Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Clin Med ; 11(21)2022 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-36362774

RESUMO

Background: As a preventive procedure, minimizing periprocedural risk is crucially important during left atrial appendage closure (LAAC). Methods: We included consecutive patients receiving LAAC at nine centres and assessed the relationship between baseline characteristics and the acute procedural outcome. Major procedural complications were defined as all complications requiring immediate invasive intervention or causing irreversible damage. Logistic regression was performed and included age and left-ventricular function. Furthermore, the association between acute complications and long-term outcomes was evaluated. Results: A total of 405 consecutive patients with a median age of 75 years (37% female) were included. 47% had a history of stroke. Median CHA2DS2-VASc score was 4 (interquartile range, 3−5) and the median HAS-BLED score was 3 (2−4). Major procedural complications occurred in 7% of cases. Low haemoglobin (OR 0.8, 95% CI 0.65−0.99 per g/dL, p = 0.040) and end-stage kidney disease (OR 13.0, CI 2.5−68.5, p = 0.002) remained significant in multivariate analysis. Anaemia (haemoglobin < 12 and < 13 g/dL in female and male patients) increased the risk of complications 2.2-fold. Conclusions: The major complication rate was low in this high-risk patient population undergoing LAAC. End-stage kidney disease and low baseline haemoglobin were independently associated with a higher major complication rate.

2.
JACC Cardiovasc Interv ; 15(13): 1366-1377, 2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35583363

RESUMO

BACKGROUND: Severe tricuspid regurgitation (TR) is frequently associated with significant morbidity and mortality; such patients are often deemed to be at high surgical risk. Heterotopic bicaval stenting is an emerging, attractive transcatheter solution for these patients. OBJECTIVES: The aim of this study was to evaluate the 30-day safety and 6-month efficacy outcomes of specifically designed bioprosthetic valves for the superior and inferior vena cava. METHODS: TRICUS EURO (Safety and Efficacy of the TricValve® Transcatheter Bicaval Valves System in the Superior and Inferior Vena Cava in Patients With Severe Tricuspid Regurgitation) is a nonblinded, nonrandomized, single-arm, multicenter, prospective trial that enrolled patients from 12 European centers between December 2019 and February 2021. High-risk individuals with severe symptomatic TR despite optimal medical therapy were included. The primary endpoint was quality-of-life (QOL) improvement measured by Kansas City Cardiomyopathy Questionnaire score and New York Heart Association (NYHA) functional class improvement at 6-month follow-up. RESULTS: Thirty-five patients (mean age 76 ± 6.8 years, 83% women) were treated using the TricValve system. All patients at baseline were in NYHA functional class III or IV. At 30 days, procedural success was 94%, with no procedural deaths or conversions to surgery. A significant increase in QOL at 6 months follow-up was observed (baseline and 6-month Kansas City Cardiomyopathy Questionnaire scores 42.01 ± 22.3 and 59.7 ± 23.6, respectively; P = 0.004), correlating with a significant improvement in NYHA functional class, with 79.4% of patients noted to be in functional class I or II at 6 months (P = 0.0006). The rates of 6-month all-cause mortality and heart failure hospitalization were 8.5% and 20%, respectively. CONCLUSIONS: The dedicated bicaval system for treating severe symptomatic TR was associated with a high procedural success rate and significant improvements in both QOL and functional classification at 6 months follow-up.


Assuntos
Cardiomiopatias , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Estudos Prospectivos , Qualidade de Vida , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
3.
J Clin Med ; 10(21)2021 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-34768430

RESUMO

Transcatheter aortic valve replacement (TAVR) offers a novel treatment option for patients with severe symptomatic aortic valve stenosis, particularly for patients who are unsuitable candidates for surgical intervention. However, high therapeutical costs, socio-economic considerations, and numerous comorbidities make it necessary to target and allocate available resources efficiently. In the present study, we aimed to identify risk factors associated with futile treatment following transfemoral (TF) and transapical (TA) TAVR. Five hundred and thirty-two consecutive patients (82 ± 9 years, female 63%) who underwent TAVR between June 2009 and December 2016 at the Vienna Heart Center Hietzing were retrospectively analyzed to identify predictors of futility, defined as all-cause mortality at one year following the procedure for the overall patient cohort, as well as the TF and TA cohort. Out of 532 patients, 91 (17%) did not survive the first year after TAVR. A multivariate logistic model identified cerebrovascular disease, home oxygen dependency, wheelchair dependency, periinterventional myocardial infarction, and postinterventional renal replacement therapy as the factors independently associated with an increased one-year mortality. Our findings underscore the significance of a precise preinterventional evaluation, as well as illustrating the subtle differences in baseline characteristics in the TF and TA cohort and their impact on one-year mortality.

4.
J Pers Med ; 11(11)2021 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-34834414

RESUMO

Transcatheter aortic valve replacement (TAVR) has rapidly become a viable alternative to the conventional isolated surgical aortic valve replacement (iSAVR) for treating severe symptomatic aortic stenosis. However, data on younger patients is scarce and a gap exists between data-based recommendations and the clinical use of TAVR. In our study, we utilized a machine learning (ML) driven approach to model the complex decision-making process of Heart Teams when treating young patients with severe symptomatic aortic stenosis with either TAVR or iSAVR and to identify the relevant considerations. Out of the considered factors, the variables most prominently featured in our ML model were congestive heart failure, established risk assessment scores, previous cardiac surgeries, a reduced left ventricular ejection fraction and peripheral vascular disease. Our study demonstrates a viable application of ML-based approaches for studying and understanding complex clinical decision-making processes.

5.
J Clin Med ; 10(15)2021 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-34362230

RESUMO

BACKGROUND: Younger patients with severe symptomatic aortic stenosis are a particularly challenging collective with regard to the choice of intervention. High-risk patients younger than 75 years of age are often eligible for both the transcatheter aortic valve replacement (TAVR) and the isolated surgical aortic valve replacement (iSAVR). Data on the outcomes of both interventions in this set of patients are scarce. METHODS: One hundred and forty-four propensity score-matched patients aged 75 years or less who underwent TAVR or iSAVR at the Hietzing Heart Center in Vienna, Austria, were included in the study. The mean age was 68.9 years (TAVR 68.7 vs. SAVR 67.6 years; p = 0.190) and the average EuroSCORE II was 5.4% (TAVR 4.3 [3.2%] vs. iSAVR 6.4 (4.3%); p = 0.194). RESULTS: Postprocedural adverse event data showed higher rates of newly acquired atrial fibrillation (6.9% vs. 19.4%; p = 0.049), prolonged ventilation (2.8% vs. 25.0%; p < 0.001) and multi-organ failure (0% vs. 6.9%) in the surgical cohort. The in-hospital and 30-day mortality was significantly higher for iSAVR (1.4% vs. 13.9%; p = 0.012; 12.5% vs. 2.8%; p = 0.009, respectively). The long-term survival (median follow-up 5.0 years (2.2-14.1 years)) of patients treated with the surgical approach was superior to that of patients undergoing TAVR (p < 0.001). CONCLUSION: Although the survival analysis revealed a higher in-hospital and 30-day survival rate for high-risk patients aged ≤75 years who underwent TAVR, iSAVR was associated with a significantly higher long-term survival rate.

6.
Eur J Clin Invest ; 51(9): e13589, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34120335

RESUMO

BACKGROUND: We compared the outcomes and adverse events of TAVI patients based on the discharge and long-term antiplatelet or anticoagulant treatment regimens (single antiplatelet [SAPT] vs. dual antiplatelet [DAPT] vs. anticoagulation [OAC] vs. no treatment [NT]). METHODS: The outcome of 532 consecutive patients treated with TAVI was evaluated. As the main study endpoint, the 1-year all-cause mortality was chosen to compare the different discharge treatment regimens and the 3-year all-cause mortality to compare the different long-term treatment regimens. The secondary endpoints were adverse events as defined by the Valve Academic Research Consortium-II. RESULTS: One-year survival after TAVI was highest amongst patients treated with DAPT compared to SAPT (P < .001) and OAC (P = .003), and patients under OAC demonstrated improved 1-year survival over patients treated with SAPT (P = .006). Furthermore, there was a strong trend towards improved 3-year survival for patients in the OAC cohort treated with non-vitamin K antagonists compared to vitamin K antagonists (N-VKAs vs. VKA; log-rank P = .056). CONCLUSION: The lower all-cause mortality for DAPT within the first year and N-VKAs over VKA within the first 3 years warrant considerable attention in further recommendations of antithrombotic and anticoagulation regimens after TAVI.


Assuntos
Anticoagulantes/uso terapêutico , Estenose da Valva Aórtica/cirurgia , Terapia Antiplaquetária Dupla/métodos , Inibidores do Fator Xa/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Cuidados Pós-Operatórios/métodos , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Aspirina/uso terapêutico , Áustria/epidemiologia , Clopidogrel/uso terapêutico , Feminino , Fibrinolíticos/uso terapêutico , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Masculino , Sistema de Registros , Taxa de Sobrevida , Vitamina K/antagonistas & inibidores
7.
Eur J Clin Invest ; 51(9): e13570, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33954997

RESUMO

BACKGROUND: This study aimed to evaluate the differences in outcome arising from the use of semi-compliant (SCB) versus non-compliant balloon (NCB) systems for predilatation during self-expanding transcatheter aortic valve replacement (TAVR). METHODS: 251 TAVR procedures with the implantation of self-expanding valves after predilatation were analyzed. SCB systems were used in 166 and NCB systems in 85 patients. The primary endpoint was defined as device success, a composite endpoint comprising the absence of procedural mortality, correct valve positioning, adequate valve performance and the absence of more than a mild paravalvular leak. The secondary endpoints were chosen in accordance with the valve academic research consortium (VARC-2) endpoint definitions. RESULTS: No significant differences were observed with regard to procedural device success between the SCB- and NCB cohort (SCB: 142 [85.5%%] vs. NCB: 77 [90.6%]; P = .257). There was a notable difference between the rates of conversion to open surgery and the postdilatation rate, both of which were higher for the NCB group (SCB: 1 [0.6%] vs. NCB: 4 [5.1%]; P = .042; SCB: 30 [18.1%] vs. NCB: 34 [40%]; P < .001). In a multivariate logistic regression analysis, the use of semi-compliant balloon systems for predilatation was associated with a lower risk for postdilatation (OR: 0.296; 95% CI: 0.149-0.588) and conversion to open surgery (OR: 0.205; 95% CI: 0.085-0.493; P = .001) but not for device success. CONCLUSION: While the balloon compliance did not affect the procedural mortality, device success or the rate of paravalvular leakage, the use of semi-compliant balloons for predilatation during TAVR should be investigated in larger randomized trials in the light of the lower rates of postdilatation and conversion to open surgery compared to their non-compliant counterparts.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/instrumentação , Mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Injúria Renal Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/epidemiologia , Valvuloplastia com Balão/métodos , Bloqueio de Ramo/epidemiologia , Causas de Morte , Conversão para Cirurgia Aberta/estatística & dados numéricos , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
8.
Eur J Clin Invest ; 51(6): e13491, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33432599

RESUMO

BACKGROUND: Arterial tortuosity is linked to a higher risk of adverse clinical events after transfemoral transcatheter aortic valve replacement (TF-TAVR). Currently, there are no assessment tools that can quantify this variable in three-dimensional space. This study investigated the impact of novel scoring methods of iliofemoral tortuosity on access and bleeding complications after TF-TAVR. METHODS: The main access vessel was assessed between the aortoiliacal and femoral bifurcation in preoperative multislice computed tomography scans of 240 consecutive patients undergoing TF-TAVR. Tortuosity was assessed by three methods: largest single angle, sum of all angles, and iliofemoral tortuosity (IFT) score [((true vessel length/ideal vessel length)-1)*100]. The primary study endpoint was a composite of access and bleeding complications. The secondary study endpoints were 30-day mortality and long-term survival. RESULTS: Among 240 patients, only the IFT score demonstrated a good positive correlation with the composite primary endpoint of access and bleeding complications (P = 0.031). A higher incidence of access and bleeding complications was found in patients with a higher IFT score (56 [36.8%] vs 17 [19.3%]; P = 0.003). In a multivariate logistic regression analysis, only the IFT score was a significant predictor of the primary endpoint (OR: 2.11; 95% CI: 1.09-4.05; P = 0.026). CONCLUSION: Vascular tortuosity is an underestimated risk factor during TF-TAVR. The IFT score is a valuable tool in risk stratification before TF-TAVR, predicting periprocedural access and bleeding complications.


Assuntos
Aorta/diagnóstico por imagem , Artéria Femoral/diagnóstico por imagem , Artéria Ilíaca/diagnóstico por imagem , Complicações Intraoperatórias/epidemiologia , Hemorragia Pós-Operatória/epidemiologia , Substituição da Valva Aórtica Transcateter/métodos , Lesões do Sistema Vascular/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/epidemiologia , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores
9.
J Clin Med ; 9(10)2020 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-33066034

RESUMO

BACKGROUND: Complete real-world data on the indications and outcomes of left atrial appendage closure (LAAC) outside of clinical trials are rare. In this study, we stratified patients undergoing LAAC by indication groups. METHODS: This analysis of the national multicentre Austrian LAAC Registry comprised all patients that underwent LAAC up until 2018 at the currently active centres in Austria. The baseline characteristics, procedural details and outcomes between the following indication groups were compared: bleeding as an indication for LAAC ("bleeding" group) vs. thromboembolism despite oral anticoagulation (OAC; "thromboembolism" group) vs. an intolerance to OAC for reasons other than the above ("other" group). RESULTS: The analysis included 186 patients, with 59.7% in the "bleeding" group, 8.1% in the "thromboembolism" group and 32.2% in the "other" group. The CHADS2 score was the highest in the "thromboembolism" group and the HAS-BLED score was the highest in the "bleeding" group. The procedural outcomes were similar between groups (implantation success, 97.3%), with major complications occurring in 7.0% of patients. One-year survival free from stroke, bleeding or LAAC-associated hospitalisation was 83.9%, 90.0% and 81.4% in the "bleeding", "thromboembolism" and "other" groups, respectively (p = 0.891). CONCLUSIONS: In routine clinical practice, LAAC was used in a heterogeneous patient population with atrial fibrillation (AF) and contraindication, inefficacy or intolerance to OAC. The long-term outcome was favourable in all groups.

10.
JMIR Mhealth Uhealth ; 8(10): e19227, 2020 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-33055057

RESUMO

BACKGROUND: While transcatheter aortic valve replacement (TAVR) has revolutionized the treatment of aortic valve stenosis, wearable health-monitoring devices are gradually transforming digital patient care. OBJECTIVE: The aim of this study was to develop a simple, efficient, and economical method for preprocedural frailty assessment based on parameters measured by a wearable health-monitoring device. METHODS: In this prospective study, we analyzed data of 50 consecutive patients with mean (SD) age of 77.5 (5.1) years and a median (IQR) European system for cardiac operative risk evaluation (EuroSCORE) II of 3.3 (4.1) undergoing either transfemoral or transapical TAVR between 2017 and 2018. Every patient was fitted with a wrist-worn health-monitoring device (Garmin Vivosmart 3) for 1 week prior to the procedure. Twenty different parameters were measured, and threshold levels for the 3 most predictive categories (ie, step count, heart rate, and preprocedural stress) were calculated. Patients were assigned 1 point per category for exceeding the cut-off value and were then classified into 4 stages (no, borderline, moderate, and severe frailty). Furthermore, the FItness-tracker assisted Frailty-Assessment Score (FIFA score) was compared with the scores of the preprocedural gait speed category derived from the 6-minute walk test (GSC-6MWT) and the Edmonton Frail Scale classification (EFS-C). The primary study endpoint was hospital mortality. RESULTS: The overall preprocedural stress level (P=.02), minutes of high stress per day (P=.02), minutes of rest per day (P=.045), and daily heart rate maximum (P=.048) as single parameters were the strongest predictors of hospital mortality. When comparing the different frailty scores, the FIFA score demonstrated the greatest predictive power for hospital mortality (FIFA area under the curve [AUC] 0.844, CI 0.656-1.000; P=.048; GSC-6MWT AUC 0.671, CI 0.487-0.855; P=.42; EFS-C AUC 0.636, CI 0.254-1.000; P=.44). CONCLUSIONS: This proof-of-concept study demonstrates the strong predictive performance of the FIFA score compared to that of the conventional frailty assessments.


Assuntos
Fragilidade , Substituição da Valva Aórtica Transcateter , Idoso , Fragilidade/diagnóstico , Humanos , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
11.
Eur J Clin Invest ; : e13251, 2020 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-32323303

RESUMO

BACKGROUND: We investigated the impact of an elevated plasma volume status (PVS) in patients undergoing TAVI on early clinical safety and mortality and assessed the prognostic utility of PVS for outcome prediction. MATERIALS AND METHODS: We retrospectively calculated the PVS in 652 patients undergoing TAVI between 2009 and 2018 at two centres. They were then categorized into two groups depending on their preoperative PVS (PVS ≤-4; n = 257 vs PVS>-4; n = 379). Relative PVS was derived by subtracting calculated ideal (iPVS = c × weight) from actual plasma volume (aPVS = (1 - haematocrit) × (a + (b × weight in kg)). RESULTS: The need for renal replacement therapy (1 (0.4%) vs 17 (4.5%); P = .001), re-operation for noncardiac reasons (9 (3.5%) vs 32 (8.4%); P = .003), re-operation for bleeding (9 (3.5%) vs 27 (7.1%); P = .037) and major bleeding (14 (5.4%) vs 37 (9.8%); P = .033) were significantly higher in patients with a PVS>-4. The composite 30-day early safety endpoint (234 (91.1%) vs 314 (82.8%); P = .002) confirms that an increased preoperative PVS is associated with a worse overall outcome after TAVI. CONCLUSIONS: An elevated PVS (>-4) as a marker for congestion is associated with significantly worse outcome after TAVI and therefore should be incorporated in preprocedural risk stratification.

12.
Ann Thorac Surg ; 105(4): e185-e187, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29329990

RESUMO

Performing transcatheter aortic valve implantation in the presence of aneurysmatic aortopathy is widely contraindicated but needs to be taken into account as a bailout strategy in selected patients. Deliberate preoperative assessment of measurements becomes the crucial key element in this context. After meticulous valve selection, retrograde access is obtained through the right subclavian artery additionally serving as a backup arterial cannulation site in case of conversion. Transcatheter aortic valve implantation is then performed through the transapical route. Transcatheter aortic valve implantation in complex aneurysmatic aortic morphology is feasible in highly selected patients after comprehensive preoperative evaluation. The present article describes our initial experience, safeguards, and technical details.


Assuntos
Aneurisma Aórtico/complicações , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA