Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Microb Pathog ; 158: 105104, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34298126

RESUMO

Anthrax, by Bacillus anthracis, remains a dreadful fatal hazard worldwide. The currently used anthrax vaccines are plagued by numerous issues that limit their widespread use. As an immunization approach targeting both extracellular antigens and toxins of B. anthracis may achieve better sterile immunity, the present investigation designed a bicistronic secretory anti-anthrax DNA vaccine targeting immune response against toxin and cells. The efficacy of the vaccine was compared with monocistronic DNA vaccines and the currently used anthrax vaccine. For this, mice were immunized with the developed vaccine containing pag (encoding protective antigen to block toxin) and eag genes (encoding EA1 to target cells) of B. anthracis through DNA-prime/Protein-boost (D/P) and DNA prime/DNA-boost (D/D) approaches. There was a >2 and > 5 fold increase in specific antibody level by D/D and D/P approaches respectively, on 42nd days post-immunization (dpi). Serum cytokine profiling showed that both Th1 and Th2 immune responses were elicited, with more Th2 responses in D/P strategy. More importantly, challenge with 100 times LD50 of B. anthracis at 42nd dpi exhibited maximum cumulative survival (83.33 %) by bicistronic D/P approach. Remarkably, immunization with EA1 delayed mortality onset in infection. The study forms the first report on complement-dependent bactericidal activity of antiEA1 antibodies. In short, co-immunization of PA and EA1 through the developed bicistronic DNA vaccine would be an effective immunization approach in anthrax vaccination. Further, D/P strategy could enhance vaccine-induced immunity against B. anthracis. Altogether, the study generates certain critical insights having direct applications in next-generation vaccine development against anthrax.


Assuntos
Vacinas contra Antraz , Bacillus anthracis , Vacinas de DNA , Animais , Vacinas contra Antraz/genética , Anticorpos Antibacterianos , Antígenos de Bactérias/genética , Bacillus anthracis/genética , DNA , Imunidade , Camundongos , Camundongos Endogâmicos BALB C , Vacinação , Vacinas de DNA/genética
2.
Biologicals ; 69: 59-65, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33309531

RESUMO

Distressing effects on animal and human health with lethal progression, being used as bioweapon and shared features with non-pathogenic bacteria demands sensitive, specific, safe, cost effective and rapid detection methods for anthrax causing organisms. Conventional microbiology based diagnostics for anthrax are time consuming and need sophisticated equipment, while molecular diagnostics require less time and labor. The Loop mediated isothermal amplification assay (LAMP) is rapid, sensitive and specific assay and requires no specialized equipment. In the present study, we developed a LAMP assay for rapid as well as specific detection of Bacillus anthracis. The optimized assay produced positive results with the Sterne strain and one field isolate of B. anthracis and, negative results with other bacteria of the same and different genera within 2 h. Sensitivity was 500 fg of total DNA of B. anthracis, which was 100 times more sensitive than conventional PCR. The present study also demonstrated that the simple method of total DNA extraction by repeated boiling and freezing will not adversely affect the LAMP results. In conclusion, the optimized LAMP assay is a promising tool for the specific, sensitive, less time-consuming diagnosis for anthrax causing bacteria and also, for detecting the virulence of suspected B. anthracis cultures.


Assuntos
Antraz , Bacillus anthracis , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Animais , Antraz/diagnóstico , Bacillus anthracis/genética , Bacillus anthracis/isolamento & purificação , Humanos , Sensibilidade e Especificidade
3.
Biologicals ; 42(6): 316-21, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25151655

RESUMO

A protective antigen (PA) based coagglutination test was optimized in the present study for the specific and sensitive identification of bacteria causing anthrax in a cost effective and less risky manner. The test showed 100% specificity and sensitivity up to 9 × 10(3) formalinized vegetative cells or 11 ng of PA. The optimized test also detected anthrax toxin directly from the serum as well as blood of anthrax infected animals indicating the potential application for direct diagnosis of anthrax under field conditions.


Assuntos
Antraz/diagnóstico , Antígenos de Bactérias/química , Bacillus anthracis/isolamento & purificação , Toxinas Bacterianas/química , Animais , Coagulação Sanguínea , Western Blotting , Cobaias , Testes de Sensibilidade Microbiana , Reação em Cadeia da Polimerase , Coelhos , Proteínas Recombinantes/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Células-Tronco
4.
Lett Appl Microbiol ; 58(5): 401-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24286182

RESUMO

UNLABELLED: A specific latex agglutination test (LAT) based on anti-PA (protective antigen) antibodies having detection limit of 5 × 10(4) formalin treated Bacillus anthracis cells or 110 ng of PA was optimized in this study. The optimized LAT could detect anthrax toxin in whole blood as well as in serum from the animal models of anthrax infection. The protocol is a simple and promising method for the specific detection of bacteria causing anthrax under routine laboratory, as well as in field, conditions without any special equipments or expertise. SIGNIFICANCE AND IMPACT OF THE STUDY: The article presents the first report of a latex agglutination test for the specific identification of the cultures of bacteria causing anthrax. As the test is targeting one of anthrax toxic protein (PA), this can also be used to determine virulence of suspected organisms. At the same time, the same LAT can be used directly on whole blood or sera samples under field conditions for the specific diagnosis of anthrax.


Assuntos
Antraz/diagnóstico , Antraz/microbiologia , Antígenos de Bactérias/genética , Bacillus anthracis/isolamento & purificação , Toxinas Bacterianas/genética , Testes de Fixação do Látex/métodos , Animais , Antraz/imunologia , Bacillus anthracis/genética , Bacillus cereus , Cobaias , Testes de Fixação do Látex/economia , Limite de Detecção , Coelhos , Proteínas Recombinantes/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA