The bioavailability of acetate in various vinegar supplements, e.g. as capsules and drinks, remains unclear. Thus, we conducted a cross-over clinical study in 30 healthy subjects. After an overnight fast, subjects received each test sample in a randomised sequence: 9 vinegar capsules (containing 750 mg acetic acid in total) with 150 mL of water, 100 mL of vinegar drink (containing 750 mg acetic acid), and 150 mL of water as reference. Blood samples were collected before (defined as 0 min), at 15, 30, 45, 60, 90, 120 and 180 min after each test sample intake. In the vinegar drink group, serum acetate concentration increased immediately after intake, peaked at 15 min and returned to baseline at 90 min. That in the vinegar capsule group rose slowly, peaked at 30 min and returned to baseline at 120 min. The peak values in both groups exceeded 200 µmol/L, the physiologically active concentration confirmed by in vitro experiment. In the reference group, levels remained constant throughout the 180-min period. The amount of absorbed acetate from the vinegar capsule group and the drink group was evaluated by the difference value of the area under the serum acetate concentration-time curve (AUC) between in each vinegar group and in the reference group (expressed as AUC(capsule-ref) and AUC(drink-ref ), respectively). AUC(capsule-ref) was about 80% of AUC(drink-ref ), but there was no significant difference between them.


Assuntos
Acetatos/sangue , Ácido Acético/farmacocinética , Suplementos Nutricionais , Ácido Acético/administração & dosagem , Adulto , Área Sob a Curva , Bebidas , Disponibilidade Biológica , Cápsulas , Estudos Cross-Over , Jejum , Feminino , Humanos , Absorção Intestinal , Masculino , Pessoa de Meia-Idade , Método Simples-Cego
2.
J Vet Med Sci ; 65(3): 363-8, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12679567

RESUMO

A Denacol EX-313 (Denacol)-treated bovine venous graft and an ultrafine polyester fiber (UFPF) graft were transplanted as patch graft into the right ventricular outflow tract under extracorporeal circulation in six dogs each experimentally. Hemodynamics in right heart and histological findings around the graft were compared between both groups over a period of one year after grafting. Pressure measurements and angiocardiography were performed through a cardiac catheter. Right ventricular pressure, pulmonary artery pessure, and right ventricle to pulmonary artery gradient were within normal limits in both groups at 1, 2, 3, 4, 6, and 12 months or more after grafting. No difference were seen between the values for the Denacol and the UFPF group. Histologically, the medial surface at the site of grafting was covered with vascular endothelial cells at one month after grafting in both groups. The density of the vascular endothelial cells increased with time after grafting, showing no clear difference between the two groups. Subendothelial layers comprised of collagen fibers, elastic fibers, and inflammatory cells decreased with time in both groups, but there was less cell infiltration in the Denacol group than in the UFPF group at all time points after grafting. In addition, the central cut thickness value of the graft tended to be thinner in the Denacol group than in the UFPF group at all observation time points after grafting. In the Denacol group, very slight metaplasia of cartilage was noted in a portion of the graft margin at six months or more after grafting, but no other abnormalities were observed. These results suggest that the Denacol-treated bovine venous graft has better grafting characteristics than the UFPF graft with easier intra-operative handlings and less tissue reactions after grafting.


Assuntos
Prótese Vascular/veterinária , Cães/cirurgia , Veias Jugulares/transplante , Poliésteres , Polipropilenos , Animais , Bovinos , Feminino , Hemodinâmica , Veias Jugulares/ultraestrutura , Masculino , Fatores de Tempo