Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Taehan Yongsang Uihakhoe Chi ; 82(6): 1545-1555, 2021 Nov.
Artigo em Coreano | MEDLINE | ID: mdl-36238883

RESUMO

Purpose: The purpose of this study was to evaluate the rates of unacceptable diagnosis and clinically significant diagnostic discrepancy in radiology sections and imaging modalities through a peer review of teleradiology. Materials and Methods: Teleradiology peer reviews in a Korean teleradiology clinic in 2018 and 2019 were included. The peer review scores were classified as acceptable and unacceptable diagnoses and clinically insignificant and significant diagnostic discrepancy. The diagnostic discrepancy rates and clinical significance were compared among radiology sections and imaging modalities using the chi-square test. Results: Of 1312 peer reviews, 117 (8.9%) cases had unacceptable diagnoses. Of 462 diagnostic discrepancies, the clinically significant discrepancy was observed in 104 (21.6%) cases. In radiology sections, the unacceptable diagnosis was highest in the musculoskeletal section (21.4%) (p < 0.05), followed by the abdominal section (7.3%) and neuro section (1.3%) (p < 0.05). The proportion of significant discrepancy was higher in the chest section (32.7%) than in the musculoskeletal (19.5%) and abdominal sections (17.1%) (p < 0.05). Regarding modalities, the number of unacceptable diagnoses was higher with MRI (16.2%) than plain radiology (7.8%) (p < 0.05). There was no significant difference in significant discrepancy. Conclusion: Peer review provides the rates of unacceptable diagnosis and clinically significant discrepancy in teleradiology. These rates also differ with subspecialty and modality.

2.
Radiat Prot Dosimetry ; 158(1): 22-7, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23887271

RESUMO

Digital radiography is often performed at a higher dose rate than analogue radiography for image acquisition. The authors measured the Entrance Surface Dose (ESD) of analogue and digital radiography techniques for 14 radiographic examinations from randomly selected medical centres in the central district of Korea. It was that the mean ESD of the digital examinations was 2.84 mGy (range, 0.37-6.38 mGy) and that of the analogue examinations was 1.83 mGy (range, 0.38-4.74 mGy), resulting in a 55.25 % higher ESD for digital technique. Although this survey is not completely representative of Korea, findings of this study indicate a need for closer exposure management in digital radiography to minimise patient dose.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde , Doses de Radiação , Radiografia , Humanos , Intensificação de Imagem Radiográfica , República da Coreia
3.
AJR Am J Roentgenol ; 193(2): W95-9, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19620422

RESUMO

OBJECTIVE: The purpose of this study is to show the importance of aneurysmal appearance of medium-sized bronchi observed at CT in the diagnosis of tuberculosis (TB). CONCLUSION: Aneurysmal appearance of medium-sized bronchi is a CT feature of tuberculosis. In TB-endemic areas, the aneurysmal appearance of medium-sized bronchi at CT may suggest the diagnosis of TB.


Assuntos
Broncografia , Tomografia Computadorizada por Raios X , Tuberculose Pulmonar/diagnóstico por imagem , Adulto , Idoso , Cicatriz/diagnóstico por imagem , Constrição Patológica/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA