearly one-third. Studies to determine how to further optimize outcomes in this population are warranted.
Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Nefropatias/fisiopatologia , Rim/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Nefropatias/diagnóstico , Nefropatias/mortalidade , Nefropatias/terapia , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/mortalidade , Estenose da Valva Mitral/fisiopatologia , Desenho de Prótese , Sistema de Registros , Diálise Renal , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Transcatheter aortic valve replacement (TAVR) for low gradient (LG) severe aortic stenosis (AS) with preserved left ventricular ejection fraction (LVEF) remains an area of clinical uncertainty. METHODS: Retrospective review identified 422 patients who underwent TAVR between September 4, 2014 and July 1, 2016. Procedural indication other than severe AS (n = 22) or LVEF <50% (n = 98) were excluded. Outcomes were defined by valve academic research consortium two criteria when applicable and compared between LG (peak velocity <4.0 m/s and mean gradient <40 mmHg; n = 73) and high gradient (HG) (n = 229) groups. The LG group was further categorized as low stroke volume index (SVI) (n = 41) or normal SVI (n = 32). Median follow-up was 747 days [interquartile range 220-1013]. RESULTS: Baseline thirty-day mortality risk (LG 6.2% [3.8-8.1] vs HG 5.7% [4.1-7.4], P = 0.43) did not differ between groups. Short-term outcomes, including procedural success rate (86.1% vs 88.8%, P = 0.53), peri-procedural complications (intra-procedural heart block: 6.8% vs 7.9%, P = 0.99; permanent pacemaker placement: 11.0% vs 13.6%, P = 0.69; moderate paravalvular regurgitation: 2.7% vs 1.3%, P = 0.60), and all-cause in-hospital mortality (2.7% vs 0.9%, P = 0.25) did not differ between LG and HG groups. On long-term follow-up, all-cause mortality also did not differ between LG and HG groups (6.8% vs 10.0%, plog-rank = 0.33) or between the LG low SVI (9.8%), LG normal SVI (3.1%), and HG (10.0%) groups (plog-rank = 0.39). CONCLUSION: Patients with preserved LVEF undergoing TAVR for severe AS with LG, including LG with low SVI, have no significant difference in adverse outcomes when compared to patients with HG.
Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Ecocardiografia , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda/fisiologiaAssuntos
Anticoagulantes/administração & dosagem , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Remoção de Dispositivo/instrumentação , Dispositivos de Proteção Embólica , Coração Auxiliar , Hemotórax/etiologia , Heparina/administração & dosagem , Hemorragia Pós-Operatória/etiologia , Choque Cardiogênico/terapia , Tromboembolia/prevenção & controle , Anticoagulantes/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Esquema de Medicação , Coração Auxiliar/efeitos adversos , Hemotórax/diagnóstico , Heparina/efeitos adversos , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/diagnóstico , Desenho de Prótese , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/fisiopatologia , Tromboembolia/etiologia , Resultado do TratamentoRESUMO
A 78-year-old man with remote type-A dissection presented with acute-onset dyspnea. Twenty-two years prior, treatment for his aortic disease required replacement of ascending and arch aneurysms with a polyester graft (Dacron) using the graft inclusion technique. He presented currently in cardiogenic shock. Echocardiography demonstrated new severe hypokinesis of all apical segments. Left-heart catheterization revealed a 120 mm Hg intragraft gradient. Computed tomography arteriography was unrevealing, but intraaortic ultrasound demonstrated critical intragraft stenosis. A balloon expandable stent (Palmaz stent, Cordis, Milpitas, CA) was deployed in the stenotic region with gradient resolution. The patient later underwent aortic root replacement and ascending aneurysm repair (Bio-Bentall technique) and is doing well at 24 months.