Resultados 1 - 20 de 82
Filtrar
1.
N Engl J Med ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38767244

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

2.
Heart Rhythm ; 21(9): 1686-1694, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38604592

RESUMO

BACKGROUND: The utility of atrioventricular (AV) optimization (AVO) algorithms remains in question. A substudy of the SMART-AV trial found that patients with prolonged interventricular delays ≥70 ms were more likely to benefit from cardiac resynchronization therapy (CRT) with AVO. The SMART-CRT trial evaluated AVO on the basis of these results, but the study was underpowered. OBJECTIVE: To increase statistical power, data from SMART-AV patients meeting the inclusion criterion of interventricular delay ≥70 ms were pooled with data from SMART-CRT to reassess AVO. METHODS: SMART-CRT and SMART-AV were prospective, randomized, multicenter clinical trials. Patients in both studies were randomized to be programmed with an AVO algorithm (SmartDelay) or fixed AV delay (120 ms). Paired echocardiograms obtained at baseline and 6 months were compared, with CRT response defined as ≥15% reduction in left ventricular end-systolic volume. RESULTS: A total of 451 complete patient data sets were pooled and analyzed. The baseline demographics between studies did not differ statistically in terms of age, sex, left ventricular ejection fraction, or left ventricular end-systolic volume. The AVO group had a greater proportion of CRT responders (SmartDelay, 73.9%; fixed, 63.1%; P = .014) and greater changes in measures of reverse remodeling. SmartDelay patients with a recommended sensed AV delay outside the nominal range (100-120 ms) had 2.3 greater odds of CRT response than fixed AV delay patients. CONCLUSION: Greater CRT response and measures of reverse remodeling were observed in patients with SmartDelay enabled vs a fixed AV delay. This study supports the use of SmartDelay in patients with a CRT indication and interventricular delay ≥70 ms.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Feminino , Masculino , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Idoso , Resultado do Tratamento , Estudos Prospectivos , Algoritmos , Ecocardiografia , Volume Sistólico/fisiologia , Pessoa de Meia-Idade , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia
3.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38305503

RESUMO

AIMS: When it occurs, pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is associated with significant morbidity. Even mild-to-moderate PV narrowing may have long-term implications. Unlike thermal ablation energies, such as radiofrequency (RF) or cryothermy, pulsed field ablation (PFA) is a non-thermal modality associated with less fibrotic proliferation. Herein, we compared the effects of PFA vs. thermal ablation on PV narrowing after AF ablation. METHODS AND RESULTS: ADVENT was a multi-centre, randomized, single-blind study comparing PFA (pentaspline catheter) with thermal ablation-force-sensing RF or cryoballoon (CB)-to treat drug-refractory paroxysmal AF. Pulmonary vein diameter and aggregate cross-sectional area were obtained by baseline and 3-month imaging. The pre-specified, formally tested, secondary safety endpoint compared a measure of PV narrowing between PFA vs. thermal groups, with superiority defined by posterior probability > 0.975. Among subjects randomized to PFA (n = 305) or thermal ablation (n = 302), 259 PFA and 255 thermal ablation (137 RF and 118 CB) subjects had complete baseline and 3-month PV imaging. No subject had significant (≥70%) PV stenosis. Change in aggregate PV cross-sectional area was less with PFA (-0.9%) than thermal ablation (-12%, posterior probability > 0.999)-primarily driven by the RF sub-cohort (-19.5%) vs. CB sub-cohort (-3.3%). Almost half of all PFA PV diameters did not decrease, but the majority (80%) of RF PVs decreased, regardless of PV anatomic location. CONCLUSION: In this first randomized comparison of PFA vs. thermal ablation, PFA resulted in less PV narrowing-thereby underscoring the qualitatively differential and favourable impact of PFA on PV tissue.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Estenose de Veia Pulmonar , Humanos , Veias Pulmonares/cirurgia , Constrição Patológica/complicações , Constrição Patológica/cirurgia , Método Simples-Cego , Resultado do Tratamento , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/etiologia
4.
N Engl J Med ; 389(18): 1660-1671, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37634148

RESUMO

BACKGROUND: Catheter-based pulmonary vein isolation is an effective treatment for paroxysmal atrial fibrillation. Pulsed field ablation, which delivers microsecond high-voltage electrical fields, may limit damage to tissues outside the myocardium. The efficacy and safety of pulsed field ablation as compared with conventional thermal ablation are not known. METHODS: In this randomized, single-blind, noninferiority trial, we assigned patients with drug-refractory paroxysmal atrial fibrillation in a 1:1 ratio to undergo pulsed field ablation or conventional radiofrequency or cryoballoon ablation. The primary efficacy end point was freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation. The primary safety end point included acute and chronic device- and procedure-related serious adverse events. RESULTS: A total of 305 patients were assigned to undergo pulsed field ablation, and 302 were assigned to undergo thermal ablation. At 1 year, the primary efficacy end point was met (i.e., no events occurred) in 204 patients (estimated probability, 73.3%) who underwent pulsed field ablation and 194 patients (estimated probability, 71.3%) who underwent thermal ablation (between-group difference, 2.0 percentage points; 95% Bayesian credible interval, -5.2 to 9.2; posterior probability of noninferiority, >0.999). Primary safety end-point events occurred in 6 patients (estimated incidence, 2.1%) who underwent pulsed field ablation and 4 patients (estimated incidence, 1.5%) who underwent thermal ablation (between-group difference, 0.6 percentage points; 95% Bayesian credible interval, -1.5 to 2.8; posterior probability of noninferiority, >0.999). CONCLUSIONS: Among patients with paroxysmal atrial fibrillation receiving a catheter-based therapy, pulsed field ablation was noninferior to conventional thermal ablation with respect to freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation and with respect to device- and procedure-related serious adverse events at 1 year. (Funded by Farapulse-Boston Scientific; ADVENT ClinicalTrials.gov number, NCT04612244.).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/classificação , Fibrilação Atrial/cirurgia , Teorema de Bayes , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva , Método Simples-Cego , Taquicardia/etiologia , Resultado do Tratamento
5.
Heart Rhythm O2 ; 4(7): 448-456, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37520021

RESUMO

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has demonstrated safety and efficacy for the treatment of malignant ventricular arrhythmias. However, a limitation of the S-ICD lies in the inability to either pace-terminate ventricular tachycardia or provide prolonged bradycardia pacing support. Objective: The rationale and design of a prospective, single-arm, multinational trial of an intercommunicative leadless pacing system integrated with the S-ICD will be presented. Methods: A technical description of the modular cardiac rhythm management (mCRM) system (EMPOWER leadless pacemaker and EMBLEM S-ICD) and the implantation procedure is provided. MODULAR ATP (Effectiveness of the EMPOWER™ Modular Pacing System and EMBLEM™ Subcutaneous ICD to Communicate Antitachycardia Pacing) is a multicenter, international trial enrolling up to 300 patients at risk of sudden cardiac death at up to 60 centers trial design. The safety endpoint of freedom from major complications related to the mCRM system or implantation procedure at 6 months and 2 years are significantly higher than 86% and 81%, respectively, and all-cause survival is significantly >85% at 2 years. Results: Efficacy endpoints are that at 6 months mCRM communication success is significantly higher than 88% and the percentage of subjects with low and stable thresholds is significantly higher than 80%. Substudies to evaluate rate-responsive features and performance of the pacing module are also described. Conclusion: The MODULAR ATP global clinical trial will prospectively test the safety and efficacy of the first intercommunicating leadless pacing system with the S-ICD. This trial will allow for robust validation of device-device communication, pacing performance, rate responsiveness, and system safety.

7.
Circ Arrhythm Electrophysiol ; 16(6): e011714, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37183700

RESUMO

BACKGROUND: The role of atrioventricular optimization (AVO) to improve cardiac resynchronization therapy outcomes remains controversial. Previous post hoc analyses of a multicenter trial showed that measures of electrical dyssynchrony (right ventricular-left ventricular [LV] or LV electrical delay durations) are associated with patients who benefit from AVO. METHODS: This was a global, multicenter, prospective, randomized trial of de novo cardiac resynchronization therapy implant patients with an right ventricular-LV duration ≥70 ms to determine whether AVO results in greater reverse remodeling. Patients were randomized 1:1 for either an AVO algorithm (SmartDelay) that determines atrioventricular delay and pacing chamber, biventricular or LV only, or a fixed atrioventricular delay of 120 ms with biventricular pacing. Paired echocardiograms performed at baseline and 6 months were evaluated. The primary end point was echocardiographic cardiac resynchronization therapy response, defined dichotomously as a >15% reduction in LV end-systolic volume. RESULTS: A total of 310 patients (n=120 women) were randomized and had completed 6 months of follow-up. The echocardiographic cardiac resynchronization therapy response rate did not statistically differ between the groups (SmartDelay, 74.8%; fixed, 67.7%; P=0.17). Analyses of prespecified secondary end points demonstrated significant improvements in the absolute (median: SmartDelay, -41.0 mL; fixed, -33.0 mL; P=0.01) and relative change in LV end-systolic volume (SmartDelay, -38.3%; fixed, -27.8%; P=0.03) for patients with SmartDelay optimization. Similar results were observed for the relative improvement in LV ejection fraction (SmartDelay, 46.7%; fixed, 32.1%; P=0.050); absolute improvement in LV ejection fraction trended to be higher with SmartDelay (P=0.06). CONCLUSIONS: Analysis of reverse remodeling parameters demonstrated that AVO via SmartDelay, relative to the nonoptimized fixed atrioventricular delay comparator group, improved absolute and relative changes in LV function in patients with longer right ventricular-LV duration. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03089281.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Feminino , Terapia de Ressincronização Cardíaca/métodos , Estudos Prospectivos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular/fisiologia
8.
JAMA Cardiol ; 7(5): 540-548, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35319725

RESUMO

Importance: Despite bearing a disproportionate burden of heart failure (HF), Black and Hispanic individuals have been poorly represented in HF clinical trials. Underrepresentation in clinical trials limits the generalizability of the findings to these populations and may even introduce uncertainties and hesitancy when translating trial data to the care of people from underrepresented groups. The Heart Failure Collaboratory, a consortium of stakeholders convened to enhance HF therapeutic development, has been dedicated to improving recruitment strategies for patients from diverse and historically underrepresented groups. Observations: Despite federal policies from the US Food and Drug Administration and National Institutes of Health aimed at improving trial representation, gaps in trial enrollment proportionate to the racial and ethnic composition of the HF population have persisted. Increasing trial globalization with limited US enrollment is a major driver of these patterns. Additional barriers to representative enrollment include inequities in care access, logistical issues in participation, restrictive enrollment criteria, and English language requirements. Conclusions and Relevance: Strategies for improving diverse trial enrollment include methodical study design and site selection, diversification of research leadership and staff, broadening of eligibility criteria, community and patient engagement, and broad stakeholder commitment. In contemporary HF trials, diverse trial enrollment is not only feasible but can be efficiently achieved to improve the generalizability and translation of trial knowledge to clinical practice.


Assuntos
Etnicidade , Insuficiência Cardíaca , População Negra , Insuficiência Cardíaca/terapia , Humanos , Seleção de Pacientes , Grupos Raciais
9.
Circ Heart Fail ; 15(1): e008797, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34937393

RESUMO

BACKGROUND: Regulatory and clinical decisions involving health technologies require judgements about relative importance of their expected benefits and risks. We sought to quantify heart-failure patients' acceptance of therapeutic risks in exchange for improved effectiveness with implantable devices. METHODS: Individuals with heart failure recruited from a national web panel or academic medical center completed a web-based discrete-choice experiment survey in which they were randomized to one of 40 blocks of 8 experimentally controlled choice questions comprised of 2 device scenarios and a no-device scenario. Device scenarios offered an additional year of physical functioning equivalent to New York Heart Association class III or a year with improved (ie, class II) symptoms, or both, with 30-day mortality risks ranging from 0% to 15%, in-hospital complication risks ranging from 0% to 40%, and a remote adjustment device feature. Logit-based regression models fit participants' choices as a function of health outcomes, risks and remote adjustment. RESULTS: Latent-class analysis of 613 participants (mean age, 65; 49% female) revealed that two-thirds were best represented by a pro-device, more risk-tolerant class, accepting up to 9% (95% CI, 7%-11%) absolute risk of device-associated mortality for a one-year gain in improved functioning (New York Heart Association class II). Approximately 20% were best represented by a less risk-tolerant class, accepting a maximum device-associated mortality risk of 3% (95% CI, 1%-4%) for the same benefit. The remaining class had strong antidevice preferences, thus maximum-acceptable risk was not calculated. CONCLUSIONS: Quantitative evidence on benefit-risk tradeoffs for implantable heart-failure device profiles may facilitate incorporating patients' views during product development, regulatory decision-making, and clinical practice.


Assuntos
Comportamento de Escolha/fisiologia , Insuficiência Cardíaca/fisiopatologia , Preferência do Paciente/estatística & dados numéricos , Adulto , Idoso , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Risco , Medição de Risco , Inquéritos e Questionários/estatística & dados numéricos
10.
Circulation ; 143(1): 7-17, 2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33073614

RESUMO

BACKGROUND: The subcutaneous (S) implantable cardioverter-defibrillator (ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, had less left ventricular dysfunction, and received more inappropriate shocks (IAS) than in typical transvenous ICD trials. The UNTOUCHED trial (Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction) was designed to evaluate the IAS rate in a more typical, contemporary ICD patient population implanted with the S-ICD using standardized programming and enhanced discrimination algorithms. METHODS: Primary prevention patients with left ventricular ejection fraction ≤35% and no pacing indications were included. Generation 2 or 3 S-ICD devices were implanted and programmed with rate-based therapy delivery for rates ≥250 beats per minute and morphology discrimination for rates ≥200 and <250 beats per minute. Patients were followed for 18 months. The primary end point was the IAS-free rate compared with a 91.6% performance goal, derived from the results for the ICD-only patients in the MADIT-RIT study (Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy). Kaplan-Meier analyses were performed to evaluate event-free rates for IAS, all-cause shock, and complications. Multivariable proportional hazard analysis was performed to determine predictors of end points. RESULTS: S-ICD implant was attempted in 1116 patients, and 1111 patients were included in postimplant follow-up analysis. The cohort had a mean age of 55.8±12.4 years, 25.6% were women, 23.4% were Black, 53.5% had ischemic heart disease, 87.7% had symptomatic heart failure, and the mean left ventricular ejection fraction was 26.4±5.8%. Eighteen-month freedom from IAS was 95.9% (lower confidence limit, 94.8%). Predictors of reduced incidence of IAS were implanting the most recent generation of device, using the 3-incision technique, no history of atrial fibrillation, and ischemic cause. The 18-month all-cause shock-free rate was 90.6% (lower confidence limit, 89.0%), meeting the prespecified performance goal of 85.8%. Conversion success rate for appropriate, discrete episodes was 98.4%. Complication-free rate at 18 months was 92.7%. CONCLUSIONS: This study demonstrates high efficacy and safety with contemporary S-ICD devices and programming despite the relatively high incidence of comorbidities in comparison with earlier S-ICD trials. The inappropriate shock rate (3.1% at 1 year) is the lowest reported for the S-ICD and lower than many transvenous ICD studies using contemporary programming to reduce IAS. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02433379.


Assuntos
Arritmias Cardíacas/prevenção & controle , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/normas , Prevenção Primária/métodos , Volume Sistólico/fisiologia , Adulto , Idoso , Arritmias Cardíacas/fisiopatologia , Estudos de Coortes , Morte Súbita Cardíaca/epidemiologia , Desfibriladores/normas , Desfibriladores/tendências , Desfibriladores Implantáveis/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
11.
Europace ; 22(2): 225-231, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31665276

RESUMO

AIMS: Clinical practice guidelines do not recommend discontinuation of long-term oral anticoagulation in patients with a high stroke risk after catheter ablation for atrial fibrillation (AF). Left atrial appendage closure (LAAC) with Watchman has emerged as an alternative to long-term anticoagulation for patients accepting of the procedural risks. We report on the long-term outcomes of combining catheter ablation procedures for AF and LAAC from multicentre registries. METHODS AND RESULTS: Data were pooled from two prospective, real-world Watchman LAAC registries running in parallel in Europe/Middle-East/Russia (EWOLUTION) and Asia/Australia (WASP) between 2013 and 2015. Of the 1140 patients, 142 subjects at 11 centres underwent a concomitant AF ablation and LAAC procedure. The mean CHA2DS2-VASc score was 3.4 ± 1.4 and HAS-BLED score 1.5 ± 0.9. Successful LAAC was achieved in 99.3% of patients. The 30-day device and/or procedure-related serious adverse event rate was 2.1%. After a mean follow-up time of 726 ± 91 days, 92% of patients remained off oral anticoagulation. The rates of the composite endpoint of ischaemic stroke/transient ischaemic attack/systemic thromboembolism were 1.09 per 100 patient-years (100-PY); and for non-procedural major bleeding were 1.09 per 100-PY. These represent relative reductions of 84% and 70% vs. expected rates per risk scores. CONCLUSION: The long-term outcomes from these international, multicentre registries show efficacy for all-cause stroke prevention and a significant reduction in late bleeding events in a population of high stroke risk post-ablation patients who have been withdrawn from oral anticoagulation.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Isquemia Encefálica , Ablação por Cateter , Acidente Vascular Cerebral , Anticoagulantes , Ásia/epidemiologia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Austrália , Europa (Continente) , Humanos , Oriente Médio , Estudos Prospectivos , Sistema de Registros , Federação Russa , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
13.
Heart Rhythm ; 16(11): 1636-1644, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31082539

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has shown favorable outcomes in large registries with broad inclusion criteria. The cohorts reported had less heart disease and fewer comorbidities than standard ICD populations. OBJECTIVE: The purpose of this study is to characterize acute performance for primary prevention patients with a left ventricular ejection fraction (LVEF) ≤35% (primary prevention ≤35%). METHODS: Primary prevention ≤35% patients with no prior documented sustained ventricular tachycardia (VT), pacing indication, end-stage heart failure, or advanced renal failure were prospectively enrolled. Analyses included descriptive statistics, Kaplan-Meier time to event, and multivariable linear and logistic regression. RESULTS: In 1112 of 1116 patients, an S-ICD was successfully implanted (99.6%). Predictors for longer procedure time included 3-incision technique, higher body mass index (BMI), performing defibrillation testing (DFT), imaging, younger age, black race, and European vs North American centers. Patients undergoing DFT (82%) were successfully converted (99.2%; 93.5% converting at ≤65 J). Higher BMI was predictive of failing DFT at ≤65 J. The rate of 30-day freedom from complications was 95.8%. Most complications involved postoperative healing (45%) or interventions after DFT or impedance check (19%). CONCLUSION: The procedural outcome data of UNTOUCHED reinforce that S-ICD therapy has low perioperative complication rates and high conversion efficacy of induced ventricular fibrillation, even in a higher-risk cohort with low LVEF and more comorbidities than previous S-ICD studies. Higher BMI warrants more careful attention to implant technique.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Prevenção Primária , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias , Estudos Prospectivos , Volume Sistólico
14.
Int J Cardiol Heart Vasc ; 23: 100358, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31008181

RESUMO

BACKGROUND: Left atrial appendage closure is a non-pharmacological alternative for stroke prevention in high-risk non-valvular atrial fibrillation patients, but has not been widely studied in Asian patients. The prospective WASP registry assessed real-world outcomes for patients undergoing WATCHMAN implant in the Asia-Pacific region. METHODS: Data were collected from consecutive patients across 9 centres. Major endpoints included procedural success, safety and long-term outcomes including occurrence of bleeding, stroke/transient ischaemic attack/systemic embolism and all-cause mortality. RESULTS: Subjects (n = 201) had a mean age of 70.8 ±â€¯9.4 years, high stroke risk (CHA2DS2-VASc: 3.9 ±â€¯1.7), elevated bleeding risk (HAS-BLED: 2.1 ±â€¯1.2) with 53% patients from Asian countries. Successful implantation occurred in 98.5% of patients; 7-day device/procedure-related SAE rate was 3.0%. After 2 years of follow-up, the rates of ischaemic stroke/TIA/SE and major bleeding were 1.9 and 2.2 per 100-PY, respectively, representing relative reductions of 77% and 49% versus expected rates per risk scores. The relative risk reductions versus expected rates were more pronounced in Asians vs. Non-Asians (89% vs 62%; 77% vs 14%). Other significant findings included larger mean LAA ostium diameter for Asians vs. Non-Asians (23.4 ±â€¯4.1 mm vs. 21.2 ±â€¯3.2 mm, p < 0.001) and hence requirement for larger median device size (27 mm for Asians, 24 mm for non-Asians [p < 0.0001]). CONCLUSION: Real-world experience of left atrial appendage closure with WATCHMAN has demonstrated low peri-procedural risk, and long-term efficacy for stroke and bleeding prevention in a primarily Asian cohort.

15.
Heart Rhythm ; 16(5): 743-753, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30476543

RESUMO

BACKGROUND: Predicting a favorable cardiac resynchronization therapy (CRT) response holds great clinical importance. OBJECTIVE: The purpose of this study was to examine proteins from broad biological pathways and develop a prediction tool for response to CRT. METHODS: Plasma was collected from patients before CRT (SMART-AV [SmartDelay Determined AV Optimization: A Comparison to Other AV Delay Methods Used in Cardiac Resynchronization Therapy] trial). A CRT response was prespecified as a ≥15-mL reduction in left ventricular end-systolic volume at 6 months, which resulted in a binary CRT response (responders 52%, nonresponders 48%; n = 758). RESULTS: Candidate proteins (n = 74) were evaluated from the inflammatory, signaling, and structural domains, which yielded 12 candidate biomarkers, but only a subset of these demonstrated predictive value for CRT response: soluble suppressor of tumorgenicity-2, soluble tumor necrosis factor receptor-II, matrix metalloproteinase-2, and C-reactive protein. These biomarkers were used in a composite categorical scoring algorithm (Biomarker CRT Score), which identified patients with a high/low probability of a response to CRT (P <.001) when adjusted for a number of clinical covariates. For example, a Biomarker CRT Score of 0 yielded 5 times higher odds of a response to CRT compared to a Biomarker CRT Score of 4 (P <.001). The Biomarker CRT Score demonstrated additive predictive value when considered against a composite of clinical variables. CONCLUSION: These unique findings demonstrate that developing a biomarker panel for predicting individual response to CRT is feasible and holds potential for point-of-care testing and integration into evaluation algorithms for patients presenting for CRT.


Assuntos
Proteína C-Reativa/análise , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Metaloproteinase 2 da Matriz/análise , Receptores Tipo II do Fator de Necrose Tumoral/análise , Idoso , Biomarcadores/sangue , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde/métodos , Período Pós-Operatório , Valor Preditivo dos Testes , Prognóstico
16.
Circ Arrhythm Electrophysiol ; 11(8): e006055, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30354310

RESUMO

BACKGROUND: Routine atrioventricular optimization (AVO) has not been shown to improve outcomes with cardiac resynchronization therapy (CRT). However, more recently subgroup analyses of multicenter CRT trials have identified electrocardiographic or lead positions associated with benefit from AVO. Therefore, the purpose of this analysis was to evaluate whether interventricular electrical delay modifies the impact of AVO on reverse remodeling with CRT. METHODS: This substudy of the SMART-AV trial (SMARTDELAY Determined AV Optimization) included 275 subjects who were randomized to either an electrogram-based AVO (SmartDelay) or nominal atrioventricular delay (120 ms). Interventricular delay was defined as the time between the peaks of the right ventricular (RV) and left ventricular (LV) electrograms (RV-LV duration). CRT response was defined prospectively as a >15% reduction in LV end-systolic volume from implant to 6 months. RESULTS: The cohort was 68% men, with a mean age of 65±11 years and LV ejection fraction of 28±8%. Longer RV-LV durations were significantly associated with CRT response ( P<0.01) for the entire cohort. Moreover, the benefit of AVO increased as RV-LV duration prolonged. At the longest quartile, there was a 4.26× greater odds of a remodeling response compared with nominal atrioventricular delays ( P=0.010). CONCLUSIONS: Baseline interventricular delay predicted CRT response. At long RV-LV durations, AVO can increase the likelihood of reverse remodeling with CRT. AVO and LV lead location optimized to maximize interventricular delay may work synergistically to increase CRT response. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT00874445.


Assuntos
Nó Atrioventricular/fisiopatologia , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Frequência Cardíaca , Função Ventricular Esquerda , Função Ventricular Direita , Remodelação Ventricular , Potenciais de Ação , Idoso , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento
17.
J Cardiovasc Electrophysiol ; 29(7): 973-978, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29722469

RESUMO

INTRODUCTION: Pericardial effusion/tamponade (PE/PT) is a rare but serious complication following left atrial appendage closure (LAAC). It may be speculated that LAA contraction during sinus rhythm (SR) exerts mechanical force on the device that eventually leads to PE. We sought to determine the incidence and predictors of PE following LAAC using Watchman with special emphasis on the underlying heart rhythm during implant. METHODS AND RESULTS: From 47 centers in 13 European countries 1,020 patients underwent LAAC and data on baseline rhythm were available from 1,010 patients (mean age 73 ± 9 years, 60% male, median CHA2DS2-VASc = 4). Data were collected via electronic case report forms. A Cox proportional hazard model was calculated adjusting for multiple variables: age, gender, number of recaptures, and device oversizing. During implant, 41% and 59% of patients were in SR and atrial fibrillation (AF), respectively. PE/PT rate was significantly lower in patients implanted during AF at day 30 postimplant (n = 1; 0.2% vs. n = 6; 1.5%; P = 0.02). No PE requiring intervention occurred in the AF group compared to 5 events (1.2%) in the SR group (P = 0.01). While univariate analysis identified SR and gender as predictors for PE/tamponade, multivariate analysis only showed a statistical trend for both variables. CONCLUSION: The overall incidence of PE/PT was very low after LAAC using Watchman. Although SR was not identified as an independent predictor of PE/PT, all events requiring intervention occurred in patients with SR. It may be advisable to perform an extended echocardiographic follow-up in that patient population.


Assuntos
Apêndice Atrial/cirurgia , Procedimentos Endovasculares/efeitos adversos , Frequência Cardíaca/fisiologia , Derrame Pericárdico/epidemiologia , Derrame Pericárdico/fisiopatologia , Dispositivos de Oclusão Vascular/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Procedimentos Endovasculares/tendências , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Derrame Pericárdico/diagnóstico por imagem , Sistema de Registros , Dispositivos de Oclusão Vascular/tendências
18.
EuroIntervention ; 13(17): 2003-2011, 2018 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-29313819

RESUMO

AIMS: The study aimed to confirm the efficacy and safety of WATCHMAN LAA closure in atrial fibrillation patients unsuitable for oral anticoagulation. METHODS AND RESULTS: The EWOLUTION registry prospectively collects all clinical data on 1,005 European patients implanted with a WATCHMAN device. Following the procedure, 605 patients (60.2%) received dual antiplatelet therapy according to the local standard; DAPT was discontinued in 85% of patients within one year. CHA2DS2-VASc and HAS-BLED scores were 4.61.6 and 2.41.2, respectively. The periprocedural SAE rate was 3.3% (2.0% major adverse cardiac events), mostly resolving without sequelae. Device embolisation or pericardial effusion occurred in one (0.2%) and two (0.3%) patients, respectively. TEE (median 62 days post implant, IQR: 47-97) confirmed effective sealing (no leak >5 mm) in 99.2% of patients. Device thrombus was present in 22 patients (4.0%), one patient developed a stroke. One-year mortality in the DAPT group was 9.6% (N=58) reflecting the advanced age and comorbidities in this population. The ischaemic stroke rate at one year was 1.4% (expected based on CHA2DS2-VASc: 7.5%), none fatal. The major bleeding rate was 2.5%, or 2.1% excluding periprocedural events (expected rate on VKA based on HAS-BLED: 5.1%). CONCLUSIONS: LAA closure with the WATCHMAN device followed by DAPT therapy in a high-risk patient population is safe. At one year, the intervention is associated with a substantial risk reduction regarding ischaemic stroke and major bleeding compared to the expected rate based on CHA2DS2-VASc and HAS-BLED scores.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial , Hemorragia , Inibidores da Agregação Plaquetária , Complicações Pós-Operatórias , Implantação de Prótese , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Quimioterapia Combinada/métodos , Europa (Continente) , Feminino , Átrios do Coração , Hemorragia/induzido quimicamente , Hemorragia/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Implantação de Prótese/estatística & dados numéricos , Sistema de Registros , Risco Ajustado/métodos , Dispositivo para Oclusão Septal/efeitos adversos , Dispositivo para Oclusão Septal/estatística & dados numéricos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
19.
Europace ; 20(6): 949-955, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29106523

RESUMO

Aims: Long-term results from catheter ablation therapy for atrial fibrillation (AF) remain uncertain and clinical practice guidelines recommend continuation of long-term oral anticoagulation in patients with a high stroke risk. Left atrial appendage closure (LAAC) with Watchman has emerged as an alternative to long-term anticoagulation for patients accepting of the procedural risks. We report on the initial results of combining catheter ablation procedures for AF and LAAC in a multicentre registry. Methods and results: Data were pooled from two prospective, real-world Watchman LAAC registries running in parallel in Europe/Middle-East/Russia (EWOLUTION) and Asia/Australia (WASP) between 2013 and 2015. Of the 1140 patients, 139 subjects at 10 centres underwent a concomitant AF ablation and LAAC procedure. The mean CHA2DS2-VASc score was 3.4 ± 1.4 and HAS-BLED score 1.5 ± 0.9. Successful Watchman implantation was achieved in 100% of patients. The overall 30-day serious adverse event (SAE) rate was 8.7%, with the device and/or procedure-related SAE rate of 1.4%. One pericardial effusion required percutaneous drainage, but there were no strokes, device embolization, or deaths at 30 days. The 30-day bleeding SAE rate was 2.9% with 55% of patients prescribed NOAC and 38% taking warfarin post-procedure. Conclusion: The outcomes from these international, multicentre registries support the feasibility and safety of performing combined procedures of ablation and Watchman LAAC for patients with non-valvular AF and high stroke risk. Further data are needed on long-term outcomes for the hybrid technique on all-cause stroke and mortality.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Derrame Pericárdico , Complicações Pós-Operatórias/diagnóstico , Hemorragia Pós-Operatória/diagnóstico , Implantação de Prótese , Dispositivo para Oclusão Septal , Idoso , Ásia/epidemiologia , Fibrilação Atrial/epidemiologia , Austrália/epidemiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Europa (Continente)/epidemiologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Oriente Médio/epidemiologia , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/etiologia , Estudos Prospectivos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Sistema de Registros/estatística & dados numéricos , Federação Russa/epidemiologia
20.
Int J Cardiol ; 244: 229-234, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28663046

RESUMO

BACKGROUND: The NECTAR-HF study evaluated safety and feasibility of vagal nerve stimulation (VNS) for the treatment of heart failure patients. The first six-month randomized phase of the study did not show improvement in left ventricular remodelling in response to VNS. This study reports the 18-month results and provides novel findings aiming to understand the lack of efficacy of VNS, including a new technique assessing the effects of VNS. METHODS: Ninety-six patients were randomized 2:1 to active or inactive VNS for 6months, thereafter VNS was activated for all patients. The primary safety endpoint was 18-month all-cause mortality. RESULTS: Ninety-one patients continued in the long-term evaluation with active VNS. The on-therapy survival estimate at 18months was 95% with a 95% one-sided lower confidence limit of 91%, (better than the predefined criterion). Left ventricular systolic volume decreased in the crossover group (VNS OFF→ON; 144±37 to 139±40, p<0.05) after VNS activation; LVESD (5.02±0.77 to 4.96±0.82, p>0.05) and LVEF (33.2±4.9 to 33.3±6.5, p>0.05) did not change. A new technique to detect subtle heart rate changes during Holter recordings, i.e. "heat maps", revealed that VNS evoked heart rate response in only 13/106 studies (12%) at 6 and 12months with active VNS. CONCLUSIONS: Although a favourable long-term safety profile was found, improvements in the efficacy endpoints were not seen with VNS. A new technique for detecting acute heart rate responses to VNS suggests that the recruitment of nerve fibres responsible for heart rate changes were substantially lower in NECTAR-HF than in pre-clinical models.


Assuntos
Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Estimulação do Nervo Vago/tendências , Idoso , Eletrocardiografia Ambulatorial/mortalidade , Eletrocardiografia Ambulatorial/tendências , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Estimulação do Nervo Vago/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA