Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Lancet Digit Health ; 6(5): e345-e353, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38670743

RESUMO

BACKGROUND: Capsule endoscopy reading is time consuming, and readers are required to maintain attention so as not to miss significant findings. Deep convolutional neural networks can recognise relevant findings, possibly exceeding human performances and reducing the reading time of capsule endoscopy. Our primary aim was to assess the non-inferiority of artificial intelligence (AI)-assisted reading versus standard reading for potentially small bowel bleeding lesions (high P2, moderate P1; Saurin classification) at per-patient analysis. The mean reading time in both reading modalities was evaluated among the secondary endpoints. METHODS: Patients aged 18 years or older with suspected small bowel bleeding (with anaemia with or without melena or haematochezia, and negative bidirectional endoscopy) were prospectively enrolled at 14 European centres. Patients underwent small bowel capsule endoscopy with the Navicam SB system (Ankon, China), which is provided with a deep neural network-based AI system (ProScan) for automatic detection of lesions. Initial reading was performed in standard reading mode. Second blinded reading was performed with AI assistance (the AI operated a first-automated reading, and only AI-selected images were assessed by human readers). The primary endpoint was to assess the non-inferiority of AI-assisted reading versus standard reading in the detection (diagnostic yield) of potentially small bowel bleeding P1 and P2 lesions in a per-patient analysis. This study is registered with ClinicalTrials.gov, NCT04821349. FINDINGS: From Feb 17, 2021 to Dec 29, 2021, 137 patients were prospectively enrolled. 133 patients were included in the final analysis (73 [55%] female, mean age 66·5 years [SD 14·4]; 112 [84%] completed capsule endoscopy). At per-patient analysis, the diagnostic yield of P1 and P2 lesions in AI-assisted reading (98 [73·7%] of 133 lesions) was non-inferior (p<0·0001) and superior (p=0·0213) to standard reading (82 [62·4%] of 133; 95% CI 3·6-19·0). Mean small bowel reading time was 33·7 min (SD 22·9) in standard reading and 3·8 min (3·3) in AI-assisted reading (p<0·0001). INTERPRETATION: AI-assisted reading might provide more accurate and faster detection of clinically relevant small bowel bleeding lesions than standard reading. FUNDING: ANKON Technologies, China and AnX Robotica, USA provided the NaviCam SB system.


Assuntos
Inteligência Artificial , Endoscopia por Cápsula , Hemorragia Gastrointestinal , Intestino Delgado , Humanos , Endoscopia por Cápsula/métodos , Hemorragia Gastrointestinal/diagnóstico , Estudos Prospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Idoso , Adulto , Idoso de 80 Anos ou mais , Redes Neurais de Computação
2.
World J Gastroenterol ; 28(20): 2227-2242, 2022 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-35721886

RESUMO

BACKGROUND: While capsule endoscopy (CE) is the gold standard diagnostic method of detecting small bowel (SB) diseases and disorders, a novel magnetically controlled capsule endoscopy (MCCE) system provides non-invasive evaluation of the gastric mucosal surface, which can be performed without sedation or discomfort. During standard SBCE, passive movement of the CE may cause areas of the complex anatomy of the gastric mucosa to remain unexplored, whereas the precision of MCCE capsule movements inside the stomach promises better visualization of the entire mucosa. AIM: To evaluate the Ankon MCCE system's feasibility, safety, and diagnostic yield in patients with gastric or SB disorders. METHODS: Of outpatients who were referred for SBCE, 284 (male/female: 149/135) were prospectively enrolled and evaluated by MCCE. The stomach was examined in the supine, left, and right lateral decubitus positions without sedation. Next, all patients underwent a complete SBCE study protocol. The gastric mucosa was explored with the Ankon MCCE system with active magnetic control of the capsule endoscope in the stomach, applying three standardized pre-programmed computerized algorithms in combination with manual control of the magnetic movements. RESULTS: The urea breath test revealed Helicobacter pylori positivity in 32.7% of patients. The mean gastric and SB transit times with MCCE were 0 h 47 min 40 s and 3 h 46 min 22 s, respectively. The average total time of upper gastrointestinal MCCE examination was 5 h 48 min 35 s. Active magnetic movement of the Ankon capsule through the pylorus was successful in 41.9% of patients. Overall diagnostic yield for detecting abnormalities in the stomach and SB was 81.9% (68.6% minor; 13.3% major pathologies); 25.8% of abnormalities were in the SB; 74.2% were in the stomach. The diagnostic yield for stomach/SB was 55.9%/12.7% for minor and 4.9%/8.4% for major pathologies. CONCLUSION: MCCE is a feasible, safe diagnostic method for evaluating gastric mucosal lesions and is a promising non-invasive screening tool to decrease morbidity and mortality in upper gastro-intestinal diseases.


Assuntos
Endoscopia por Cápsula , Enteropatias , Cápsulas Endoscópicas , Endoscopia por Cápsula/efeitos adversos , Endoscopia por Cápsula/métodos , Estudos de Viabilidade , Feminino , Mucosa Gástrica , Humanos , Masculino , Estudos Prospectivos
3.
Scand J Gastroenterol ; 55(7): 877-883, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32657195

RESUMO

OBJECTIVES: Linked color imaging (LCI) is a new endoscopic technology that may increase colorectal adenoma detection rate (ADR) and polyp detection rate (PDR) by virtual chromoendoscopy. Aim of the present study was to evaluate the effectiveness of LCI in ADR and PDR compared to the HD white-light colonoscopy (WLC) technique. MATERIALS AND METHODS: Between October 2016 and June 2018, we enrolled consecutive outpatients prospectively. Eligible patients allocated randomly to undergo HD WLC or LCI colonoscopy technique during instrument withdrawal. Each colonoscopy was performed in a single center by the same three expert endoscopists (with expertise more than 5000 colonoscopies). RESULTS: A total of 1278 patients underwent colonoscopy in the study period. ADR and PDR were significantly higher in the LCI group compared to the WLC group (34.4% vs. 26.8%; p = .007; and 53.3% vs 46.4%; p = .023, respectively). Similarly, the mean number of adenomas per patient (MAP) was significantly higher with the LCI than WLC (0.64 vs 0.44, respectively; p = .002). The mean age of patients at the time of colonoscopy was 51.95 years (SD = 13.861) in the LCI group and 51.96 years (SD = 14.028) in the WLC group. No significant differences observed in patient demographic characteristics (there was no difference in gender and age distribution, p = .986), quality of colonoscopy preparation and withdrawal times (WT) between the two groups (WLC and the LCI groups, 493.9 (SD: 143.5) and 514.0 (SD: 139.5) sec, respectively). CONCLUSIONS: According to our results, LCI virtual chromoendoscopic technology was superior compared to conventional HD WLC in detecting colorectal polyps and adenomas.


Assuntos
Adenoma/diagnóstico por imagem , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico por imagem , Adenoma/patologia , Adulto , Idoso , Neoplasias Colorretais/patologia , Feminino , Humanos , Mucosa Intestinal/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
4.
Orv Hetil ; 156(13): 528-31, 2015 Mar 29.
Artigo em Húngaro | MEDLINE | ID: mdl-25796281

RESUMO

INTRODUCTION: Early endoscopic diagnosis and endoscopic therapy are very important in cases of acute gastrointestinal bleeding. Hemospray is an inorganic powder with hemostatic properties recently proposed for the treatment of acute gastrointestinal bleeding. AIM: The aim of the authors was to report the first Hungarian experience obtained with Hemospray in patients with acute gastrointestinal bleeding. METHOD: During a 14-month period 10 acute upper gastrointestinal bleeder patients were treated endoscopically with Hemospray in 11 settings. In 5 patients previous endoscopic hemostatic methods failed and in the remaining 5 patients Hemospray was administrated as a first-line therapy. RESULTS: Primary hemostasis was achieved in 9 of the 10 patients treated with Hemospray. Two patients died during hospitalization (uncontrolled arterial bleeding in one patient and hepatic encephalopathy in the other one patient). Primary hemostasis and hemodynamic stability were achieved in each of the 4 patients who had thrombopenia. CONCLUSIONS: Hemospray as a rescue therapy may ensure primary hemostasis in severe acute gastrointestinal bleeding even in cases with thrombopenia.


Assuntos
Hemorragia Gastrointestinal/terapia , Hemostáticos/uso terapêutico , Minerais/uso terapêutico , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pós , Resultado do Tratamento
5.
World J Gastroenterol ; 19(6): 889-96, 2013 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-23431027

RESUMO

AIM: To investigate the effect of mesalazine granules on small intestinal injury induced by naproxen using capsule endoscopy (CE). METHODS: This was a single center, non-randomized, open-label, uncontrolled pilot study, using the PillCam SB CE system with RAPID 5 software. The Lewis Index Score (LIS) for small bowel injury was investigated to evaluate the severity of mucosal injury. Arthropathy patients with at least one month history of daily naproxen use of 1000 mg and proton pump inhibitor co-therapy were screened. Patients with a minimum LIS of 135 were eligible to enter the 4-wk treatment phase of the study. During this treatment period, 3 × 1000 mg/d mesalazine granules were added to ongoing therapies of 1000 mg/d naproxen and 20 mg/d omeprazole. At the end of the 4-wk combined treatment period, a second small bowel CE was performed to re-evaluate the enteropathy according to the LIS results. The primary objective of this study was to assess the mucosal changes after 4 wk of mesalazine treatment. RESULTS: A total of 18 patients (16 females), ranging in age from 46 to 78 years (mean age 60.3 years) were screened, all had been taking 1000 mg/d naproxen for at least one month. Eight patients were excluded from the mesalazine therapeutic phase of the study for the following reasons: the screening CE showed normal small bowel mucosa or only insignificant damages (LIS < 135) in five patients, the screening esophagogastroduodenoscopy revealed gastric ulcer in one patient, capsule technical failure and incomplete CE due to poor small bowel cleanliness in two patients. Ten patients (9 female, mean age 56.2 years) whose initial LIS reached mild and moderate-to-severe enteropathy grades (between 135 and 790 and ≥ 790) entered the 4-wk therapeutic phase and a repeat CE was performed. When comparing the change in LIS from baseline to end of treatment in all patients, a marked decrease was seen (mean LIS: 1236.4 ± 821.9 vs 925.2 ± 543.4, P = 0.271). Moreover, a significant difference between pre- and post-treatment mean total LIS was detected in 7 patients who had moderate-to-severe enteropathy gradings at the inclusion CE (mean LIS: 1615 ± 672 vs 1064 ± 424, P = 0.033). CONCLUSION: According to the small bowel CE evaluation mesalazine granules significantly attenuated mucosal injuries in patients with moderate-to-severe enteropathies induced by naproxen.


Assuntos
Anti-Inflamatórios não Esteroides/efeitos adversos , Enteropatias/prevenção & controle , Mucosa Intestinal/efeitos dos fármacos , Intestino Delgado/efeitos dos fármacos , Mesalamina/uso terapêutico , Naproxeno/efeitos adversos , Cicatrização/efeitos dos fármacos , Idoso , Endoscopia por Cápsula , Feminino , Humanos , Hungria , Enteropatias/induzido quimicamente , Enteropatias/patologia , Mucosa Intestinal/patologia , Intestino Delgado/patologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
6.
Gastroenterol Res Pract ; 2012: 561207, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23125849

RESUMO

The aim of this study was to investigate the effect of preemptive pantoprazole infusion on early endoscopic findings in patients with acute ulcer bleeding. Records of 333 patients admitted with acute ulcer bleeding were analyzed. Ulcer bleeders were given either 80 mg bolus of pantoprazole followed by continuous infusion of 8 mg per hour or saline infusion until endoscopy. In 93 patients saline infusion whereas in 240 patients bolus plus infusion of pantoprazole was administrated with mean (±SD) durations of 5.45 ± 12.9 hours and 6.9 ± 13.2 hours, respectively (P = 0.29). Actively bleeding ulcers were detected in 46/240 (19.2%) of cases in the pantoprazole group as compared with 23/93 (24.7%) in the saline infusion group (P = 0.26). Different durations of pantoprazole infusion (0-4 hours, >4 hours, and >6 hours) had no significant effect on endoscopic and clinical outcome parameters in duodenal ulcer bleeders. Gastric ulcer bleeders on pantoprazole infusion longer than 4 and 6 hours before endoscopy had actively bleeding ulcers in 4.3% and 5% compared to the 19.5% active bleeding rate in the saline group (P = 0.02 and P = 0.04). Preemptive infusion of high-dose pantoprazole longer than 4 hours before endoscopy decreased the ratio of active bleeding only in gastric but not in duodenal ulcer patients.

7.
Behav Brain Res ; 157(1): 157-65, 2005 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-15617782

RESUMO

Severe perinatal hypoxia-ischemia is an important cause of brain injury in both full-term and premature newborns, with a high risk of future behavioral and neurological deficits. The most commonly used animal model of neonatal hypoxia-ischemia is the unilateral ligation of the common carotid artery followed by exposure to hypoxia in 7-day-old rats. In spite of the wide use of this model, lot of contradictions and discrepancies exist between the results obtained by different laboratories regarding behavioral deficits and there are no data regarding the possible delay of the appearance of neurological reflexes and the time-course of reflex performances following neonatal hypoxic-ischemic injury in rats. In the present study we showed that neonatal hypoxia-ischemia retarded the development of somatic growth and several neurological reflexes (ear twitch, grasping, gait and negative geotaxis). Hypoxic animals also displayed retarded performance in righting, geotaxis and gait reflexes. Although hypoxic pups performed worse in most tests for motor coordination, they reached normal levels by 5 weeks of age except in the footfault test. In the open-field, hypoxic animals were generally more active, except at 3 weeks, when activity of normal pups increased enormously as well. Brain areas were significantly reduced in hypoxic animals, but no close correlation was found with behavioral deficits.


Assuntos
Animais Recém-Nascidos/fisiologia , Comportamento Exploratório/fisiologia , Hipóxia-Isquemia Encefálica/fisiopatologia , Destreza Motora/fisiologia , Reflexo/fisiologia , Animais , Ataxia/etiologia , Ataxia/fisiopatologia , Peso Corporal , Modelos Animais de Doenças , Feminino , Hipóxia-Isquemia Encefálica/complicações , Masculino , Ratos , Ratos Wistar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA