Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Vet Clin Pathol ; 36(3): 234-9, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17806070

RESUMO

BACKGROUND: Lactate concentration often is quantified in systemically ill dogs and interpreted based on human data. To our knowledge, there are no published clinical studies evaluating serial lactate concentrations as a prognostic indicator in ill dogs. OBJECTIVES: Our objective was to perform a prospective study, using multivariate analysis, to determine whether serial lactate concentrations were associated with outcome in ill dogs requiring intravenous fluids. METHODS: Eighty sick dogs had lactate concentrations evaluated, using an analyzer that measures lactate in the plasma fraction of heparinized whole blood, at 0 hours and 6 hours after initiation of treatment. Severity of illness and outcome (survivor, nonsurvivor) were determined by reviewing the patient's record 2 weeks after admission. Lactate concentrations, age, body weight, gender, and severity of illness were evaluated using multivariate analysis to determine their effects on outcome. RESULTS: Dogs with lactate concentrations greater than the reference interval at 6 hours were 16 times (95% confidence interval = 2.32-112.71 times, P <.01) more likely not to survive compared to dogs with lactate concentrations within the reference interval. Lactate concentrations above the reference interval at 0 hours were not significantly related to outcome. However, hyperlactatemia that did not improve by > or = 50% within 6 hours was significantly associated with mortality (P = .024). CONCLUSION: Dogs with a lactate concentration higher than the reference interval at 6 hours were more likely not to survive. These results indicate an association between lactate concentration and outcome and emphasize the importance of serial lactate concentrations in evaluating prognosis.


Assuntos
Doenças do Cão/sangue , Ácido Láctico/sangue , Envelhecimento , Animais , Peso Corporal , Cães , Feminino , Masculino , Valores de Referência , Caracteres Sexuais , Fatores de Tempo , Resultado do Tratamento
2.
Vet Clin Pathol ; 36(3): 261-6, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17806074

RESUMO

BACKGROUND: Lactate concentrations are increasingly quantified in dogs using point-of-care instruments, but often without canine-specific method evaluation and instrument-specific reference intervals. OBJECTIVES: The objectives of this study were to 1) determine the precision of the Accutrend (Roche Diagnostics) for lactate determination in dogs, 2) determine the accuracy of the Accutrend using the Rapidlab 865 (Bayer Diagnostics) as the reference method, and 3) establish and compare reference intervals for lactate concentration in clinically healthy dogs for both instruments. METHODS: Precision was evaluated using low and high control materials, and variable (1 drop) and fixed (25 microL) sample volumes. Accuracy was determined by comparing lactate concentrations obtained with the Accutrend with those from the Rapidlab 865 in 273 heparinized canine jugular venous blood samples from 100 clinically healthy dogs and 107 systemically ill dogs (173 samples). Lactate reference intervals were established for both analyzers using data from the 100 clinically healthy dogs. RESULTS: The precision of the Accutrend was good (coefficients of variation, < or = 5.3%) for 25-microL samples but not when a drop was used. Lactate concentrations obtained on the Accutrend correlated poorly with those from the Rapidlab 865 (r = 0.864, mean bias = 0.66 mmol/L, 95% confidence interval [CI] = 0.57-0.76 with 95% limits of agreement = -0.87 (lower limit, 95% CI = -1.03 to -0.71) and 2.20 (upper limit, 95% CI = 2.04 to 2.36). The reference interval for canine lactate concentration on the Accutrend was 1.2-3.1 mmol/L compared with 0.46-2.31 mmol/L on the Rapidlab. CONCLUSION: Although precision was good with fixed sample volumes, blood lactate concentrations obtained on the Accutrend were significantly different than those on the Rapidlab 865, with systematic and random errors resulting in a positive bias. Further evaluation of the Accutrend is required before its use in dogs can be recommended.


Assuntos
Análise Química do Sangue/veterinária , Doenças do Cão/sangue , Ácido Láctico/sangue , Animais , Análise Química do Sangue/instrumentação , Cães , Feminino , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA