Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
J Clin Pharmacol ; 64(1): 125-136, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37656820

RESUMO

The immunogenicity of cemiplimab, a fully human immunoglobulin G4 monoclonal antibody directed against programmed cell death 1, was assessed in patients across multiple tumor types. The development of antidrug antibodies (ADAs) against cemiplimab was monitored using a validated bridging immunoassay. To identify ADA-positive samples in the assay, statistically determined cut points were established by analyzing baseline clinical study samples from a mixed population of different tumor types, and this validation cut point was used to assess immunogenicity in all subsequent studies. Regulatory guidance requires that ADA assay cut points be verified for appropriateness in different patient populations. Thus, for the cemiplimab ADA assay, we evaluated whether each new oncology population was comparable with the validation population used to set the cut point. Assay responses from 2393 individual serum samples from 8 different tumor types were compared with the validation population, using established statistical methods for cut-point determination and comparison, with no significant differences observed. Across tumor types, the immunogenicity of cemiplimab was low, with an overall treatment-emergent ADA incidence rate of 1.9% and 2.5% at intravenous dose regimens of 3 mg/kg every 2 weeks and 350 mg every 3 weeks, respectively. Moreover, no neutralizing antibodies to cemiplimab were detected in patients with ADA-positive samples, and there was no observed impact of cemiplimab ADAs on pharmacokinetics. Study-specific cut points may be required in some diseases, such as immune and inflammatory diseases; however, based on this analysis, in-study cut points are not required for each new oncology disease indication for cemiplimab.


Assuntos
Anticorpos Monoclonais Humanizados , Neoplasias , Humanos , Incidência , Anticorpos Monoclonais Humanizados/uso terapêutico , Anticorpos Monoclonais/uso terapêutico , Neoplasias/tratamento farmacológico
2.
Bioanalysis ; 15(15): 861-903, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37584363

RESUMO

The 16th Workshop on Recent Issues in Bioanalysis (16th WRIB) took place in Atlanta, GA, USA on September 26-30, 2022. Over 1000 professionals representing pharma/biotech companies, CROs, and multiple regulatory agencies convened to actively discuss the most current topics of interest in bioanalysis. The 16th WRIB included 3 Main Workshops and 7 Specialized Workshops that together spanned 1 week in order to allow exhaustive and thorough coverage of all major issues in bioanalysis, biomarkers, immunogenicity, gene therapy, cell therapy and vaccines. Moreover, in-depth workshops on ICH M10 BMV final guideline (focused on this guideline training, interpretation, adoption and transition); mass spectrometry innovation (focused on novel technologies, novel modalities, and novel challenges); and flow cytometry bioanalysis (rising of the 3rd most common/important technology in bioanalytical labs) were the special features of the 16th edition. As in previous years, WRIB continued to gather a wide diversity of international, industry opinion leaders and regulatory authority experts working on both small and large molecules as well as gene, cell therapies and vaccines to facilitate sharing and discussions focused on improving quality, increasing regulatory compliance, and achieving scientific excellence on bioanalytical issues. This 2022 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2022 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 2) covers the recommendations on LBA, Biomarkers/CDx and Cytometry. Part 1 (Mass Spectrometry and ICH M10) and Part 3 (Gene Therapy, Cell therapy, Vaccines and Biotherapeutics Immunogenicity) are published in volume 15 of Bioanalysis, issues 16 and 14 (2023), respectively.


Assuntos
Bioensaio , Relatório de Pesquisa , Citometria de Fluxo/métodos , Ligantes , Biomarcadores/análise , Bioensaio/métodos
3.
AAPS J ; 25(3): 37, 2023 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-37016171

RESUMO

The statistical assessments needed to establish anti-drug antibody (ADA) assay cut points (CPs) can be challenging for bioanalytical scientists. Poorly established CPs that are too high could potentially miss treatment emergent ADA or, when set too low, result in detection of responses that may have no clinical relevance. We evaluated 16 validation CP datasets generated with ADA assays at Regeneron's bioanalytical laboratory and compared results obtained from different CP calculation tools. We systematically evaluated the impact of various factors on CP determination including biological and analytical variability, number of samples for capturing biological variability, outlier removal methods, and the use of parametric vs. non-parametric CP determination. In every study, biological factors were the major component of assay response variability, far outweighing the contribution from analytical variability. Non-parametric CP estimations resulted in screening positivity in drug-naïve samples closer to the targeted rate (5%) and were less impacted by skewness. Outlier removal using the boxplot method with an interquartile range (IQR) factor of 3.0 resulted in screening positivity close to the 5% targeted rate when applied to entire drug-naïve dataset. In silico analysis of CPs calculated using different sample sizes showed that using larger numbers of individuals resulted in CP estimates closer to the CP of the entire population, indicating a larger sample size (~ 150) for CP determination better represents the diversity of the study population. Finally, simpler CP calculations, such as the boxplot method performed in Excel, resulted in CPs similar to those determined using complex methods, such as random-effects ANOVA.


Assuntos
Anticorpos , Humanos , Tamanho da Amostra
4.
AAPS J ; 24(4): 78, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35778641

RESUMO

Twenty percent of baseline patient samples exhibited a pre-existing response in a bridging anti-drug antibody (ADA) assay for a human IgG4 monoclonal antibody (mAb) therapeutic. In some cases, assay signals were more than 100-fold higher than background, potentially confounding detection of true treatment-emergent ADA responses. The pre-existing reactivity was mapped by competitive inhibition experiments using recombinant proteins or chimeric human mAbs with IgG4 heavy chain regions swapped for IgG1 sequences. These experiments demonstrated that the majority of the samples had reactivity to an epitope containing leucine 445 in the CH3 domain of human IgG4. The pre-existing reactivity in baseline patient samples was mitigated by replacing the ADA assay capture reagent with a version of the drug containing a wild type IgG1 proline substitution at residue 445 without impacting detection of drug-specific, treatment-emergent ADA. Finally, purification on Protein G or anti-human IgG (H + L) columns indicated the pre-existing response was likely due to immunoglobulins in patient samples.


Assuntos
Anticorpos Monoclonais , Imunoglobulina G , Epitopos , Humanos , Imunoglobulina G/química
5.
Bioanalysis ; 14(9): 505-580, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35578993

RESUMO

The 15th edition of the Workshop on Recent Issues in Bioanalysis (15th WRIB) was held on 27 September to 1 October 2021. Even with a last-minute move from in-person to virtual, an overwhelmingly high number of nearly 900 professionals representing pharma and biotech companies, contract research organizations (CROs), and multiple regulatory agencies still eagerly convened to actively discuss the most current topics of interest in bioanalysis. The 15th WRIB included 3 Main Workshops and 7 Specialized Workshops that together spanned 1 week in order to allow exhaustive and thorough coverage of all major issues in bioanalysis, biomarkers, immunogenicity, gene therapy, cell therapy and vaccines. Moreover, in-depth workshops on biomarker assay development and validation (BAV) (focused on clarifying the confusion created by the increased use of the term "Context of Use - COU"); mass spectrometry of proteins (therapeutic, biomarker and transgene); state-of-the-art cytometry innovation and validation; and, critical reagent and positive control generation were the special features of the 15th edition. This 2021 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2021 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 1A) covers the recommendations on Endogenous Compounds, Small Molecules, Complex Methods, Regulated Mass Spec of Large Molecules, Small Molecule, PoC. Part 1B covers the Regulatory Agencies' Inputs on Bioanalysis, Biomarkers, Immunogenicity, Gene & Cell Therapy and Vaccine. Part 2 (ISR for Biomarkers, Liquid Biopsies, Spectral Cytometry, Inhalation/Oral & Multispecific Biotherapeutics, Accuracy/LLOQ for Flow Cytometry) and Part 3 (TAb/NAb, Viral Vector CDx, Shedding Assays; CRISPR/Cas9 & CAR-T Immunogenicity; PCR & Vaccine Assay Performance; ADA Assay Comparabil ity & Cut Point Appropriateness) are published in volume 14 of Bioanalysis, issues 10 and 11 (2022), respectively.


Assuntos
Vesículas Extracelulares , Vacinas , Biomarcadores/análise , Terapia Baseada em Transplante de Células e Tecidos , Vesículas Extracelulares/química , Humanos , Espectrometria de Massas/métodos , Nanomedicina
6.
Bioanalysis ; 14(8): 491-502, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35297286

RESUMO

Aim: To mitigate assay interference in the drug and target assays to support the development of monoclonal antibody REGN-Z. Results: Mild acidic assay conditions and capture and detection antibodies with different affinities and t1/2 under different assay pHs were used to mitigate interference in the total drug and total target assays. A free target assay was also developed using a lower-affinity capture antibody with a much slower association and dissociation rate. The impact of sample incubation, dilution and storage on the accurate detection of the free target was also evaluated. Conclusion: The total drug, total and free target assays can accurately quantitate drug and target concentrations when tested with a subset of clinical study samples.


Assuntos
Anticorpos Monoclonais , Bioensaio , Indicadores e Reagentes
7.
J Infect Dis ; 225(10): 1765-1772, 2022 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-33507266

RESUMO

BACKGROUND: REGN3048 and REGN3051 are human monoclonal antibodies (mAb) targeting the spike glycoprotein on the Middle East respiratory syndrome coronavirus (MERS-CoV), which binds to the receptor dipeptidyl peptidase-4 (DPP4) and is necessary for infection of susceptible cells. METHODS: Preclinical study: REGN3048, REGN3051 and isotype immunoglobulin G (IgG) were administered to humanized DPP4 (huDPP4) mice 1 day prior to and 1 day after infection with MERS-CoV (Jordan strain). Virus titers and lung pathology were assessed. Phase 1 study: healthy adults received the combined mAb (n = 36) or placebo (n = 12) and followed for 121 days. Six dose levels were studied. Strict safety criteria were met prior to dose escalation. RESULTS: Preclinical study: REGN3048 plus REGN3051, prophylactically or therapeutically, was substantially more effective for reducing viral titer, lung inflammation, and pathology in huDPP4 mice compared with control antibodies and to each antibody monotherapy. Phase 1 study: REGN3048 plus REGN3051 was well tolerated with no dose-limiting adverse events, deaths, serious adverse events, or infusion reactions. Each mAb displayed pharmacokinetics expected of human IgG1 antibodies; it was not immunogenic. CONCLUSIONS: REGN3048 and REGN3051 in combination were well tolerated. The clinical and preclinical data support further development for the treatment or prophylaxis of MERS-CoV infection.


Assuntos
Infecções por Coronavirus , Coronavírus da Síndrome Respiratória do Oriente Médio , Animais , Anticorpos Monoclonais/uso terapêutico , Anticorpos Neutralizantes/uso terapêutico , Anticorpos Antivirais/uso terapêutico , Infecções por Coronavirus/tratamento farmacológico , Infecções por Coronavirus/prevenção & controle , Dipeptidil Peptidase 4/metabolismo , Humanos , Imunoglobulina G , Camundongos , Glicoproteína da Espícula de Coronavírus
8.
Bioanalysis ; 13(23): 1751-1760, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34758642

RESUMO

Aim: IL-33 is a potential therapeutic target but commercially available assays for the quantitation of systemic IL-33 have poor reliability. Results: In commercial IL-33 kits, interference from endogenous binding partners (e.g., soluble ST2) causes under-quantitation. Mitigating this required acid dissociation and addition of the detection reagent simultaneously with the capture step. This enabled detection of total, reduced (active) levels of IL-33 in human serum (LLOQ 6.25 pg/ml). Conclusion: Acid treatment of serum samples dissociates IL-33 from endogenous binding partners, increasing soluble ST2 tolerance to >1000 ng/ml. The modified method was specific for reduced endogenous IL-33. Analysis of over 300 samples from individuals with and without asthma and with different smoking status revealed no difference in serum IL-33.


Assuntos
Proteína 1 Semelhante a Receptor de Interleucina-1/química , Interleucina-33/sangue , Asma/sangue , Asma/patologia , Humanos , Imunoensaio , Proteína 1 Semelhante a Receptor de Interleucina-1/metabolismo , Interleucina-33/química , Interleucina-33/genética , Interleucina-33/metabolismo , Limite de Detecção , Oxirredução , Ligação Proteica , Kit de Reagentes para Diagnóstico , Proteínas Recombinantes/análise , Proteínas Recombinantes/biossíntese , Proteínas Recombinantes/isolamento & purificação , Fumar
9.
Bioanalysis ; 13(24): 1827-1836, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34743612

RESUMO

Aim: In response to the COVID-19 pandemic, Regeneron developed the anti-SARS-CoV-2 monoclonal antibody cocktail, REGEN-COV® (RONAPREVE® outside the USA). Drug concentration data was important for determination of dose, so a two-part bioanalytical strategy was implemented to ensure the therapy was rapidly available for use. Results & methodology: Initially, a liquid chromatography-multiple reaction monitoring-mass spectrometry (LC-MRM-MS) assay, was used to analyze early-phase study samples. Subsequently, a validated electrochemiluminescence (ECL) immunoassay was implemented for high throughput sample analysis for all samples. A comparison of drug concentration data from the methods was performed which identified strong linear correlations and for Bland-Altman, small bias. In addition, pharmacokinetic data from both methods produced similar profiles and parameters. Discussion & conclusion: This novel bioanalytical strategy successfully supported swift development of a critical targeted therapy during the COVID-19 public health emergency.


Assuntos
Anticorpos Monoclonais/análise , COVID-19/terapia , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , SARS-CoV-2/imunologia , Anticorpos Monoclonais/uso terapêutico , COVID-19/virologia , Técnicas Eletroquímicas , Humanos , Luminescência
10.
AAPS J ; 23(6): 109, 2021 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-34608545

RESUMO

Monoclonal antibodies (mAbs) are a leading class of biotherapeutics. In oncology, patients often fail on early lines of biologic therapy to a specific target. Some patients may then enroll in a new clinical trial with a mAb specific for the same target. Therefore, immunoassays designed to quantify the current mAb therapy or assess immunogenicity to the drug may be susceptible to cross-reactivity or interference with residual prior biologics. The impact of two approved anti-PD-1 mAbs, pembrolizumab and nivolumab, was tested in several immunoassays for cemiplimab, another approved anti-PD-1 mAb. The methods included a target-capture drug concentration assay, a bridging anti-drug antibody (ADA) assay and a competitive ligand-binding neutralizing antibody (NAb) assay. We also tested bioanalytical strategies to mitigate cross-reactivity or interference in these assays from other anti-PD-1 biologics. Both pembrolizumab and nivolumab cross-reacted in the cemiplimab drug concentration assay. This was mitigated by addition of antibodies specific to pembrolizumab or nivolumab. ADA specific for pembrolizumab and nivolumab did not interfere in the cemiplimab ADA assay. However, pembrolizumab and nivolumab generated a false-positive response in a target-capture NAb assay. Our results demonstrate that similar exogenous pre-existing anti-PD-1 mAbs (biotherapeutics) such as pembrolizumab and nivolumab are detected and accurately quantified in the cemiplimab drug concentration assay. However, once steady state is achieved for the new therapy, prior biologics would likely not be detected. Cross-reactivity and interference in immunoassays from previous treatment with class-specific biotherapeutic(s) pose significant bioanalytical challenges, especially in immuno-oncology.


Assuntos
Anticorpos Monoclonais Humanizados/imunologia , Antineoplásicos Imunológicos/imunologia , Nivolumabe/imunologia , Anticorpos Monoclonais Humanizados/sangue , Anticorpos Neutralizantes/imunologia , Antineoplásicos Imunológicos/sangue , Ligação Competitiva , Reações Cruzadas , Humanos , Inibidores de Checkpoint Imunológico/sangue , Inibidores de Checkpoint Imunológico/imunologia , Imunoensaio/métodos , Nivolumabe/sangue
11.
J Infect Dis ; 224(11): 1830-1838, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34496013

RESUMO

BACKGROUND: Elucidating the relationship between severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) viral load and clinical outcomes is critical for understanding coronavirus disease 2019 (COVID-19). METHODS: The SARS-CoV-2 levels were analyzed by quantitative real-time polymerase chain reaction (RT-qPCR) of nasopharyngeal or oropharyngeal swab specimens collected at baseline, and clinical outcomes were recorded over 60 days from 1362 COVID-19 hospitalized patients enrolled in a multicenter, randomized, placebo-controlled phase 2/3 trial of sarilumab for COVID-19 (ClinicalTrials.gov NCT04315298). RESULTS: In post hoc analyses, higher baseline viral load, measured by both RT-qPCR cycle threshold and log10 copies/mL, was associated with greater supplemental oxygenation requirements and disease severity at study entry. Higher baseline viral load was associated with higher mortality, lower likelihood of improvement in clinical status and supplemental oxygenation requirements, and lower rates of hospital discharge. Viral load was not impacted by sarilumab treatment over time versus placebo. CONCLUSIONS: These data support viral load as an important determinant of clinical outcomes in hospitalized patients with COVID-19 requiring supplemental oxygen or assisted ventilation.


Assuntos
COVID-19 , Carga Viral , COVID-19/diagnóstico , COVID-19/mortalidade , Humanos , Nasofaringe/virologia , Orofaringe/virologia , Respiração Artificial , SARS-CoV-2
12.
Anal Chem ; 93(38): 12889-12898, 2021 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-34463470

RESUMO

REGEN-COV is a cocktail of two human IgG1 monoclonal antibodies (REGN10933 + REGN10987) that targets severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein and has shown great promise to reduce the SARS-CoV-2 viral load in COVID-19 patients enrolled in clinical studies. A liquid chromatography-multiple reaction monitoring-mass spectrometry (LC-MRM-MS)-based method, combined with trypsin and rAspN dual enzymatic digestion, was developed for the determination of total REGN10933 and total REGN10987 concentrations in several hundreds of pharmacokinetic (PK) serum samples from COVID-19 patients participating in phase I, II, and III clinical studies. The performance characteristics of this bioanalytical assay were evaluated with respect to linearity, accuracy, precision, selectivity, specificity, and analyte stability before and after enzymatic digestion. The developed LC-MRM-MS assay has a dynamic range from 10 to 2000 µg/mL antibody drug in the human serum matrix, which was able to cover the serum drug concentration from day 0 to day 28 after drug administration in two-dose groups for the clinical PK study of REGEN-COV. The concentrations of REGEN-COV in the two-dose groups measured by the LC-MRM-MS assay were comparable to the concentrations measured by a fully validated electrochemiluminescence (ECL) immunoassay.


Assuntos
COVID-19 , Anticorpos Monoclonais , Cromatografia Líquida , Humanos , SARS-CoV-2 , Espectrometria de Massas em Tandem
13.
AAPS J ; 23(1): 16, 2021 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-33404777

RESUMO

There is an urgent demand to develop new technologies to characterize immunogenicity to biotherapeutics. Here, we developed an immunocapture LC-MS assay to isotype and semi-quantify monkey anti-drug antibodies (ADAs) to fully human monoclonal antibody (mAb) drugs. ADAs were isolated from serum samples using an immunocapture step with the Fab of the full-length mAb cross-linked to magnetic beads to minimize matrix interference. A positive monoclonal antibody control against the human immunoglobulin kappa light chain was used as a calibration standard for ADA quantitation. The final LC-MS method contains 17 multiple reaction monitoring (MRM) transitions and an optimized 15-min LC method. The results suggested that IgG1 was the most abundant isotype in ADA-positive samples. IgG2 and IgG4 were identified at lower levels, whereas IgG3 and IgA levels were only observed at very minor levels. In addition, levels of total ADA measured by the LC-MS assay were comparable to results obtained using a traditional ligand binding assay (LBA). The LC-MS ADA assay enabled rapid immunogenicity assessment with additional isotype information that LBAs cannot provide.


Assuntos
Anticorpos Monoclonais/imunologia , Anticorpos Neutralizantes/sangue , Produtos Biológicos/imunologia , Imunoglobulina G/sangue , Espectrometria de Massas em Tandem/métodos , Animais , Anticorpos Monoclonais/administração & dosagem , Anticorpos Monoclonais/efeitos adversos , Anticorpos Monoclonais/farmacocinética , Anticorpos Neutralizantes/imunologia , Produtos Biológicos/administração & dosagem , Produtos Biológicos/efeitos adversos , Produtos Biológicos/farmacocinética , Calibragem , Cromatografia Líquida de Alta Pressão/métodos , Avaliação Pré-Clínica de Medicamentos/métodos , Ensaio de Imunoadsorção Enzimática , Meia-Vida , Imunoglobulina A/sangue , Imunoglobulina A/imunologia , Imunoglobulina G/imunologia , Injeções Intravenosas , Macaca fascicularis
14.
Bioanalysis ; 13(5): 295-361, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33511867

RESUMO

The 14th edition of the Workshop on Recent Issues in Bioanalysis (14th WRIB) was held virtually on June 15-29, 2020 with an attendance of over 1000 representatives from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations, and regulatory agencies worldwide. The 14th WRIB included three Main Workshops, seven Specialized Workshops that together spanned 11 days in order to allow exhaustive and thorough coverage of all major issues in bioanalysis, biomarkers, immunogenicity, gene therapy and vaccine. Moreover, a comprehensive vaccine assays track; an enhanced cytometry track and updated Industry/Regulators consensus on BMV of biotherapeutics by LCMS were special features in 2020. As in previous years, this year's WRIB continued to gather a wide diversity of international industry opinion leaders and regulatory authority experts working on both small and large molecules to facilitate sharing and discussions focused on improving quality, increasing regulatory compliance and achieving scientific excellence on bioanalytical issues. This 2020 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the Global Bioanalytical Community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2020 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication covers the recommendations on (Part 2A) BAV, PK LBA, Flow Cytometry Validation and Cytometry Innovation and (Part 2B) Regulatory Input. Part 1 (Innovation in Small Molecules, Hybrid LBA/LCMS & Regulated Bioanalysis), Part 3 (Vaccine, Gene/Cell Therapy, NAb Harmonization and Immunogenicity) are published in volume 13 of Bioanalysis, issues 4, and 6 (2021), respectively.


Assuntos
Bioensaio , Biotecnologia , Terapia Baseada em Transplante de Células e Tecidos , Terapia Genética , Relatório de Pesquisa , Biomarcadores/análise , Humanos
15.
AAPS J ; 22(5): 112, 2020 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-32808205

RESUMO

Neutralizing anti-drug antibody (NAb) assays often have lower drug tolerance (DT) than trough drug concentrations, potentially under-estimating NAb incidence. To improve DT, drug-specific proteins were coupled to magnetic beads to deplete drug in the sample. To avoid interference from carryover, drug-specific proteins that did not interfere in the NAb assay, such as target or non-blocking anti-drug antibodies, were selected. With the drug depletion step, DT improved by > 10-fold in two competitive ligand binding NAb assays. Analysis of anti-drug antibody positive clinical samples with elevated drug levels demonstrated that NAb incidence was under-estimated without the drug depletion step. However, these NAb-positive samples had low titer and no impact on drug concentrations.


Assuntos
Anticorpos Monoclonais/isolamento & purificação , Anticorpos Neutralizantes/análise , Imunogenética/métodos , Preparações Farmacêuticas/isolamento & purificação , Humanos
16.
Bioanalysis ; 12(15): 1071-1085, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32735128

RESUMO

Background: Soluble multimeric target proteins can generate a target-mediated false-positive signal in bridging anti-drug antibody (ADA) assays. A high background signal due to target interference was observed in our anti-REGN-Y antibody assay, and two different strategies were evaluated to mitigate this false-positive signal. Results: Multiple anti-target antibodies were tested and found to be ineffective at reducing target interference, so soluble target receptor and co-factor proteins were used in combination to inhibit the target-mediated signal. These competitive blockers synergistically inhibited target interference and increased target tolerance levels, especially when the assay was performed under mild acidic conditions. A separate approach, target immunodepletion using magnetic beads conjugated with an anti-target antibody, was also effective at mitigating the target-mediated signal, also in combination with mild acidic assay pH. Both methods allowed detection of a true ADA signal in monkey and human post-dose serum samples. Conclusion: These methods provide alternative strategies for mitigating target interference when standard anti-target antibodies are ineffective, with the competitive blocker method being recommended, if possible, due to its higher throughput and easier execution.


Assuntos
Bioensaio/métodos , Imunogenética/métodos , Humanos , Concentração de Íons de Hidrogênio
17.
Bioanalysis ; 11(17): 1569-1580, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31208197

RESUMO

Background: Soluble drug target in clinical study samples generated false positive results in anti-drug antibody (ADA) bridging assays due to target-mediated bridging. Results: The combination of two target-blocking reagents and mild basic assay pH resulted in high tolerance to recombinant target protein and reduced levels of positivity in clinical study samples with pharmacokinetic profiles that did not indicate significant ADA response. Testing with low-affinity ADA positive serum from immunized rabbits and known ADA positive samples from nonclinical studies in rats confirmed the assay's ability to detect ADA positive samples and the minimal impact of basic pH and target-blocking reagents on ADA detection. Conclusion: These strategies provide alternatives for mitigating target interference when standard target-blocking antibodies alone are ineffective.


Assuntos
Anticorpos/sangue , Anticorpos/imunologia , Técnicas Imunológicas , Animais , Reações Falso-Positivas , Concentração de Íons de Hidrogênio , Preparações Farmacêuticas , Coelhos , Ratos
18.
Bioanalysis ; 11(5): 381-392, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30892063

RESUMO

AIM: To evaluate the accuracy of the Quantikine Human VEGF Immunoassay (R&D Systems) in the presence of VEGF inhibitors. MATERIALS & METHODS: Quantikine VEGF ELISA (R&D), anti-VEGF165 mAb (R&D), VEGF165 and aflibercept (Regeneron), ranibizumab and bevacizumab (Genentech). RESULTS: Binding affinity of anti-VEGF165 mAb for VEGF was threefold weaker than aflibercept, but 33- and 40-fold stronger than ranibizumab or bevacizumab. Extended incubation of VEGF complexed with inhibitors led to VEGF dissociation from ranibizumab and bevacizumab, but not aflibercept, and subsequent binding by the immunoassay capture antibody. The immunoassay also detected VEGF:ranibizumab and VEGF:bevacizumab complexes but not VEGF:aflibercept complexes. CONCLUSION: The immunoassay cannot accurately quantitate VEGF in the presence of these VEGF inhibitors as they interfere with the capture and detection of free VEGF.


Assuntos
Inibidores da Angiogênese/uso terapêutico , Ensaio de Imunoadsorção Enzimática/métodos , Fator A de Crescimento do Endotélio Vascular/uso terapêutico , Inibidores da Angiogênese/farmacologia , Humanos , Fator A de Crescimento do Endotélio Vascular/farmacologia
19.
Lancet Infect Dis ; 18(8): 884-893, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29929783

RESUMO

BACKGROUND: REGN3470-3471-3479 is a co-formulated cocktail of three human monoclonal antibodies targeting three non-overlapping epitopes on Ebola virus. We investigated safety, tolerability, pharmacokinetics, and anti-drug antibodies in healthy adults. METHODS: This randomised, double-blind, placebo-controlled, dose-escalation study was done at a phase 1 unit in the USA. Healthy adults, aged 18-60 years, with a body-mass index of 18·0-30·0 kg/m2 were randomly assigned (3:1) to receive a single intravenous dose of REGN3470-3471-3479 or placebo on day 1 (baseline) in one of the four sequential ascending intravenous dose cohorts (3 mg/kg, 15 mg/kg, 60 mg/kg, and 150 mg/kg). Site investigators and participants were masked to the treatment assignment, whereas designated personnel at the site who prepared and generated the study medication were aware of the randomisation treatment assignments. The primary outcome was safety and the secondary outcomes were the pharmacokinetic profiles and immunogenicity. Study assessments were done the day before study drug administration, on the day of drug administration, on day 2 (before discharge), on days 3, 4, 8, 15, 29, 57, 85, 113, and 141, and at the end of study on day 169. The safety analysis included all randomised participants who received study drug. This trial is registered with ClinicalTrials.gov, number NCT002777151. FINDINGS: Between May 18, 2016, and October 27, 2016, 70 adults were screened and 24 participants were enrolled in the study. 18 participants were assigned to and received REGN3470-3471-3479, and six participants were assigned to and received placebo as a single intravenous infusion. 19 treatment-emergent adverse events occurred in the combined REGN3470-3471-3479 treatment groups, and four treatment-emergent adverse events occurred in combined placebo groups. Adverse events were transient and mild-to-moderate in severity. The most common treatment-emergent adverse event was headache (six [33%] of 18 participants in the combined REGN3470-3471-3479 group vs none of six participants in the placebo group. Headaches were mild-to-moderate in severity, with onset between 2 h and 27 days after start of study drug infusion. There were no deaths, serious adverse events, or adverse events that led to study discontinuation. The pharmacokinetics of each antibody was linear, with mean half-lives of 27·3 days for REGN3471, 21·7 days for REGN3470, and 23·3 days for REGN3479. No participants tested positive for anti-REGN3470, anti-REGN3471, or anti-REGN3479 antibodies. INTERPRETATION: REGN3470-3471-3479 was well tolerated, displayed linear pharmacokinetics, and did not lead to detectable immunogenicity. These data support further clinical development of REGN3470-3471-3479 as a single-dose therapeutic drug for acute Ebola virus infection. FUNDING: The Department of Health and Human Services, the Office of the Assistant Secretary for Preparedness and Response, and the Biomedical Advanced Research and Development Authority.


Assuntos
Administração Intravenosa , Anticorpos Monoclonais/farmacocinética , Glicoproteínas , Voluntários Saudáveis , Doença pelo Vírus Ebola/prevenção & controle , Segurança do Paciente , Adolescente , Adulto , Anticorpos Antivirais/sangue , Método Duplo-Cego , Ebolavirus/isolamento & purificação , Feminino , Cefaleia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estados Unidos , Adulto Jovem
20.
Bioanalysis ; 9(24): 1967-1996, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29205064

RESUMO

The 2017 11th Workshop on Recent Issues in Bioanalysis took place in Los Angeles/Universal City, California, on 3-7 April 2017 with participation of close to 750 professionals from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5-day, week-long event - a full immersion week of bioanalysis, biomarkers and immunogenicity. As usual, it was specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small- and large-molecule analysis involving LC-MS, hybrid ligand-binding assay (LBA)/LC-MS and LBA approaches. This 2017 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2017 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 3) covers the recommendations for large-molecule bioanalysis, biomarkers and immunogenicity using LBA. Part 1 (LC-MS for small molecules, peptides and small molecule biomarkers) and Part 2 (hybrid LBA/LC-MS for biotherapeutics and regulatory agencies' inputs) are published in volume 9 of Bioanalysis, issues 22 and 23 (2017), respectively.


Assuntos
Biomarcadores/análise , Imunidade Ativa , Cromatografia Líquida , Conferências de Consenso como Assunto , Tolerância a Medicamentos , Guias como Assunto , Ligantes , Espectrometria de Massas , Farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA