Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Dev Dis ; 9(4)2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35448094

RESUMO

Severe congenital Factor XI (FXI) deficiency (<20% normal activity) can be associated with significant bleeding disorders, and there has been great concern for severe bleeding following cardiac surgery requiring cardiopulmonary bypass (CPB) in this patient population. Over the past four decades remarkably different approaches to this problem have been taken, including the administration of blood volumes of fresh frozen plasma, administration of activated recombinant Factor VII, and diminutive administration of heparin. We describe a case wherein the patient was assessed in the perioperative period with a point-of-care, viscoelastic hemostasis device (ROTEM), with changes in the intrinsic/Factor XII-dependent coagulation pathway determined before, during, and after CPB. Fresh frozen plasma was administered in small amounts (5−7.5 mL/kg) just before surgery began and just before cessation of CPB. Administering fresh frozen plasma to the patient to nearly normalize in vitro ROTEM hemostasis values at times when hemostasis was needed resulted in no important bleeding occurring or need of further transfusion of other blood products. In conclusion, by using small amounts of fresh frozen plasma guided by ROTEM, an evidenced-based, precision medicine approach resulted in optimized patient care and outcome.

2.
Death Stud ; 38(1-5): 145-55, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24524542

RESUMO

The authors investigated if an intervention based on the dual process model (vs. traditional bereavement support) enhanced oscillation between loss- (LO) and restoration-oriented (RO) coping of recently bereaved (2-6 months) spouses/partners. Participants were followed over 12 months. The authors found an increased emphasis over time on RO coping, particularly for women and those who were younger; however, no treatment effect was detected. Although patterns in the data are consistent with the model, the authors conclude that it is difficult for interventions to modify LO, RO, and oscillation unless there is sufficient intervention dosage and tailored to those exclusively engaged in one process.


Assuntos
Adaptação Psicológica , Luto , Cônjuges/psicologia , Viuvez/psicologia , Adaptação Psicológica/classificação , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Psicológicos , Valor Preditivo dos Testes , Distribuição Aleatória , Fatores Sexuais
3.
J Gerontol B Psychol Sci Soc Sci ; 69(1): 85-94, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24056690

RESUMO

OBJECTIVES: Despite increases in social support following widowhood, loneliness is among the most frequently reported challenges of bereavement. This analysis explores the dynamic relationship between social support and loneliness among recently bereaved older adults. METHODS: Using longitudinal data from "Living After Loss" (n = 328), latent growth curve modeling was used to estimate changes in loneliness and social support during the first year and a half of bereavement among older adults aged 50+. RESULTS: Both loneliness and social support declined over the first year and a half of bereavement. Greater social support was associated with lower levels of loneliness overall, but the receipt of social support did not modify one's expression of loneliness over time. Loneliness was more highly correlated with support from friends than family. Together, social support from both friends and family accounted for 36% of the total variance in loneliness. DISCUSSION: There is conceptual and empirical overlap between the concepts of loneliness and social support, but results suggest that loneliness following widowhood cannot be remedied by interventions aimed only at increasing social support. Social support, especially that from friends, appears to be most effective if it is readily accessible and allows the newly bereaved an opportunity to express him/herself.


Assuntos
Luto , Solidão/psicologia , Apoio Social , Viuvez/psicologia , Idoso , Família/psicologia , Feminino , Amigos/psicologia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Testes Psicológicos , Fatores de Tempo
4.
Med Phys ; 33(3): 799-807, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16878582

RESUMO

Determination of mean glandular dose (MGD) to breast tissue is an essential aspect of mammography equipment evaluations and exposure controls. The American College of Radiology (ACR) Quality Control Manual outlines the procedure for MGD determination in screen-film mammography based upon conversions of entrance skin exposures (ESEs) measured with an ionization chamber (IC). The development of digital mammography has increased with the demand for improved object resolution and tissue contrast. This change in image receptor from screen-film to a solid-state detector has led to questions about the applicability of the ACR MGD methodology to digital mammography. This research has validated the applicability of the ACR MGD methodology to digital mammography in the GE digital mammography system Senographe 2000D. MGD was determined using light output measurements from thermoluminescent dosimeters (MGDTL), exposure measurements from an IC (MGD(IC)) and conversion factors from the ACR Mammography Quality Control Manual. MGD(TL) and MGD(IC) data indicate that there is a statistically significant difference between the two measurements with the Senographe 2000D. However, the applicability of the ACR's methodology was validated by calculating MGD at various depths in a 50/50 breast phantom. Additionally, the results of backscatter measurements from the image receptors of both mammography modalities indicate there is a difference (all P values < 0.001) in the radiation backscattered from each image receptor.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Radiometria/métodos , Processamento de Sinais Assistido por Computador/instrumentação , Algoritmos , Mama/patologia , Humanos , Mamografia/instrumentação , Imagens de Fantasmas , Controle de Qualidade , Doses de Radiação , Intensificação de Imagem Radiográfica/instrumentação , Radiometria/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA