1.
Clin Chem Lab Med ; 62(7): 1339-1351, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38515344

RESUMO

OBJECTIVES: A reference measurement procedure (RMP) using isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) was developed and validated with the aim of accurately measuring carbamazepine-10,11-epoxide concentrations in human serum and plasma. METHODS: To establish traceability to SI units, the absolute content of the reference material was determined using quantitative nuclear magnetic resonance (qNMR) spectroscopy. As sample preparation a protein precipitation protocol followed by a high dilution step was established. Chromatographic separation from carbamazepine and potential metabolites was achieved using a C18 stationary phase. Selectivity, specificity, matrix effects, precision and accuracy, inter-laboratory equivalence, and uncertainty of measurement were evaluated based on guidelines from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. RESULTS: The RMP demonstrated very good selectivity and specificity, showing no evidence of a matrix effect. This enabled accurate quantification of carbamazepine-epoxide in the concentration range of 0.0400-12.0 µg/mL. The intermediate precision was found to be less than 2.1 %, and the repeatability coefficient of variation (CV) ranged from 1.2 to 1.8 % across all concentration levels. Regarding accuracy, the relative mean bias varied from 1.4 to 2.5 % for native serum levels and from 1.4 to 3.5 % for Li-heparin plasma levels. The measurement uncertainty for single measurements ranged from 1.6 to 2.1 %. CONCLUSIONS: In this study, we introduce a new LC-MS/MS-based candidate RMP for accurately measuring carbamazepine-10,11-epoxide in human serum and plasma. This novel method offers a traceable and dependable platform, making it suitable for standardizing routine assays and assessing clinically relevant samples.


Assuntos
Carbamazepina , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Carbamazepina/sangue , Carbamazepina/análogos & derivados , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Padrões de Referência , Técnicas de Diluição do Indicador , Espectrometria de Massa com Cromatografia Líquida
2.
Clin Chem Lab Med ; 62(7): 1327-1338, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38549258

RESUMO

OBJECTIVES: Primidone is an anticonvulsive drug used in the treatment of epilepsy and essential tremor. It offers beneficial effects in controlling seizures, but its usage is also associated with possible side effects. To ensure optimal therapy, it is crucial to measure its concentration through accurate quantification methods. Therefore, our main goal was to develop and validate a new reference measurement procedure (RMP) for accurately measuring primidone levels in human serum and plasma. METHODS: In our study, we focused on the separation of primidone from both known and unknown interferences using a C18 column. To achieve accurate sample preparation, we developed a protocol involving protein precipitation followed by a high dilution step. The validation of the assay and determination of measurement uncertainty were carried out following guidelines from organizations such as the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. These rigorous validation processes ensure the reliability and accuracy of our method for quantifying primidone levels in human serum and plasma samples. RESULTS: The RMP was shown to be highly selective and specific, with no evidence of matrix interference. It can be used to quantify primidone in the range of 0.150-30.0 µg/mL. Intermediate precision was less than 4.0 %, and repeatability CV ranged from 1.0 to 3.3 % across all concentration levels. The relative mean bias ranged from 0.1 to 3.9 % for native serum levels, and from -2.6 to 2.8 % for lithium-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment were 1.5-4.1 % and 0.9-1.0 %, respectively. CONCLUSIONS: In this study, we introduce an innovative LC-MS/MS-based candidate RMP specifically designed for primidone in human serum and plasma. Our RMP offers a traceable platform, facilitating the standardization of routine assays and enabling the evaluation of clinically relevant samples. With this novel approach, we aim to enhance the accuracy and reliability of primidone measurements, ultimately benefiting the field of clinical research and patient care.


Assuntos
Primidona , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Primidona/sangue , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Padrões de Referência , Reprodutibilidade dos Testes , Técnicas de Diluição do Indicador , Limite de Detecção , Anticonvulsivantes/sangue , Espectrometria de Massa com Cromatografia Líquida
3.
Clin Chem Lab Med ; 62(7): 1314-1326, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38407268

RESUMO

OBJECTIVES: Phenobarbital serves as an antiepileptic drug (AED) and finds application in the treatment of epilepsy either as monotherapy or adjunctive therapy. This drug exhibits various pharmacodynamic properties that account for its beneficial effects as well as potential side effects. Accurate measurement of its concentration is critical for optimizing AED therapy through appropriate dose adjustments. Therefore, our objective was to develop and validate a new reference measurement procedure (RMP) for the accurate quantification of phenobarbital levels in human serum and plasma. METHODS: A sample preparation protocol based on protein precipitation followed by a high dilution step was established in combination with a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method using a C8 column to separate target analytes from known and unknown interferences. Assay validation and determination of measurement uncertainty were performed based on current guidelines. Selectivity and Specificity were assessed using spiked serum and plasma samples; to investigate possible matrix effects (MEs) a post-column infusion experiment and a comparison of standard line slopes was performed. Precision and accuracy were determined within a multiday precision experiment. RESULTS: The RMP was shown to be highly selective and specific, with no evidence of matrix interferences. It can be used to quantify phenobarbital in the range of 1.92 to 72.0 µg/mL. Intermediate precision was less than 3.2 %, and repeatability coefficient of variation (CV) ranged from 1.3 to 2.0 % across all concentration levels. The relative mean bias ranged from -3.0 to -0.7 % for native serum levels, and from -2.8 to 0.8 % for Li-heparin plasma levels. The measurement uncertainties (k=1) for single measurements and target value assignment were 1.9 to 3.3 % and 0.9 to 1.6 %, respectively. CONCLUSIONS: A novel LC-MS/MS-based candidate RMP for the quantification of phenobarbital in human serum and plasma is presented which can be used for the standardization of routine assays and the evaluation of clinically relevant samples.


Assuntos
Fenobarbital , Espectrometria de Massas em Tandem , Humanos , Fenobarbital/sangue , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Anticonvulsivantes/sangue , Padrões de Referência , Análise Química do Sangue/métodos , Análise Química do Sangue/normas , Técnicas de Diluição do Indicador , Espectrometria de Massa com Cromatografia Líquida
4.
Clin Chem Lab Med ; 62(7): 1288-1300, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38105272

RESUMO

OBJECTIVES: To describe and validate an isotope dilution-liquid chromatograph-tandem mass spectrometry (ID-LC-MS/MS) based reference measurement procedure (RMP) for zonisamide to accurately measure serum and plasma concentrations. METHODS: Quantitative nuclear magnetic resonance (qNMR) spectroscopy was employed to determine the absolute content of the reference material used in order to establish traceability to SI units. Separation of zonisamide from known or unknown interferences was performed on a C8 column. For sample preparation a protocol based on protein precipitation in combination with a high dilution step was established. Assay validation and determination of measurement uncertainty were performed based on guidelines from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the expression of uncertainty in measurement. RESULTS: The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of zonisamide within the range of 1.50-60.0 µg/mL. Intermediate precision was <1.4 % and repeatability CV ranged from 0.7 to 1.2 % over all concentration levels. The relative mean bias ranged from 0.0 to 0.8 % for native serum levels and from 0.2 to 2.0 % for Li-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment ranged from 1.1 to 1.4 % and 0.8-1.0 %, respectively. CONCLUSIONS: We present a novel LC-MS/MS-based candidate RMP for zonisamide in human serum and plasma which provides a traceable and reliable platform for the standardization of routine assays and evaluation of clinically relevant samples.


Assuntos
Isoxazóis , Espectrometria de Massas em Tandem , Zonisamida , Humanos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Zonisamida/sangue , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Isoxazóis/sangue , Padrões de Referência , Técnicas de Diluição do Indicador , Análise Química do Sangue/métodos , Análise Química do Sangue/normas , Espectrometria de Massa com Cromatografia Líquida
5.
Clin Chem Lab Med ; 2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38095314

RESUMO

OBJECTIVES: An isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) was developed and validated to accurately measure serum and plasma concentrations of carbamazepine. METHODS: Quantitative nuclear magnetic resonance (qNMR) spectroscopy was used to determine the absolute content of the reference material, ensuring its traceability to SI units. The separation of carbamazepine from potential interferences, whether known or unknown, was achieved using a C18 column. A protein precipitation protocol followed by a high dilution step was established for sample preparation. Assay validation and determination of measurement uncertainty were performed in accordance with the guidelines of the Clinical and Laboratory Standards Institute, the International Conference on Harmonization (ICH), and the Guide to the Expression of Uncertainty in Measurement (GUM). In order to demonstrate equivalence to the already existing RMP a method comparison study was performed. RESULTS: The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of carbamazepine within the range of 0.800-18.0 µg/mL. Intermediate precision and repeatability (n=60 measurements) was found to be <1.6 % and <1.3 % over all concentration levels and independent from the matrix. The relative mean bias ranged from -0.1 to 0.6 % for native serum and from -0.3 to -0.1 % for Li-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment were found to be <1.8 % and <1.3 %, respectively. Method comparison showed a good agreement between the Joint Committee of Traceability in Laboratory Medicine (JCTLM) listed RMP and the candidate RMP resulting in a Passing-Bablok regression equation with a slope of 1.01 and an intercept of -0.01. The bias in the patient cohort was found to be 0.9 %. CONCLUSIONS: We present a novel LC-MS/MS-based candidate RMP for carbamazepine in human serum and plasma which provides a traceable and reliable platform for the standardization of routine assays and evaluation of clinically relevant samples.

6.
Clin Chem Lab Med ; 61(11): 1942-1954, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37466369

RESUMO

OBJECTIVES: Topiramate is an antiepileptic drug (AED) used for the monotherapy or adjunctive treatment of epilepsy and for the prophylaxis of migraine. It has several pharmacodynamic properties that contribute to both its clinically useful properties and observed adverse effects. Accurate measurement of its concentration is therefore essential for dose adjustment/optimisation of AED therapy. Our aim was to develop and validate a novel reference measurement procedure (RMP) for the quantification of topiramate in human serum and plasma. METHODS: An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method in combination with a protein-precipitation-based sample preparation allows for quantification of topiramate in human serum and plasma. To assure traceability to SI units, quantitative nuclear magnetic resonance (qNMR) was applied to characterize the reference material used as primary calibrator for this RMP. Matrix effects were determined by performing a post-column infusion experiment and comparing standard line slopes. Accuracy and precision was evaluated performing an extensive five day precision experiment and measurement uncertainty was evaluated according Guide to the Expression of Uncertainty in Measurement (GUM). RESULTS: The method enabled topiramate quantification within the range of 1.20-36.0 µg/mL without interference from structurally related compounds and no evidence of a matrix effect. Intermediate precision was ≤3.2 % and repeatability was 1.4-2.5 % across all concentration levels. The relative mean bias was -0.3 to 3.5 %. Expanded measurement uncertainties for target value assignment (n=6) were found to be ≤2.9 % (k=2) independent of the concentration level and the nature of the sample. CONCLUSIONS: In human serum and plasma, the RMP demonstrated high analytical performance for topiramate quantification and fulfilled the requirements on measurement uncertainty. Traceability to SI units was established by qNMR content determination of the topiramate, which was used for direct calibration of the RMP. This RMP is, therefore, fit for purpose for routine assay standardization and clinical sample evaluation.


Assuntos
Plasma , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Topiramato , Espectrometria de Massas em Tandem/métodos , Técnicas de Diluição do Indicador , Anticonvulsivantes , Isótopos , Padrões de Referência
7.
Clin Chem Lab Med ; 61(11): 1967-1977, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37011038

RESUMO

OBJECTIVES: To develop an isotope dilution-liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based candidate reference measurement procedure (RMP) for levetiracetam quantification in human serum and plasma. METHODS: Quantitative nuclear magnetic resonance spectroscopy (qNMR) was used to characterize the RMP material to ensure traceability to SI units. To quantify levetiracetam, an LC-MS/MS method was optimized using a C8 column for chromatographic separation following protein-precipitation-based sample preparation. Spiked matrix samples of serum and plasma were used to test selectivity and specificity. Matrix effects were determined by performing a post-column infusion experiment and comparing standard line slopes. Precision and accuracy were evaluated over 5 days. Measurement uncertainty was evaluated according to the Guide to the Expression of Uncertainty in Measurement (GUM). RESULTS: The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of levetiracetam within the range of 1.53-90.0 µg/mL. Intermediate precision was <2.2% and repeatability was 1.1-1.7% across all concentrations. The relative mean bias ranged from -2.5% to -0.3% across all levels and matrices within the measuring range. Diluted samples were found with a mean bias ranging from -0.1 to 2.9%. The predefined acceptance criterion for measurement uncertainty was met and determined for individual measurements independently of the concentration level and sample type to be ≤4.0% (k=2). CONCLUSIONS: We present a novel LC-MS/MS)-based candidate RMP for levetiracetam in human serum and plasma. Its expanded measurement uncertainty of ≤4.0% meets the clinical needs in levetiracetam monitoring. Utilizing qNMR to characterize levetiracetam reference materials allowed metrological traceability to SI units.


Assuntos
Isótopos , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Levetiracetam , Reprodutibilidade dos Testes , Técnicas de Diluição do Indicador , Padrões de Referência
8.
Clin Chem Lab Med ; 61(11): 1902-1916, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36952682

RESUMO

OBJECTIVES: An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC MS/MS)-based candidate reference measurement procedure (RMP) for aldosterone quantification in human serum and plasma is presented. METHODS: The material used in this RMP was characterized by quantitative nuclear magnetic resonance (qNMR) to assure traceability to SI Units. For liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis a two-dimensional heart cut LC approach, in combination with an optimal supported liquid extraction protocol, was established for the accurate analysis of aldosterone in human serum and plasma in order to minimize matrix effects and avoid the co-elution of interferences. Assay validation was performed according to current guidelines. Selectivity and specificity were assessed using spiked serum; potential matrix effects were examined by a post column infusion experiment and the comparison of standard line slopes. An extensive protocol over 5 days was applied to determine precision, accuracy and trueness. Measurement uncertainty was evaluated according to the Guide to the Expression of Uncertainty in Measurement (GUM), for which three individual sample preparations were performed on at least two different days. RESULTS: The RMP allowed aldosterone quantification within the range of 20-1,200 pg/mL without interference from structurally-related compounds and no evidence of matrix effects. Intermediate precision was ≤4.7% and repeatability was 2.8-3.7% for all analyte concentrations. The bias ranged between -2.2 and 0.5% for all levels and matrices. Total measurement uncertainties for target value assignment (n=6) were found to be ≤2.3%; expanded uncertainties were ≤4.6% (k=2) for all levels. CONCLUSIONS: The RMP showed high analytical performance for aldosterone quantification in human serum and plasma. The traceability to SI units was established by qNMR content determination of aldosterone, which was utilized for direct calibration of the RMP. Thus, this candidate RMP is suitable for routine assay standardization and evaluation of clinical samples.


Assuntos
Aldosterona , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Isótopos , Técnicas de Diluição do Indicador , Padrões de Referência
9.
Clin Chem Lab Med ; 61(11): 1917-1929, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36788118

RESUMO

OBJECTIVES: To develop an isotope dilution-liquid chromatography-tandem mass spectrometry-(ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for quantification of methotrexate in human serum and plasma. METHODS: Quantitative nuclear magnetic resonance (qNMR) was used to determine absolute methotrexate content in the standard. Separation was achieved on a biphenyl reversed-phase analytical column with mobile phases based on water and acetonitrile, both containing 0.1% formic acid. Sample preparation included protein precipitation in combination with high sample dilution, and method validation according to current guidelines. The following were assessed: selectivity (using analyte-spiked samples, and relevant structural-related compounds and interferences); specificity and matrix effects (via post-column infusion and comparison of human matrix vs. neat samples); precision and accuracy (in a five-day validation analysis). RMP results were compared between two independent laboratories. Measurement uncertainty was evaluated according to current guidelines. RESULTS: The RMP separated methotrexate from potentially interfering compounds and enabled measurement over a calibration range of 7.200-5,700 ng/mL (0.01584-12.54 µmol/L), with no evidence of matrix effects. All pre-defined acceptance criteria were met; intermediate precision was ≤4.3% and repeatability 1.5-2.1% for all analyte concentrations. Bias was -3.0 to 2.1% for samples within the measuring range and 0.8-4.5% for diluted samples, independent of the sample matrix. RMP results equivalence was demonstrated between two independent laboratories (Pearson correlation coefficient 0.997). Expanded measurement uncertainty of target value-assigned samples was ≤3.4%. CONCLUSIONS: This ID-LC-MS/MS-based approach provides a candidate RMP for methotrexate quantification. Traceability of methotrexate standard and the LC-MS/MS platform were assured by qNMR assessment and extensive method validation.


Assuntos
Metotrexato , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Técnicas de Diluição do Indicador , Isótopos , Padrões de Referência , Reprodutibilidade dos Testes
10.
Clin Chem Lab Med ; 61(11): 1930-1941, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36785916

RESUMO

OBJECTIVES: We developed an isotope dilution (ID)-liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based candidate reference measurement procedure (RMP) for lamotrigine in human serum and plasma, using quantitative nuclear magnetic resonance-characterized reference standards to ensure traceability to the International System of Units. METHODS: A sample preparation protocol based on protein precipitation combined with LC-MS/MS analysis using a C18 column for chromatographic separation was established for the quantification of lamotrigine in human serum and plasma. Assay validation was performed according to current guidelines. Spiked serum and plasma samples were used to assess selectivity and specificity; a post-column infusion experiment and comparison of standard line slopes were performed to ascertain possible matrix effects. Precision and accuracy were determined in a 5 days validation experiment. Measurement uncertainty was determined per the Guide to the Expression of Uncertainty in Measurement. RESULTS: The method allowed the quantification of lamotrigine in serum and plasma in a range of 0.600-24.0 µg/mL without any observable matrix effects. The relative mean bias (n=6) ranged from 1.7 to 3.7%; intermediate precision, including variances in between-day, -calibration, and -injection, was ≤2.4%, independent of the level and matrix. Total measurement uncertainty for a single measurement was ≤2.6%; expanded uncertainty was ≤5.2% (coverage factor k=2). CONCLUSIONS: This candidate RMP based on ID-LC-MS/MS provides a traceable and reliable platform for the standardization of routine assays and the evaluation of clinical samples.


Assuntos
Anticonvulsivantes , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Lamotrigina , Espectrometria de Massas em Tandem/métodos , Isótopos , Padrões de Referência
11.
Clin Chem Lab Med ; 61(11): 1890-1901, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36622091

RESUMO

For molecules that can be well described metrologically in the sense of the definition of measurands, and which can also be recorded analytically as individual substances, reference measurement service traceability to a metrologically sound foundation is a necessity. The establishment of traceability chains must be initiated by National Metrology Institutes (NMIs) according to applicable standards; they are at the top and leading position in this concept. If NMIs are not in the position to take up this task, alternative approaches must be sought. Traceability initiatives established by in vitro device industry or academia must meet the quality standards of NMIs. Adherence to International Organization for Standardization (ISO) procedure 15193 must be a matter of course for the establishment of reference measurement procedures (RMPs). Certified reference material (CRM) characterization must be thorough, e.g., by the application of quantitative nuclear magnetic resonance measurements and by adherence to ISO 15194. Both for RMPs and CRMs Joint Committee for Traceability in Laboratory Medicine (JCTLM) listing must be the ultimate goal. Results must be shared in a transparent manner to allow other stakeholders including NMIs to reproduce and disseminate the reference measurement procedures.


Assuntos
Laboratórios , Humanos , Padrões de Referência
12.
Clin Chem Lab Med ; 61(11): 1955-1966, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36689915

RESUMO

OBJECTIVES: To describe and validate a reference measurement procedure (RMP) for gabapentin, employing quantitative nuclear magnetic resonance (qNMR) spectroscopy to determine the absolute content of the standard materials in combination with isotope dilution-liquid chromatograph-tandem mass spectrometry (ID-LC-MS/MS) to accurately measure serum and plasma concentrations. METHODS: A sample preparation protocol based on protein precipitation in combination with LC-MS/MS analysis using a C8 column for chromatographic separation was established for the quantification of gabapentin. Assay validation and determination of measurement uncertainty were performed according to guidance from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the expression of uncertainty in measurement. ID-LC-MS/MS parameters evaluated included selectivity, specificity, matrix effects, precision and accuracy, inter-laboratory equivalence, and uncertainty of measurement. RESULTS: The use of qNMR provided traceability to International System (SI) units. The chromatographic assay was highly selective, allowing baseline separation of gabapentin and the gabapentin-lactam impurity, without observable matrix effects. Variability between injections, preparations, calibrations, and days (intermediate precision) was <2.3%, independent of the matrix, while the coefficient of variation for repeatability was 0.9-2.0% across all concentration levels. The relative mean bias ranged from -0.8-1.0% for serum and plasma samples. Passing-Bablok regression analysis indicated very good inter-laboratory agreement; the slope was 1.00 (95% confidence interval [CI] 0.98 to 1.03) and the intercept was -0.05 (95% CI -0.14 to 0.03). Pearson's correlation coefficient was ≥0.996. Expanded measurement uncertainties for single measurements were found to be ≤5.0% (k=2). CONCLUSIONS: This analytical protocol for gabapentin, utilizing traceable and selective qNMR and ID-LC-MS/MS techniques, allows for the standardization of routine tests and the reliable evaluation of clinical samples.


Assuntos
Plasma , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Gabapentina , Espectrometria de Massas em Tandem/métodos , Técnicas de Diluição do Indicador , Isótopos , Padrões de Referência
13.
Sci Rep ; 12(1): 3014, 2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-35194108

RESUMO

Vitamin D is an important parameter, in serum/plasma based diagnostic analysis, for the determination of optimal regulation of calcium and phosphate homeostases in the human body, vital for the monitoring/progression of osteomalacia and rickets. Particularly, the quantification of 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 24R,25-dihydroxyvitamin D in blood is an excellent indicator for the vitamin D status of a patient. For this purpose, LC-MS/MS methods, based on appropriate vitamin D reference standards, are considered to be 'gold standard' for such measurements. We have utilized quantitative NMR spectroscopy to determine the absolute content of these molecules, available as non-certified chemicals, and have determined the stability of these callibrators in borderline polar solvents at room temperature. We have observed significant isomerization of the analytes, which can play a big role in quantification of these analytes by hyphenated LC and GC analytical techniques. Appropriate explanations are given for the observation of new impurities with time in solution phase. The spin system selected for quantitation was determined using relevant 1D and 2D NMR pulse sequences. The advantage of the qNMR approach is that it is based on the quantification of atoms rather than molecular properties (e.g., quantitation by LC/UV, GC, etc.). Since the signals in an NMR spectrum are different nuclear spin-systems dispersed precisely in a magnetic environment, with the intensity being directly proportional to the amount of a particular type of nuclear spin, this technique delivers unparalleled information about the chemical structure and the absolute content.

14.
J Appl Lab Med ; 7(2): 503-514, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34662384

RESUMO

BACKGROUND: Androstenedione (ASD) levels can aid diagnosis of hyperandrogenism together with other clinical/laboratory findings. We evaluated performance of the new, automated Elecsys® ASD assay vs an ASD isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) reference measurement procedure and determined reference ranges. METHODS: Repeatability/intermediate precision were assessed using 3 control levels and 5 human serum pools (n = 75 each; Clinical and Laboratory Standards Institute EP05-A3). Method comparisons vs commercially available immunoassays [IMMULITE ASD (Siemens) and LIAISON ASD (DiaSorin)] and an ID-LC-MS/MS measurement procedure method were conducted using 421 serum samples; Passing-Bablok regression and Pearson's correlation coefficients were calculated. Reference ranges and distribution of values associated with polycystic ovary syndrome (PCOS) were determined in five clinical cohorts using samples from several sites/vendors. RESULTS: Repeatability/intermediate precision coefficients of variation across all sites were 2.01% to 3.91% and 2.43% to 4.30%, respectively (mean ASD: 7.80-34.7 nmol/L). The Elecsys ASD assay showed poor agreement with IMMULITE ASD (slope = 0.459; r = 0.856; n = 320), fair agreement with LIAISON ASD (slope = 0.625; r = 0.984; n = 327), and very good agreement with ID-LC-MS/MS (slope = 1.040; r = 0.996; n = 332). Reference ranges (2.5th-97.5th percentiles) were: children (≤8 years; n = 140), <0.525 to 1.81 nmol/L; males (≥18 years; n = 138), 0.979 to 5.32 nmol/L; and postmenopausal females (n = 140), 0.654 to 3.74 nmol/L. Reference range (5th-95th percentiles) for females with fertile cycle (≥18 years; n = 84) was 1.71 to 4.58 nmol/L. The distribution of values (2.5th-97.5th percentiles) in females with PCOS (n = 125) was 2.26 to 12.1 nmol/L. CONCLUSIONS: Elecsys ASD assay demonstrated excellent precision and very good agreement with ID-LC-MS/MS. Reference ranges were established to support results interpretation in routine practice.


Assuntos
Androstenodiona , Síndrome do Ovário Policístico , Criança , Cromatografia Líquida/métodos , Feminino , Humanos , Imunoensaio/métodos , Masculino , Valores de Referência , Espectrometria de Massas em Tandem/métodos
15.
RSC Adv ; 11(38): 23627-23630, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35479823

RESUMO

Quantitative NMR spectroscopy has been utilized to calculate the absolute content (g g-1) of aldosterone, which is necessary for electrolyte balance and blood pressure regulation, in commercially available materials. Explanations have been provided for many signals observed in the 1HNMR spectrum, false interpretation of which can have significant effects if such a value is utilized for the primary calibrators in ID-LC-MS/MS ('gold standard') reference methods in clinical chemistry.

16.
Clin Mass Spectrom ; 16: 1-10, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34820514

RESUMO

The accurate measurement of androstenedione in human serum and plasma is required for steroid profiling to assure the appropriate diagnosis and differential diagnosis of hyperandrogenism. In this work, we introduce an isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) candidate reference measurement procedure for the quantification of androstenedione in human serum and plasma. The performance of the procedure enables its use in the evaluation and standardization of routine assays and for the evaluation of patient samples to ensure the traceability of individual patient results. As the primary standard, a certified reference material from NMIA (National Measurement Institute, Australia) was used. Additionally, a quantitative nuclear magnetic resonance (qNMR) method was developed for the value assignment of the primary reference material, which ensures the direct traceability to SI units, as well as the independence from the availability of reference materials. 13C3-labeled androstenedione was used as the internal standard. The introduced method allows the measurement of androstenedione in the range of 0.05-12 ng/mL, and the assay imprecision was found to be <2% between 5 and 12 ng/mL, 3.5% at 1.5 ng/mL, and 5.2% at 0.05 ng/mL, with an accuracy of 95-105% for the serum and 91-103% for the plasma matrix. The transferability to a second laboratory was validated by method comparison based on 112 patient samples. The comparison of the results obtained from the presented method and an LC-MS/MS routine assay, using 150 native patient samples, showed a good correlation with a bias of the routine method of ≤4.0%.

17.
Clin Biochem ; 82: 73-84, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31770523

RESUMO

An isotope dilution LC-MS/MS based candidate reference measurement procedure for the quantification of cyclosporine A, tacrolimus, sirolimus and everolimus in human whole blood is presented to be used for evaluation and standardization of routine assays applied for therapeutic drug monitoring. The assay allows baseline separation of the four immunosuppressive drugs within a total runtime of 9 minutes using a C4 reversed phase column. Sample preparation is based on protein precipitation with zinc sulphate followed by purification with solid phase extraction. Reference materials used in this reference measurement procedure were characterized by qNMR and an absolute content of analytes calculated to guarantee traceability to SI units. As internal standards the corresponding deuterated and 13C-labelled analytes were used. The method allows the measurement of cyclosporine A in the range of 5 ng/mL to 2100 ng/mL; tacrolimus, sirolimus and everolimus were analysed in the range of 0.25 ng/mL to 50 ng/mL. Imprecision for inter-day measurements were found to be ≤3.5% for cyclosporine A and ≤4.4% for tacrolimus, sirolimus and everolimus. Accuracy was found to be within 101% and 108% for cyclosporine A and between 95% and 104% for the macrolide compounds. The uncertainty was evaluated according to the GUM. Expanded measurement uncertainties were found to be ≤7.2% for cyclosporine A, ≤6.8% for tacrolimus, ≤9.0% for sirolimus and ≤8.9% for everolimus (k = 2).


Assuntos
Isótopos de Carbono/química , Ciclosporina/sangue , Testes Diagnósticos de Rotina/métodos , Monitoramento de Medicamentos/métodos , Everolimo/sangue , Imunossupressores/sangue , Sirolimo/sangue , Tacrolimo/sangue , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Confiabilidade dos Dados , Testes Diagnósticos de Rotina/normas , Monitoramento de Medicamentos/normas , Humanos , Técnicas de Diluição do Indicador , Padrões de Referência , Sensibilidade e Especificidade , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/normas
18.
Oncotarget ; 9(39): 25661-25680, 2018 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-29876015

RESUMO

Destruxins, secondary metabolites of entomopathogenic fungi, exert a wide variety of interesting characteristics ranging from antiviral to anticancer effects. Although their mode of action was evaluated previously, the molecular mechanisms of resistance development are unknown. Hence, we have established destruxin-resistant sublines of HCT116 colon carcinoma cells by selection with the most prevalent derivatives, destruxin (dtx)A, dtxB and dtxE. Various cell biological and molecular techniques were applied to elucidate the regulatory mechanisms underlying these acquired and highly stable destruxin resistance phenotypes. Interestingly, well-known chemoresistance-mediating ABC efflux transporters were not the major players. Instead, in dtxA- and dtxB-resistant cells a hyper-activated mevalonate pathway was uncovered resulting in increased de-novo cholesterol synthesis rates and elevated levels of lanosterol, cholesterol as well as several oxysterol metabolites. Accordingly, inhibition of the mevalonate pathway at two different steps, using either statins or zoledronic acid, significantly reduced acquired but also intrinsic destruxin resistance. Vice versa, cholesterol supplementation protected destruxin-sensitive cells against their cytotoxic activity. Additionally, an increased cell membrane adhesiveness of dtxA-resistant as compared to parental cells was detected by atomic force microscopy. This was paralleled by a dramatically reduced ionophoric capacity of dtxA in resistant cells when cultured in absence but not in presence of statins. Summarizing, our results suggest a reduced ionophoric activity of destruxins due to cholesterol-mediated plasma membrane re-organization as molecular mechanism underlying acquired destruxin resistance in human colon cancer cells. Whether this mechanism might be valid also in other cell types and organisms exposed to destruxins e.g. as bio-insecticides needs to be evaluated.

19.
Clin Chim Acta ; 472: 35-40, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28713031

RESUMO

A validated LC-MS/MS-based candidate reference measurement procedure for the quantification of carbamazepine is presented in order to be used for standardization and harmonization of routine assays applied for therapeutic drug monitoring. Sample preparation was based on protein precipitation using acetonitrile followed by sample dilution. Since the previously listed certified reference material (CRM) SRM 1599 (anticonvulsant drug level assay standard) is no longer available, an ISO certified calibration material was used in this assay. As internal standards deuterated analyte congeners were applied. The method allows the measurement of carbamazepine, carbamazepine-10,11-epoxide and 10-hydroxy-10,11-dihydrocarbamazepine in the concentration range of 0.1 to 22.0µg/ml with LODs and LOQs of <0.1µg/ml and 0.1µg/ml, respectively. Comparative measurement of 105 native patient samples using the here presented method showed a good agreement between two independent laboratories with a mean bias of 0.6%.


Assuntos
Análise Química do Sangue/métodos , Carbamazepina/sangue , Carbamazepina/química , Cromatografia Líquida , Compostos de Epóxi/química , Humanos , Espectrometria de Massas em Tandem
20.
Clin Chim Acta ; 464: 211-217, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27871844

RESUMO

BACKGROUND: Accurate measurement of gentamicin concentration in serum and plasma is required for therapeutic drug monitoring to ensure appropriate treatment of patients. In this work, we present a validated LC-MS/MS-based candidate reference measurement procedure for total gentamicin quantification to be used for standardization and harmonization of routine assays applied for therapeutic drug monitoring of this compound. Total gentamicin is the sum of the concentrations of five known congeners C1, C1a, C2, C2a and C2b. To our knowledge, there is so far no LC-MS method for quantification of total gentamicin in human serum described in literature. METHODS: Sample preparation was based on sample dilution with an aqueous internal standard solution followed by protein precipitation. Stable derivatives of gentamicin-glycine congeners were prepared by chemical synthesis and used as internal standards. The primary calibration material used in this assay was characterized by NMR spectroscopy and the pattern of the gentamicin congeners was determined. The total gentamicin was reported as the sum of the congeners which were quantified individually by LC-MS/MS. RESULTS: The method allows the measurement of total gentamicin in human serum and plasma in the concentration range of 0.1 to 12.0µg/ml with an assay imprecision of ≤6% CV and an assay accuracy between 96% and 114%. LOD and LOQ for the total gentamicin were 0.04µg/ml and 0.13µg/ml, respectively. Comparative measurement of 128 native patient samples using this method implemented at two laboratory sites showed an excellent agreement. CONCLUSIONS: Validation results proved that this protocol describes a robust and reliable method which is suggested as reference measurement procedure for the standardization and harmonization of routine assays for the quantification of total gentamicin.


Assuntos
Análise Química do Sangue/normas , Gentamicinas/sangue , Espectroscopia de Ressonância Magnética/normas , Plasma/química , Soro/química , Espectrometria de Massas em Tandem , Calibragem , Cromatografia Líquida , Humanos , Limite de Detecção , Modelos Lineares , Padrões de Referência , Incerteza