Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Tomography ; 10(4): 493-503, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38668396

RESUMO

Quantifying an imaging modality's ability to reproduce results is important for establishing its utility. In magnetic resonance spectroscopic imaging (MRSI), new acquisition protocols are regularly introduced which improve upon their precursors with respect to signal-to-noise ratio (SNR), total acquisition duration, and nominal voxel resolution. This study has quantified the within-subject and between-subject reproducibility of one such new protocol (reduced-field-of-view density-weighted concentric ring trajectory (rFOV-DW-CRT) MRSI) by calculating the coefficient of variance of data acquired from a test-retest experiment. The posterior cingulate cortex (PCC) and the right superior corona radiata (SCR) were selected as the regions of interest (ROIs) for grey matter (GM) and white matter (WM), respectively. CVs for between-subject and within-subject were consistently around or below 15% for Glx, tCho, and Myo-Ins, and below 5% for tNAA and tCr.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Reprodutibilidade dos Testes , Masculino , Feminino , Adulto , Imageamento por Ressonância Magnética/métodos , Substância Cinzenta/diagnóstico por imagem , Razão Sinal-Ruído , Espectroscopia de Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Adulto Jovem
2.
ArXiv ; 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-38584615

RESUMO

Recent expert consensus publications have highlighted the issue of poor reproducibility in magnetic resonance spectroscopy (MRS) studies, mainly due to the lack of standardized reporting criteria, which affects their clinical applicability. To combat this, guidelines for minimum reporting standards (MRSinMRS) were introduced to aid journal editors and reviewers in ensuring the comprehensive documentation of essential MRS study parameters. Despite these efforts, the implementation of MRSinMRS standards has been slow, attributed to the diverse nomenclature used by different vendors, the variety of raw MRS data formats, and the absence of appropriate software tools for identifying and reporting necessary parameters. To overcome this obstacle, we have developed the REproducibility Made Easy (REMY) standalone toolbox. REMY software supports a range of MRS data formats from major vendors like GE (p. file), Siemens (twix, .rda, .dcm), Philips (.spar/.sdat), and Bruker (.method), facilitating easy data import and export through a user-friendly interface. REMY employs external libraries such as spec2nii and pymapVBVD to accurately read and process these diverse data formats, ensuring compatibility and ease of use for researchers in generating reproducible MRS research outputs. Users can select and import datasets, choose the appropriate vendor and data format, and then generate an MRSinMRS table, log file, and methodological documents in both Latex and PDF formats. REMY effectively populated key sections of the MRSinMRS table with data from all supported file types. Accurate generation of hardware parameters including field strength, manufacturer, and scanner software version were demonstrated. However, it could not input data for RF coil and additional hardware information due to their absence in the files. For the acquisition section, REMY accurately read and populated fields for the pulse sequence name, nominal voxel size, repetition time (TR), echo time (TE), number of acquisitions/excitations/shots, spectral width [Hz], and number of spectral points, significantly contributing to the completion of the Acquisition fields of the table. Furthermore, REMY generates a boilerplate methods text section for manuscripts.The use of REMY will facilitate more widespread adoption of the MRSinMRS checklist within the MRS community, making it easier to write and report acquisition parameters effectively.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA