Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 25(1): 271, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589829

RESUMO

BACKGROUND: Single limb support phase of the gait-cycle in patients who are treated for a pertrochanteric fracture is characterized by transversal loads acting on the lag screw, tending to block its dynamization. If the simultaneous axial force overcomes transversal loads of the sliding screw, the dynamization can still occur. METHODS: Biomechanical investigation was performed for three types of dynamic implants: Gamma Nail, and two types of Selfdynamizable Internal Fixators (SIF) - SIF-7 (containing two 7 mm non-cannulated sliding screws), and SIF-10 (containing one 10 mm cannulated sliding screw). Contact surface between the stem and the sliding screws is larger in SIF implants than in Gamma Nail, as the stem of Gamma Nail is hollow. A special testing device was designed for this study to provide simultaneous application of a controlled sliding screws bending moment and a controlled transversal load on sliding screws (Qt) without using of weights. Using each of the implants, axial forces required to initiate sliding screws dynamization (Qa) were applied and measured using a tensile testing machine, for several values of sliding screws bending moment. Standard least-squares method was used to present the results through the linear regression model. RESULTS: Positive correlation between Qt and Qa was confirmed (p < 0.05). While performing higher bending moments in all the tested implants, Qa was higher than it could be provided by the body weight. It was the highest in Gamma Nail, and the lowest in SIF-10. CONCLUSIONS: A larger contact surface between a sliding screw and stem results in lower forces required to initiate dynamization of a sliding screw. Patients treated for a pertrochanteric fracture by a sliding screw internal fixation who have longer femoral neck or higher body weight could have different programme of early postoperative rehabilitation than lighter patients or patients with shorter femoral neck.


Assuntos
Parafusos Ósseos , Fraturas do Fêmur , Humanos , Parafusos Ósseos/efeitos adversos , Fenômenos Biomecânicos , Fixadores Internos , Fixação Interna de Fraturas , Fraturas do Fêmur/etiologia , Peso Corporal
2.
Acta Chir Iugosl ; 60(2): 59-64, 2013.
Artigo em Sérvio | MEDLINE | ID: mdl-24298740

RESUMO

Proper timing and surgical method in management of femur fractures in polytrauma patients can greatly reduce the mortality, morbidity and disability. The aim of this paper is to present the treatment of bilateral femoral fractures in polytrauma patient with dominant chest trauma by selfdynamisable internal fixator Mitkovic (SIF) as a definitive method of fractures treatment. A 23 years old female was injured in a traffic accident. After resuscitation and treatment of the dominant chest injuries, surgical treatment of bilateral femur fractures performed on the fourth day after the injury. Length of surgery was 65 minutes. There was not blood substitution during the intervention and blood loss through the operative wounds drainage. There was no worsening of the pulmonary function after orthopaedic surgery. The patient discharged from hospital postoperative day ten. Postoperative follow-up was 9 months. The fractures healed with an excellent functional result. Application of selfdynamisable internal fixator (SIF) with minimally invasive technique for the treatment of bilateral femoral fractures in polytrauma patients is a good operative method because poses minimally additional operative trauma and provides excellent biomechanical conditions for fracture healing.


Assuntos
Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Fixadores Internos , Traumatismo Múltiplo/cirurgia , Feminino , Fixação Interna de Fraturas/métodos , Consolidação da Fratura , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Traumatismos Torácicos/terapia , Adulto Jovem
3.
Clin Orthop Surg ; 2(4): 227-31, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21119939

RESUMO

BACKGROUND: Surgical treatment is the preferred method for treating subtrochanteric femoral fractures and the variety of extramedullary and intramedullary implants continues to evolve. The purpose of our study was to retrospectively evaluate the clinical and radiological results of subtrochanteric fractures that are treated with the Selfdynamisable internal fixator. METHODS: From January 2000 to January 2004, we treated 49 consecutive patients who had subtrochanteric fractures. According to the AO classification, 8 (16.3%) fractures were type 32-A, 16 (32.7%) were type 32-B and 25 (51%) fractures were type 32-C. The mean follow-up time was 22.3 months. RESULTS: The average operating time was 45 minutes (range, 32 to 90 minutes). The average blood loss was 250 mL (range, 125 to 350 mL). The average hospital stay was 10 days (range, 7 to 59 days). Implant failure was not observed and union was achieved in all the patients. Deep infection occurred in one (2%) patient in the early postoperative period. Fracture union was achieved at a mean of 14 weeks. Varus malalignment less then 10 degree was noted in three (6.1%) patients at the end of follow-up. Thirty-five patients were pain-free and 14 had mild pain. CONCLUSIONS: The selfdynamisable internal fixator was successfully used for subtrochanteric fracture. It provides a short operative time, low blood loss, spontaneous biaxial dynamisation and healing in an optimal period of time without the need for secondary intervention.


Assuntos
Fixação Interna de Fraturas/instrumentação , Fraturas do Quadril/cirurgia , Fixadores Internos , Adulto , Idoso , Idoso de 80 Anos ou mais , Terapia por Exercício , Feminino , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA