1.
Int J Oral Maxillofac Implants ; 38(3): 607-618, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37279224

RESUMO

PURPOSE: To determine the biologic and biomechanical effects of two implant drilling protocols on the cortical bone around implants subjected to immediate loading. MATERIALS AND METHODS: A total of 48 implants were inserted into the mandibles of six sheep following one of two drilling protocols: undersized preparation (US; n = 24) and nonundersized preparation (NUS; n = 24). Immediately after implant insertion, an abutment was placed on each implant and 36 implants were subjected to 10 sessions of dynamic vertical loads (1,500 cycles, 1 Hz) of 25 N or 50 N. Insertion torque value (ITV) was recorded at implant installation. Resonance frequency analysis (RFA) was measured at implant insertion and at each loading session. Fluorochrome was administered at day 17, and the animals were euthanized after 5 weeks. The removal torque values (RTVs) were measured, and samples underwent histomorphometric, µCT (microcomputed tomography), and fluorescence image acquisition analyses. The bone volume density (BV/TV), bone-to-implant contact (BIC), bone area fraction occupancy (BAFO), and fluorochrome stained bone surface (MS) were calculated. A linear mixed model analysis was performed, and Pearson paired correlation was calculated. RESULTS: Five implants from the NUS group failed, with a mean ITV of 8.8 Ncm and an RFA value of 57. The mean ITVs for US group and NUS group were 80.5 (± 14) Ncm and 45.9 (± 25) Ncm, respectively (P < .001). No differences were noted in the RFA values from the time of implant insertion until the end of the study. No differences in RTV, BV/TV, BAFO, or MS were observed between the groups. Intense new bone formation took place in the NUS group implants that were subjected to load. CONCLUSIONS: Undersized preparation of cortical bone ensured a greater BIC compared to a nonundersized preparation. Moreover, this study demonstrated that immediate loading did not interfere with the osseointegration process, but loading induced intense new bone formation in the NUS group. It is not recommended to immediately load the implants when the clinically perceived primary stability is lower than an ITV of 10 Ncm and an RFA value of 60. Int J Oral Maxillofac Implants 2023;38:607-618. doi: 10.11607/jomi.9949.


Assuntos
Implantes Dentários , Animais , Ovinos , Microtomografia por Raio-X , Corantes Fluorescentes , Implantação Dentária Endóssea/métodos , Osseointegração , Torque
2.
Clin Oral Implants Res ; 34(3): 254-262, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36695016

RESUMO

OBJECTIVES: The aim of this study was to evaluate whether salivary contamination during placement of implants with different surface characteristics affects osseointegration in native and in augmented bone areas. MATERIALS AND METHODS: Forty eight implants with machined surface (MS) and 48 implants with moderately rough surface (RS) were tested in the calvaria of 12 sheep. At the first surgery, 64 bony critical defects were randomly created and were subsequently augmented with two materials (autogenous or bovine bone). After 5 weeks of graft healing, 8 implants were placed per sheep, in native bone and in the centre of the augmented defects. Forty eight implants were soaked with saliva before placement (contaminated group [CG]), while 48 implants were not (non-contaminated group [NCG]). Five weeks after implant placement, bone-to-implant contact (BIC) and bone material area fraction occupancy (BMAFO) were calculated histomorphometrically. RESULTS: Saliva contamination showed a significant negative effect (p = .000) on BIC, especially in augmented areas. RS showed significant positive effect on BIC, compared to MS (p = .000), while there were no significant differences for different bone conditions (p = .103). For BMAFO, the contamination showed a significantly negative affect (p = .000), while there were no significant differences for surface characteristics (p = .322) and for bone condition (p = .538). CONCLUSION: Saliva contamination during dental implant placement has a negative effect on osseointegration in augmented areas. Moderately rough surface has a possible advantage in the aspect of initial bone to implant contact. However, it seems to be advisable to avoid saliva contamination especially for implants placed in augmented bone areas.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Animais , Bovinos , Ovinos , Implantação Dentária Endóssea/métodos , Osseointegração , Crânio , Propriedades de Superfície , Titânio
3.
J Prosthodont Res ; 67(1): 23-34, 2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-35321991

RESUMO

PURPOSE: There is no clinical consensus to determine the right balance between underpreparation and marginal bone level changes. The purpose of this systematic review and meta-regression was to investigate the influence of the type of drilling preparation of the implant site in relation to the bone mineral density on the clinical success, expressed in terms of the MBL and implant failure rate. STUDY SELECTION: A thorough search was performed using the digital databases MEDLINE PubMed, EMBASE, and Cochrane Central Register of Controlled Trials by entering research lines or various combinations of free words. The main keywords used were "dental implants", "bone density", and "torque". RESULTS: The mean bone resorption in the conventional preparation group was -0.43 (± 0.28) mm, whereas it was -0.80 (± 0.37) mm in the underprepared group. For the D1/D2/D3 bone group, the slope was significantly different from zero and linearity; the D4 bone group slope was not significantly different from zero and was almost parallel, although it was significantly different from linearity. The box and whiskers plot shows that the MBL in underprepared sites tended to be significantly higher with a higher variation than that in conventionally prepared sites. CONCLUSIONS: Within its limits, our meta-regression analysis showed that MBL is influenced by the type of drilling preparation and bone mineral density. In particular, a lower MBL was observed in the D1 bone with conventional preparation than with underpreparation. Moreover, a greater implant-to-osteotomy site mismatch was positively associated with greater MBLs in the bone densities of D1/D2/D3.


Assuntos
Reabsorção Óssea , Implantação Dentária Endóssea , Humanos , Densidade Óssea , Osteotomia , Torque
4.
J Prosthodont Res ; 67(3): 337-347, 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-36372438

RESUMO

PURPOSE: The aim of this study was to review the literature on current surface modification strategies used to improve the binding efficiency of an emerging biological material, polyetheretherketone (PEEK), with bone and soft tissues. STUDY SELECTION: This review was based on articles retrieved from PubMed, Google Scholar, Web of Science, and ScienceDirect databases. The main keywords used during the search were "polyetheretherketone (PEEK)," "implant," "surface modification," "biomaterials," "bone," "osseointegration," and "soft tissue." RESULTS: The suitability of PEEK surface modification strategies has been critically analyzed and summarized here. Many cell and in vivo experiments in small animals have shown that the use of advanced modification technologies with appropriate surface modification strategies can effectively improve the surface inertness of PEEK, thereby improving its binding efficiency with bone and soft tissues. CONCLUSIONS: Surface modifications of PEEK have revealed new possibilities for implant treatment; however, most results are based on in vitro or short-term in vivo evaluations in small animals. To achieve a broad application of PEEK in the field of oral implantology, more in vivo experiments and long-term clinical evaluations are needed to investigate the effects of various surface modifications on the tissue integration ability of PEEK to develop an ideal implant material.


Assuntos
Materiais Biocompatíveis , Implantes Dentários , Animais , Materiais Biocompatíveis/farmacologia , Polímeros/farmacologia , Polietilenoglicóis/farmacologia , Cetonas/farmacologia , Osseointegração
5.
J Clin Med ; 11(7)2022 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-35407622

RESUMO

The aim of the present retrospective study was to assess marginal bone changes around implants restored with different prosthetic emergence profile angles. Patients were treated with implants supporting fixed dentures and were followed for 3 years. Marginal bone levels (MBL) measured at the prosthesis installation (t0) and at the 3-year follow-up visit (t1) were considered. The MBL change from t0 to t1 was investigated. Two groups were considered: Group 1 for restorations with an angle between implant axis and prosthetic emergence profile >30°, and Group 2 for those with an angle ≤30°, respectively. Moreover, peri-implant soft tissue parameters, such as the modified bleeding index (MBI) and plaque index (PI) were assessed. Seventy-four patients were included in the analysis and a total of 312 implants were examined. The mean EA in groups 1 and 2 was 45 ± 4 and 22 ± 7 degrees, respectively. The mean marginal bone level change (MBL change) of 0.06 ± 0.09 mm and 0.06 ± 0.10 mm were, respectively, in groups 1 and 2. The difference in the MBL change between the two groups was not statistically significant (p = 0.969). The MBL change does not seem to be influenced by the emergence angle for implants with a stable internal conical connection and platform-switching of the abutment diameter.

6.
Artigo em Inglês | MEDLINE | ID: mdl-35353090

RESUMO

Implant therapy for tooth loss in the molar area is challenging due to the anatomical limitations, requiring bone augmentation procedures that are associated with high surgical complexity and long postsurgical recovery. Recently, many studies have demonstrated the usefulness of short implants. However, few studies have been performed in Japanese patients to evaluate peri-implant bone changes, changes in peri-implant epithelial tissue, and patient satisfaction. The present study included 16 patients (5 men, 11 women; mean age: 60 years) who received 26 short (6-mm) implants. Changes in peri-implant bone and epithelial tissue were measured radiographically at superstructure loading and after 2 years. Peri-implant pocket probing depth was measured at the epithelial tissue and compared at both time points. Patient satisfaction was graded using the Oral Health Impact Profile (OHIP-14) before treatment and at follow-up. The mean mesial and distal bone levels were -0.05 mm and 0.37 mm at loading, respectively, and were 0.33 mm and 0.53 mm after 2 years, respectively. Significant peri-implant bone formation for mesial and distal bone levels at both time points were determined by Wilcoxon signed-rank test. Mean probing depth increased slightly, from 3.03 mm at loading to 3.33 mm after 2 years, but no significant difference was found. The OHIP-14 found that patient satisfaction levels increased after 2 years. Using 6-mm short implants in sites with insufficient bone levels can be a highly beneficial treatment option for patients, as it avoids the need for bone augmentation. However, more long-term and detailed studies on the clinical outcomes for these implants are required.


Assuntos
Implantes Dentários , Satisfação do Paciente , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Feminino , Seguimentos , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
7.
Clin Oral Implants Res ; 33(1): 78-93, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34617341

RESUMO

OBJECTIVES: This randomised controlled trial compares the 3-year outcomes, that is, marginal bone-level (MBL) changes and clinical parameters, between an abutment-level (AL) and implant-level (IL) connection for implants with an internal conical connection (ICC) supporting a screw-retained fixed partial denture. MATERIAL AND METHODS: Fifty patients with 119 implants were randomly allocated to either the AL or IL group. Radiographic and clinical examinations were performed after one, two, and 3 years. A linear mixed model was used to evaluate the differences between groups. RESULTS: The MBL change was not significantly different between the groups at any point. The MBL was 0.12 ± 0.31 mm (AL) and 0.23 ± 0.26 mm (IL) after 1 year; 0.15 ± 0.34 mm (AL) and 0.17 ± 0.22 mm (IL) after 2 years; 0.18 ± 0.39 mm (AL) and 0.15 ± 0.21 mm (IL) after 3 years. The bleeding on probing was 43.44 ± 39.24% (AL) and 58.19 ± 41.20% (IL) after 1 year; 35.78 ± 39.22% (AL) and 50.43 ± 41.49% (IL) after 2 years; 51.27 ± 44.63% (AL) and 49.57 ± 37.31% (IL) after 3 years and was significantly different (p = .025) between 1 and 2 years. The probing depth showed a significant difference at each time point while the plaque was not significant between the groups. The overall technical, biological and prosthetic complication rates were 5.04%, 3.36%, and 16.00%, respectively. CONCLUSIONS: The MBL change was similar in the groups. The slight differences in the soft tissue complications between the groups are likely not of clinical relevance. An IL connection is considered to be a valid alternative to an AL set-up in ICC implants.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Parafusos Ósseos , Prótese Parcial Fixa , Humanos
8.
Clin Oral Implants Res ; 32(1): 44-59, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33222296

RESUMO

OBJECTIVES: This RCT compares marginal bone level (MBL) change and the clinical parameters after a 3-year function in maxillary implant-supported fixed complete dentures (FCDs) treated with four-implants (4-I) or six-implants (6-I). MATERIAL AND METHOD: Three centres treated 56 patients with 280 implants allocated to the 4-I or 6-I group. Radiographic and clinical examinations were performed. The primary outcome was to investigate MBL change between the groups. RESULTS: Implant survival rates were 100% and 99% in the 4-I and 6-I groups, respectively. Considering the clustering effects, the MBL change was not significantly different between the groups over the 3-year follow-up. The MBL in the 4-I group was 0.30 ± 0.50 mm at baseline, 0.24 ± 0.31 mm at 1 year and 0.24 ± 0.38 mm at 3 years. In the 6-I group, MBL was 0.14 ± 0.32 mm at baseline, 0.16 ± 0.35 mm at 1 year and 0.12 ± 0.26 mm at 3 years. There was a statistically significant difference between the groups at BL and 3Y. No significant differences between the groups were reported for clinical parameters at each time point as well as in between the visits. The technical and biological complications rates were 1.6% and 6.0%, respectively. Prosthetic complications affected 25 FCDs (47.2%). CONCLUSION: Marginal bone level change revealed a stable condition in the 3-year period in the two groups. Few technical and biological complications occurred apart from the chipping/fracture of the prosthetic teeth. Four-implant is a feasible solution if the rehabilitation is oriented towards the most cost-effective treatment and towards avoiding bone augmentation procedures. Clinicians have to consider the potential required visits for prosthetic maintenance.


Assuntos
Implantes Dentários , Prótese Maxilofacial , Prótese Dentária Fixada por Implante , Prótese Total , Seguimentos , Humanos , Titânio , Resultado do Tratamento
9.
J Oral Implantol ; 47(2): 163-168, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32663272

RESUMO

This study aimed to evaluate the effect of surface hydrophilicity on the biomechanical aspects of osseointegration of dental implants in the tibia and femur of rabbits. Forty-eight mature female New Zealand White rabbits were included, and 96 commercially pure, Grade 4, titanium dental implants (control group), and 96 implants of same macro geometry with the hydrophilic surface (test group) were used in this study. One osteotomy was performed in each tibia and femur on both sides of the rabbit, and four implants were placed in each rabbit. Control and test groups were randomly allocated on the left and right sides. During surgery, insertion torque (ITQ) value of the complete implant placement was recorded. After healing periods of 0, 2, 4, and 8 weeks after surgery, implant stability quotient (ISQ) value, and removal torque (RTQ) values were measured. No statistical difference was observed for ITQ, for ISQ and for RTQ between the control group and test group in tibia/femur for all time periods. The effect of hydrophilic properties on moderately roughened surfaces has no impact in terms of biomechanical outcomes (ISQ values and RTQ values) after a healing period of 2 to 8 weeks in rabbit tibias /femurs.


Assuntos
Implantes Dentários , Osseointegração , Animais , Fenômenos Biomecânicos , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Feminino , Interações Hidrofóbicas e Hidrofílicas , Coelhos , Propriedades de Superfície , Tíbia/cirurgia , Titânio , Torque
10.
Materials (Basel) ; 13(14)2020 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-32668745

RESUMO

BACKGROUND: There is limited information on the effect of the connection between subcrestally placed implants and abutments on marginal bone levels. The aim of the present retrospective study was to evaluate marginal bone levels after definitive prosthesis delivery around implants with an internal 5° conical connection placed in a subcrestal position. MATERIALS AND METHODS: Patients treated with fixed prostheses supported by implants placed at a subcrestal level between 2012 and 2018 were recalled for a follow-up examination. All implants had 5° internal conical connection with platform switching. Radiographic marginal bone level (MBL) was measured. MBL change between prosthetic delivery (t0) and follow-up examination (t1) was calculated. A multiple regression model was performed to identify the most significant predictors on MBL change. RESULTS: Ninety-three patients and 410 implants, with a mean follow-up of 2.72 ± 1.31 years, were examined. Mean MBL was -1.09 ± 0.65 mm and -1.00 ± 0.37 mm at t0 and t1, respectively, with a mean bone remodeling of 0.09 ± 0.68 mm. An implant's vertical position in relation to the bone crest, the year of follow up and the presence of type-2 controlled diabetes were demonstrated to be influencing factors for MBL modifications. CONCLUSIONS: Subcrestally placed implants with platform switching and internal conical connection maintained stable bone levels over a mean follow-up of more than 2 years. How a tight internal conical connection between abutment and implant may contribute to this clinical evidence should be more deeply investigated. MBL variations seem to be mostly influenced by an implant's vertical position and presence of type-2 controlled diabetes.

11.
J Oral Implantol ; 46(3): 182-189, 2020 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-32582919

RESUMO

The aim of this study was to evaluate the influence of bone quality, drilling technique, implant diameter, and implant length on insertion torque (IT) and resonance frequency analysis (RFA) of a prototype-tapered implant with knife-edge threads. The investigators hypothesized that IT would be affected by variations in bone quality and drilling protocol, whereas RFA would be less influenced by such variables. The investigators implemented an in vitro experiment in which a prototype implant was inserted with different testing conditions into rigid polyurethane foam blocks. The independent variables were: bone quality, drilling protocol, implant diameter, and implant length. Group A implants were inserted with a conventional drilling protocol, whereas Group B implants were inserted with an undersized drilling protocol. Values of IT and RFA were measured at implant installation. IT and RFA values were significantly correlated (Pearson correlation coefficient: 0.54). A multivariable analysis showed a strong model. Higher IT values were associated with drilling protocol B vs A (mean difference: 71.7 Ncm), implant length (3.6 Ncm increase per mm in length), and substrate density (0.199 Ncm increase per mg/cm3 in density). Higher RFA values were associated with drilling protocol B vs A (mean difference: 3.9), implant length (1.0 increase per mm in length), and substrate density (0.032 increase per mg/cm3 in density). Implant diameter was not associated with RFA or IT. Within the limitations of an in vitro study, the results of this study suggest that the studied implant can achieve good level of primary stability in terms of IT and RFA. A strong correlation was found between values of IT and RFA. Both parameters are influenced by the drilling protocol, implant length, and substrate density. Further studies are required to investigate the clinical response in primary stability and marginal bone response.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Densidade Óssea , Retenção em Prótese Dentária , Análise de Frequência de Ressonância , Torque
12.
J Mech Behav Biomed Mater ; 103: 103598, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32090927

RESUMO

PURPOSE: The aim of this multi-scale in silico study was to evaluate the influence of resorption cavities on the mechanical properties and load distribution in cortical bone after implant placement with two different drilling protocols. MATERIAL AND METHODS: Two different micro-scale bone structures were assessed: cortical bone models with cavities (test) and without cavities (control) were designed from µCT data. In a macro-scale model, representing a mandibular ridge, oblique load of 150 N was applied on the implant-abutment. Maximum principal stress/strain, and shear stress/strain were calculated in the macro- and micro-scale models. RESULTS: Test presented anisotropic material properties. In tests, significantly greater maximum values of Maximum principal stress/strain were calculated in micro-scale model. These values were located at the implant neck area in the macro-scale model and in the proximity of cavities in the micro-scale model respectively. Greater values of shear stress/strain were found in the test along the mandibular horizontal plane. CONCLUSIONS: Cortical bone with resorption cavities following undersized drilling showed an impaired load distribution compared with bone without cavities. Subsequently, stress/strain distribution suggests that this bone model is more prone to microdamage, thus delaying the healing process.


Assuntos
Osso Cortical , Implantes Dentários , Fenômenos Biomecânicos , Simulação por Computador , Osso Cortical/diagnóstico por imagem , Análise do Estresse Dentário , Análise de Elementos Finitos , Estresse Mecânico
13.
J Clin Med ; 8(8)2019 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-31405207

RESUMO

BACKGROUND: The intraosseous temperature during implant installation has never been evaluated in an in vivo controlled setup. The aims were to investigate the influence of a drilling protocol and implant surface on the intraosseous temperature during implant installation, to evaluate the influence of temperature increase on osseointegration and to calculate the heat distribution in cortical bone. METHODS: Forty Brånemark implants were installed into the metatarsal bone of Finnish Dorset crossbred sheep according to two different drilling protocols (undersized/non-undersized) and two surfaces (moderately rough/turned). The intraosseous temperature was recorded, and Finite Element Model (FEM) was generated to understand the thermal behavior. Non-decalcified histology was carried out after five weeks of healing. The following osseointegration parameters were calculated: Bone-to-implant contact (BIC), Bone Area Fraction Occupancy (BAFO), and Bone Area Fraction Occupancy up to 1.5 mm (BA1.5). A multiple regression model was used to identify the influencing variables on the histomorphometric parameters. RESULTS: The temperature was affected by the drilling protocol, while no influence was demonstrated by the implant surface. BIC was positively influenced by the undersized drilling protocol and rough surface, BAFO was negatively influenced by the temperature rise, and BA1.5 was negatively influenced by the undersized drilling protocol. FEM showed that the temperature at the implant interface might exceed the limit for bone necrosis. CONCLUSION: The intraosseous temperature is greatly increased by an undersized drilling protocol but not from the implant surface. The temperature increase negatively affects the bone healing in the proximity of the implant. The undersized drilling protocol for Brånemark implant systems increases the amount of bone at the interface, but it negatively impacts the bone far from the implant.

14.
Int J Oral Maxillofac Implants ; 34(2): 320-328, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30883615

RESUMO

PURPOSE: To evaluate the effect of misfit at implant-level fixed partial dentures (ILFPDs) and marginal bone support on the generation of implant cracks. MATERIALS AND METHODS: This in vitro study included a mechanical fatigue test and finite element analysis. A mechanical cycling loading test was performed using 16 experimental models, each consisting of two parallel implants subdivided into four groups based on the misfit and the supporting bone condition. The framework, firmly seated at implants, was dynamically loaded vertically with a force of 1,600/160 N and 15 Hz for 1 × 106 cycles. Optical microscope, scanning electron microscope (SEM), and computed tomography three-dimensional (CT-3D) analyses were performed to detect impairments. Finite element models, representing the setups in the mechanical fatigue test, were used to represent the fatigue life. RESULTS: None of the mechanical components presented distortion or fracture at the macroscopic level during the test. In a microscopy evaluation, the fatigue test revealed scratches visible in the inner part of the conical portion of the implants regardless of the groups. SEM and CT-3D analysis revealed one implant from the misfit/no bone loss group with a microfracture in the inner part of the conical interface. The simulated effective stress levels in the coronal body were higher in the misfit groups compared with the no misfit groups. The misfit groups presented effective stress levels, above 375 MPa, that penetrated the entire wall thickness. The no bone loss group presented an effective stress level above 375 MPa along its axial direction. In the no misfit group, the area presenting effective stress levels above 375 MPa in the conical connection was larger for the bone loss group compared with the no bone loss group. CONCLUSION: This study confirmed that implant fracture is an unlikely adverse event. A clear pattern of effective distribution greater than fatigue limit stresses could be noticed when the misfit was present. The dynamic load simulation demonstrated that the crack is more likely to occur when implants are fully supported by marginal bone compared with a bone loss scenario. Within the limitations of this study, it is speculated that marginal bone loss might follow the appearance of an undetected crack. Further research is needed to develop safe clinical protocols with regard to ILFPD.


Assuntos
Perda do Osso Alveolar/fisiopatologia , Implantes Dentários/efeitos adversos , Prótese Dentária Fixada por Implante/efeitos adversos , Prótese Parcial Fixa , Estresse Mecânico , Fenômenos Biomecânicos , Análise do Estresse Dentário , Análise de Elementos Finitos , Humanos , Falha de Prótese/etiologia , Ajuste de Prótese
15.
Clin Implant Dent Relat Res ; 21(2): 238-246, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30690848

RESUMO

BACKGROUND: Screw-retained fixed partial dentures (FPD) have shown a lower incidence of biologic complications and an easier retrievability compared with cemented FPD. PURPOSE: To compare the marginal bone loss at conical connection implant restored with a screw retained cobalt-chrome FPD in an implant-level (IL) or an abutment-level (AL) setup. MATERIALS AND METHODS: Patients with at least two adjacent missing teeth were randomly allocated to be restored with IL or AL FPD. Periapical radiographs and clinical examination were taken at implant placement, prosthetic connection, 6 and 12 months to evaluate marginal bone loss (MBL), and soft tissue conditions. Complications were used to calculate prognostic indexes. RESULTS: Fifty patients were treated with 50 FPD supported by 119 implants. The difference of MBL between the IL and AL groups was statistically significant (P = 0.003). At 1 year, MBL was 0.086 ± 0.313 mm and 0.005 ± 0.222 mm in the IL and AL groups, respectively. The presence of BoP increased with time in IL, whereas it decreased in AL group (P < 0.001). A minor complication was encounted in one FPD. CONCLUSIONS: A low grade of MBL was present after 1 year. IL showed greater amount of MBL and soft tissue inflammation indexes than AL. In FPD, AL may be a safer procedure than IL setup in order to preserve a healthy periimplant tissue.


Assuntos
Implantes Dentários , Prótese Parcial Fixa , Perda do Osso Alveolar , Parafusos Ósseos , Cobalto , Prótese Dentária Fixada por Implante , Humanos
16.
Clin Oral Implants Res ; 29(7): 707-715, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29781224

RESUMO

OBJECTIVE: The aim of this study was to investigate the extent of cortical bone remodeling between two different drilling protocols by means of histomorphometric, µ-CT, and biomechanical analyses. MATERIAL AND METHODS: A total of 48 implants were inserted into the mandible of six sheep following two drilling protocols: Group A (Test, n = 24), undersized preparation; Group B (Control, n = 24), non-undersized preparation. The animals were euthanatized to obtain 5 and 10 weeks of implantation time. Removal torque (RTQ) was measured on 12 implants of each group and the peri-implant bone was µ-CT scanned. Bone volume density (BV/TV) was calculated in pre-determined cylindrical volumes, up to 1.5 mm from implant surface. Non-decalcified histology was prepared on the remaining 12 implants from each group, where total bone-to-implant contact (totBIC) and newly-formed BIC (newBIC) was measured. Bone Area Fraction Occupancy (BAFO) was determined in pre-determined areas up to 1.5 mm from implant surface. Paired sample t test or Wilcoxon signed-rank test was used to investigate differences between the groups. RESULTS: Group A presented significantly increased RTQ value at 5 weeks, while no difference was observed at 10 weeks. Group B presented increased BV/TV value at 5 weeks. Both groups showed comparable values for totBIC at both time-points. However, Group A presented significantly lower newBIC at 5 weeks. Higher BAFO was observed in Group B at 5 weeks. CONCLUSIONS: Implants inserted into undersized sites has an increased biomechanical performance, but provoked major remodeling of the cortical bone during the early healing period compared to non-undersized preparations. After 10 weeks, no difference was observed.


Assuntos
Osso Cortical/cirurgia , Implantação Dentária Endóssea/métodos , Mandíbula/cirurgia , Animais , Fenômenos Biomecânicos , Remodelação Óssea , Osso Cortical/anatomia & histologia , Osso Cortical/diagnóstico por imagem , Feminino , Mandíbula/anatomia & histologia , Mandíbula/diagnóstico por imagem , Osseointegração , Ovinos , Torque , Microtomografia por Raio-X
17.
Int J Oral Maxillofac Implants ; 32(6): 1288-1295, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29140373

RESUMO

PURPOSE: To evaluate insertion torque value (ITV) and marginal bone loss (MBL) of an implant system after a clinically perceived bone quality-adapted drilling. MATERIALS AND METHODS: This multicenter retrospective study included patients treated with implants, conventionally loaded, in completely healed sites. Operators customized the osteotomy preparation according to radiographic assessment and their perception of bone quality. Drilling sequence, bone quality, and ITV were recorded at the time of surgery. Radiographs were taken at the time of implant placement and permanent restoration. MBL between implant placement and permanent restoration was calculated. The implant was used as the statistical unit. Demographic and implant characteristics were shown by means of descriptive statistics. Outcome values were compared using analysis of variance (ANOVA) and Kruskal-Wallis tests. Multiple regression models were used to test the effect of independent variables on ITV and MBL. RESULTS: One hundred eighty-eight implants placed in 87 patients were included in the analysis. The mean observation period was 144 ± 59 days. The mean ITV was 30.8 ± 15.1 Ncm. ITV differed significantly based on arches (mandible/maxilla) (P = .001), bone quality (P < .001), implant diameter (P = .032), and drilling protocol (P = .019). Median MBL was 0.05 mm (0.00; 0.24). A significant difference was found between the mandible and maxilla (P = .008) and between drilling protocols (P = .011). In particular, significantly higher MBL was found in the undersized drilling protocol. Multiple regression analysis showed that ITV was influenced by bone quality and implant diameter. MBL was influenced by bone quality, implant diameter, ITV, and the interaction between bone quality and ITV. It was estimated that MBL was greater with increased bone density and ITV. CONCLUSION: Excessive ITV in dense bone can cause negative marginal bone responses. A presurgical radiographic assessment and the perception of bone quality are necessary to select an optimal drilling protocol and to minimize surgical trauma.


Assuntos
Densidade Óssea , Implantação Dentária Endóssea/métodos , Implantes Dentários , Maxila/cirurgia , Planejamento de Prótese Dentária , Feminino , Humanos , Masculino , Mandíbula/cirurgia , Maxila/diagnóstico por imagem , Pessoa de Meia-Idade , Osteotomia/métodos , Estudos Retrospectivos , Torque
18.
Implant Dent ; 26(5): 756-761, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28945671

RESUMO

OBJECTIVE: To evaluate in vitro the sealing capability at the prosthetic connection interface of 2 conometric systems. MATERIALS AND METHODS: Two conometric systems with the same design and different material were used, for a total of 24 samples. Each sample was assembled by a tapered abutment and respective coping. In group A, the copings were made of gold, whereas in group B they were made of PEEK. Three µL of mix bacterial suspension (Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and Fusobacterium nucleatum species) was inoculated into the abutment screw hole, and the coping was inserted on the abutment. Samples were immersed into culture tubes and incubated for 24, 48, and 72 hours into anaerobic conditions. Visual evaluation of turbidity was performed at each time point. Qualitative-quantitative assessment using real-time polymerase chain reaction was performed at 72 hours. Any difference between the groups was checked by means of Fisher exact test. RESULTS: Microbial leakage occurred in both groups, and there was no statistically significant difference between groups. Microbial concentration resulted in a presence inferior to 1 × 10 copies/µL in all positive assemblies. CONCLUSIONS: Because of the low bacterial count, it can be concluded that a minimal bacterial infiltration may be allowed by conometric interfaces for prosthetic connection.


Assuntos
Dente Suporte , Implantes Dentários/microbiologia , Infiltração Dentária/microbiologia , Aggregatibacter actinomycetemcomitans , Dente Suporte/efeitos adversos , Projeto do Implante Dentário-Pivô/efeitos adversos , Fusobacterium nucleatum , Humanos , Técnicas In Vitro , Porphyromonas gingivalis
19.
Int J Oral Maxillofac Implants ; 31(6): 1247-1263, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27861649

RESUMO

PURPOSE: To compile the current evidence on biomechanical, biologic, and clinical outcomes of undersized surgical preparation protocols in dental implant surgery. MATERIALS AND METHODS: An electronic search using three different databases (PubMed, Web of Science, and Cochrane Library) and a manual hand search were performed including in vitro, animal, and clinical studies published prior to October 2015. Studies in which an undersized drilling protocol was compared with a nonundersized drilling protocol were included. RESULTS: From an initial selection of 1,655 titles, 29 studies met the inclusion criteria, including 14 biomechanical, 7 biologic, 6 biologic and biomechanical, and 2 clinical. Due to methodologic variation, meta-analysis was not performed. Several studies showed that implants inserted with an undersized drilling approach reached a significantly higher insertion torque value than conventional drilling in low-density substrates, while this effect is less evident if a thick cortical layer is present. Similar results in terms of boneto-implant contact (BIC) were achieved in the longer term between implants inserted with undersized and nonundersized protocols. Results in the short term were inconclusive. Clinical studies did not show negative outcomes for undersized drilling, although clinical evidence was sparse. No data are available on marginal bone loss. CONCLUSION: From the biomechanical standpoint, an undersized drilling protocol is effective in increasing insertion torque in low-density bone. Biologic response in long-term healing after undersized implant placement is comparable to that in the nonundersized surgical drilling protocol. Clinical studies indicate that performing an undersized drilling protocol on low-density bone is a safe procedure; however, more extensive studies are needed to confirm these data.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Animais , Planejamento de Prótese Dentária , Humanos , Modelos Dentários , Propriedades de Superfície , Torque
20.
Artigo em Inglês | MEDLINE | ID: mdl-25660828

RESUMO

OBJECTIVES: The clinical efficacy of a wearable pulsed electromagnetic field (PEMF) therapy device was assessed in terms of pain and quality of healing after tooth extraction. STUDY DESIGN: This randomized, parallel design, placebo-controlled study involved 120 patients undergoing unilateral mandibular third molar extraction and assigned to three groups after surgery. Test and placebo patients wore enabled or disabled PEMF devices, respectively, and controls wore no device. Patients recorded pain (on the visual analog scale) and analgesic use for a week, after which healing complications were assessed. RESULTS: Test patients had only slightly lower visual analog scale scores and analgesic use, but significantly fewer cases of dehiscence than placebo patients. CONCLUSIONS: PEMF therapy delivered by a wearable device improved soft tissue healing and may be a useful adjunct for pain management after oral surgery.


Assuntos
Campos Eletromagnéticos , Mandíbula/cirurgia , Dente Serotino/cirurgia , Dor Pós-Operatória/terapia , Extração Dentária , Adulto , Feminino , Humanos , Masculino , Manejo da Dor , Medição da Dor , Resultado do Tratamento