Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Int Orthop ; 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38833167

RESUMO

PURPOSE: Measurement of glenoid bone loss in the shoulder instability can be assessed by CT or MRI multiplanar imaging and is crucial for pre-operative planning. The aim of this study is to determine the intra and interobserver reliability of glenoid deficiency measurement using MRI multiplanar reconstruction with 2D assessment in the sagittal plane (MPR MRI). METHODS: We reviewed MRI images of 80 patients with anterior shoulder instability with Osirix software using MPR. Six observers with basic experience measured the glenoid, erosion edge length, and bone loss twice, with at least one-week interval between measurements. We calculated reliability and repeatability using the intra-class correlation coefficient (ICC) and minimal detectable change with 95% confidence (MDC95%). RESULTS: Intra and Inter-observer ICC and MDC95% for glenoid width and height were excellent (ICC 0,89-0,96). For erosion edge length and area of the glenoid were acceptable/good (ICC 0,61-0,89). Bone loss and Pico Index were associated with acceptable/good ICC (0,63 -0,86)) but poor MDC95% (45 - 84 %). Intra-observer reliability improved with time, while inter-observer remained unchanged. CONCLUSION: The MPR MRI measurement of the anterior glenoid lesion is very good tool for linear parameters. This method is not valid for Pico index measurement, as the area of bone loss is variable. The pace of learning is individual, therefore complex calculations based on MPR MRI are not resistant to low experience as opposed to true 3D CT.

2.
JSES Int ; 8(3): 434-439, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38707554

RESUMO

Background: The glenoid track concept identifies patients with "off-track" (engaging) Hill-Sachs lesions (HSLs) as poor candidates for arthroscopic Bankart repair (ABR) due to the high risk of shoulder instability recurrence. Purpose: To retrospectively calculate the glenoid track index, using preoperative computed tomography (CT) scans, in a cohort of patients with failed ABR. We hypothesized that all patients with a failed ABR would have engaging ("off-track") HSLs on preoperative CT scan. Type of Study: CT scan study. Methods: Preoperative CT scan of 45 patients, seen in our facility for failed ABR, was used to retrospectively calculate the glenoid track index. The risk of recurrence was also calculated for each patient using Instability Severity Index Score (ISI-Score) and Glenoid Track Instability Management Score (GTIMS). There were 37 failed isolated ABRs and 8 associated HS remplissage. The mean t age at surgery was 24 years (range, 15-52) and instability recurred at a mean of 29 months postoperative (range, 3-167). Results: Preoperative CT scan imaging identified "off-track" bony lesions in 85% of patients (38/45) and "on-track" lesions in 15% (7/45). No significant differences were noted between the 2 groups (off-track vs. on-track) regarding patient age, hyperlaxity, sports participation, size of HS lesion, or ISI-Score. The mean glenoid bone loss was 15.7% (range, 4-36%) with mean HS width was greater than 20 mm in 66% of CT scans. The preoperative ISI-Score was predictive of failures (>3 points in all patients) with no difference between on-track and off-track patients (6.3 ± 1.7 vs. 6.6 ± 1.7, P = .453). By contrast, the GTIMS did not predict failures as there was a significant difference between GTIMS for on-track and off-track patients (2.1 ± 1.3 vs. 6.6 ± 1.7). Conclusions: The glenoid track concept alone is insufficient to predict Bankart failures: in the present series of failed ABR, 15% of shoulders had "on-track" (non-engaging) lesions on preoperative CT scan. In patients, with "on-track" bony lesions, the ISI-Score is a useful predictive tool to detect patients at risk of failure, while the GTIMS is not.

4.
Arch Orthop Trauma Surg ; 142(12): 3927-3935, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34964916

RESUMO

INTRODUCTION: Shoulder stability is secured by dynamic and static stabilizers. Rotator cuff is responsible for dynamic stabilization. In cases of shoulder instability their activity is disturbed. Capsulolabral repair restores mainly static stabilization. This surgery treatment technique of shoulder instability was first described by Bankart in 1923. His idea, with further modifications, is commonly used up to this day. Evaluation of muscle shoulder recovery after stabilization should be one of the important criteria to allow patient to return to sport and work. However, not much isokinetic assessment after capsulolabral repair was described. The aim of this study were the following: the comparative assessment of the shoulder rotatory strength in patients following arthroscopic capsulolabral repair of unilateral anterior traumatic instability and clinical assessment with comparison of pre and post-operative results. MATERIAL AND METHODS: Forty-five patients, 14 women and 31 men, with an average follow-up of 4.4 years were tested bilaterally for internal and external rotation strength at four angular velocities. ASES and UCLA tests were collected before and after surgery. RESULTS: The values of peak moment and muscle power parameters were slightly lower for an operated shoulder in comparison to a healthy shoulder for the external rotation. Total work parameter in external rotation was significantly lower for the operated shoulder in comparison to the non-operated side. The internal/external muscle group balance was lower for the operated shoulder in comparison to reference values in the women group. Furthermore, both ASES and UCLA scores were significantly higher after operation. CONCLUSIONS: After arthroscopic capsulolabral shoulder stabilization, slight differences in isokinetic evaluation, especially in external shoulder rotation, occur. It affects rotators muscle balance. In functional evaluation significant improvement in shoulder function occurs.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Masculino , Humanos , Feminino , Instabilidade Articular/etiologia , Instabilidade Articular/cirurgia , Ombro , Articulação do Ombro/cirurgia , Amplitude de Movimento Articular/fisiologia , Artroscopia/métodos , Luxação do Ombro/cirurgia
5.
Nat Commun ; 12(1): 2113, 2021 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-33837202

RESUMO

The accumulation of adenosine is strongly correlated with the need for sleep and the detection of sleep pressure is antagonised by caffeine. Caffeine also affects the circadian timing system directly and independently of sleep physiology, but how caffeine mediates these effects upon the circadian clock is unclear. Here we identify an adenosine-based regulatory mechanism that allows sleep and circadian processes to interact for the optimisation of sleep/wake timing in mice. Adenosine encodes sleep history and this signal modulates circadian entrainment by light. Pharmacological and genetic approaches demonstrate that adenosine acts upon the circadian clockwork via adenosine A1/A2A receptor signalling through the activation of the Ca2+ -ERK-AP-1 and CREB/CRTC1-CRE pathways to regulate the clock genes Per1 and Per2. We show that these signalling pathways converge upon and inhibit the same pathways activated by light. Thus, circadian entrainment by light is systematically modulated on a daily basis by sleep history. These findings contribute to our understanding of how adenosine integrates signalling from both light and sleep to regulate circadian timing in mice.


Assuntos
Adenosina/metabolismo , Transtornos Cronobiológicos/fisiopatologia , Relógios Circadianos/efeitos dos fármacos , Sono/fisiologia , Animais , Encéfalo/patologia , Cafeína/farmacologia , Linhagem Celular Tumoral , Transtornos Cronobiológicos/tratamento farmacológico , Transtornos Cronobiológicos/etiologia , Transtornos Cronobiológicos/patologia , Relógios Circadianos/fisiologia , Ritmo Circadiano/efeitos dos fármacos , Ritmo Circadiano/fisiologia , Modelos Animais de Doenças , Humanos , Luz , Masculino , Camundongos , Camundongos Transgênicos , Proteínas Circadianas Period/genética , Proteínas Circadianas Period/metabolismo , Fotoperíodo , Quinazolinas/administração & dosagem , Receptor A1 de Adenosina/metabolismo , Receptor A2A de Adenosina/metabolismo , Transdução de Sinais/efeitos dos fármacos , Transdução de Sinais/fisiologia , Transdução de Sinais/efeitos da radiação , Sono/efeitos dos fármacos , Privação do Sono/complicações , Triazóis/administração & dosagem
6.
EFORT Open Rev ; 5(11): 815-827, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33312708

RESUMO

The coexistence of glenoid and humeral head bone defects may increase the risk of recurrence of instability after soft tissue repair.Revealed factors in medical history such as male gender, younger age of dislocation, an increasing number of dislocations, contact sports, and manual work or epilepsy may increase the recurrence rate of instability.In physical examination, positive bony apprehension test, catching and crepitations in shoulder movement may suggest osseous deficiency.Anteroposterior and axial views allow for the detection of particular bony lesions in patients with recurrent anterior shoulder instability.Computed Tomography (CT) with multiplanar reconstruction (MPR) and various types of 3D rendering in 2D (quasi-3D-CT) and 3D (true-3D-CT) space allows not only detection of glenoid and humeral bone defects but most of all their quantification and relations (engaging/not-engaging and on-track/off-track) in the context of bipolar lesion.Magnetic resonance imaging (MRI) is increasingly developing and can provide an equally accurate measurement tool for bone assessment, avoiding radiation exposure for the patient. Cite this article: EFORT Open Rev 2020;5:815-827. DOI: 10.1302/2058-5241.5.200049.

7.
EFORT Open Rev ; 5(9): 549-557, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33072407

RESUMO

A synovial plica (fold) is normal anatomic finding, and occurs in 86-100% of cases; however, symptomatic plica is much less common (7.2-8.7% of all elbow arthroscopies).Synovial plica syndrome is a painful elbow condition related to symptomatic synovial plica.Synovial plica syndrome is diagnosed by clinical examination (lateral elbow pain) commonly accompanied by local tenderness, pain at terminal extension and/or painful snapping.Synovial plica syndrome may be mimicked by other elbow conditions, commonly tennis elbow, loose bodies, and degenerative arthritis.Magnetic resonance imaging or ultrasound scan may support diagnosis in correlation with clinical findings, but symptomatic plica may also be diagnosed as unexpected during elbow arthroscopy.The arthroscopic resection is effective and safe if conservative treatment fails. Cite this article: EFORT Open Rev 2020;5:549-557. DOI: 10.1302/2058-5241.5.200027.

8.
Chemosphere ; 254: 126869, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32957283

RESUMO

This paper presents the results of Co(II) and Ni(II) extraction from model and real solutions using bis(2,4,4-trimethylpentyl)phosphinic acid (i.e. Cyanex 272) that are in agreement with waste-to-resources approach, i.e. the recovery of valuable components from wastes. The results from this study shows that, extraction using Cyanex 272 is an efficient method to recover Co(II) selectively from sulfate electrolytes obtained from the leaching of steel scraps of aircraft engines. The highest selectivity value (∼160) of Co(II) extraction over Ni(II) was obtained at a pH of 4.8, the lowest selectivity value (∼30) was observed at a pH of 5.5, while above this value the selectivity only increased slightly with increasing pH. A pH of 5.2 was selected as a compromise between Co(II) selectivity and Ni(II) amount in the organic phase. The essence of the investigation is to propose important parameters to extract Co(II) from real leach solutions, and to further recover valuable Co(II) from the loaded organic phase by stripping with 1 M H2SO4, thus producing an electrolyte of Co(II) for electrowinning - a possible alternative route for resource recovery. Small volume of the stripping phase (w/o = 1:5) used in this study, lead to an enrichment of sulfate electrolyte in Co(II), resulting in ∼50 g/dm3 of Co(II) in the solution, which is a great advantage of the approach proposed. Such a solution is a valuable source for the electrowinning of metallic cobalt, which can be used for the production of steel alloys, Li-ion batteries or catalysts.


Assuntos
Cobalto/química , Modelos Químicos , Níquel/química , Ácidos Fosfínicos/química , Fontes de Energia Elétrica , Lítio , Sulfatos
9.
Int Orthop ; 44(10): 2049-2056, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32712787

RESUMO

PURPOSE: The aim of the study was to compare two measurement methods of humeral head defects in patients with shoulder instability. Intra- and inter-observer reliability of humeral head parameters were performed with the use of 2D and 3D computed tomography. METHODS: The study group was composed of one hundred humeral heads measured with the use of preoperative 2D and 3D computed tomography by three independent observers (two experienced and one inexperienced). All observers repeated measurements after 1 week. The intra-class correlation coefficient (ICC) and the minimal detectable change with 95% confidence (MDC95%) were used for statistical analysis of diagnostic agreement. RESULTS: For 3D inter-observer reliability, ICC values were "excellent" for all parameters and MDC95% values were "excellent" or "reasonable." All intra-observer ICC and MDC95% values for 3D were "excellent" for experienced and inexperienced observers. For 2D-CT, ICC values were usually "good" or "moderate" with MDC95% values higher than 10 or 30%. CONCLUSIONS: Three-dimensional CT measurements are more reliable than 2D for humeral head and Hill-Sachs lesion assessment. This study showed that 2D measurements, even performed by experienced observers (orthopaedic surgeons), are burdened with errors. The 3D reconstruction decreased the risk of error by eliminating inaccuracy in setting the plane of the measurements.


Assuntos
Instabilidade Articular , Articulação do Ombro , Humanos , Cabeça do Úmero/diagnóstico por imagem , Cabeça do Úmero/cirurgia , Imageamento Tridimensional , Instabilidade Articular/diagnóstico por imagem , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Ombro , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X
10.
ACS Med Chem Lett ; 11(4): 403-406, 2020 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-32292539

RESUMO

Measuring and quantifying the binding of a drug to a protein target inside living cells and thereby correlating biochemical or biophysical activity with target engagement in cells or tissue represents a key step in target validation and drug development. A prototypic target engagement assay should allow for unbiased determination of small molecule-protein interactions in order to confirm cellular mechanism-of-action (MoA) while avoiding major artificial perturbations of cellular homeostasis and integrity. Recently, several new additions to the chemical biology toolbox have expanded our ability to study drug action in intact cells and enabled surveying of intracellular residence time and binding kinetics, which are particularly important for potent receptor ligands and therapeutic moieties with limited therapeutic index.

11.
ACS Chem Biol ; 13(10): 2849-2854, 2018 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-30216042

RESUMO

Targeting the protein-protein interaction between p53 and MDM2/MDMX (MDM4) represents an attractive anticancer strategy for the treatment of p53-competent tumors. Several selective and potent MDM2 inhibitors have been developed and entered the clinic; however, the repertoire of MDMX antagonists is still limited. The arylmethylidenepyrazolinone SJ-172550 has been reported as a selective MDMX antagonist; yet, uncertainties about its mechanism of action have raised doubts about its use as a chemical probe. Here, we show that, in addition to its unclear mode of action, SJ-172550 is unstable in aqueous buffers, giving rise to side products of unknown biological activity. Using an SJ-172550-derived affinity probe, we observed promiscuous binding to cellular proteins whereas cellular thermal shift assays did not reveal a stabilizing effect on MDMX. Overall, our results raise further questions about the interpretation of data using SJ-172550 and related compounds to investigate cellular phenotypes.


Assuntos
Acetatos/metabolismo , Inibidores Enzimáticos/metabolismo , Proteínas Nucleares/antagonistas & inibidores , Proteínas Nucleares/metabolismo , Proteínas Proto-Oncogênicas/antagonistas & inibidores , Proteínas Proto-Oncogênicas/metabolismo , Pirazóis/metabolismo , Acetatos/química , Marcadores de Afinidade/química , Alcinos/química , Sítios de Ligação , Carbocianinas/química , Proteínas de Ciclo Celular , Linhagem Celular Tumoral , Química Click , Estabilidade de Medicamentos , Inibidores Enzimáticos/química , Humanos , Proteínas Nucleares/química , Ligação Proteica , Estabilidade Proteica/efeitos dos fármacos , Proteínas Proto-Oncogênicas/química , Pirazóis/química
12.
Oncotarget ; 9(18): 14692-14722, 2018 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-29581875

RESUMO

While many efforts have been made to pave the way toward human space colonization, little consideration has been given to the methods of protecting spacefarers against harsh cosmic and local radioactive environments and the high costs associated with protection from the deleterious physiological effects of exposure to high-Linear energy transfer (high-LET) radiation. Herein, we lay the foundations of a roadmap toward enhancing human radioresistance for the purposes of deep space colonization and exploration. We outline future research directions toward the goal of enhancing human radioresistance, including upregulation of endogenous repair and radioprotective mechanisms, possible leeways into gene therapy in order to enhance radioresistance via the translation of exogenous and engineered DNA repair and radioprotective mechanisms, the substitution of organic molecules with fortified isoforms, and methods of slowing metabolic activity while preserving cognitive function. We conclude by presenting the known associations between radioresistance and longevity, and articulating the position that enhancing human radioresistance is likely to extend the healthspan of human spacefarers as well.

13.
Int Orthop ; 41(1): 149-155, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27540732

RESUMO

PURPOSE: The evaluation of glenohumeral joint volume in both unstable (with/without laxity) and stable shoulders (subacromial impingement) and volume reduction potential of arthroscopic techniques: (labral anchor repair vs. capsular shift). METHODS: Material was based on 133 patients: anterior shoulder instability without laxity (group I, n = 49), with laxity (group II, n = 22) and subacromial impingement (control group, n = 62) operated in 2010-2011. Group I received arthroscopic Bankart repair, group; II - arthroscopic anterior capsular plication, control group - subacromial decompression. Joint volume was measured by fluid aspiration into the syringe via arthroscope, before and after procedure. Then volume reduction potential was calculated. RESULTS: The following average values of initial joint volume were recorded: group I - 26.8 ml group II - 43.7 ml and the control group - 25.6 ml with significant differences: impingement vs. instability + laxity (p < 0.00001), impingement vs. instability without laxity (p = 0.0001). There was no significant difference between groups I and II. Joint volume was significantly reduced after labral repair (by average of 37 %, 13.8 ml, p < 0.0001). Capsular shift led to an even greater and more significant volume decrease (61 %, 26.7 ml, p < 0.001). Joint volume in the control group was reduced only by 11 %, 3.8 ml (p = 0.046). CONCLUSIONS: Patients with unstable shoulders have enlarged joint volume as compared to patients with subacromial impingement. Arthroscopic techniques lead to a significant joint volume reduction, with the most powerful effect for capsular shift. Level of Evidence - Level 2.


Assuntos
Artroscopia/métodos , Instabilidade Articular/cirurgia , Articulação do Ombro/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Articulação do Ombro/patologia , Adulto Jovem
14.
Int Orthop ; 40(12): 2581-2588, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27492723

RESUMO

PURPOSE: The main purpose of this study is to establish which of two methods is more reliable in glenoid assessment for instability in pre-operative planning. Accordingly, we have studied the intra- and inter-observer reliability of glenoid parameters with the use of two-dimensional (2D) and three-dimensional (3D) reconstructed computed tomography (CT) images. METHODS: One hundred glenoids were measured with the use of 2D-CT and 3D-CT (in 3D orientation) by two independent observers (one experienced and one inexperienced). Measurements were repeated after one week for 30 randomly selected glenoids. RESULTS: The intra-class correlation coefficient (ICC) for inter-observer reliability was significantly greater for 3D-CT (0.811 to 0.915) than for 2D-CT (0.523 to 0.925). All intra-observer reliability values for 3D-CT were near perfect (0.835 to 0.997), while those for 2D-CT were less reliable (0.704 to 0.960). A dependent t-test showed that, for both observers, almost all glenoid parameters (except R and d) differed significantly (p < 0.05) between 2D and 3D measurement methods. CONCLUSIONS: Therefore, it can be concluded that 3D glenoid reconstructions are more reliable for glenoid bone loss assessment than 2D-CT. The results suggest that quantifying a glenoid defect with the use of 2D image only-even if performed by an experienced orthopaedic surgeon-is prone to errors. Differences in measurements between and within observers can be explained by plane setting and identifying glenoid rim in 2D-CT. Accordingly, we recommend that glenoid measurements should be performed in 3D orientation using 3D reconstruction obtained from CT images for pre-operative assessments, which are crucial for surgical planning.


Assuntos
Imageamento Tridimensional/métodos , Instabilidade Articular/diagnóstico por imagem , Escápula/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
15.
Eur J Orthop Surg Traumatol ; 23(2): 177-83, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23412449

RESUMO

Proprioception is an essential part of shoulder stability and neuromuscular control. The purpose of the study was the development of a precise system of shoulder proprioception assessment in the active mode (Propriometr). For that purpose, devices such as the electronic goniometer and computer software had been designed. A pilot study was carried out on a control group of 27 healthy subjects, the average age being 23.8 (22-29) in order to test the system. The result of the assessment was the finding of the error of active reproduction of the joint position (EARJP). EARJP was assessed for flexion, abduction, external and internal rotation. For every motion, reference positions were used at three different angles. The results showed EARJP to range in 3-6.1°. The proprioception evaluation system (propriometr) allows a precise measurement of active joint position sense. The designed system can be used to assess proprioception in both shoulder injuries and treatment. In addition, all achieved results of normal shoulders may serve as reference to be compared with the results of forthcoming studies.


Assuntos
Propriocepção/fisiologia , Articulação do Ombro/fisiologia , Adulto , Feminino , Humanos , Instabilidade Articular/fisiopatologia , Masculino , Equipamentos Ortopédicos , Ortopedia/métodos , Amplitude de Movimento Articular , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA