Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Oral Rehabil ; 44(9): 683-690, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28644567

RESUMO

Assessment of swallowing musculature using motor evoked potentials (MEPs) can be used to evaluate neural pathways. However, recording of the swallowing musculature is often invasive, uncomfortable and unrealistic in normal clinical practice. To investigate the possibility of using the suprahyoid muscle complex (SMC) using surface electromyography (sEMG) to assess changes to neural pathways by determining the reliability of measurements in healthy participants over days. Seventeen healthy participants were recruited. Measurements were performed twice with one week between sessions. Single-pulse (at 120% and 140% of the resting motor threshold (rMT)) and paired-pulse (2 ms and 15 ms paired pulse) transcranial magnetic stimulation (TMS) were used to elicit MEPs in the SMC which were recorded using sEMG. ≈50% of participants (range: 42-58%; depending on stimulus type/intensity) had significantly different MEP values between day 1 and day 2 for single-pulse and paired-pulse TMS. A large stimulus artefact resulted in MEP responses that could not be assessed in four participants. The assessment of the SMC using sEMG following TMS was poorly reliable for ≈50% of participants. Although using sEMG to assess swallowing musculature function is easier to perform clinically and more comfortable to patients than invasive measures, as the measurement of muscle activity using TMS is unreliable, the use of sEMG for this muscle group is not recommended and requires further research and development.


Assuntos
Deglutição/fisiologia , Estimulação Elétrica/instrumentação , Eletromiografia , Potencial Evocado Motor/fisiologia , Contração Muscular/fisiologia , Músculos do Pescoço/fisiologia , Adulto , Análise de Variância , Feminino , Voluntários Saudáveis , Humanos , Masculino , Músculos do Pescoço/diagnóstico por imagem , Reprodutibilidade dos Testes
2.
J Oral Rehabil ; 44(9): 691-701, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28556188

RESUMO

The aim of this study is to investigate effects of transcranial direct current stimulation (tDCS) on neuroplasticity in corticomotor pathways related to tongue muscles evoked by a training task using the tongue drive system (TDS). Using a crossover design, 13 healthy participants completed two sessions of tDCS while performing 30 min of TDS training. Sessions were spaced at least 2 weeks apart and participants randomly received anodal and sham tDCS stimulation in the first session and the other condition in the second session. Single and paired pulse transcranial magnetic stimulation was used to elicit motor evoked potentials (MEPs) of the tongue at three time-points: before, immediately after and 30 min after training. Participant-based reports of fun, pain, fatigue and motivation, level of difficulty and effort were evaluated on numerical rating scales. There was no consistent significant effect of anodal and sham stimulation on single or paired pulse stimulation MEP amplitude immediately or 30 min after TDS training. Irrespective of tDCS type, training with TDS induced cortical plasticity in terms of increased MEP amplitudes for higher stimulus intensities after 30 min compared with before and immediately after training. Participant-based reports revealed no significant difference between tDCS conditions for level of fun, fatigue, motivation, difficulty and level of effort but a significant increase in pain in the anodal condition, although pain level was low for both conditions. In conclusion, tongue MEP amplitudes appear to be sensitive to training with the tongue using TDS; however, anodal tDCS does not have an impact on training-evoked neuroplasticity of tongue corticomotor pathways.


Assuntos
Eletromiografia , Potencial Evocado Motor/fisiologia , Plasticidade Neuronal/fisiologia , Língua/fisiologia , Estimulação Transcraniana por Corrente Contínua , Adulto , Estudos Cross-Over , Eletrofisiologia , Desenho de Equipamento , Feminino , Voluntários Saudáveis , Humanos , Masculino , Vias Neurais , Língua/anatomia & histologia
3.
Clin Neurophysiol ; 123(3): 541-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21839674

RESUMO

OBJECTIVE: Investigate if patients with supraspinal lesions have impaired interlimb spinal reflex pathways. The short-latency crossed spinal response will be investigated during sitting from the non-paretic to paretic and paretic to non-paretic extremities at different stimulation intensities in chronic and sub-acute stroke patients. METHODS: The ipsilateral tibial nerve of the paretic and non-paretic extremities were stimulated at motor threshold, 35% M-max and 85% M-max of the ipsilateral soleus while the contralateral soleus was contracted from 5% to 15% of the maximum voluntary contraction of the paretic soleus. RESULTS: Chronic patients (from both extremities) had significantly less prominent inhibitory responses than healthy controls (post hoc tests: P<.01-P<.05). The responses were significantly modulated by stimulus intensity in healthy controls and chronic patients (P<.001-P<.05) but not sub-acute patients (P>.05). Some sub-acute patients had significantly more variable responses than chronic patients and healthy controls (P<.001-P⩽.05). CONCLUSIONS: Short-latency interlimb reflexes are impaired differently in sub-acute vs. chronic patients, are impaired from the non-paretic and paretic extremity, and abnormal when compared to healthy controls. SIGNIFICANCE: The inappropriate coordination could result in an inability to quickly avoid obstacles following a mechanical disturbance to the ipsilateral extremity. It also indicates that bilateral descending projections affect the response.


Assuntos
Músculo Esquelético/inervação , Músculo Esquelético/fisiopatologia , Tempo de Reação/fisiologia , Medula Espinal/fisiopatologia , Acidente Vascular Cerebral/fisiopatologia , Doença Crônica , Vias Eferentes/fisiologia , Estimulação Elétrica , Eletromiografia , Feminino , Humanos , Perna (Membro)/inervação , Masculino , Pessoa de Meia-Idade , Contração Muscular/fisiologia , Músculo Esquelético/fisiologia
4.
Vet Radiol Ultrasound ; 40(3): 242-5, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10519301

RESUMO

Renal length and width dimensions were determined from survey radiography and excretory urography in 28 cats of various sex and reproductive status. Renal dimensions were expressed as a ratio to the length of the second lumbar vertebra. Renal dimensions were not significantly different when males were compared to females. However, significant differences in renal dimensions between intact and neutered cats were identified. Renal length ratios for neutered cats were: left kidney 2.22 +/- 0.14 (mean +/- standard deviation), right kidney 2.29 +/- 0.14. In intact cats, renal length ratios were: left kidney 2.60 +/- 0.19, right kidney 2.65 +/- 0.24. The mean renal length ratios for neutered cats was smaller than previously reported normal values. Thus, reproductive status should be considered when evaluating feline kidneys for alterations in size. Based on this study, normal feline renal length ratios range from 1.9 to 2.6 for neutered cats and 2.1 to 3.2 for intact cats.


Assuntos
Castração/veterinária , Gatos/anatomia & histologia , Rim/diagnóstico por imagem , Animais , Gatos/cirurgia , Feminino , Rim/anatomia & histologia , Masculino , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA