Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Surg Endosc ; 37(11): 8552-8561, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37794124

RESUMO

BACKGROUND: During minimal access surgery, surgical smoke is produced which can potentially be inhaled by the surgical team, leading to several health risks. This smoke can escape from the abdominal cavity into the operating room due to trocar leakage. The trocars and insufflator that are used during surgery influence gas leakage. Therefore, this study compares particle escape from a valveless (Conmed AirSeal iFS), and a conventional (Karl Storz Endoflator) system. MATERIALS AND METHODS: Using an in vitro model, a conventional and a valveless trocar system were compared. A protocol that simulated various surgical phases was defined to assess the surgical conditions and particle leakage. Insufflation pressures and instrument diameters were varied as these are known to affect gas leakage. RESULTS: The conventional trocar leaked during two distinct phases. Removal of the obturator caused a sudden release of particles. During instrument insertion, an average of 211 (IQR 111) particles per second escaped when using the 5 mm diameter instrument. With the 10 mm instrument, 50 (IQR 13) particles per second were measured. With the conventional trocar, a higher abdominal pressure increased particle leakage. The valveless trocar demonstrated a continuously high particle release during all phases. After the obturator was removed, particle escape increased sharply. Particle escape decreased to 1276 (IQR 580) particles per second for the 5 mm instrument insertion, and 1084 (IQR 630) particles per second for 10 mm instrument insertion. With the valveless trocar system, a higher insufflation pressure lowered particle escape. CONCLUSIONS: This study shows that a valveless trocar system releases more particles into the operating room environment than a conventional trocar. During instrument insertion, the leakage through the valveless system is 6 to 20 times higher than the conventional system. With a valveless trocar, leakage decreases with increasing pressure. With both trocar types leakage depends on instrument diameter.


Assuntos
Cavidade Abdominal , Insuflação , Laparoscopia , Humanos , Laparoscopia/métodos , Fumaça/efeitos adversos , Instrumentos Cirúrgicos , Insuflação/métodos
2.
PLoS One ; 18(5): e0285108, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37146021

RESUMO

In laparoscopic surgery the abdominal cavity is insufflated with pressurized carbon dioxide gas to create workspace. This pressure is exerted through the diaphragm onto the lungs, competing with ventilation and hampering it. In clinical practice the difficulty of optimizing this balance can lead to the application of harmfully high pressures. This study set out to create a research platform for the investigation of the complex interaction between insufflation and ventilation in an animal model. The research platform was constructed to incorporate insufflation, ventilation and relevant hemodynamic monitoring devices, controlling insufflation and ventilation from a central computer. The core of the applied methodology is the fixation of physiological parameters by applying closed-loop control of specific ventilation parameters. For accurate volumetric measurements the research platform can be used in a CT scanner. An algorithm was designed to keep blood carbon dioxide and oxygen values stable, minimizing the effect of fluctuations on vascular tone and hemodynamics. This design allowed stepwise adjustment of insufflation pressure to measure the effects on ventilation and circulation. A pilot experiment in a porcine model demonstrated adequate platform performance. The developed research platform and protocol automation have the potential to increase translatability and repeatability of animal experiments on the biomechanical interactions between insufflation and ventilation.


Assuntos
Insuflação , Laparoscopia , Animais , Suínos , Insuflação/métodos , Dióxido de Carbono , Pressão , Laparoscopia/métodos , Respiração , Hemodinâmica , Pulmão
3.
Prenat Diagn ; 43(3): 355-358, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36627260

RESUMO

OBJECTIVE: To develop a realistic simulation model for laparotomy-assisted fetoscopic spina bifida aperta (SBa) surgery, to be used for training purposes and preoperative planning. METHODS: The predefined general requirement was a realistic model of an exteriorized uterus, allowing all neurosurgical steps of the intervention. The uterus was modelled using ultrasound and MRI images of a 25 weeks' gravid uterus, consisting of flexible polyurethane foam coated with pigmented silicone. The fetal model, contained an opening on the dorsal side for a customizable spinal insert with all the aspects of a SBa, including a cele, placode, and myofascial and skin layer. The model was assessed in a series of validation experiments. RESULTS: Production costs are low, uterus and fetus are reusable. Placental localization and the level and size of the spinal defect are adjustable, enabling case-specific adaptations. All aspects of the simulator were scored close to realistic or higher for both appearance and functional capacities. CONCLUSIONS: This innovative model provides an excellent training opportunity for centers that are starting a fetoscopic SBa repair program. It is the first simulation model with adjustable spinal defect and placental localisation. Further objective validation is required, but the potential for using this model in preoperative planning is promising.


Assuntos
Meningomielocele , Espinha Bífida Cística , Gravidez , Feminino , Humanos , Meningomielocele/diagnóstico por imagem , Meningomielocele/cirurgia , Placenta/diagnóstico por imagem , Placenta/cirurgia , Espinha Bífida Cística/cirurgia , Fetoscopia/métodos , Feto/diagnóstico por imagem , Feto/cirurgia
4.
Surg Endosc ; 36(9): 7066-7074, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35864355

RESUMO

BACKGROUND: Abdominal compliance describes the ease of expansion of the abdominal cavity. Several studies highlighted the importance of monitoring abdominal compliance (Cab) during the creation of laparoscopic workspace to individualize the insufflation pressure. The lack of validated clinical monitoring tools for abdominal compliance prevents accurate tailoring of insufflation pressure. Oscillometry, also known as the forced oscillation technique (FOT), is currently used to measure respiratory mechanics and has the potential to be adapted for monitoring abdominal compliance. This study aimed to define, develop and evaluate a novel approach which can monitor abdominal compliance during laparoscopy using endoscopic oscillometry. MATERIALS AND METHODS: Endoscopic oscillometry was evaluated in a porcine model for laparoscopy. A custom-built insufflator was developed for applying an oscillatory pressure signal superimposed onto a mean intra-abdominal pressure. This insufflator was used to measure the abdominal compliance at insufflation pressures ranging from 5 to 20 hPa (3.75 to 15 mmHg). The measurements were compared to the static abdominal compliance, which was measured simultaneously with computed tomography imaging. RESULTS: Endoscopic oscillometry recordings and CT images were obtained in 10 subjects, resulting in 76 measurement pairs for analysis. The measured dynamic Cab ranged between 0.0216 and 0.261 L/hPa while the static Cab based on the CT imaging ranged between 0.0318 and 0.364 L/hPa. The correlation showed a polynomial relation and the adjusted R-squared was 97.1%. CONCLUSIONS: Endoscopic oscillometry can be used to monitor changes in abdominal compliance during laparoscopic surgery, which was demonstrated in this study with a comparison with CT imaging in a porcine laparoscopy model. Use of this technology to personalize the insufflation pressure could reduce the risk of applying excessive pressure and limit the drawbacks of insufflation.


Assuntos
Cavidade Abdominal , Insuflação , Laparoscopia , Cavidade Abdominal/cirurgia , Animais , Dióxido de Carbono , Humanos , Insuflação/métodos , Laparoscopia/métodos , Pneumoperitônio Artificial/métodos , Pressão , Suínos
5.
Surg Endosc ; 36(6): 4542-4551, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34731302

RESUMO

BACKGROUND: During laparoscopy, the abdominal cavity is insufflated with carbon dioxide (CO2) that could become contaminated with viruses and surgical smoke. Medical staff is potentially exposed when this gas leaks into the operating room through the instruments and past trocar valves. No detailed studies currently exist that have quantified these leakage pathways. Therefore, the goal of this study was to quantify the gas leakages through trocars and instruments, during minimally invasive procedures. METHODS: A model of the surgical environment was created, consisting of a rigid container with an interface for airtight clamping of laparoscopic equipment such as trocars and surgical instruments. The model was insufflated to 15 mm Hg using a pressure generator and a pneumotachograph measured the equipment gas leak. A protocol of several use cases was designed to simulate the motions and forces the surgeon exerts on the trocar during surgery. RESULTS: Twenty-three individual trocars and twenty-six laparoscopic instruments were measured for leakage under the different conditions of the protocol. Trocar leakages varied between 0 L/min and more than 30 L/min, the instruments revealed a range of leakages between 0 L/min and 5.5 L/min. The results showed that leakage performance varied widely between trocars and instruments and that the performance and location of the valves influenced trocar leakage. CONCLUSIONS: We propose trocar redesigns to overcome specific causes of gas leaks. Moreover, an international testing standard for CO2 leakage for all new trocars and instruments is needed so surgical teams can avoid this potential health hazard when selecting new equipment.


Assuntos
Dióxido de Carbono , Laparoscopia , Falha de Equipamento , Humanos , Laparoscopia/métodos , Instrumentos Cirúrgicos/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA