Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Vis Exp ; (206)2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38682921

RESUMO

Electromyography (EMG) is a valuable diagnostic tool for detecting neuromuscular abnormalities. Implantable epimysial electrodes are commonly used to measure EMG signals in preclinical models. Although classical resources exist describing the principles of epimysial electrode fabrication, there is a sparsity of illustrative information translating electrode theory to practice. To remedy this, we provide an updated, easy-to-follow guide on fabricating and testing a low-cost epimysial electrode. Electrodes were made by folding and inserting two platinum-iridium foils into a precut silicone base to form the contact surfaces. Next, coated stainless steel wires were welded to each contact surface to form the electrode leads. Lastly, a silicone mixture was used to seal the electrode. Ex vivo testing was conducted to compare our custom-fabricated electrode to an industry standard electrode in a saline bath, where high levels of signal agreement (sine [intraclass correlation - ICC= 0.993], square [ICC = 0.995], triangle [ICC = 0.958]), and temporal-synchrony (sine [r = 0.987], square [r = 0.990], triangle [r= 0.931]) were found across all waveforms. Low levels of electrode impedance were also quantified via electrochemical impedance spectroscopy. An in vivo performance assessment was also conducted where the vastus lateralis muscle of a rat was surgically instrumented with the custom-fabricated electrode and signaling was acquired during uphill and downhill walking. As expected, peak EMG activity was significantly lower during downhill walking (0.008 ± 0.005 mV) than uphill (0.031 ± 0.180 mV, p = 0.005), supporting the validity of the device. The reliability and biocompatibility of the device were also supported by consistent signaling during level walking at 14 days and 56 days post implantation (0.01 ± 0.007 mV, 0.012 ± 0.007 mV respectively; p > 0.05) and the absence of histological inflammation. Collectively, we provide an updated workflow for the fabrication and testing of low-cost epimysial electrodes.


Assuntos
Eletrodos Implantados , Eletromiografia , Eletromiografia/métodos , Eletromiografia/instrumentação , Animais , Ratos , Fluxo de Trabalho , Músculo Esquelético/fisiologia , Desenho de Equipamento , Eletrodos
2.
Exerc Sport Sci Rev ; 51(3): 109-116, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37093645

RESUMO

Lengthening contractions (i.e., eccentric contractions) are capable of uniquely triggering the nervous system and signaling pathways to promote tissue health/growth. This mode of exercise may be particularly potent for patients suffering from muscle weakness after joint injury. Here we provide a novel framework for eccentric exercise as a safe, effective mode of exercise prescription for muscle recovery.


Assuntos
Exercício Físico , Contração Muscular , Humanos , Exercício Físico/fisiologia , Contração Muscular/fisiologia , Debilidade Muscular , Terapia por Exercício , Transdução de Sinais , Músculo Esquelético/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA