Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Int J Oral Maxillofac Implants ; 38(6): 1135-1144, 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38085744

RESUMO

PURPOSE: To examine the stresses caused by different All-on-4 surgical techniques-conventional, a combination of monocortical and bicortical, bicortical, and nasal floor elevation-on the implant and the surrounding bone using 3D finite element analysis (FEA). MATERIALS AND METHODS: A 3D bone model of the atrophic maxilla was created based on CT imaging of the fully edentulous adult patient. All implants used in the models were 4 mm in diameter, and the length was 13 mm in the anterior and 15 mm in the posterior. Implants were applied to four different atrophic maxillary models with the All-on-4 technique: anterior and posterior monocortical implants in the first model, anterior monocortical and posterior bicortical in the second model, anterior and posterior bicortical in the third model, and anterior and posterior bicortical with nasal floor elevation in the fourth model. Eight linear analyses were performed by applying force from both vertical and 45-degree oblique directions to the four models prepared in our study. RESULTS: When the cortical and cancellous bone around the anterior implants was examined, it was observed that the oblique and vertical loading conditions and the stresses around the implant were similar in all models. When the posterior implants were examined, model 1 (ie, anterior and posterior monocortical implants) showed the greatest oblique compression, vertical compression, and vertical tension forces. According to the Von Mises stress (VMS) analysis results for anterior and posterior implants, higher values were observed in model 1 compared to models 3 and 4 under oblique and vertical forces. It was observed that bicortical placement of the implants reduced the stresses on the bone and implant-abutment system but had no significant effect on the stress on the bar. CONCLUSIONS: According to the results of our study, in the All-on-4 technique, bicortical placement of the implants reduced the stresses on the bone and implant when the anatomical limitations allowed. In addition, nasal floor elevation can be applied in the atrophic maxilla in appropriate indications.


Assuntos
Implantes Dentários , Humanos , Análise de Elementos Finitos , Maxila/diagnóstico por imagem , Maxila/cirurgia , Estresse Mecânico , Análise do Estresse Dentário/métodos , Fenômenos Biomecânicos , Planejamento de Prótese Dentária
2.
Int J Oral Maxillofac Implants ; 0(0): 0, 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37672395

RESUMO

PURPOSE: To examine the stresses caused by different All-on-4 surgical techniques-conventional, a combination of monocortical and bicortical, bicortical, and nasal floor elevation-on the implant and the surrounding bone using 3D finite element analysis (FEA). MATERIALS AND METHODS: A 3D bone model of the atrophic maxilla was created based on CT imaging of the fully edentulous adult patient. All implants used in the models were 4 mm in diameter, and the length was 13 mm in the anterior and 15 mm in the posterior. Implants were applied to four different atrophic maxillary models with the All-on-4 technique: anterior and posterior monocortical implants in the first model, anterior monocortical and posterior bicortical in the second model, anterior and posterior bicortical in the third model, and anterior and posterior bicortical with nasal floor elevation in the fourth model. Eight linear analyses were performed by applying force from both vertical and 45-degree oblique directions to the four models prepared in our study. RESULTS: When the cortical and cancellous bone around the anterior implants was examined, it was observed that the oblique and vertical loading conditions and the stresses around the implant were similar in all models. When the posterior implants were examined, model 1 (ie, anterior and posterior monocortical implants) showed the greatest oblique compression, vertical compression, and vertical tension forces. According to the Von Mises stress (VMS) analysis results for anterior and posterior implants, higher values were observed in model 1 compared to models 3 and 4 under oblique and vertical forces. It was observed that bicortical placement of the implants reduced the stresses on the bone and implant-abutment system but had no significant effect on the stress on the bar. CONCLUSIONS: According to the results of our study, in the All-on-4 technique, bicortical placement of the implants reduced the stresses on the bone and implant when the anatomical limitations allowed. In addition, nasal floor elevation can be applied in the atrophic maxilla in appropriate indications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA