Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Curr Rheumatol Rep ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38739298

RESUMO

PURPOSE OF REVIEW: To highlight novel findings in the detection of monosodium urate deposits in vessels using dual energy computed tomography, and to discuss the potential clinical implications for gout and hyperuricemia patients. RECENT FINDINGS: Gout is an independent risk factor for cardiovascular disease. However, classical risk calculators do not take into account these hazards, and parameters to identify patients at risk are lacking. Monosodium urate measured by dual energy computed tomography is a well-established technology for the detection and quantification of monosodium urate deposits in peripheral joints and tendons. Recent findings also suggest its applicability to identify vascular urate deposits. Dual energy computed tomography is a promising tool for detection of cardiovascular monosodium urate deposits in gout patients, to better delineate individuals at increased risk for cardiovascular disease.

2.
J Arthroplasty ; 39(5): 1341-1347, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38043744

RESUMO

BACKGROUND: Femoral nerve (FN) injury is noted as a serious neurological complication following total hip arthroplasty performed via a direct anterior approach (DAA). Therefore, we aimed to clarify the anatomical course of the FN around the acetabular rim and in relation to retractor placement during DAA. METHODS: According to standard protocol, a DAA for total hip arthroplasty was performed on 69 hemipelves from formalin-preserved full-body donors. The surgery was halted after retractor placement at the anterior part of the acetabulum. Then dissection was performed to expose the FN and the iliopsoas muscle. Various measurements were taken using a reference line from the anterior superior iliac spine to the acetabulum's center. A total of 6 measurement points, one every 30° from 0° to 150° along the reference line were used to determine the association between the FN and the retractor tip (RT) and the anterior acetabular rim. RESULTS: The mean distance from the RT to the FN was 22.5 millimeters (mm). The distance from the FN to the anterior acetabular rim decreased from 0 to 90°, where it was 18.8 mm, before increasing again to 27.3 mm at 150°. CONCLUSIONS: In our cadaveric study, the FN was within 11 to 36 mm of the RT. Second, we found the FN to be closest to the anterior acetabular rim at 90° and 120°. Accordingly, special care should be taken during retractor placement, and if possible, placement at 90° and 120° avoided.

3.
J Arthroplasty ; 39(4): 1088-1092, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37918488

RESUMO

BACKGROUND: Iatrogenic vascular injury during total hip arthroplasty (THA) is rare, reported at rates of 0.05 to 0.3%, but a potentially limb-threatening and life-threatening complication. We aimed to describe safe and danger zones for the superior gluteal vessel bundle (SGV bundle) with reference to different THA approaches. METHODS: There were 27 formalin-fixed cadavers with 49 hemipelves dissected. The course and distribution of the SGV bundle were investigated with the help of anatomical landmarks like the greater trochanter, the iliac tubercle (IT), and the ischial tuberosity. RESULTS: We found and exposed the SGV bundle in all 49 specimens with no sex-specific differences. No SGV bundle was encountered up to 28 mm from the greater trochanter and up to 16 mm below the IT. The zone with the highest probability of finding the vessels was 25 to 65 mm below the IT in 39 (80%) cases - defining a danger zone (in relation to the skin incision) in the proximal fourth for the direct anterior approach, in the proximal half for the antero-lateral approach, in the proximal fifth for the direct lateral approach, and almost no danger zone for the posterior approach. CONCLUSIONS: Special care in proximal instrument placement should be taken during THA. When extending one of the surgical approaches, manipulations in the proximal, cranial surgical window should be performed with the utmost care to avoid SGV bundle injury.


Assuntos
Artroplastia de Quadril , Lesões do Sistema Vascular , Humanos , Nádegas/cirurgia , Cadáver , Fêmur , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/prevenção & controle
4.
Diagnostics (Basel) ; 13(13)2023 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-37443602

RESUMO

OBJECTIVE: To evaluate two different dual-energy computed tomography (DECT) post-processing protocols for the detection of MSU deposits in foot tendons of cadavers with verification by polarizing light microscopy as the gold standard. MATERIAL AND METHODS: A total of 40 embalmed cadavers (15 male; 25 female; median age, 82 years; mean, 80 years; range, 52-99; SD ± 10.9) underwent DECT to assess MSU deposits in foot tendons. Two postprocessing DECT protocols with different Hounsfield unit (HU) thresholds, 150/500 (=established) versus 120/500 (=modified). HU were applied to dual source acquisition with 80 kV for tube A and 140 kV for tube B. Six fresh cadavers (4 male; 2 female; median age, 78; mean, 78.5; range 61-95) were examined by DECT. Tendon dissection of 2/6 fresh cadavers with positive DECT 120 and negative DECT 150 studies were used to verify MSU deposits by polarizing light microscopy. RESULTS: The tibialis anterior tendon was found positive in 57.5%/100% (DECT 150/120), the peroneus tendon in 35%/100%, the achilles tendon in 25%/90%, the flexor halluces longus tendon in 10%/100%, and the tibialis posterior tendon in 12.5%/97.5%. DECT 120 resulted in increased tendon MSU deposit detection, when DECT 150 was negative, with an overall agreement between DECT 150 and DECT 120 of 80% (p = 0.013). Polarizing light microscope confirmed MSU deposits detected only by DECT 120 in the tibialis anterior, the achilles, the flexor halluces longus, and the peroneal tendons. CONCLUSION: The DECT 120 protocol showed a higher sensitivity when compared to DECT 150.

5.
Front Surg ; 9: 891896, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35874129

RESUMO

In humans, the incidence of congenital defects of the intraembryonic celom and its associated structures has increased over recent decades. Surgical treatment of abdominal and diaphragmatic malformations resulting in congenital hernia requires deep knowledge of ventral body closure and the separation of the primary body cavities during embryogenesis. The correct development of both structures requires the coordinated and fine-tuned synergy of different anlagen, including a set of molecules governing those processes. They have mainly been investigated in a range of vertebrate species (e.g., mouse, birds, and fish), but studies of embryogenesis in humans are rather rare because samples are seldom available. Therefore, we have to deal with a large body of conflicting data concerning the formation of the abdominal wall and the etiology of diaphragmatic defects. This review summarizes the current state of knowledge and focuses on the histological and molecular events leading to the establishment of the abdominal and thoracic cavities in several vertebrate species. In chronological order, we start with the onset of gastrulation, continue with the establishment of the three-dimensional body shape, and end with the partition of body cavities. We also discuss well-known human etiologies.

6.
Diagnostics (Basel) ; 12(5)2022 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-35626395

RESUMO

BACKGROUND: Dual-energy computed tomography (DECT) allows direct visualization of monosodium urate (MSU) deposits in joints and soft tissues. PURPOSE: To describe the distribution of MSU deposits in cadavers using DECT in the head, body trunk, and feet. MATERIALS AND METHODS: A total of 49 cadavers (41 embalmed and 8 fresh cadavers; 20 male, 29 female; mean age, 79.5 years; SD ± 11.3; range 52-95) of unknown clinical history underwent DECT to assess MSU deposits in the head, body trunk, and feet. Lens, thoracic aorta, and foot tendon dissections of fresh cadavers were used to verify MSU deposits by polarizing light microscopy. RESULTS: 33/41 embalmed cadavers (80.5%) showed MSU deposits within the thoracic aorta. 11/41 cadavers (26.8%) showed MSU deposits within the metatarsophalangeal (MTP) joints and 46.3% of cadavers demonstrated MSU deposits within foot tendons, larger than and equal to 5 mm. No MSU deposits were detected in the cranium/intracerebral vessels, or the coronary arteries. Microscopy used as a gold standard could verify the presence of MSU deposits within the lens, thoracic aorta, or foot tendons in eight fresh cadavers. CONCLUSIONS: Microscopy confirmed the presence of MSU deposits in fresh cadavers within the lens, thoracic aorta, and foot tendons, whereas no MSU deposits could be detected in cranium/intracerebral vessels or coronary arteries. DECT may offer great potential as a screening tool to detect MSU deposits and measure the total uric acid burden in the body. The clinical impact of this cadaver study in terms of assessment of MSU burden should be further proven.

7.
J Arthroplasty ; 36(1): 368-373, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32826147

RESUMO

BACKGROUND: Although the direct anterior approach (DAA) has become a standard for primary and revision total hip arthroplasty, it involves a high risk of injuring the lateral femoral cutaneous nerve (LFCN). The aim of this study is to examine the course of the LFCN in relation to various skin incisions and approach extensions used for the DAA. METHODS: We obtained 44 limbs and hemipelves from 22 formalin-preserved cadavers, in which LFCN was identified. All nerve branches of the LFCN were carefully traced. The branching pattern and the distribution in the thigh were described in relation to the standard approach for primary total hip arthroplasty, the skin crease bikini incision, the longitudinal extension, and the lazy S extension of the DAA. RESULTS: We found 31 (70.5%) Sartorius-type, 6 (13.6%) posterior-type, and 7 (15.9%) fan-type branching patterns of the LFCN. We observed 2.02 branches per hemipelvis. All fan-type LFCNs had 3 or more than 3 branches. We found that the main branch of the LFCN was medial to the primary DAA approach as well as to the lazy S extended DAA approach. The bikini incision and the incision for the longitudinal extension of the DAA crosses the main branch of the LFCN in 100% of cases. CONCLUSION: The fan-type pattern of the LFCN might be harmed by all skin incisions. Chances are high that LFCN branches could be jeopardized with a bikini-type incision and the longitudinal extension of the DAA. The risk of jeopardizing the LFCN with a lazy S-type distal extension is reduced.


Assuntos
Artroplastia de Quadril , Hepatite C Crônica , Artroplastia de Quadril/efeitos adversos , Nervo Femoral , Humanos , Reoperação , Coxa da Perna
8.
J Arthroplasty ; 36(3): 1138-1142, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33071031

RESUMO

BACKGROUND: During primary and revision total hip arthroplasty (THA) lesions of the superior gluteal nerve (SGN) can substantially compromise patient outcome. For the primary direct anterior approach (DAA) and its proximal approach extensions, especially the muscular branch entering the tensor fasciae latae (TFL) muscle is at risk. SGN lesions can result in fatty atrophy and functional loss of the TFL. Therefore, the course and branching pattern of the SGN were examined and related to the DAA and its proximal approach extension. The aim of the study is to describe safe and danger zones for the SGN with regard to the DAA and its proximal extensions. METHODS: Twenty-five formalin-fixed cadavers with 48 hemipelves were dissected. The course, distribution, and branching pattern of the SGN and its muscular branch inserting into the TFL muscle were investigated with regard to the DAA with the help of anatomical landmarks like the greater trochanter and the iliac tubercle. RESULTS: In 72.9% of the specimens the SGN passed the greater sciatic foramen superior to the piriformis muscle with one main trunk. The muscular branch of the SGN supplying the TFL divided from the main branch in 89.6% of the specimens at the level of the greater sciatic foramen. Before entering the TFL muscle the muscular branch showed a variable branching pattern in the interval between the gluteus medius and minimus. A danger zone for the SGN with regard to the DAA was found in the proximal fourth of the skin incision. CONCLUSION: Special care in proximal instrument placement should be taken during the DAA. When extending the DAA proximally manipulations in the proximal, caudal surgical window should be performed with the utmost care.


Assuntos
Artroplastia de Quadril , Hepatite C Crônica , Artroplastia de Quadril/efeitos adversos , Nádegas , Quadril , Humanos , Músculo Esquelético/cirurgia , Reoperação
9.
Biomed Tech (Berl) ; 65(2): 183-189, 2020 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-31647778

RESUMO

In the last decades, several interspinous process devices were designed as a minimally invasive treatment option for spinal stenosis. In order to minimise surgical trauma, interspinous process devices were recently discussed as an alternative posterior fixation in vertebral interbody fusions. Therefore, the purpose of this study was to evaluate the effect of a newly designed interspinous device with polyester bands (PBs) on range of motion (RoM) and centre of rotation (CoR) of a treated motion segment in comparison with an established interspinous device with spikes (SC) as well as with pedicle screw instrumentation in lumbar fusion procedures. Flexibility tests with an applied pure moment load of 7.5 Nm were performed in six monosegmental thoracolumbar functional spinal units (FSUs) in the following states: (a) native, (b) native with PB device, (c) intervertebral cage with PB device, (d) cage with SC and (e) cage with internal fixator. The resulting RoM was normalised to the native RoM. The CoR was determined of X-ray images taken in maximal flexion and extension during testing. In flexion and extension, the PB device without and with the cage reduced the RoM of the native state to 58% [standard deviation (SD) 17.8] and 53% (SD 15.7), respectively. The SC device further reduced the RoM to 27% (SD 16.8), while the pedicle screw instrumentation had the most reducing effect to 17% (SD 17.2) (p < 0.01). In lateral bending and axial rotation, the interspinous devices had the least effect on the RoM. Compared to the native state, for all instrumentations the CoR showed a small shift towards cranial. In the anterior-posterior direction, the SC device and the pedicle screw instrumentation shifted the CoR towards the posterior wall. The interspinous devices significantly reduced the RoM in flexion/extension, while in axial rotation and lateral bending only the internal fixator had a significant effect on the RoM.


Assuntos
Vértebras Lombares/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Fusão Vertebral/métodos , Humanos , Fixadores Internos , Vértebras Lombares/fisiologia , Vértebras Lombares/cirurgia , Rotação , Fusão Vertebral/instrumentação
10.
AJR Am J Roentgenol ; 213(6): 1315-1323, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31553656

RESUMO

OBJECTIVE. The objective of our study was to compare ultrasound (US) tophus and monosodium urate (MSU) deposit detection and US tophus size in the metatarsophalangeal (MTP) 1 joint with dual-energy CT (DECT) using two DECT postprocessing protocols in patients presenting with podagra. SUBJECTS AND METHODS. Seventy-five consecutive patients with podagra (66 men and nine women; mean age, 65.6 years; age range, 33-88 years) and 75 control subjects with MTP 1 joint osteoarthritis (49 men and 26 women; mean age, 63.0 years; age range, 35-87 years) prospectively underwent US and DECT between 2016 and 2018 to assess the MTP 1 joint. Two Syngovia postprocessing DECT protocols with different minimum attenuation thresholds of 150 HU (DECT 150 protocol) versus 120 HU (DECT 120 protocol) and the same maximum attenuation threshold (500 HU) and constant kilovoltage setting of tubes A and B at 80 and 140 kVp were evaluated. Interobserver variability of the two DECT protocols was calculated and compared with that of US. RESULTS. The postprocessing DECT 150 protocol was positive for tophus detection in 55 of 75 patients (73.3%) with podagra, whereas the postprocessing DECT 120 protocol detected MSU deposits in all 75 patients (100%). Tophus size assessed using the DECT 120 protocol showed an improved correlation with tophus size detected on US (p < 0.01). Interobserver variability of DECT was improved when using the DECT 120 protocol (p < 0.01). CONCLUSION. The postprocessing DECT 120 protocol enables improved visualization of MSU deposits and provides more accurate information about tophus size that better correlates with tophus size on US compared with the standard postprocessing DECT 150 protocol.


Assuntos
Artrite Gotosa/diagnóstico por imagem , Articulação Metatarsofalângica/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Ultrassonografia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ácido Úrico/análise
11.
JAMA Cardiol ; 4(10): 1019-1028, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31509156

RESUMO

Importance: The prevalence of gout has increased in recent decades. Several clinical studies have demonstrated an association between gout and coronary heart disease, but direct cardiovascular imaging of monosodium urate (MSU) deposits by using dual-energy computed tomography (DECT) has not been reported to date. Objective: To compare coronary calcium score and cardiovascular MSU deposits detected by DECT in patients with gout and controls. Design, Setting, and Participants: This prospective Health Insurance Portability and Accountability Act-compliant study included patients with gout and controls who presented to a rheumatologic clinic from January 1, 2017, to November 1, 2018. All consecutive patients underwent DECT to assess coronary calcium score and MSU deposits in aorta and coronary arteries. In addition, cadavers were assessed by DECT for cardiovascular MSU deposits and verified by polarizing microscope. Analysis began in January 2017. Main Outcomes and Measures: Detection rate of cardiovascular MSU deposits using DECT in patients with gout and control group patients without a previous history of gout or inflammatory rheumatic diseases. Results: A total of 59 patients with gout (mean [SD] age, 59 [5.7] years; range, 47-89 years), 47 controls (mean [SD] age, 70 [10.4] years; range, 44-86 years), and 6 cadavers (mean [SD] age at death, 76 [17] years; range, 56-95 years) were analyzed. The frequency of cardiovascular MSU deposits was higher among patients with gout (51 [86.4%]) compared with controls (7 [14.9%]) (χ2 = 17.68, P < .001), as well as coronary MSU deposits among patients with gout (19 [32.2%]) vs controls (2 [4.3%]) (χ2 = 8.97, P = .003). Coronary calcium score was significantly higher among patients with gout (900 Agatston units [AU]; 95% CI, 589-1211) compared with controls (263 AU; 95% CI, 76-451; P = .001) and also significantly higher among 58 individuals with cardiovascular MSU deposits (950 AU; 95% CI, 639-1261) compared with 48 individuals without MSU deposits (217 AU; 95% CI, 37-397; P < .001). Among 6 cadavers, 3 showed cardiovascular MSU deposits, which were verified by polarizing light microscope. Conclusion and Relevance: Dual-energy computed tomography demonstrates cardiovascular MSU deposits, as confirmed by polarized light microscopy. Cardiovascular MSU deposits were detected by DECT significantly more often in patients with gout compared with controls and were associated with higher coronary calcium score. This new modality may be of importance in gout population being at risk from cardiovascular disease.


Assuntos
Doenças Cardiovasculares/diagnóstico , Vasos Coronários/metabolismo , Gota/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Ácido Úrico/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/metabolismo , Cadáver , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/metabolismo , Vasos Coronários/diagnóstico por imagem , Feminino , Seguimentos , Gota/complicações , Gota/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
12.
Clin Biomech (Bristol, Avon) ; 63: 16-20, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30784786

RESUMO

BACKGROUND: Cement augmentation of pedicle screws to prevent screw loosening is associated with significant complications, such as cement leakage or bone necrosis. Therefore, an alternative strategy to improve pedicle screw anchorage has been recently developed: Polymer reinforcement of pedicle screws uses an in situ melted polymer sleeve in order to enhance screw anchorage. This biomechanical study evaluated the effect of polymer-reinforcement by comparing polymer-reinforced pedicle screws to non-augmented as well as cement-augmented screws under cyclic loading. METHODS: For each of the two comparisons (polymer-reinforced vs. non-augmented screws and polymer-reinforced vs. cement-augmented screws), polymer-reinforced screws and control screws were placed into the left and right pedicle of seven vertebrae (mean age: 74.0 (SD 9.3) years) to allow for pairwise left-right comparisons. Each screw was subjected to cyclic cranio-caudal loading with an initial load ranging from -50 N to +50 N and with stepwise increasing compressive loads (5 N every 100 cycles) until screw loosening. FINDINGS: Polymer-reinforced pedicle screws resisted a higher number of load cycles until loosening than the contralateral non-augmented control screws (4300 SD 2018 vs. 2457 SD 1116 load cycles, p = 0.015). Screw anchorage of polymer-reinforced pedicle screws was comparable to that of cement augmented control screws (3857 (SD2085) vs. 4300 (SD1257) load cycles until failure, p = 0.64). INTERPRETATION: Our findings indicate that polymer-reinforcement significantly enhances pedicle screw anchorage in low quality bone and that its effect is similar in size than that of cement augmentation.


Assuntos
Cimentos Ósseos , Vértebras Lombares/cirurgia , Parafusos Pediculares , Polímeros/química , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Desenho de Equipamento , Feminino , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Movimento (Física) , Polimetil Metacrilato/química , Risco , Ultrassonografia
13.
Int Orthop ; 43(9): 2175-2181, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30306219

RESUMO

PURPOSE: To investigate if the stability of minimally invasive screw osteosynthesis of displaced intra-articular calcaneal fractures (DIACF) can be effectively increased by an innovative approach to screw tip augmentation. METHODS: In eight-paired human cadaver hindfoot specimens, DIACF of Sanders type IIB were treated with either standard screw osteosynthesis or with bone cement augmentation of the screw tips in the main fragments. The instrumented specimens were subjected to a cyclic loading protocol (9000 cycles, with stepwise increasing loads, 100-1000 N). The interfragment motions were quantified as tuber fragment tilt (TFT) and posterior facet inclination angle (PFIA) using a 3-D motion analysis system. Böhler's angle (BA) was evaluated from X-rays. A load-to-failure test was performed after the cyclic loading protocol. RESULTS: All but one specimen of the augmented group withstood more cycles than the respective specimens of the non-augmented group. Mean cycles to failure for the failure criterion of 5° TFT were 7299 ± 1876 vs. 3864 ± 1810, corresponding to loads of 811 N ± 195 vs. 481 N ± 180, (P = 0.043). There were no significant differences observed in the PFIAs. The failure criterion of 5° BA was reached after a mean of 7929 cycles ± 2004 in the augmented group and 4129 cycles ± 2178 in the non-augmented group, corresponding to loads of 893 N ± 200 vs. 513 N ± 218, (P = 0,090). The mean load-to-failure of the four specimens in the augmented group that completed the cyclic loading was 1969 N over a 1742-2483 N range. CONCLUSION: Screw tip augmentation significantly improved the mechanical stability of the calcanei after osteosynthesis in terms of decreased tuber fragment tilts and less changes in Böhler's angle.


Assuntos
Parafusos Ósseos , Calcâneo/cirurgia , Fixação Interna de Fraturas/instrumentação , Fraturas Intra-Articulares/cirurgia , Idoso , Fenômenos Biomecânicos , Cadáver , Calcâneo/lesões , Calcâneo/fisiopatologia , Feminino , Fixação Interna de Fraturas/métodos , Humanos , Fraturas Intra-Articulares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos
14.
Biomed Tech (Berl) ; 63(6): 709-717, 2018 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-29040061

RESUMO

A novel biomechanical test bench has been developed for in-vitro evaluation of the knee joint. The test bench allows the kinematics of the knee joint to be studied in all six degrees of freedom. Flexion-extension knee movements are induced by quadriceps and hamstring muscle forces simulated by five pneumatic cylinders. The kinematics of the knee and the actively applied muscle forces are measured simultaneously. The aim of this study was to validate the sensitivity and reproducibility of this novel test bench. Four fresh frozen human knees were tested three times, each with seven flexion-extension cycles between 5° and 60°. After the native knees had been tested, the posterior cruciate ligament and then the lateral collateral ligament were dissected. The injured knees were tested in identical conditions [3×(7×5°-60°)] in order to evaluate whether the test bench is capable of detecting differences in knee kinematics between a native state and an injured one. With regard to reproducibility, the novel test bench showed almost perfect agreement for each specimen and for all states and flexion angles. In comparison with the native knees, the injured knees showed significant differences in knee kinematics. This validated novel test bench will make it possible to investigate various knee pathologies, as well as current and newly developed treatment options.


Assuntos
Articulação do Joelho/patologia , Amplitude de Movimento Articular/fisiologia , Suporte de Carga/fisiologia , Humanos , Reprodutibilidade dos Testes
15.
J Plast Reconstr Aesthet Surg ; 70(9): 1171-1180, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28712884

RESUMO

BACKGROUND: Recent findings on the pathogenesis of frontal migraine headache support, besides a central vasogenic cause, an alternative peripheral mechanism involving compressed craniofacial nerves. This is further supported by the efficiency of botulinum toxin injections as a new treatment option in frontal migraine headache patients. METHODS: The supraorbital regions of 22 alcohol-glycerine-embalmed facial halves of both sexes were dissected. Both the supratrochlear and supraorbital nerves (STN and SON, respectively) were identified, and their relationship with the corrugator supercilii muscle (CSM) was investigated by dissection and ultrasound. The course of both nerves was defined, and the interaction between the supraorbital artery (SOA) and SON was determined. RESULTS: We discovered a new possible compression point of the STN passing through the orbital septum and verified previously described compression points of both STN and SON. Osteofibrous channels used by the STN and SON were found constantly. We described the varying topography of the STN and CSM, the SON and CSM, and the SON and SOA. Further, we provide an algorithm for the ultrasound visualization of the supraorbital neurovascular bundle. CONCLUSION: Our data support the hypothesis of a peripheral mechanism for frontal migraine headache because of following potential irritation points: first, the CSM is constantly perforated by the SON and frequently by the STN; second, the topographic proximity between SOA and SON and the osteofibrous channels is used by the SON and STN; and third, the STN passes through the orbital septum.


Assuntos
Face/irrigação sanguínea , Face/inervação , Músculos Faciais/anatomia & histologia , Nervo Troclear/anatomia & histologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artérias , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transtornos de Enxaqueca/etiologia , Órbita
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA