Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Proteome Res ; 23(7): 2386-2396, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38900499

RESUMO

Tyrosine sulfation, an understudied but crucial post-translational modification, cannot be directly detected in conventional nanoflow liquid chromatography-tandem mass spectrometry (nanoLC-MS/MS) due to the extreme sulfate lability. Here, we report the detection of sulfate-retaining fragments from LC-electron capture dissociation (ECD) and nanoLC-electron transfer higher energy collision dissociation (EThcD). Sulfopeptide candidates were identified by Proteome Discoverer and MSFragger analysis of nanoLC-HCD MS/MS data and added to inclusion lists for LC-ECD or nanoLC-EThcD MS/MS. When this approach failed, targeted LC-ECD with fixed m/z isolation windows was performed. For the plasma protein fibrinogen, the known pyroglutamylated sulfopeptide QFPTDYDEGQDDRPK from the beta chain N-terminus was identified despite a complete lack of sulfate-containing fragment ions. The peptide QVGVEHHVEIEYD from the gamma-B chain C-terminus was also identified as sulfated or phosphorylated. This sulfopeptide is not annotated in Uniprot but was previously reported. MSFragger further identified a cysteine-containing peptide from the middle of the gamma chain as sulfated and deamidated. NanoLC-EThcD and LC-ECD MS/MS confirmed the two former sulfopeptides via sulfate-retaining fragment ions, whereas an unexpected fragmentation pattern was observed for the third sulfopeptide candidate. Manual interpretation of the LC-ECD spectrum revealed two additional isobaric identifications: a trisulfide-linked cysteinyl-glycine or a carbamidomethyl-dithiothreiotol covalent adduct. Synthesis of such adducts confirmed the latter identity.


Assuntos
Fibrinogênio , Espectrometria de Massas em Tandem , Tirosina , Tirosina/química , Tirosina/análogos & derivados , Espectrometria de Massas em Tandem/métodos , Fibrinogênio/química , Fibrinogênio/metabolismo , Cromatografia Líquida/métodos , Humanos , Processamento de Proteína Pós-Traducional , Tripsina/química , Tripsina/metabolismo , Sulfatos/química , Sequência de Aminoácidos , Peptídeos/química , Peptídeos/análise , Elétrons
2.
Anal Chem ; 96(21): 8800-8806, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38742421

RESUMO

Negative-ion electron capture dissociation (niECD) is an anion MS/MS technique that provides fragmentation analogous to conventional ECD, including high peptide sequence coverage and retention of labile post-translational modifications (PTMs). niECD has been proposed to be the most efficient for salt-bridged zwitterionic precursor ion structures. Several important PTMs, e.g., sulfation and phosphorylation, are acidic and can, therefore, be challenging to characterize in the positive-ion mode. Furthermore, PTM-friendly techniques, such as ECD, require multiple precursor ion-positive charges. By contrast, singly charged ions, refractory to ECD, are most compatible with niECD. Because electrospray ionization (ESI) typically yields multiply charged ions, we sought to explore matrix-assisted laser desorption/ionization (MALDI) in combination with niECD. However, the requirement for zwitterionic gaseous structures may preclude efficient niECD of MALDI-generated anions. Unexpectedly, we found that niECD of anions from MALDI is not only possible but proceeds with similar or higher efficiency compared with ESI-generated anions. Matrix selection did not appear to have a major effect. With MALDI, niECD is demonstrated up to m/z ∼4300. For such larger analytes, multiple electron captures are observed, resulting in triply charged fragments from singly charged precursor ions. Such charge-increased fragments show improved detectability. Furthermore, significantly improved (∼20-fold signal-to-noise increase) niECD spectral quality is achieved with equivalent sample amounts from MALDI vs ESI. Overall, the reported combination with MALDI significantly boosts the analytical utility of niECD.


Assuntos
Ânions , Elétrons , Peptídeos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Ânions/química , Peptídeos/química , Peptídeos/análise , Sequência de Aminoácidos
3.
J Mass Spectrom ; 55(4): e4475, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31726477

RESUMO

A multimodal workflow for mass spectrometry imaging was developed that combines MALDI imaging with protein identification and quantification by liquid chromatography tandem mass spectrometry (LC-MS/MS). Thin tissue sections were analyzed by MALDI imaging, and the regions of interest (ROI) were identified using a smoothing and edge detection procedure. A midinfrared laser at 3-µm wavelength was used to remove the ROI from the brain tissue section after MALDI mass spectrometry imaging (MALDI MSI). The captured material was processed using a single-pot solid-phase-enhanced sample preparation (SP3) method and analyzed by LC-MS/MS using ion mobility (IM) enhanced data independent acquisition (DIA) to identify and quantify proteins; more than 600 proteins were identified. Using a modified database that included isoform and the post-translational modifications chain, loss of the initial methionine, and acetylation, 14 MALDI MSI peaks were identified. Comparison of the Kyoto Encyclopedia of Genes and Genomes (KEGG) pathways of the identified proteins was achieved through an evolutionary relationships classification system.


Assuntos
Encéfalo/diagnóstico por imagem , Terapia a Laser/métodos , Proteínas/análise , Proteômica/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Animais , Encéfalo/metabolismo , Cromatografia Líquida , Proteínas/metabolismo , Ratos , Espectrometria de Massas em Tandem
4.
Eur J Mass Spectrom (Chichester) ; 25(2): 202-207, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30526027

RESUMO

We have developed a new actuation method for matrix-assisted ionization with good temporal and spatial resolution using piezoelectric cantilever. A strike from the piezoelectric bimorph cantilever on a thin metal foil was used to remove materials deposited on the opposite side facing the mass spectrometer inlet. Highly charged ions of peptides and proteins were generated from dried droplet deposits and sampled into the inlet of the mass spectrometer. A lateral resolution of 1 mm was obtained with the piezoelectric sampling configuration. Singly charged lipids and gangliosides were detected from tissue with piezoelectric matrix-assisted ionization using a silica nanoparticle co-matrix.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA