Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Am J Cardiol ; 203: 265-273, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37516034

RESUMO

Current guidelines, supported by limited data, prioritize the use of cardiac resynchronization therapy (CRT) over mitral transcatheter edge-to-edge repair (TEER) in eligible patients. To examine TEER results and outcomes in CRT-eligible patients with functional mitral regurgitation (MR) according to CRT status, we conducted a single-center, retrospective analysis of 126 consecutive patients who underwent TEER while fulfilling guideline criteria for CRT before the procedure. The primary outcome was the composite of all-cause mortality or heart failure hospitalizations at 1 year. The secondary outcomes included individual components of the primary outcome, as well as 1-year all-cause hospitalizations and 1-month MR severity, indexed left atrial volume, and indexed left ventricular mass by echocardiography. A total of 70 patients (56%) did not undergo CRT at the time of TEER. The baseline characteristics and procedural results were mostly comparable between those with and without CRT. The no-CRT group experienced higher rates of the primary outcome (43% vs 25%, p = 0.041), which were accounted for by increased mortality (26% vs 11%, p = 0.033). After multivariable analysis, the absence of CRT was associated with more than twice the risk for the primary outcome (hazard ratio 2.36, 95% confidence interval 1.1 to 4.98, p = 0.0.017), a finding which was confined to patients with a class I indication for the device. Rates of secondary endpoints did not differ between the groups. In conclusion, in CRT-eligible patients who underwent TEER for functional MR, the 1-year clinical outcome was more favorable when the procedure was preceded by CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Resultado do Tratamento , Terapia de Ressincronização Cardíaca/métodos , Seguimentos , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos
2.
Eur Heart J Cardiovasc Imaging ; 22(2): 179-185, 2021 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-33324979

RESUMO

AIMS: Recovery of left ventricular ejection fraction (LVEF) after aortic valve replacement has prognostic importance in patients with aortic stenosis (AS). The mechanism by which myocardial fibrosis impacts LVEF recovery in AS is not well characterized. We sought to evaluate the predictive value of extracellular volume fraction (ECV) quantified by cardiac CT angiography (CTA) for LVEF recovery in patients with AS after transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: In 109 pre-TAVR patients with LVEF <50% at baseline echocardiography, CTA-derived ECV was calculated as the ratio of change in CT attenuation of the myocardium and the left ventricular (LV) blood pool before and after contrast administration. Early LVEF recovery was defined as an absolute increase of ≥10% in LVEF measured by post-TAVR follow-up echocardiography within 6 months of the procedure. Early LVEF recovery was observed in 39 (36%) patients. The absolute increase in LVEF was 17.6 ± 8.8% in the LVEF recovery group and 0.9 ± 5.9% in the no LVEF recovery group (P < 0.001). ECV was significantly lower in patients with LVEF recovery compared with those without LVEF recovery (29.4 ± 6.1% vs. 33.2 ± 7.7%, respectively, P = 0.009). In multivariable analysis, mean pressure gradient across the aortic valve [odds ratio (OR): 1.07, 95% confidence interval (CI): 1.03-1.11, P: 0.001], LV end-diastolic volume (OR: 0.99, 95% CI: 0.98-0.99, P: 0.035), and ECV (OR: 0.92, 95% CI: 0.86-0.99, P: 0.018) were independent predictors of early LVEF recovery. CONCLUSION: Increased myocardial ECV on CTA is associated with impaired LVEF recovery post-TAVR in severe AS patients with impaired LV systolic function.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada , Humanos , Recuperação de Função Fisiológica , Estudos Retrospectivos , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda
3.
JACC Cardiovasc Interv ; 13(22): 2617-2627, 2020 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-33213747

RESUMO

OBJECTIVES: The aim of this study was to evaluate the risk of coronary obstruction due to sinus sequestration in redo transcatheter aortic valve replacement (TAVR) using post-TAVR computed tomography (CT). BACKGROUND: Little information is available regarding the risk of coronary obstruction due to sinus sequestration in redo TAVR inside a previously implanted TAV. METHODS: Post-TAVR CT of 66 patients who received an Evolut R or Evolut PRO and 345 patients who received a SAPIEN 3 were analyzed. Redo TAVR was considered at risk of coronary obstruction due to sinus sequestration if: 1) the prior TAV commissure level was above sinotubular junction (STJ); and 2) the distance between TAV and STJ was <2.0 mm in each coronary sinus. RESULTS: In total, 45.5% in the Evolut R/Evolut PRO group and 2.0% in the SAPIEN 3 group had CT-identified risk of sinus sequestration at 1 or both coronary arteries (p < 0.001). CT-identified risk of sinus sequestration was observed in 39.4% for the left coronary artery and 24.2% for the right coronary artery in the Evolut R/Evolut PRO group, while those percentages were 2.0% for the left coronary artery and 0.6% for the right coronary artery in the SAPIEN 3 group. In a coronary-level analysis, overlaps between the first TAV commissural posts and coronary ostium were observed in 45.2% in the Evolut R/Evolut PRO group and 11.1% in in the SAPIEN 3 group among coronary arteries at CT-identified risk of sinus sequestration. CONCLUSIONS: The risk of sinus sequestration in redo TAVR should be carefully screened by CT, especially in patients with low STJ height. TAV with low commissure height that was designed to achieve commissure-to-commissure alignment with the native aortic valves may be preferable to avoid the risk of coronary obstruction due to sinus sequestration and allow for a preventive leaflet laceration procedure in future redo TAVR. (Assessment of TRanscathetEr and Surgical Aortic BiOprosthetic Valve Thrombosis and Its TrEatment With Anticoagulation [RESOLVE]; NCT02318342).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
4.
JACC Cardiovasc Imaging ; 13(12): 2591-2601, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33129731

RESUMO

OBJECTIVES: The association between extracellular volume (ECV) measured by computed tomography angiography (CTA) and clinical outcomes was evaluated in low-flow low-gradient (LFLG) aortic stenosis (AS) patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Patients with LFLG AS comprise a high-risk group with respect to clinical outcomes. Although ECV, a marker of myocardial fibrosis, is traditionally measured with cardiac magnetic resonance, it can also be measured using cardiac CTA. The authors hypothesized that in LFLG AS, increased ECV may be associated with adverse clinical outcomes. METHODS: In 150 LFLG patients with AS who underwent TAVR, ECV was quantified using pre-TAVR CTA. Echocardiographic and clinical information including all-cause death and heart failure rehospitalization (HFH) was obtained from electronic medical records. A Cox proportional hazards model was used to evaluate the association between ECV and death+HFH. RESULTS: During a median follow-up of 13.9 months (range 0.07 to 28.9 months), there were 31 death+HFH events (21%). Patients who experienced death+HFH had a greater median Society of Thoracic Surgery score (9.9 vs. 4.7; p < 0.01), lower left ventricular ejection fraction (42.3 ± 20.2% vs. 52.7 ± 17.2%; p < 0.01), lower mean transvalvular gradient (24.9 ± 8.9 mm Hg vs. 28.1 ± 7.3 mm Hg; p = 0.04) and increased mean ECV (35.5 ± 9.6% vs. 29.9 ± 8.2%; p < 0.01) compared with patients who did not experience death+HFH. In a multivariable Cox proportional hazards model, increase in ECV was associated with increase in death+HFH, (hazard ratio per 1% increase: 1.04, 95% confidence interval: 1.01 to 1.09; p < 0.01). CONCLUSIONS: In patients with LFLG AS, CTA measured increase in ECV is associated with increased risk of adverse clinical outcomes post-TAVR and may thus serve as a useful noninvasive marker for prognostication.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Prognóstico , Índice de Gravidade de Doença , Volume Sistólico , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Função Ventricular Esquerda
5.
JACC Cardiovasc Interv ; 13(20): 2402-2414, 2020 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-33011141

RESUMO

OBJECTIVES: The primary objective of this study was to evaluate the effectiveness of the MitraClip G4 in the reduction of mitral regurgitation (MR). BACKGROUND: The next-generation MitraClip G4 system was recently introduced for the treatment of MR in the United States. METHODS: The study included consecutive patients undergoing transcatheter mitral edge-to-edge repair for MR with the MitraClip G4. The key outcome was the proportion of patients with MR reduction to ≤2+ at 30 days. RESULTS: Fifty-nine patients (median age 77 years, 62.7% men) were treated with the MitraClip G4. Reduction of MR to ≤2+ was achieved in 57 patients (96.6%) during the procedure, 58 patients (98.3%) at discharge, and 57 patients (96.6%) by 30 days. The median number of MitraClips used per patient was 2 (interquartile range: 1 to 3). Wide clips (NTW/XTW) were used in 82.7% of patients. The XTW clip was used most frequently as the first clip in patients with degenerative MR (65.4%) and the NTW clip in those with secondary MR (72.7%). The independent grasping mechanism was used in 49.2% of patients. CONCLUSIONS: Use of the MitraClip G4 system was associated with excellent reduction in MR to ≤2+ in 96.6% of patients at 30 days. The availability of multiple MitraClip G4 sizes, especially the wide clips, and the ability to independently grasp leaflets are the likely contributors to MR reduction.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Idoso , Feminino , Humanos , Masculino , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
6.
J Am Coll Cardiol ; 61(9): 908-16, 2013 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-23449425

RESUMO

OBJECTIVES: This study compared cross-sectional three-dimensional (3D) transesophageal echocardiography (TEE) to two-dimensional (2D) TEE as methods for predicting aortic regurgitation after transcatheter aortic valve replacement (TAVR). BACKGROUND: Data have shown that TAVR sizing using cross-sectional contrast computed tomography (CT) parameters is superior to 2D-TEE for the prediction of paravalvular aortic regurgitation (AR). Three-dimensional TEE can offer cross-sectional assessment of the aortic annulus but its role for TAVR sizing has been poorly elucidated. METHODS: All patients had severe symptomatic aortic stenosis and were treated with balloon-expandable TAVR in a single center. Patients studied had both 2D-TEE and 3D imaging (contrast CT and/or 3D-TEE) of the aortic annulus at baseline. Receiver-operating characteristic curves were generated for each measurement parameter using post-TAVR paravalvular AR moderate or greater as the state variable. RESULTS: For the 256 patients studied, paravalvular AR moderate or greater occurred in 26 of 256 (10.2%) of patients. Prospectively recorded 2D-TEE measurements had a low discriminatory value (area under the curve = 0.52, 95% confidence interval: 0.40 to 0.63, p = 0.75). Average cross-sectional diameter by CT offered a high degree of discrimination (area under the curve = 0.82, 95% confidence interval: 0.73 to 0.90, p < 0.0001) and mean cross-sectional diameter by 3D-TEE was of intermediate value (area under the curve = 0.68, 95% confidence interval: 0.54 to 0.81, p = 0.036). CONCLUSIONS: Cross-sectional 3D echocardiographic sizing of the aortic annulus dimension offers discrimination of post-TAVR paravalvular AR that is significantly superior to that of 2D-TEE. Cross-sectional data should be sought from 3D-TEE if good CT data are unavailable for TAVR sizing.


Assuntos
Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Próteses Valvulares Cardíacas , Humanos , Curva ROC , Tomografia Computadorizada por Raios X
7.
Future Cardiol ; 7(4): 499-509, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21797746

RESUMO

Transcatheter aortic valve implantation has risen exponentially as a treatment modality for severe aortic stenosis in patients considered to be at high risk for or inoperable by conventional surgical aortic valve replacement. It has shown both survival and quality of life benefit in a randomized comparison to conservative (palliative) therapy in nonoperative candidates. Fundamental to its success is appropriate patient selection and a rigorous attention to procedural steps. In this article we will discuss the key issues pertaining to each of these factors.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Seleção de Pacientes , Bioprótese , Cateterismo Cardíaco , Próteses Valvulares Cardíacas , Humanos , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA