Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 205
Filtrar
1.
Eur Radiol ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38958696

RESUMO

OBJECTIVES: To assess radiopalmar ganglion cysts' (RPG) prevalence, morphology, and clinical significance in consecutive patients. MATERIALS AND METHODS: In this retrospective single-center study, two radiologists assessed the presence of RPG and morphologic features on wrist MRI. Radiopalmar complaints and scapholunate ligament (SLL) tears were evaluated. RESULTS: A total of 1053 wrists in 909 patients (mean age 43.4 ± 15.5 years, 602 females) were evaluated. All 308 RPG (Group 1; 308 patients, 29.2%) originated from the palmar capsule; 49 were unilocular, 95 oligolocular, and 164 multilocular; 745 wrists had no RPG (Group 2; 601 patients). One hundred and twenty-six RPG showed internal debris. The mean diameter was 8.5 ± 5.6 mm (cranio-caudal) (1.0-32.9 mm), 8.0 ± 4.1 mm (medio-lateral) (1.0-31.9 mm), and 3.7 ± 2.3 mm (dorso-palmar) (0.4-16.0 mm). 168 RPG showed direct contact with the radial vascular bundle, 24 with the flexor carpi radialis tendon, and 123 with the flexor pollicis longus tendon. In Group 1, significantly more patients showed partial (82/308) [group 2: 45/745, p < 0.001] or complete SLL tears (22/308) [group 2: 20/745, p < 0.001]. Of the patients with RPG, 15.3% presented with radiopalmar complaints. Only the dorso-palmar RPG diameter was positively correlated with radiopalmar complaints (for readers 1 and 2: rs = 0.66/0.61, p < 0.001, respectively), and the best dorso-palmar diameter cut-off value for the probability of having radiopalmar complaints was defined at 3 mm (area under the curve (AUC) 0.74). Other morphologic features were not eligible to discriminate symptomatic patients (AUC range 0.53-0.61). CONCLUSION: This study found RPG in 29% of patients, most of them asymptomatic. However, a dorso-palmar cyst diameter > 3 mm may be clinically significant. CLINICAL RELEVANCE STATEMENT: Radiopalmar ganglion cysts, observed in 29% of wrist MR examinations, are mostly asymptomatic, but those with a larger dorso-palmar diameter may be associated with radiopalmar complaints. KEY POINTS: Radiopalmar ganglion cysts are found in 29% of patients undergoing wrist MRI. Most patients with evidence of radiopalmar ganglion cysts do not show radiopalmar symptoms (85%). A dorso-palmar cyst diameter > 3 mm may be associated with radiopalmar complaints.

3.
Semin Musculoskelet Radiol ; 28(3): 282-292, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38768593

RESUMO

The prevalence of total knee arthroplasty (TKA) is increasing with the aging population. Although long-term results are satisfactory, suspected postoperative complications often require imaging with the implant in place. Advancements in computed tomography (CT), such as tin prefiltration, metal artifact reduction algorithms, dual-energy CT with virtual monoenergetic imaging postprocessing, and the application of cone-beam CT and photon-counting detector CT, allow a better depiction of the tissues adjacent to the metal. For magnetic resonance imaging (MRI), high bandwidth (BW) optimization, the combination of view angle tilting and high BW, as well as multispectral imaging techniques with multiacquisition variable-resonance image combination or slice encoding metal artifact correction, have significantly improved imaging around metal implants, turning MRI into a useful clinical tool for patients with suspected TKA complications.


Assuntos
Artroplastia do Joelho , Humanos , Artroplastia do Joelho/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Prótese do Joelho , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Tomografia Computadorizada por Raios X/métodos
4.
Am J Sports Med ; 52(7): 1820-1825, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38655759

RESUMO

BACKGROUND: Tumor-like distal femoral cortical irregularities (DFCIs) are a frequent incidental finding on knee magnetic resonance imaging (MRI) and are common in young competitive athletes. PURPOSE: To assess and compare the morphology and prevalence of DFCIs in competitive alpine skiers over 48 months during adolescence. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Adolescent competitive alpine skiers were prospectively recruited in 2018 and received bilateral 3-T MRI of the knee at baseline and after 48 months. All MRIs were evaluated for the presence and location of DFCIs, which were marked at 1 of 3 anatomic positions: (1) the femoral attachment of the medial head of the gastrocnemius muscle, (2) the lateral head of the gastrocnemius muscle, or (3) the attachment of the adductor magnus aponeurosis. The size of the DFCI was measured by 2 radiologists independently. The measurements were compared using the Wilcoxon signed-rank test, the interclass correlation coefficient (ICC), and Cohen Kappa. RESULTS: A total of 63 athletes (mean age at follow-up, 19.6 ± 1.2 years; n = 25 female) were included in the study. At baseline, DFCIs were detected in 84 out of 126 knees (67%). At the 48-month follow-up, DFCIs were found in 88 out of 126 knees (70%), with multiple DFCIs in 3 knees and no significant difference between male and female patients (n = 24 male, n = 19 female; P = .71). No significant increase was detected for the number (P = .21) and size of the DFCIs between the baseline and the 48-month follow-up (mean size: baseline, 3.7 ± 0.8 mm; 48-month follow-up: 3.6 ± 0.9 mm; P = .66). The interrater agreement for the mean size measurements of DFCIs was good to excellent (ICC 0.88). CONCLUSION: DFCIs remain a frequent finding on knee MRI in competitive alpine skiers after skeletal maturation and do not disappear during adolescence. The DFCI size was constant in athletes aged between 15 and 19 years. Moreover, DFCIs should not be mistaken for a pathologic finding.


Assuntos
Fêmur , Imageamento por Ressonância Magnética , Esqui , Humanos , Masculino , Feminino , Adolescente , Fêmur/diagnóstico por imagem , Estudos Longitudinais , Adulto Jovem , Estudos Prospectivos , Articulação do Joelho/diagnóstico por imagem , Atletas
5.
Invest Radiol ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38598670

RESUMO

OBJECTIVES: The aim of this study was to qualitatively and quantitatively assess changes in bovine flexor tendons before and after collagen degradation and at different angles in relation to the static B0 field using 3-dimensional ultra-short echo time (UTE) magnetization transfer (MT) imaging within a clinically feasible acquisition time. MATERIALS AND METHODS: Eight bovine flexor tendons were examined at 3 T magnetic resonance imaging including 3-dimensional UTE MT and UTE T2* research application sequences (acquired within 4:04 and 6:38 minutes, respectively) before and after enzyme-induced degradation. The tendons were divided into 2 groups: group 1 (controls) treated with phosphate-buffered saline and group 2 treated with collagenase I to induce collagen degeneration. Magnetic resonance imaging was repeated at 0, 27, 55, and 90 degrees to the B0 field. To calculate quantitative tissue properties, all tendons were semiautomatically segmented, and changes in quantitative UTE T2* and UTE MT ratios (MTRs) were compared at different angles and between groups. In addition to descriptive statistics, the coefficient of variation was calculated to compare UTE MT and UTE T2* imaging. RESULTS: Ultra-short echo time MTR showed a significantly lower coefficient of variation compared with UTE T2* values, indicating a more robust imaging method (UTE MTR 9.64%-11.25%, UTE T2* 18.81%-24.06%, P < 0.001). Both methods showed good performance in detecting degenerated tendons using histopathology as reference standard, with UTE MT imaging having a better area under the curve than UTE T2* mapping (0.918 vs 0.865). Falsely high UTE T2* values were detected at the 55 degrees acquisition angle, whereas UTE MTR values were robust, that is, insensitive to the MAE. CONCLUSIONS: Ultra-short echo time MT imaging is a reliable method for quantifying tendon degeneration that is robust to the MAE and can be acquired in a clinically reasonable time.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38573567

RESUMO

PURPOSE: Three-dimensional (3D) preoperative planning has become the gold standard for orthopedic surgeries, primarily relying on CT-reconstructed 3D models. However, in contrast to standing radiographs, a CT scan is not part of the standard protocol but is usually acquired for preoperative planning purposes only. Additionally, it is costly, exposes the patients to high doses of radiation and is acquired in a non-weight-bearing position. METHODS: In this study, we develop a deep-learning based pipeline to facilitate 3D preoperative planning for high tibial osteotomies, based on 3D models reconstructed from low-dose biplanar standing EOS radiographs. Using digitally reconstructed radiographs, we train networks to localize the clinically required landmarks, separate the two legs in the sagittal radiograph and finally reconstruct the 3D bone model. Finally, we evaluate the accuracy of the reconstructed 3D models for the particular application case of preoperative planning, with the aim of eliminating the need for a CT scan in specific cases, such as high tibial osteotomies. RESULTS: The mean Dice coefficients for the tibial reconstructions were 0.92 and 0.89 for the right and left tibia, respectively. The reconstructed models were successfully used for clinical-grade preoperative planning in a real patient series of 52 cases. The mean differences to ground truth values for mechanical axis and tibial slope were 0.52° and 4.33°, respectively. CONCLUSIONS: We contribute a novel framework for the 2D-3D reconstruction of bone models from biplanar standing EOS radiographs and successfully use them in automated clinical-grade preoperative planning of high tibial osteotomies. However, achieving precise reconstruction and automated measurement of tibial slope remains a significant challenge.

7.
Invest Radiol ; 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38426719

RESUMO

OBJECTIVES: The aim of this study was to clinically validate a fully automated AI model for magnetic resonance imaging (MRI)-based quantifications of lumbar spinal canal stenosis. MATERIALS AND METHODS: This retrospective study included lumbar spine MRI of 100 consecutive clinical patients (56 ± 17 years; 43 females, 57 males) performed on clinical 1.5 (51 examinations) and 3 T MRI scanners (49 examinations) with heterogeneous clinical imaging protocols. The AI model performed segmentations of the thecal sac on axial T2-weighted sequences. Based on these segmentations, the anteroposterior (AP) and mediolateral (ML) distance, and the area of the thecal sac were measured in a fully automated manner. For comparison, 2 fellowship-trained musculoskeletal radiologists performed the same segmentations and measurements independently. Statistics included 1-sample t tests, the intraclass correlation coefficient (ICC), Bland-Altman plots, and Dice coefficients. A P value of <0.05 was considered statistically significant. RESULTS: The average measurements of the AI model, reader 1, and reader 2 were 194 ± 72 mm2, 181 ± 71 mm2, and 179 ± 70 mm2 for thecal sac area, 13 ± 3.3 mm, 12.6 ± 3.3 mm, and 12.6 ± 3.2 mm for AP distance, and 19.5 ± 3.9 mm, 20 ± 4.3 mm, and 19.4 ± 4 mm for ML distance, respectively. Significant differences existed for all pairwise comparisons, besides reader 1 versus AI model for the ML distance and reader 1 versus reader 2 for the AP distance (P = 0.1 and P = 0.21, respectively). The pairwise mean absolute errors among reader 1, reader 2, and the AI model ranged from 0.59 mm and 0.75 mm for the AP distance, from 1.16 mm to 1.37 mm for the ML distance, and from 7.9 mm2 to 15.54 mm2 for the thecal sac area. Pairwise ICCs among reader 1, reader 2, and the AI model ranged from 0.91 and 0.94 for the AP distance and from 0.86 to 0.9 for the ML distance without significant differences. For the thecal sac area, the pairwise ICC between both readers and the AI model of 0.97 each was slightly, but significantly lower than the ICC between reader 1 and reader 2 of 0.99. Similarly, the Dice coefficient and Hausdorff distance between both readers and the AI model were significantly lower than the values between reader 1 and reader 2, overall ranging from 0.93 to 0.95 for the Dice coefficients and 1.1 to 1.44 for the Hausdorff distances. CONCLUSIONS: The investigated AI model is reliable for assessing the AP and the ML thecal sac diameters with human level accuracies. The small differences for measurement and segmentation of the thecal sac area between the AI model and the radiologists are likely within a clinically acceptable range.

8.
Skeletal Radiol ; 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38512363

RESUMO

OBJECTIVES: Knowledge about the long-term outcome of patients with lumbar spondylolysis (LS) is limited. This study assessed the frequency of bone fusion in conservatively treated lumbar spondylolysis with photon counting detector computed tomography. METHODS: Patients with lumbar spondylolysis diagnosed with CT or MRI were prospectively enrolled and underwent CT 5-10 years after initial imaging. Image assessment included evaluation of Meyerding grade, listhesis size, measurement of the lysis gap, and disc integrity on the lysis level. Comparisons were made between bone fusion as the primary endpoint and sex, body mass index, age at diagnosis, follow-up interval, size of listhesis, Meyerding grade, size of the lysis gap, sports activity, and presence of pain. RESULTS: A total of 39 patients (26.0 ± 3.1 years, 15 female) with lumbar spondylolysis on 41 levels were included after a mean follow-up period of 9.1 ± 2.2 years. Nine patients (22.0%, four female) showed complete fusion of the lysis gap. Patients with bone fusion of the lysis gap had a significantly lower Meyerding grade (p = 0.01), smaller size of the listhesis (p = 0.019), and smaller anterior and posterior lysis gap size (p = 0.046 and p = 0.011, respectively). Unilateral lyses showed significantly higher fusion rates than bilateral lyses (40.0% vs. 16.1%, p = 0.01). No statistically significant difference was found for pain at follow-up between patients with and without bone fusion (p = 0.253). CONCLUSION: Bone fusion occurred in about a fifth of conservatively treated lumbar spondylolysis after a follow-up period of 9 years. Factors associated with a successful fusion were a lower Meyerding grade, minimal listhesis, and a small lysis gap.

9.
J Bone Joint Surg Am ; 106(8): 690-699, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38386719

RESUMO

BACKGROUND: The severity of fatty infiltration (FI) predicts the treatment outcome of rotator cuff tears. The purpose of this investigation was to quantitatively analyze supraspinatus (SSP) muscle FI and volume at the initial presentation and after a 3-month minimum of conservative management. We hypothesized that progression of FI could be predicted with initial tear size, FI, and muscle volume. METHODS: Seventy-nine shoulders with rotator cuff tears were prospectively enrolled, and 2 magnetic resonance imaging (MRI) scans with 6-point Dixon sequences were acquired. The fat fraction within the SSP muscle was measured on 3 sagittal slices, and the arithmetic mean was calculated (FI SSP ). Advanced FI SSP was defined as ≥8%, pathological FI SSP was defined as ≥13.5%, and relevant progression was defined as a ≥4.5% increase in FI SSP . Furthermore, muscle volume, tear location, size, and Goutallier grade were evaluated. RESULTS: Fifty-seven shoulders (72.2%) had normal FI SSP , 13 (16.5%) had advanced FI SSP , and 9 (11.4%) had pathological FI SSP at the initial MRI scan. Eleven shoulders (13.9%) showed a ≥4.5% increase in FI SSP at 19.5 ± 14.7 months, and 17 shoulders (21.5%) showed a ≥5-mm 3 loss of volume at 17.8 ± 15.3 months. Five tears (7.1%) with initially normal or advanced FI SSP turned pathological. These tears, compared with tears that were not pathological, had significantly higher initial mediolateral tear size (24.8 compared with 14.3 mm; p = 0.05), less volume (23.5 compared with 34.2 mm 3 ; p = 0.024), more FI SSP (9.6% compared with 5.6%; p = 0.026), and increased progression of FI SSP (8.6% compared with 0.5%; p < 0.001). An initial mediolateral tear size of ≥20 mm yielded a relevant FI SSP progression rate of 81.8% (odds ratio [OR], 19.0; p < 0.001). Progression rates of 72.7% were found for both initial FI SSP of ≥9.9% (OR, 17.5; p < 0.001) and an initial anteroposterior tear size of ≥17 mm (OR, 8.0; p = 0.003). Combining these parameters in a logistic regression analysis led to an area under the receiver operating characteristic curve (AUC) of 0.913. The correlation between FI SSP progression and the time between MRI scans was weak positive (ρ = 0.31). CONCLUSIONS: Three risk factors for relevant FI progression, quantifiable on the initial MRI, were identified: ≥20-mm mediolateral tear size, ≥9.9% FI SSP , and ≥17-mm anteroposterior tear size. These thresholds were associated with a higher risk of tear progression: 19 times higher for ≥20-mm mediolateral tear size, 17.5 times higher for ≥9.9% FI SSP , and 8 times higher for ≥17-mm anteroposterior tear size. The presence of all 3 yielded a 91% chance of ≥4.5% progression of FI SSP within a mean of 19.5 months. LEVEL OF EVIDENCE: Diagnostic Level II . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Lesões do Manguito Rotador , Humanos , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/terapia , Lesões do Manguito Rotador/patologia , Estudos Prospectivos , Manguito Rotador/patologia , Ruptura , Imageamento por Ressonância Magnética/métodos
10.
Invest Radiol ; 59(8): 599-604, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38329824

RESUMO

OBJECTIVES: The aim of this study was to assess the diagnostic value and accuracy of a deep learning (DL)-accelerated fluid attenuated inversion recovery (FLAIR) sequence with fat saturation (FS) in patients with inflammatory synovitis of the knee. MATERIALS AND METHODS: Patients with suspected knee synovitis were retrospectively included between January and September 2023. All patients underwent a 3 T knee magnetic resonance imaging including a DL-accelerated noncontrast FLAIR FS sequence (acquisition time: 1 minute 38 seconds) and a contrast-enhanced (CE) T1-weighted FS sequence (acquisition time: 4 minutes 50 seconds), which served as reference standard. All knees were scored by 2 radiologists using the semiquantitative modified knee synovitis score, effusion synovitis score, and Hoffa inflammation score. Diagnostic confidence, image quality, and image artifacts were rated on separate Likert scales. Wilcoxon signed rank test was used to compare the semiquantitative scores. Interreader and intrareader reproducibility were calculated using Cohen κ. RESULTS: Fifty-five patients (mean age, 52 ± 17 years; 28 females) were included in the study. Twenty-seven patients (49%) had mild to moderate synovitis (synovitis score 6-13), and 17 patients (31%) had severe synovitis (synovitis score >14). No signs of synovitis were detected in 11 patients (20%) (synovitis score <5). Semiquantitative assessment of the whole knee synovitis score showed no significant difference between the DL-accelerated FLAIR sequence and the CE T1-weighted sequence (mean FLAIR score: 10.69 ± 8.83, T1 turbo spin-echo FS: 10.74 ± 10.32; P = 0.521). Both interreader and intrareader reproducibility were excellent (range Cohen κ [0.82-0.96]). CONCLUSIONS: Assessment of inflammatory knee synovitis using a DL-accelerated noncontrast FLAIR FS sequence was feasible and equivalent to CE T1-weighted FS imaging.


Assuntos
Meios de Contraste , Articulação do Joelho , Imageamento por Ressonância Magnética , Sinovite , Humanos , Sinovite/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/patologia , Reprodutibilidade dos Testes , Aprendizado Profundo , Adulto , Aumento da Imagem/métodos , Idoso , Interpretação de Imagem Assistida por Computador/métodos
11.
Insights Imaging ; 15(1): 52, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38365902

RESUMO

OBJECTIVES: To longitudinally assess and correlate the prevalence of superolateral Hoffa fat pad (SHFP) edema with changes in features of the knee extensor mechanism in adolescent competitive alpine skiers over 48 months. METHODS: Competitive alpine skiers were prospectively enrolled in 2018 and underwent bilateral knee MRI at baseline and after 48 months. MRI was assessed for the prevalence of SHFP edema. Features of the knee extensor mechanism were assessed by measuring the trochlear sulcus angle and depth, lateral and medial trochlear inclination, trochlear angle, patella tilt, Insall‒Salvati ratio (ISR), and patellar ligament to lateral trochlear facet (PL-T) distance. Separate logistic regression models were used to calculate the odds ratios between each measurement and the presence of SHFP edema at both time points. RESULTS: Sixty-three athletes were included in the study (mean age 15.3 ± 1.3 years, 25 women). At baseline, 23 knees had SHFP edema, increasing to 34 knees at the 48-month follow-up. At baseline, knees with measurements in the highest quartile for ISR and lowest quartile for trochlear depth and PL-T were 9.3, 5.1, and 7.7 times more likely to show SHFP edema, respectively. At follow-up, these correlations were confirmed and additionally, knees with measurements in the highest quartile for trochlear sulcus angle and the lowest quartile for lateral trochlear inclination were 4.1 and 3.4 times more likely to show SHFP edema. CONCLUSION: An increased prevalence of SHFP edema in competitive alpine skiers during adolescence was associated with persistent high-riding patella, reduced patellar ligament to trochlear distance, and flattened lateral trochlear facet. CRITICAL RELEVANCE STATEMENT: In clinical routine, assessment of the mechanical properties of the knee extensor mechanism, together with anatomical developments during adolescence, may improve the understanding and management of patellofemoral instability. KEY POINTS: • Superolateral Hoffa fat pad (SHFP) edema is a frequent cause of anterolateral knee pain but the role of predisposing factors is still debated. • A higher prevalence of SHFP edema was associated with high-riding patella, reduced patellar ligament to trochlear distance, and flattened lateral trochlear facet. • Understanding of the mechanical interaction and the anatomical development of the knee during adolescence provides further insight into the development of SHFP edema.

12.
Skeletal Radiol ; 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381196

RESUMO

Magnetic resonance imaging (MRI) around metal implants has been challenging due to magnetic susceptibility differences between metal implants and adjacent tissues, resulting in image signal loss, geometric distortion, and loss of fat suppression. These artifacts can compromise the diagnostic accuracy and the evaluation of surrounding anatomical structures. As the prevalence of total joint replacements continues to increase in our aging society, there is a need for proper radiological assessment of tissues around metal implants to aid clinical decision-making in the management of post-operative complaints and complications. Various techniques for reducing metal artifacts in musculoskeletal imaging have been explored in recent years. One approach focuses on improving hardware components. High-density multi-channel radiofrequency (RF) coils, parallel imaging techniques, and gradient warping correction enable signal enhancement, image acquisition acceleration, and geometric distortion minimization. In addition, the use of susceptibility-matched implants and low-field MRI helps to reduce magnetic susceptibility differences. The second approach focuses on metal artifact reduction sequences such as view-angle tilting (VAT) and slice-encoding for metal artifact correction (SEMAC). Iterative reconstruction algorithms, deep learning approaches, and post-processing techniques are used to estimate and correct artifact-related errors in reconstructed images. This article reviews recent developments in clinically applicable metal artifact reduction techniques as well as advances in MR hardware. The review provides a better understanding of the basic principles and techniques, as well as an awareness of their limitations, allowing for a more reasoned application of these methods in clinical settings.

13.
Invest Radiol ; 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38421679

RESUMO

BACKGROUND: Intra-articular injections are routinely used for conservative treatment of knee osteoarthritis (OA). The detailed comparative therapeutic effects of these injections on cartilage tissue are still unclear. OBJECTIVE: The aim of this study was to detect and compare knee cartilage changes after intra-articular injection of glucocorticoid, hyaluronic acid, or platelet-rich plasma (PRP) to placebo using quantitative (T2 and T2* mapping) and morphological magnetic resonance imaging parameters in patients with mild or moderate osteoarthritis. MATERIALS AND METHODS: In a double-blinded, placebo-controlled, single-center trial, knees with mild or moderate osteoarthritis (Kellgren-Lawrence grade 1-3) were randomly assigned to an intra-articular injection with 1 of these substances: glucocorticoid, hyaluronic acid, PRP, or placebo. Cartilage degeneration on baseline and follow-up magnetic resonance imaging scans (after 3 and 12 months) was assessed by 2 readers using quantitative T2 and T2* times (milliseconds) and morphological parameters (modified Outerbridge grading, subchondral bone marrow edema, subchondral cysts, osteophytes). RESULTS: One hundred twenty knees (30 knees per treatment group) were analyzed with a median patient age of 60 years (interquartile range, 54.0-68.0 years). Interreader reliability was good for T2 (ICC, 0.76; IQR, 0.68-0.83) and T2* (ICC, 0.83; IQR, 0.76-0.88) measurements. Morphological parameters showed no significant changes between all groups after 3 and 12 months. T2 mapping after 12 months showed the following significant ( P = 0.001-0.03) changes between groups in 6 of 14 compartments: values after PRP injection decreased compared with glucocorticoid in 4 compartments (complete medial femoral condyle and central part of lateral condyle) and compared with placebo in 2 compartments (anterior and central part of medial tibial plateau); values after glucocorticoid injection decreased compared with placebo in 1 compartment (central part of medial tibial plateau). No significant changes were seen for T2 and T2* times after 3 months and T2* times after 12 months. No correlation was found between T2/T2* times and Kellgren-Lawrence grade, age, body mass index, or pain (Spearman ρ, -0.23 to 0.18). CONCLUSIONS: Platelet-rich plasma injection has a positive long-term effect on cartilage quality in the medial femoral compartment compared to glucocorticoid, resulting in significantly improved T2 values after 12 months. For morphological cartilage parameters, injections with glucocorticoid, PRP, or hyaluronic acid showed no better effect in the short or long term compared with placebo.

14.
Invest Radiol ; 59(8): 545-553, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38214560

RESUMO

OBJECTIVES: The aim of this study was to compare the effectiveness and clinical utility of virtual monoenergetic image (VMI) reconstructions in computed tomography (CT) scans with and without tin prefiltration on a photon-counting detector (PCD) CT system to reduce metal implant artifacts in the postoperative ankle. MATERIALS AND METHODS: This retrospective study included patients with internal fixation of the ankle scanned with and without tin prefiltration (Sn) on a PCD CT scanner between March and October 2023. Virtual monoenergetic images between 60 and 190 keV were reconstructed with a 10-keV increment in a bone kernel for both acquisitions (VMI Sn and VMI Std , respectively). Noise measurements assessed artifact reduction in the most prominent near-metal image distortions and were compared between acquisitions modes as well as between polychromatic images and VMIs. Three readers assessed the visibility of osseous healing along with interpretability and artifact extent for 5 reconstruction levels. RESULTS: A total of 48 patients (21 females, 27 males; mean age, 55.1 ± 19.4 years) were included in this study. Tin-prefiltered acquisitions (n = 30) had a lower artifact level for polychromatic images and VMIs compared with non-tin-prefiltered acquisitions (n = 18; P ≤ 0.043). A significant reduction of metal artifacts was observed for VMI Sn ≥120 keV compared with polychromatic images (hyperdense artifacts: 40.2 HU [interquartile range (IQR) 39.8] vs 14.0 HU [IQR 11.1]; P ≤ 0.01 and hypodense artifacts: 91.2 HU [IQR 82.4] vs 29.7 HU [IQR 39.6]; P ≤ 0.001). For VMI Std , this applied to reconstructions ≥100 keV (hyperdense artifacts: 57.7 HU [IQR 33.4] vs 19.4 HU [IQR 27.6]; P ≤ 0.001 and hypodense artifacts: 106.9 HU [IQR 76.1] vs 57.4 HU [IQR 55.7]; P ≤ 0.021). For visibility of osseous healing, VMI Sn at 120 keV yielded higher ratings compared with polychromatic images ( P ≤ 0.001), whereas image interpretability was rated better ( P = 0.023), and artifact extent was rated lower ( P ≤ 0.001) compared with polychromatic images. CONCLUSIONS: Tin-prefiltered VMI at 120 keV showed a significant reduction in metal artifacts compared with polychromatic images, whereas visibility of osseous healing and image interpretability was improved. Therefore, tin-prefiltration PCD CT with VMI reconstructions may be a helpful complement to postsurgical CT imaging of the ankle in patients with metal implants.


Assuntos
Artefatos , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Adulto , Estanho , Idoso , Fótons , Metais , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia
15.
J Bone Joint Surg Am ; 106(6): 542-552, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38260963

RESUMO

BACKGROUND: If tibiofibular syndesmotic injury is undetected, chronic instability may lead to persistent pain and osteoarthritis. So far, no reliable diagnostic method has been available. The primary objectives of this study were to determine whether defined lesions of the syndesmosis can be correlated with specific tibiofibular joint displacements caused by external rotational torque and to compare the performance of bilateral external torque computed tomography (BET-CT) and arthroscopy. Secondary objectives included an evaluation of the reliability of CT measurements and the suitability of the healthy contralateral ankle as a reference. METHODS: Seven pairs of healthy, cadaveric lower legs were tested and assigned to 2 groups: (1) supination-external rotation (SER) and (2) pronation-external rotation (PER). In the intact state and after each surgical step, an ankle arthroscopy and 3 CT scans were performed. During the scans, the specimens were placed in an external torque device with 2.5, 5.0, and 7.5 Nm of torque applied. RESULTS: The arthroscopic and CT parameters showed significant correlations in all pairwise comparisons. The receiver operating characteristic (ROC) curve analyses yielded the best prediction of syndesmotic instability with the anterior tibiofibular distance on CT, with a sensitivity of 84.1% and a specificity of 95.2% (area under the curve [AUC], 94.8%; 95% confidence interval [CI], 0.916 to 0.979; p < 0.0001) and with the middle tibiofibular distance on arthroscopy, with a sensitivity of 76.2% and specificity of 92.3% (AUC, 91.2%; 95% CI, 0.837 to 0.987; p < 0.0001). Higher torque amounts increased the rate of true-positive results. CONCLUSIONS: BET-CT reliably detects experimental syndesmotic rotational instability, compared with the healthy side, with greater sensitivity and similar specificity compared with the arthroscopic lateral hook test. Translation of these experimental findings to clinical practice remains to be established. LEVEL OF EVIDENCE: Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Articulação do Tornozelo , Tomografia Computadorizada por Raios X , Humanos , Torque , Reprodutibilidade dos Testes , Articulação do Tornozelo/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Cadáver
16.
AJR Am J Roentgenol ; 222(1): e2329950, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37646386

RESUMO

BACKGROUND. Photon-counting detector (PCD) CT could be useful to help address the typically high radiation doses of conventional energy-integrating detector (EID) CT of the lumbar spine. OBJECTIVE. The purpose of our study was to compare PCD CT and EID CT of the lumbar spine, both performed using tin filtration, in terms of radiation dose and image quality. METHODS. This study included a prospective sample of 39 patients (22 men, 17 women; mean age, 27.2 years) who underwent investigational PCD CT of the lumbar spine as part of a separate study and a retrospective sample of 39 patients (22 men, 17 women; mean age, 34.9 years) who underwent clinically indicated EID CT of the lumbar spine. In both groups, all examinations were performed using unenhanced technique with tin prefiltration between June 2022 and January 2023. Patients were matched between groups using age, sex, and BMI. A custom gaussian curve-fitting algorithm was used to automatically calculate image noise, SNR, and CNR for each examination, on the basis of all voxels within the image set. Three radiologists independently reviewed examinations to perform a subjective visual assessment of visualization of trabecular architecture, cortical bone, neuroforaminal content, paraspinal muscles, and intervertebral disk, as well as overall image quality, using a 4-point Likert scale (1 = poor, 4 = excellent). PCD CT and EID CT examinations were compared. RESULTS. Mean CTDIvol was 4.4 ± 1.0 (SD) mGy for PCD CT versus 11.1 ± 1.9 mGy for EID CT (p < .001). Mean size-specific dose estimate (SSDE) was 6.2 ± 1.0 (SD) mGy for PCD CT versus 14.2 ± 1.8 mGy for EID CT (p < .001). PCD CT and EID CT examinations were not significantly different in terms of image noise or SNR (both p > .05). PCD CT, in comparison with EID CT, showed significantly higher CNR (mean ± SD, 33.6 ± 3.3 vs 29.3 ± 4.1; p < .001). For all three readers, the median score for overall image quality was 4 (range, 3-4) for both PCD CT and EID CT. PCD CT and EID CT examinations showed no significant difference in terms of any qualitative measure for any reader (all p > .05). CONCLUSION. PCD CT, in comparison with EID CT, yielded significantly lower radiation dose with preserved image quality. CLINICAL IMPACT. The findings support expanded use of PCD CT for lumbar spine evaluation.


Assuntos
Fótons , Estanho , Masculino , Humanos , Feminino , Adulto , Estudos Prospectivos , Estudos Retrospectivos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação
17.
AJR Am J Roentgenol ; 222(1): e2329765, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37646387

RESUMO

BACKGROUND. Photon-counting detector (PCD) CT may allow lower radiation doses than used for conventional energy-integrating detector (EID) CT, with preserved image quality. OBJECTIVE. The purpose of this study was to compare PCD CT and EID CT, reconstructed with and without a denoising tool, in terms of image quality of the osseous pelvis in a phantom, with attention to low radiation doses. METHODS. A pelvic phantom comprising human bones in acrylic material mimicking soft tissue underwent PCD CT and EID CT at various tube potentials and radiation doses ranging from 0.05 to 5.00 mGy. Additional denoised reconstructions were generated using a commercial tool. Noise was measured in the acrylic material. Two readers performed independent qualitative assessments that entailed determining the denoised EID CT reconstruction with the lowest acceptable dose and then comparing this reference reconstruction with PCD CT reconstructions without and with denoising, using subjective Likert scales. RESULTS. Noise was lower for PCD CT than for EID CT. For instance, at 0.05 mGy and 100 kV with tin filter, noise was 38.4 HU for PCD CT versus 48.8 HU for EID CT. Denoising further reduced noise; for example, for PCD CT at 100 kV with tin filter at 0.25 mGy, noise was 19.9 HU without denoising versus 9.7 HU with denoising. For both readers, lowest acceptable dose for EID CT was 0.10 mGy (total score, 11 of 15 for both readers). Both readers somewhat agreed that PCD CT without denoising at 0.10 mGy (reflecting reference reconstruction dose) was relatively better than the reference reconstruction in terms of osseous structures, artifacts, and image quality. Both readers also somewhat agreed that denoised PCD CT reconstructions at 0.10 mGy and 0.05 mGy (reflecting matched and lower doses, respectively, with respect to reference reconstruction dose) were relatively better than the reference reconstruction for the image quality measures. CONCLUSION. PCD CT showed better-quality images than EID CT when performed at the lowest acceptable radiation dose for EID CT. PCD CT with denoising yielded better-quality images at a dose lower than lowest acceptable dose for EID CT. CLINICAL IMPACT. PCD CT with denoising could facilitate lower radiation doses for pelvic imaging.


Assuntos
Fótons , Estanho , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Doses de Radiação , Pelve
18.
Hip Int ; 34(2): 240-247, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37670460

RESUMO

INTRODUCTION: Chronic hip abductor insufficiency is a rare debilitating condition. In cases refractory to conservative treatment and not amenable to direct repair an augmentation becomes necessary. The preferred salvage method at our institution is augmentation with the anterior third of the gluteus maximus tendon. The aim of this study is to describe the results of 8 patients, treated for painful chronic hip abductor insufficiency with gluteus maximus muscle transfer, after a minimal follow-up of 24 months including a full clinical and MRI evaluation of the hip abductors pre- and postoperatively. METHODS: We retrospectively reviewed a consecutive series of 8 patients who were surgically managed for painful chronic hip abductor insufficiency. All patients had a Trendelenburg sign, impaired muscle strength (M ⩽ 3) as well as a complete avulsion of the hip abductors with marked fatty degeneration (⩾3). Pain levels, muscle strength, functional scores as well as a postoperative MRI was obtained after a minimal follow-up of 24 months. RESULTS: The mean age of the patients was 69 years, mean follow-up was 35 (26-54) months. Pain was significantly reduced postoperatively to VAS 2.5 from VAS 5 (p = 0.046). Trendelenburg sign remained positive in all patients and hip abductor strength did not improve significantly from 2.4 to 3.1 (p = 0.19). Complete healing of the transferred tendon was confirmed by MRI in all patients at last follow-up. CONCLUSIONS: In the setting of painful chronic hip abductor insufficiency refractory to conservative treatment with advanced muscle degeneration without the possibility of a direct reconstruction the gluteus maximus tendon transfer significantly decreased pain. The effect on hip abductor strength and patient-reported functional outcome scores is limited. Despite the modest results it remains our preferred salvage treatment option for lack of better alternatives. Larger studies are necessary to confirm these findings.


Assuntos
Artroplastia de Quadril , Transferência Tendinosa , Humanos , Idoso , Seguimentos , Estudos Retrospectivos , Artroplastia de Quadril/métodos , Tendões/cirurgia , Nádegas/cirurgia , Músculo Esquelético/cirurgia , Dor/etiologia , Dor/cirurgia , Imageamento por Ressonância Magnética
19.
Invest Radiol ; 59(4): 328-336, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37707864

RESUMO

OBJECTIVES: The aim of this study was to quantify and compare fat fraction (FF) and muscle volume between patients with failed and intact rotator cuff (RC) repair as well as a control group with nonsurgical conservative treatment to define FF cutoff values for predicting the outcome of RC repair. MATERIALS AND METHODS: Patients with full-thickness RC tears who received magnetic resonance imaging (MRI) before and after RC repair including a 2-point Dixon sequence were retrospectively screened. Patients with retear of 1 or more tendons diagnosed on MRI (Sugaya IV-V) were enrolled and matched to patients with intact RC repair (Sugaya I-II) and to a third group with conservatively treated RC tears. Two radiologists evaluated morphological features (Cofield, Patte, and Goutallier), as well as the integrity of the RC after repair (Sugaya). Fat fractions were calculated from the 2-point Dixon sequence, and the RC muscles were segmented semiautomatically to calculate FFs and volume for each muscle. Receiver operator characteristics curves were used to determine FF cutoff values that best predict RC retears. RESULTS: In total, 136 patients were enrolled, consisting of 3 groups: 41 patients had a failed RC repair (58 ± 7 years, 16 women), 50 patients matched into the intact RC repair group, and 45 patients were matched into the conservative treatment group. Receiver operator characteristics curves showed reliable preoperative FF cutoff values for predicting retears at 6.0% for the supraspinatus muscle (0.83 area under the curve [AUC]), 7.4% for the infraspinatus muscle (AUC 0.82), and 8.3% for the subscapularis muscle (0.94 AUC). CONCLUSIONS: Preoperative quantitative FF calculated from 2-point Dixon MRI can be used to predict the risk of retear after arthroscopic RC repair with cutoff values between 6% and 8.3%.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Humanos , Feminino , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Manguito Rotador/patologia , Estudos Retrospectivos , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/patologia , Tendões , Imageamento por Ressonância Magnética/métodos , Resultado do Tratamento
20.
Skeletal Radiol ; 53(4): 665-673, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37804455

RESUMO

OBJECTIVE: To compare the image quality of low-dose CT (LD-CT) with tin filtration of the lumbar spine after metal implants to standard clinical CT, and to evaluate the potential for metal artifact and dose reduction. MATERIALS AND METHODS: CT protocols were optimized in a cadaver torso. Seventy-four prospectively included patients with metallic lumbar implants were scanned with both standard CT (120 kV) and tin-filtered LD-CT (Sn140kV). CT dose parameters and qualitative measures (1 = worst,4 = best) were compared. Quantitative measures included noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and the width and attenuation of the most prominent hypodense metal artifact. Standard CT and LD-CT were assessed for imaging findings. RESULTS: Tin-filtered LD-CT was performed with 60% dose saving compared to standard CT (median effective dose 3.22 mSv (quartile 1-3: 2.73-3.49 mSv) versus 8.02 mSv (6.42-9.27 mSv; p < .001). Image quality of CT and tin-filtered low-dose CT was good with excellent depiction of anatomy, while image noise was lower for CT and artifacts were weaker for tin-filtered LD-CT. Quantitative measures also revealed increased noise for tin-filtered low-dose CT (41.5HU), lower SNR (2) and CNR (0.6) compared to CT (32HU,3.55,1.03, respectively) (all p < .001). However, tin-filtered LD-CT performed superior regarding the width and attenuation of hypodense metal artifacts (2.9 mm and -767.5HU for LD-CT vs. 4.1 mm and -937HU for CT; all p < .001). No difference between methods was observed in detection of imaging findings. CONCLUSION: Tin-filtered LD-CT with 60% dose saving performs comparable to standard CT in detection of pathology and surgery related complications after lumbar spinal instrumentation, and shows superior metal artifact reduction.


Assuntos
Estanho , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Tomografia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA