Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
1.
Biomed Phys Eng Express ; 9(3)2023 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-36626819

RESUMO

Although applying machine learning (ML) algorithms to rupture status assessment of intracranial aneurysms (IA) has yielded promising results, the opaqueness of some ML methods has limited their clinical translation. We presented the first explainability comparison of six commonly used ML algorithms: multivariate logistic regression (LR), support vector machine (SVM), random forest (RF), extreme gradient boosting (XGBoost), multi-layer perceptron neural network (MLPNN), and Bayesian additive regression trees (BART). A total of 112 IAs with known rupture status were selected for this study. The ML-based classification used two anatomical features, nine hemodynamic parameters, and thirteen morphologic variables. We utilized permutation feature importance, local interpretable model-agnostic explanations (LIME), and SHapley Additive exPlanations (SHAP) algorithms to explain and analyze 6 Ml algorithms. All models performed comparably: LR area under the curve (AUC) was 0.71; SVM AUC was 0.76; RF AUC was 0.73; XGBoost AUC was 0.78; MLPNN AUC was 0.73; BART AUC was 0.73. Our interpretability analysis demonstrated consistent results across all the methods; i.e., the utility of the top 12 features was broadly consistent. Furthermore, contributions of 9 important features (aneurysm area, aneurysm location, aneurysm type, wall shear stress maximum during systole, ostium area, the size ratio between aneurysm width, (parent) vessel diameter, one standard deviation among time-averaged low shear area, and one standard deviation of temporally averaged low shear area less than 0.4 Pa) were nearly the same. This research suggested that ML classifiers can provide explainable predictions consistent with general domain knowledge concerning IA rupture. With the improved understanding of ML algorithms, clinicians' trust in ML algorithms will be enhanced, accelerating their clinical translation.


Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico , Teorema de Bayes , Redes Neurais de Computação , Algoritmos , Aprendizado de Máquina
2.
AJNR Am J Neuroradiol ; 42(2): 214-220, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33243899

RESUMO

Originally described by Davis et al in 2013, 4D-Digital Subtraction Angiography (4D-DSA) has developed into a commercially available application of DSA in the angiography suite. 4D-DSA provides the user with 3D time-resolved images, allowing observation of a contrast bolus at any desired viewing angle through the vasculature and at any time point during the acquisition (any view at any time). 4D-DSA mitigates some limitations that are intrinsic to both 2D- and 3D-DSA images. The clinical applications for 4D-DSA include evaluations of AVMs and AVFs, intracranial aneurysms, and atherosclerotic occlusive disease. Recent advances in blood flow quantification using 4D-DSA indicate that these data provide both the velocity and geometric information necessary for the quantification of blood flow. In this review, we will discuss the development, acquisition, reconstruction, and current neurovascular applications of 4D-DSA volumes.


Assuntos
Angiografia Digital/métodos , Encefalopatias/diagnóstico por imagem , Imageamento Tridimensional/métodos , Neuroimagem/métodos , Feminino , Humanos , Masculino
3.
AJNR Am J Neuroradiol ; 40(12): 2124-2129, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31672837

RESUMO

BACKGROUND AND PURPOSE: Quantification of blood flow using a 4D-DSA would be useful in the diagnosis and treatment of cerebrovascular diseases. A protocol optimizing identification of density variations in the time-density curves of a 4D-DSA has not been defined. Our purpose was to determine the contrast injection protocol most likely to result in the optimal pulsatility signal strength. MATERIALS AND METHODS: Two 3D-printed patient-specific models were used and connected to a pulsatile pump and flow system, which delivered 250-260 mL/min to the model. Contrast medium (Isovue, 370 mg I/mL, 75% dilution) was injected through a 6F catheter positioned upstream from the inlet of the model. 4D-DSA acquisitions were performed for the following injection rates: 1.5, 2.0, 2.5, 3.0 and 3.5 mL/s for 8 seconds. To determine pulsatility, we analyzed the time-density curve at the inlets using the oscillation amplitude and a previously described numeric metric, the sideband ratio. Vascular geometry from 4D-DSA reconstructions was compared with ground truth and micro-CT measurements of the model. Dimensionless numbers that characterize hemodynamics, Reynolds and Craya-Curtet, were calculated for each injection rate. RESULTS: The strongest pulsatility signal occurred with the 2.5 mL/s injections. The largest oscillation amplitudes were found with 2.0- and 2.5-mL/s injections. Geometric accuracy was best preserved with injection rates of >1.5 mL/s. CONCLUSIONS: An injection rate of 2.5 mL/s provided the strongest pulsatility signal in the 4D-DSA time-density curve. Geometric accuracy was best preserved with injection rates above 1.5 mL/s. These results may be useful in future in vivo studies of blood flow quantification.


Assuntos
Algoritmos , Angiografia Digital/métodos , Hemodinâmica/fisiologia , Modelos Cardiovasculares , Neuroimagem/métodos , Transtornos Cerebrovasculares/diagnóstico por imagem , Meios de Contraste , Humanos
4.
AJNR Am J Neuroradiol ; 39(10): 1871-1877, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30213811

RESUMO

BACKGROUND AND PURPOSE: 4D-DSA provides time-resolved 3D-DSA volumes with high temporal and spatial resolutions. The purpose of this study is to investigate a shifted least squares method to estimate the blood velocity from the 4D DSA images. Quantitative validation was performed using a flow phantom with an ultrasonic flow probe as ground truth. Quantification of blood velocity in human internal carotid arteries was compared with measurements generated from 3D phase-contrast MR imaging. MATERIALS AND METHODS: The centerlines of selected vascular segments and the time concentration curves of each voxel along the centerlines were determined from the 4D-DSA dataset. The temporal shift required to achieve a minimum difference between any point and other points along the centerline of a segment was calculated. The temporal shift as a function of centerline point position was fit to a straight line to generate the velocity. The proposed shifted least-squares method was first validated using a flow phantom study. Blood velocities were also estimated in the 14 ICAs of human subjects who had both 4D-DSA and phase-contrast MR imaging studies. Linear regression and correlation analysis were performed on both the phantom study and clinical study, respectively. RESULTS: Mean velocities of the flow phantom calculated from 4D-DSA matched very well with ultrasonic flow probe measurements with 11% relative root mean square error. Mean blood velocities of ICAs calculated from 4D-DSA correlated well with phase-contrast MR imaging measurements with Pearson correlation coefficient r = 0.835. CONCLUSIONS: The availability of 4D-DSA provides the opportunity to use the shifted least-squares method to estimate velocity in vessels within a 3D volume.


Assuntos
Angiografia Digital/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Análise dos Mínimos Quadrados , Adulto , Artéria Carótida Interna/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Masculino , Imagens de Fantasmas
5.
AJNR Am J Neuroradiol ; 36(10): 1964-70, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26066625

RESUMO

BACKGROUND AND PURPOSE: Perfusion and angiographic imaging using intravenous contrast application to evaluate stroke patients is now technically feasible by flat detector CT performed by the angiographic system. The aim of this pilot study was to show the feasibility and qualitative comparability of a novel flat detector CT dynamic perfusion and angiographic imaging protocol in comparison with a multimodal stroke MR imaging protocol. MATERIALS AND METHODS: In 12 patients with acute stroke, MR imaging and the novel flat detector CT protocol were performed before endovascular treatment. Perfusion parameter maps (MTT, TTP, CBV, CBF) and MIP/volume-rendering technique images obtained by using both modalities (MR imaging and flat detector CT) were compared. RESULTS: Comparison of MIP/volume-rendering technique images demonstrated equivalent visibility of the occlusion site. Qualitative comparison of perfusion parameter maps by using ASPECTS revealed high Pearson correlation coefficients for parameters CBF, MTT, and TTP (0.95-0.98), while for CBV, the coefficient was lower (0.49). CONCLUSIONS: We have shown the feasibility of a novel dynamic flat detector CT perfusion and angiographic protocol for the diagnosis and triage of patients with acute ischemic stroke. In a qualitative comparison, the parameter maps and MIP/volume-rendering technique images compared well with MR imaging. In our opinion, this flat detector CT application may substitute for multisection CT imaging in selected patients with acute stroke so that in the future, patients with acute stroke may be directly referred to the angiography suite, thereby avoiding transportation and saving time.


Assuntos
Angiografia Cerebral/instrumentação , Angiografia Cerebral/métodos , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Imagem de Perfusão/instrumentação , Imagem de Perfusão/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/instrumentação , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Sensibilidade e Especificidade
6.
Clin Neuroradiol ; 24(1): 43-9, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23712863

RESUMO

INTRODUCTION: Improvements in the imaging capabilities of angiographic C-arm computed tomography (CT) using flat detector angiographic (FD-CT) systems now provide a means for the in vivo visualization of devices used for the treatment of intracranial aneurysms. One such device, the WEB embolization device, is made of a braided mesh of nitinol wires, the size of which are near to the limits of visualization using conventional x-ray fluoroscopy. Our hypothesis was that the imaging of these implants C-arm CT would provide useful information regarding their positioning and deployment. METHODS: In five New Zealand white rabbits elastase induced aneurysms were created and subsequently treated using a WEB. Imaging was performed using digital subtraction angiography (DSA), X-ray imaging and two different Angiographic C-arm CT protocols. The images were evaluated by two neuroradiologists using an evaluation scale. RESULTS: The mesh of the WEB was barely visible on the DSA or x-ray fluoroscopy images. Volume rendering technique (VRT) reconstruction and multiplanar reconstruction (MPR) of images done using the C-arm CT protocols clearly delineated the shape and structure of the device. Contrast-enhanced MPR and VRT reconstructions allowed assessment of the status of blood flow in the aneurysms. Beam hardening artifacts caused by platinum markers on the WEB were present. CONCLUSION: In vivo C-arm CT imaging of the WEB is feasible and allows precise determination of the position and deployment status of the device. On contrast-enhanced images the occlusion status of aneurysms and the positioning of the WEB in relationship to the parent artery can be evaluated. C-arm-CT may serve as a minimal-invasive follow-up imaging modality.


Assuntos
Angiografia Cerebral/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Trombólise Mecânica/instrumentação , Radiografia Intervencionista/métodos , Telas Cirúrgicas , Tomografia Computadorizada por Raios X/métodos , Animais , Análise de Falha de Equipamento , Aneurisma Intracraniano/induzido quimicamente , Trombólise Mecânica/métodos , Elastase Pancreática , Desenho de Prótese , Coelhos , Resultado do Tratamento
7.
Clin Neuroradiol ; 23(4): 285-92, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23525670

RESUMO

BACKGROUND: Temporary balloon test occlusion (BTO) might be performed prior to procedures in which occlusion of the internal carotid artery (ICA) might be necessary. We tested the hypothesis that parametric color coding (PCC) of angiographic series (digital subtraction angiography (DSA)) along with the assessment of cerebral blood volume (CBV) in the angiography suite would simplify and enhance the identification of candidates who are most likely to tolerate occlusion. MATERIALS AND METHODS: Fifteen patients underwent angiographic series (DSA) and perfusion imaging before and during BTO. Pre- and postocclusion DSA acquisitions were evaluated for venous delay by conventional methods ("eye balling") and by PCC measurements. Comparison of CBV values between the left and right hemisphere in 6 defined regions was performed. RESULTS: Values of venous delay by eye balling and PCC showed a high correlation (r = 0.87, p < 0.01). Bland-Altman plot indicated slightly lower values (-0.05 s) by the PCC method. One of the 15 patients developed an asymmetrical CBV map with an increase in CBV of more than one standard deviation in 3 of the 6 regions of interest (ROIs). Acquisition of angiographic series and perfusion imaging did not prolong the test occlusion time. CONCLUSION: PCC and CBV mapping are feasible during BTO. The use of PCC seems to simplify the ability to measure changes in venous filling delay. Perfusion imaging may show an increase in CBV in patients reaching the limits of cerebral autoregulation. These patients may be at risk for delayed infarction, even though they seem to tolerate temporary occlusion, and could be unsuitable candidates for permanent ICA occlusion.


Assuntos
Angiografia Digital/métodos , Oclusão com Balão/métodos , Artéria Carótida Interna/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/terapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Intervencionista/métodos , Angiografia Cerebral/métodos , Cor , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
AJNR Am J Neuroradiol ; 33(9): 1696-701, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22627802

RESUMO

BACKGROUND AND PURPOSE: Measurement of perfusion parameters is typically done using an intravenous injection of contrast medium. This purpose of this study was to evaluate the feasibility of measuring regional and global CBV using C-arm CT with IA injections of contrast medium. MATERIALS AND METHODS: Twelve canines were studied. CBV measurement was performed using standard PCT, and then using C-arm CT with IV and IA contrast. Values obtained using C-arm CT were compared with those using PCT. RESULTS: C-arm CT CBV maps using IA injections required less contrast than ones with IV injections. PCT and C-arm CT using IV and AA injections provided comparable maps. In controls, C-arm CT with a CCA or VA injection provided comparable maps to PCT. In animals with a stroke, a CCA or VA injection did not provide maps comparable to ones made with PCT. IV and AA C-arm CT showed excellent quantitative agreement with PCT, while CCA and VA C-arm CT studies did not. CONCLUSIONS: Measurement of global CBV using C-arm CT in conjunction with either an IV or an AA injection was feasible in controls and dogs with a stroke. Measurement of regional CBV with C-arm CT using either CCA or VA injection, in normal canines, provided CBV maps qualitatively comparable with those obtained with PCT; the absolute CBV values from these maps were in poor agreement with PCT measurements. Valid measurement of CBV using C-arm CT requires all tissue in a target region to be fully and equally opacified during any acquisition. Using CCA or VA injections, it was impossible to document if and when this had been achieved. CBV measurements using these routes of injection were therefore not reliable.


Assuntos
Determinação do Volume Sanguíneo/métodos , Volume Sanguíneo/fisiologia , Isquemia Encefálica/fisiopatologia , Artérias Cerebrais/fisiologia , Circulação Cerebrovascular/fisiologia , Imagem de Perfusão/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Isquemia Encefálica/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Cães , Injeções Intra-Arteriais , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
AJNR Am J Neuroradiol ; 33(3): 507-12, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22194362

RESUMO

BACKGROUND AND PURPOSE: To our knowledge, no reproducible animal model of a giant bifurcation type aneurysm has been described. It was our aim to develop a 1-stage and reproducible model of a venous pouch giant aneurysm in canines. MATERIALS AND METHODS: Nine canines were involved. Bilateral CCAs were exposed. The left CCA was divided and its distal segment was swung to the right side. Using the right CCA and the distal segment of the left CCA, either a bifurcation or a terminal arterial structure was constructed. Bilateral external jugular veins were also exposed. A 30-mm vein segment was harvested from each side. Each vein graft was split and unfolded to make 2 venous sheets. These sheets were then joined top-to-bottom so as to form a single cylinder in such a way that original adventitial side of the venous sheets was on the exterior surface. In 2 instances, pieces of polytetrafluoroethylene were employed along with the venous sheets. The combined vein graft was then incorporated into the arterial anastomosis. Lastly, the top of the venous pouch was closed. No medications for anticoagulant or antiplatelet were used throughout the study period. Follow-up imaging studies were performed. RESULTS: It took 2.5 hours on average for 2 operators to create an aneurysm. Eight of the 9 aneurysms were patent at follow-up. The cause of the spontaneous thrombosis was unclear despite autopsy. All the aneurysms had a maximum diameter >20 mm. CONCLUSIONS: We demonstrated and illustrated a 1-stage and reproducible procedure to create a model of a venous pouch bifurcation giant aneurysm in canines.


Assuntos
Modelos Animais de Doenças , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/fisiopatologia , Animais , Circulação Cerebrovascular , Cães , Estudos de Viabilidade , Humanos , Radiografia
11.
AJNR Am J Neuroradiol ; 33(4): 618-25, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22207301

RESUMO

BACKGROUND AND PURPOSE: A new FPCT application offers the possibility of perfusion (FPCT CBV) and parenchymal (FPCT) imaging within the angiography suite. We tested the hypothesis that findings in FPCT CBV and FPCT would correlate with those obtained using MSCT and PCT. MATERIALS AND METHODS: In 16 patients with acute MCA occlusion, FPCT CBV was performed immediately posttreatment. The volume of tissue having abnormal CBV values was determined by FPCT CBV and PCT images. Stroke volume on follow-up MSCT was determined, CBV values in the effected parenchyma were measured, and FPCT images were reviewed. RESULTS: In 6 cases, we found a FPCT CBV value identical or higher (hyperemia) in comparison with the contralateral side. In 10 cases, we found CBV lesions with values lower (oligemia) than the contralateral brain tissue. We found a high correlation of CBV lesion volume on FPCT CBV images to stroke volume on follow-up MSCT (r = 0.9, P < .05) in the oligemia group. Absolute FPCT CBV and PCT CBV values were comparable and showed good correlation (r = 0.9, P < .05). In 8 patients, contrast medium extravasation was visible. CONCLUSIONS: The new FPCT application allows assessment of CBV in acute stroke patients. Our initial results indicate that these measurements may predict final infarct volume. The ability to assess this key parameter of cerebral perfusion within the angiographic suite may improve the management of these patients.


Assuntos
Determinação do Volume Sanguíneo/instrumentação , Angiografia Cerebral/instrumentação , Circulação Cerebrovascular , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/fisiopatologia , Tomografia Computadorizada por Raios X/instrumentação , Idoso , Velocidade do Fluxo Sanguíneo , Determinação do Volume Sanguíneo/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Aneurisma Intracraniano/cirurgia , Masculino , Projetos Piloto , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
12.
AJNR Am J Neuroradiol ; 32(7): 1216-20, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21700791

RESUMO

BACKGROUND AND PURPOSE: There is no satisfactory parameter that can predict the need for assistant devices for endovascular aneurysm coiling. Our aim was to evaluate the utility of MOA as a predictor of the need for stent-assisted coiling in ICA sidewall aneurysms. MATERIALS AND METHODS: From a retrospective review of an internal data base, 55 consecutive ICA sidewall aneurysms were identified. Thirty-two of the aneurysms were treated by using endovascular techniques. Because 23 of the 55 aneurysms were either untreated or clipped, 3 experienced interventionalists reviewed the 3D images of these aneurysms and then made a decision as to whether stent-assisted coiling would have been required. Thirty-one of the 55 aneurysms would have required stent-assisted coiling, while 24 would not. Neck width, DNR, AR, and MOA were obtained from each aneurysm by using prototype software. These parameters were then correlated with the requirement of stent-assisted coiling. RESULTS: MOA and neck width of aneurysms requiring stent-assisted coiling were significantly larger than those not requiring stent-assisted coiling (P < .001 and <0.001, respectively). Although the DNR and AR of aneurysms requiring stent-assisted coiling were smaller than those not requiring it, the difference was not significant (P = .22 and 0.12, respectively). ROC analysis revealed that MOA was the parameter that best correlated with the need for stent-assisted coiling. Inclusion of MOA with the rest of the parameters significantly increased the predictive performance regarding the need for stent-assisted coiling (P = .005). CONCLUSIONS: In this small study, MOA was a useful parameter to predict the need for stent-assisted coiling in ICA sidewall aneurysms. Further prospective study of this parameter for aneurysms at multiple locations is required to determine its ultimate value.


Assuntos
Dissecação da Artéria Carótida Interna/diagnóstico por imagem , Dissecação da Artéria Carótida Interna/terapia , Embolização Terapêutica/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Stents , Adulto , Idoso , Artéria Carótida Interna/diagnóstico por imagem , Angiografia Cerebral , Estudos de Coortes , Bases de Dados Factuais , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos
13.
AJNR Am J Neuroradiol ; 31(8): 1508-11, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20488903

RESUMO

BACKGROUND AND PURPOSE: Imaging is a key element in the study of many rodent models of human diseases. The application of DSA has been limited in these studies in part because of a lack of a method that allows serial intra-arterial examinations to be performed during an extended period of time. It was our intent to develop and test a method for performing sequential arterial catheterizations and DSA in rats. MATERIALS AND METHODS: Using a transfemoral approach, we subjected 12 adult male Harvey rats to 3 sequential DSA examinations during a 6- to 8-week period. At each examination, 2 selective arterial catheterizations and a DSA were performed. Animals were monitored for ill effects, and images from the 3 examinations were compared for quality and the presence of any arterial injury. RESULTS: Ten of the 12 rats survived all 3 examinations. There were no adverse effects noted and no evidence of arterial injury from the examinations. CONCLUSIONS: With the technique described, it is possible to perform serial arterial catheterizations and DSA in rats. This technique will be useful as an adjunct in the use of rodents for the study of human diseases.


Assuntos
Angiografia Digital/métodos , Cateterismo/métodos , Angiografia Cerebral/métodos , Angiografia Digital/mortalidade , Animais , Cateterismo/mortalidade , Angiografia Cerebral/mortalidade , Circulação Cerebrovascular , Modelos Animais de Doenças , Artéria Femoral , Masculino , Morbidade , Ratos , Ratos Endogâmicos , Roedores
14.
AJNR Am J Neuroradiol ; 31(8): 1462-9, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20378700

RESUMO

BACKGROUND AND PURPOSE: The viability of both brain parenchyma and vascular anatomy is important in estimating the risk and potential benefit of revascularization in patients with acute cerebral ischemia. We tested the hypothesis that when used in conjunction with IV contrast, FD-CT imaging would provide both anatomic and physiologic information that would correlate well with that obtained by using standard multisection CT techniques. MATERIALS AND METHODS: Imaging of brain parenchyma (FD-CT), cerebral vasculature (FD-CTA), and cerebral blood volume (FD-CBV) was performed in 10 patients. All patients also underwent conventional multisection CT, CTA, CTP (including CBV, CTP-CBV), and conventional catheter angiography. Correlation of the corresponding images was performed by 2 experienced neuroradiologists. RESULTS: There was good correlation of the CBV color maps and absolute values between FD-CBV and CTP-CBV (correlation coefficient, 0.72; P < .001). The Bland-Altman test showed a mean difference of CBV values between FD-CT and CTP-CBV of 0.04 ± 0.55 mL/100 mL. All vascular lesions identified with standard CTA were also visualized with FD-CTA. Visualization of brain parenchyma by using FD-CT was poor compared with that obtained by using standard CT. CONCLUSIONS: Both imaging of the cerebral vasculature and measurements of CBV by using FD-CT are feasible. The resulting vascular images and CBV measurements compared well with ones made by using standard CT techniques. The ability to measure CBV and also visualize cerebral vasculature in the angiography suite may offer significant advantages in the management of patients. FD-CT is not yet equivalent to CT for imaging of brain parenchyma.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Angiografia Cerebral/métodos , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Volume Sanguíneo , Circulação Cerebrovascular , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos
15.
AJNR Am J Neuroradiol ; 31(5): 919-24, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20167651

RESUMO

BACKGROUND AND PURPOSE: Color has been shown to facilitate both visual search and recognition tasks. It was our purpose to examine the impact of a color-coding algorithm on the interpretation of 2D-DSA acquisitions by experienced and inexperienced observers. MATERIALS AND METHODS: Twenty-six 2D-DSA acquisitions obtained as part of routine clinical care from subjects with a variety of cerebrovascular disease processes were selected from an internal data base so as to include a variety of disease states (aneurysms, AVMs, fistulas, stenosis, occlusions, dissections, and tumors). Three experienced and 3 less experienced observers were each shown the acquisitions on a prerelease version of a commercially available double-monitor workstation (XWP, Siemens Healthcare). Acquisitions were presented first as a subtracted image series and then as a single composite color-coded image of the entire acquisition. Observers were then asked a series of questions designed to assess the value of the color-coded images for the following purposes: 1) to enhance their ability to make a diagnosis, 2) to have confidence in their diagnosis, 3) to plan a treatment, and 4) to judge the effect of a treatment. The results were analyzed by using 1-sample Wilcoxon tests. RESULTS: Color-coded images enhanced the ease of evaluating treatment success in >40% of cases (P < .0001). They also had a statistically significant impact on treatment planning, making planning easier in >20% of the cases (P = .0069). In >20% of the examples, color-coding made diagnosis and treatment planning easier for all readers (P < .0001). Color-coding also increased the confidence of diagnosis compared with the use of DSA alone (P = .056). The impact of this was greater for the naïve readers than for the expert readers. CONCLUSIONS: At no additional cost in x-ray dose or contrast medium, color-coding of DSA enhanced the conspicuity of findings on DSA images. It was particularly useful in situations in which there was a complex flow pattern and in evaluation of pre- and posttreatment acquisitions. Its full potential remains to be defined.


Assuntos
Algoritmos , Angiografia Digital/métodos , Colorimetria/métodos , Reconhecimento Automatizado de Padrão/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
AJNR Am J Neuroradiol ; 31(3): 536-40, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20053809

RESUMO

BACKGROUND AND PURPOSE: CBV is a key parameter in distinguishing penumbra from ischemic core. The purpose of this study was to compare CBV measurements acquired with standard PCT with ones obtained with C-arm CT in a canine stroke model. MATERIALS AND METHODS: Under an institutionally approved protocol, unilateral MCA strokes were created in 10 canines. Four hours later, DWI was used to confirm the presence of an infarct. CBV maps acquired with PCT were compared with ones acquired by using C-arm CT. Three experienced observers, blinded to the technique used for acquisition, evaluated the CBV maps. RESULTS: An ischemic stroke was achieved in 9 of the 10 animals. Areas of reduced CBV were detected in 70%-75% of the PCT studies and in 83%-87% of the C-arm CT examinations, with false-positives in 1.7% and 3.3%, respectively. False-negatives were found in 25% of the PCT and 12.2% of the C-arm CT studies. In all studies, there was a significant difference between the absolute CBV values in normal and abnormal tissue (P < .005) and no significant difference between PCT and C-arm CT CBV values in either the normal or the abnormal parenchyma (P > .05). CONCLUSIONS: CBV measurements made with C-arm CT compare well with ones made with PCT. While further work is required both to fully validate the technique and to define its ultimate clinical value, it appears that it offers a feasible method for assessing CBV in the angiography suite.


Assuntos
Determinação do Volume Sanguíneo/métodos , Isquemia Encefálica/diagnóstico por imagem , Circulação Cerebrovascular , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Animais , Angiografia Cerebral/métodos , Angiografia Cerebral/normas , Modelos Animais de Doenças , Cães , Reações Falso-Negativas , Reações Falso-Positivas , Tomografia Computadorizada por Raios X/normas
18.
AJNR Am J Neuroradiol ; 30(7): 1337-41, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19461063

RESUMO

BACKGROUND AND PURPOSE: Recent advances in flat panel detector angiographic equipment have provided the opportunity to obtain physiologic and anatomic information from angiographic examinations. To exploit this possibility, one must understand the factors that affect the bolus geometry of an intra-arterial injection of contrast medium. It was our purpose to examine these factors in a canine model. MATERIALS AND METHODS: Under an institutionally approved protocol conforming to Guide for the Care and Use of Laboratory Animals of the National Institutes of Health, 7 canines were placed under general anesthesia with isoflurane and propofol. Through a 5F catheter placed into the right common carotid artery, a series of biplane angiographic acquisitions was obtained to examine the effects caused by variation in the volume of injection, the rate of injection, the duration of injection, the concentration of contrast medium, and the catheter position on arterial, capillary, and venous opacification. The results of each injection protocol were determined from analysis of a time-contrast concentration curve derived from locations over an artery, in brain parenchyma, and over a vein. The curve was generated from 2D digital subtraction angiography acquisitions by using prototype software. The area under the curve, the amplitude of the curve, and the time to peak (TTP) were analyzed separately for each injection parameter. RESULTS: Changes in the injection protocols resulted in predictable changes in the time-concentration curves. The injection parameter that contributed most to maximum opacification was the volume of contrast medium injected. When the injection rate was fixed and the volume was varied, there was an increase in opacification (maximal) proportional to the injected volume. The injected volume also had an indirect (secondary) impact on the temporal characteristics of the opacification. The time-concentration curve became wider, and the peak was shifted to the right as the injection duration increased. The impact of injected volume on maximal opacification was significant (P < .0001), regardless of the site of measurement (artery, tissue, and vein); however, the impact on the temporal characteristics of the time-concentration curve reached statistical significance only in measurements made in the artery and the vein (P < .05), but not in the tissue (P > .1). The impact of injected volume on maximal opacification became nonproportional in the tissue and vein when the volume was very large (>12 mL). Increasing the concentration of contrast medium resulted in a nonproportional increase in the height of the time-concentration curves (P < .05). Injection rate had an impact on both maximal opacification and TTP. The impact on TTP occurred only when the injection rate was very slow (1 mL/s). Changes of concentration had a similar impact on the time-concentration curve. Catheter position did not cause significant alterations in the shape of the curves. CONCLUSIONS: There were predictable effects from modification of injection parameters on the contrast bolus geometry and on time-concentration curves as measured in an artery, brain parenchyma, or a vein. The amplitude, TTP, and area under the time-concentration curve depend mainly and proportionally on the amount of iodine traversing the vasculature per second. Other injection parameters were of less importance in defining bolus geometry. These findings mimic those observed in studies of parameters affecting bolus geometry following an intravenous injection.


Assuntos
Angiografia Digital/métodos , Artérias/metabolismo , Capilares/metabolismo , Angiografia Cerebral/métodos , Meios de Contraste/administração & dosagem , Meios de Contraste/farmacocinética , Veias/metabolismo , Animais , Capilares/diagnóstico por imagem , Cães , Injeções Intra-Arteriais , Taxa de Depuração Metabólica , Organização e Administração
19.
AJNR Am J Neuroradiol ; 30(5): 917-22, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19299488

RESUMO

BACKGROUND AND PURPOSE: Cerebral blood volume (CBV) is an important parameter in estimating the viability of brain tissue following an ischemic event. We tested the hypothesis that C-arm CT measurements of CBV would correlate well with those made with perfusion CT (PCT). MATERIALS AND METHODS: CBV was measured in 12 canines by using PCT and C-arm CT. Two measurements with each technique were made on each animal; a different injection protocol was used for each of these techniques. PCT was performed by using a 64-section V-scanner. C-arm CT was performed by using a biplane Artis dBA system. PCT images were transferred to a commercially available workstation for postprocessing and analysis; C-arm CT images were transferred to a commercially available workstation for postprocessing and analysis by using prototype software. From each animal, 2 sections from each technique were selected for analysis. RESULTS: There was good agreement of both the color maps and absolute numbers between the 2 techniques. The maximum and mean deviations of values between the 2 techniques for the first 5 animals were 30.20% and 7.82%; for the second 7 animals, these values were 26.79% and 7.40%. The maximum and mean deviations between the 2 C-arm CT studies performed on the first 5 animals were 33.15% and 12.24%; for the second 7 animals, these values were 41.15% and 10.89%. CONCLUSIONS: In these healthy animals, measurement of CBV with C-arm CT compared well with measurements made with PCT.


Assuntos
Determinação do Volume Sanguíneo/métodos , Encéfalo/irrigação sanguínea , Encéfalo/fisiologia , Angiografia Cerebral/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Cães
20.
AJNR Am J Neuroradiol ; 29(2): 265-8, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17989371

RESUMO

BACKGROUND AND PURPOSE: Stenosis of the carotid artery may be a cause of reduced cognitive performance that can be ameliorated with placement of a stent. The goal of this study was to measure cognitive performance and speed of psychomotor performance prospectively before and after carotid stent placement. MATERIALS AND METHODS: Patients referred for stent placement for a unilateral carotid artery stenosis were enrolled in the study. Neuropsychologic testing was performed with a Mini-Mental State Examination, an extended mental status examination, a subjective cognitive status measure, and a psychomotor performance test for speed. The severity of the stenosis was measured on angiograms performed before stent placement. Three months after stent placement, CT angiograms were performed and the neuropsychologic testing was repeated. Differences in neuropsychologic test scores before and after stent placement were calculated and tested for significance with a Student t test. RESULTS: Seventeen patients with a single unilateral carotid stenosis of more than 50% completed the study. Stenosis of the carotid artery averaged 80% before treatment and 18% after treatment. After stenting, the scores from the extended mental status examination improved significantly. The scores from the subjective cognitive status measure also improved. No significant change was noted in the scores from the Mini-Mental State Examination or in the speed of psychomotor performance. CONCLUSION: Carotid stent placement in patients with a unilateral stenosis of the carotid artery resulted in significant improvement in cognitive test scores in this highly selected patient group. Further studies are needed to confirm these preliminary observations.


Assuntos
Prótese Vascular , Estenose das Carótidas/complicações , Estenose das Carótidas/cirurgia , Transtornos Cognitivos/etiologia , Transtornos Cognitivos/prevenção & controle , Stents , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA