Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Clin Virol ; 44(1): 86-7, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18845470

RESUMO

BACKGROUND: Many laboratories using R-Mix cell lines inoculate other shell vial cultures to improve the recovery of viruses, and in particular, perform terminal hemadsorption (THad) following 10-14 days of incubation to improve detection of respiratory viruses. We explored the cost-effectiveness and added benefits of THad on conventional shell vial cultures from respiratory samples for laboratories using R-Mix cell lines. OBJECTIVES: To determine if eliminating the practice of THad from conventional shell vial culture when R-Mix cultures are negative, would result in a significant reduction in the number of hemadsorbing respiratory viruses detected. STUDY DESIGN: THad results were retrospectively reviewed for 41,129 respiratory shell vial cultures that were set up concurrently with R-Mix cultures. RESULTS: Greater than 95% of hemadsorbing respiratory viruses were recovered by R-Mix standard protocol within 24h of inoculation, and only 5% were detected by THad at 10-14 days. CONCLUSION: The practice of hemadsorption at days 10-14 for conventional shell vial cultures from respiratory specimens should be discontinued for laboratories using R-Mix due to its low yield, questionable clinical impact of delayed results and additional costs.


Assuntos
Hemadsorção , Infecções Respiratórias/virologia , Viroses/diagnóstico , Vírus/isolamento & purificação , Linhagem Celular , Humanos , Cultura de Vírus/economia , Cultura de Vírus/métodos
3.
J Virol Methods ; 128(1-2): 143-50, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15950293

RESUMO

A quantitative real time PCR assay utilizing an Eclipse minor groove binding hybridization probe was developed to detect and type human herpes 6. A 115 base pair product from the U67 gene was selected for amplification and the assay included a noncompetitive internal control. The probe's melting temperature from the amplified sequence differentiated between HHV6 variants (A and B). In this study, 120 samples (60 spiked and 60 negative) comprising CSF, plasma, and serum were tested at high and medium levels, and near the limit of quantitation. The use of stored standard curves for assay calibration was compared to curves run on each assay, and the stability of liquid frozen versus lyophilized frozen stocks for calibrators and controls was assessed. After 9 months of clinical testing, assay performance was examined to determine the percent positive rate and positive sample reproducibility, as well as to evaluate standard curve stability. We obtained 100% correlation to expected results for positive and negative samples. A stored curve proved easier, more cost effective, and more reliable than running a standard curve on each assay. The use of lyophilized standards contributes substantially to the maintenance of reproducible testing over an extended period of time.


Assuntos
Variação Genética , Herpesvirus Humano 6/classificação , Reação em Cadeia da Polimerase/métodos , Reação em Cadeia da Polimerase/normas , Infecções por Roseolovirus/diagnóstico , Infecções por Roseolovirus/virologia , Sangue/virologia , Calibragem/normas , Líquido Cefalorraquidiano/virologia , Sondas de DNA , Liofilização , Herpesvirus Humano 6/genética , Herpesvirus Humano 6/isolamento & purificação , Humanos , Padrões de Referência , Sensibilidade e Especificidade
4.
Am J Clin Pathol ; 113(5): 714-21, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10800405

RESUMO

Toxoplasma gondii is a cyst-forming parasite of clinical relevance in humans primarily because of the neurologic abnormalities it can cause. In some clinical circumstances, it is desirable to detect the pathogen directly. We modified a commercially available Toxoplasma polymerase chain reaction (PCR) probe capture assay by incorporating uracil N-glycosylase (UNG) to prevent carryover amplicon contamination. In addition, UNG inactivation and DNA denaturation were accomplished chemically to simplify the DNA hybridization to the capture probe. The incorporation of UNG effectively eliminated carryover contamination; the probe capture assay showed a log increase in detection sensitivity compared with standard agarose gel electrophoresis. To assess sensitivity and possible inhibition of amplification, different sample types were spiked with Toxoplasma organisms. After DNA extraction and PCR amplification, a sensitivity of 2 tachyzoites for the assay was determined in buffered saline, cerebrospinal fluid (CSF), serum, and amniotic fluid; 20 tachyzoites for whole blood; and 200 tachyzoites for brain tissue. An additional 20 human serum and CSF samples submitted for Toxoplasma serologic testing were run by the PCR method. Of these, only an IgM-positive CSF sample was PCR positive. The Toxoplasma PCR probe capture assay showed good sensitivity and was not substantially inhibited by several different clinically relevant samples.


Assuntos
DNA Glicosilases , N-Glicosil Hidrolases , Reação em Cadeia da Polimerase/métodos , Toxoplasma/genética , Toxoplasma/isolamento & purificação , Líquido Amniótico/parasitologia , Animais , Anticorpos Antiprotozoários/sangue , Anticorpos Antiprotozoários/líquido cefalorraquidiano , Sangue/parasitologia , Encéfalo/parasitologia , Líquido Cefalorraquidiano/parasitologia , DNA de Protozoário/análise , Sangue Fetal/parasitologia , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/líquido cefalorraquidiano , Imunoglobulina M/sangue , Imunoglobulina M/líquido cefalorraquidiano , Desnaturação de Ácido Nucleico , Sensibilidade e Especificidade , Uracila-DNA Glicosidase
6.
J Clin Microbiol ; 36(11): 3408-9, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9774607

RESUMO

The incorporation of a commercially available coprecipitant into the AMPLICOR enterovirus PCR test specimen preparation enhanced the sensitivity and reproducibility of this assay. Fifty-five previously tested archived cerebrospinal fluids (CSF) specimens were tested in a blind study in duplicate with and without Pellet Paint coprecipitant (Novagen, Inc., Madison, Wis.). Of these specimens, 26 had previously been determined to be positive and 29 had previously been determined to be negative. All previously positive CSF specimens were positive when Pellet Paint was used and only 18 were positive without Pellet Paint. No previously negative specimens were positive on repeat testing with or without Pellet Paint. The background signal was not affected by the addition of Pellet Paint. These data support the utility of a coprecipitant in minimizing false-negative results.


Assuntos
Infecções por Enterovirus/diagnóstico , Infecções por Enterovirus/virologia , Enterovirus/genética , Enterovirus/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Virologia/métodos , Líquido Cefalorraquidiano/virologia , Precipitação Química , Estudos de Avaliação como Assunto , Reações Falso-Negativas , Humanos , Reação em Cadeia da Polimerase/estatística & dados numéricos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Virologia/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA