1.
Crit Care ; 25(1): 192, 2021 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-34082795

RESUMO

BACKGROUND: In acute respiratory distress syndrome (ARDS), non-ventilated perfused regions coexist with non-perfused ventilated regions within lungs. The number of unmatched regions might reflect ARDS severity and affect the risk of ventilation-induced lung injury. Despite pathophysiological relevance, unmatched ventilation and perfusion are not routinely assessed at the bedside. The aims of this study were to quantify unmatched ventilation and perfusion at the bedside by electrical impedance tomography (EIT) investigating their association with mortality in patients with ARDS and to explore the effects of positive end-expiratory pressure (PEEP) on unmatched ventilation and perfusion in subgroups of patients with different ARDS severity based on PaO2/FiO2 and compliance. METHODS: Prospective observational study in 50 patients with mild (36%), moderate (46%), and severe (18%) ARDS under clinical ventilation settings. EIT was applied to measure the regional distribution of ventilation and perfusion using central venous bolus of saline 5% during end-inspiratory pause. We defined unmatched units as the percentage of only ventilated units plus the percentage of only perfused units. RESULTS: Percentage of unmatched units was significantly higher in non-survivors compared to survivors (32[27-47]% vs. 21[17-27]%, p < 0.001). Percentage of unmatched units was an independent predictor of mortality (OR 1.22, 95% CI 1.07-1.39, p = 0.004) with an area under the ROC curve of 0.88 (95% CI 0.79-0.97, p < 0.001). The percentage of ventilation to the ventral region of the lung was higher than the percentage of ventilation to the dorsal region (32 [27-38]% vs. 18 [13-21]%, p < 0.001), while the opposite was true for perfusion (28 [22-38]% vs. 36 [32-44]%, p < 0.001). Higher percentage of only perfused units was correlated with lower dorsal ventilation (r = - 0.486, p < 0.001) and with lower PaO2/FiO2 ratio (r = - 0.293, p = 0.039). CONCLUSIONS: EIT allows bedside assessment of unmatched ventilation and perfusion in mechanically ventilated patients with ARDS. Measurement of unmatched units could identify patients at higher risk of death and could guide personalized treatment.


Assuntos
Impedância Elétrica/uso terapêutico , Perfusão/normas , Prognóstico , Respiração Artificial/normas , Síndrome do Desconforto Respiratório/complicações , Adulto , Idoso , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Perfusão/métodos , Perfusão/estatística & dados numéricos , Estudos Prospectivos , Respiração Artificial/métodos , Respiração Artificial/estatística & dados numéricos , Síndrome do Desconforto Respiratório/epidemiologia , Síndrome do Desconforto Respiratório/mortalidade , Escore Fisiológico Agudo Simplificado
2.
Biomed Tech (Berl) ; 66(3): 231-245, 2021 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-33565285

RESUMO

Arterial blood pressure is one of the most often measured vital parameters in clinical practice. State-of-the-art noninvasive ABP measurement technologies have noticeable limitations and are mainly based on uncomfortable techniques of complete or partial arterial occlusion by cuffs. Most commonplace devices provide only intermittent measurements, and continuous systems are bulky and difficult to apply correctly for nonprofessionals. Continuous cuffless ABP measurements are still an unmet clinical need and a topic of ongoing research, with only few commercially available devices. This paper discusses surrogate-based noninvasive blood pressure measurement techniques. It covers measurement methods of continuously and noninvasively inferring BP from surrogate signals without applying external pressures, except for reference or initialization purposes. The BP is estimated by processing signal features, so called surrogates, which are modulated by variations of BP. Discussed techniques include well-known approaches such as pulse transit time and pulse arrival time techniques, pulse wave analysis or combinations thereof. Despite a long research history, these methods have not found widespread use in clinical and ambulatory practice, in part due to technical limitations and the lack of a standardized regulatory framework. This work summarizes findings from an invited workshop of experts in the fields covering clinical expertise, engineering aspects, commercialization and standardization issues. The goal is to provide an application driven outlook, starting with clinical needs, and extending to technical actuality. It provides an outline of recommended research directions and includes a detailed overview of clinical use case scenarios for these technologies, opportunities, and limitations.


Assuntos
Pressão Sanguínea/fisiologia , Análise de Onda de Pulso/instrumentação , Determinação da Pressão Arterial/métodos , Humanos , Processamento de Sinais Assistido por Computador
3.
IEEE Trans Med Imaging ; 40(1): 251-261, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32956046

RESUMO

Electrical impedance tomography is clinically used to trace ventilation related changes in electrical conductivity of lung tissue. Estimating regional pulmonary perfusion using electrical impedance tomography is still a matter of research. To support clinical decision making, reliable bedside information of pulmonary perfusion is needed. We introduce a method to robustly detect pulmonary perfusion based on indicator-enhanced electrical impedance tomography and validate it by dynamic multidetector computed tomography in two experimental models of acute respiratory distress syndrome. The acute injury was induced in a sublobar segment of the right lung by saline lavage or endotoxin instillation in eight anesthetized mechanically ventilated pigs. For electrical impedance tomography measurements, a conductive bolus (10% saline solution) was injected into the right ventricle during breath hold. Electrical impedance tomography perfusion images were reconstructed by linear and normalized Gauss-Newton reconstruction on a finite element mesh with subsequent element-wise signal and feature analysis. An iodinated contrast agent was used to compute pulmonary blood flow via dynamic multidetector computed tomography. Spatial perfusion was estimated based on first-pass indicator dilution for both electrical impedance and multidetector computed tomography and compared by Pearson correlation and Bland-Altman analysis. Strong correlation was found in dorsoventral (r = 0.92) and in right-to-left directions (r = 0.85) with good limits of agreement of 8.74% in eight lung segments. With a robust electrical impedance tomography perfusion estimation method, we found strong agreement between multidetector computed and electrical impedance tomography perfusion in healthy and regionally injured lungs and demonstrated feasibility of electrical impedance tomography perfusion imaging.


Assuntos
Síndrome do Desconforto Respiratório , Animais , Impedância Elétrica , Pulmão/diagnóstico por imagem , Perfusão , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Suínos , Tomografia , Tomografia Computadorizada por Raios X
4.
IEEE Trans Med Imaging ; 34(7): 1460-1473, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25667349

RESUMO

Knowledge of left atrial (LA) anatomy is important for atrial fibrillation ablation guidance, fibrosis quantification and biophysical modelling. Segmentation of the LA from Magnetic Resonance Imaging (MRI) and Computed Tomography (CT) images is a complex problem. This manuscript presents a benchmark to evaluate algorithms that address LA segmentation. The datasets, ground truth and evaluation code have been made publicly available through the http://www.cardiacatlas.org website. This manuscript also reports the results of the Left Atrial Segmentation Challenge (LASC) carried out at the STACOM'13 workshop, in conjunction with MICCAI'13. Thirty CT and 30 MRI datasets were provided to participants for segmentation. Each participant segmented the LA including a short part of the LA appendage trunk and proximal sections of the pulmonary veins (PVs). We present results for nine algorithms for CT and eight algorithms for MRI. Results showed that methodologies combining statistical models with region growing approaches were the most appropriate to handle the proposed task. The ground truth and automatic segmentations were standardised to reduce the influence of inconsistently defined regions (e.g., mitral plane, PVs end points, LA appendage). This standardisation framework, which is a contribution of this work, can be used to label and further analyse anatomical regions of the LA. By performing the standardisation directly on the left atrial surface, we can process multiple input data, including meshes exported from different electroanatomical mapping systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA