Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Oral Sci ; 65(1): 53-56, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36631127

RESUMO

PURPOSE: The purpose of this study was to investigate the reaction products formed by application of three tooth etchants to hydroxyapatite. METHODS: Tooth etchants with three different compositions, designed for application to teeth before dental adhesive - " K-etchant GEL" (containing phosphoric acid), "Enamel Conditioner" (containing organic acids), and "Multi Etchant" (containing acidic monomer) - were applied to hydroxyapatite plates. RESULTS: Atomic force microscopy measurements revealed that Multi Etchant formed nano-sized particles on the hydroxyapatite. X-ray diffraction and Fourier transform infrared spectrometer analyses of the powdered hydroxyapatite indicated that Enamel Conditioner produced calcium tartrate whereas K-etchant GEL generated monetite. These results indicated that each etchant reacted with hydroxyapatite in a different way. CONCLUSION: Not only differences among the etching ability of etchants, but also differences in the reaction compounds they produce may influence bonding performance in clinical practice.


Assuntos
Colagem Dentária , Durapatita , Ácidos Fosfóricos , Esmalte Dentário , Difração de Raios X , Colagem Dentária/métodos , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina
2.
Inorg Chem ; 61(33): 13022-13033, 2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-35930806

RESUMO

Ionizing radiation-induced paramagnetic defects in calcified tissues like tooth enamel are indicators of irradiation dose. Hydroxyapatite (HA), the principal constituent in these materials, incorporates a variety of anions (CO32-, F-, Cl-, and SiO44-) and cations (Mn2+, Li+, Cu2+, Fe3+, Mg2+, and Na+) that directly or indirectly contribute to the formation of stable paramagnetic centers upon irradiation. Here, we used an underexploited synthesis method based on the ambient temperature setting reaction of a self-hardening calcium phosphate cement (CPC) to create carbonate-containing hydroxyapatite (CHA) and investigate its paramagnetic properties following γ-irradiation. Powder X-ray diffraction and IR spectroscopic characterization of the hardened CHA samples indicate the formation of pure B-type CHA cement. CHA samples exposed to γ-radiation doses ranging from 1 Gy to 150 kGy exhibited an electron paramagnetic resonance (EPR) signal from an orthorhombic CO2•- free radical. At γ-radiation doses from 30 to 150 kGy, a second signal emerged that is assigned to the CO3•- free radical. We observed that the formation of this second species is dose-dependent, which provided a means to extend the useful dynamic range of irradiated CHA to doses >30 kGy. These results indicate that CHA synthesized via a CPC cement is a promising substrate for EPR-based dosimetry. Further studies on the CHA cement are underway to determine the suitability of these materials for a range of biological and industrial dosimetry applications.


Assuntos
Hidroxiapatitas , Sódio , Carbonatos , Durapatita , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Radicais Livres
3.
J Funct Biomater ; 13(2)2022 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-35466216

RESUMO

Orthopedic and craniofacial surgical procedures require the reconstruction of bone defects caused by trauma, diseases, and tumor resection. Successful bone restoration entails the development and use of bone grafts with structural, functional, and biological features similar to native tissues. Herein, we developed three-dimensional (3D) printed fine-tuned hydroxyapatite (HA) biomimetic bone structures, which can be applied as grafts, by using calcium phosphate cement (CPC) bioink, which is composed of tetracalcium phosphate (TTCP), dicalcium phosphate anhydrous (DCPA), and a liquid [Polyvinyl butyral (PVB) dissolved in ethanol (EtOH)]. The ink was ejected through a high-resolution syringe nozzle (210 µm) at room temperature into three different concentrations (0.01, 0.1, and 0.5) mol/L of the aqueous sodium phosphate dibasic (Na2HPO4) bath that serves as a hardening accelerator for HA formation. Raman spectrometer, X-ray diffraction (XRD), and scanning electron microscopy (SEM) demonstrated the real-time HA formation in (0.01, 0.1, and 0.5) mol/L Na2HPO4 baths. Under those conditions, HA was formed at different amounts, which tuned the scaffolds' mechanical properties, porosity, and osteoclast activity. Overall, this method may pave the way to engineer 3D bone scaffolds with controlled HA composition and pre-defined properties, which will enhance graft-host integration in various anatomic locations.

4.
Biomed Mater ; 16(4)2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33254152

RESUMO

Biofabrication has been adapted in engineering patient-specific biosynthetic grafts for bone regeneration. Herein, we developed a three-dimensional (3D) high-resolution, room-temperature printing approach to fabricate osteoconductive scaffolds using calcium phosphate cement (CPC). The non-aqueous CPC bioinks were composed of tetracalcium phosphate, dicalcium phosphate anhydrous, and Polyvinyl butyral (PVB) dissolved in either ethanol (EtOH) or tetrahydrofuran (THF). They were printed in an aqueous sodium phosphate bath, which performs as a hardening accelerator for hydroxyapatite formation and as a retainer for 3D microstructure. The PVB solvents, EtOH or THF, affected differently the slurry rheological properties, scaffold microstructure, mechanical properties, and osteoconductivity. Our proposed approach overcomes limitations of conventional fabrication methods, which require high-temperature (>50 °C), low-resolution (>400 µm) printing with an inadequate amount of large ceramic particles (>35 µm). This proof-of-concept study opens venues in engineering high-resolution, implantable, and osteoconductive scaffolds with predetermined properties for bone regeneration.


Assuntos
Durapatita , Alicerces Teciduais , Cimentos Ósseos/química , Regeneração Óssea , Durapatita/química , Humanos , Impressão Tridimensional , Engenharia Tecidual/métodos , Alicerces Teciduais/química
5.
J Oral Sci ; 57(1): 25-30, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25807905

RESUMO

We compared the effects of treatment with fluorapatite-forming calcium phosphate cement (FA-forming CPC) containing tricalcium silicate (TCS) and those of mineral trioxide aggregate (MTA), the gold standard endodontic cement, on cultured osteoblast-like cells (ROS 17/2.8 cells; ROS cells). The FA-forming CPC powder consisted of 61.29% CaHPO4, 32.26% CaCO3, and 6.45% NaF. One part TCS was combined with nine parts FA-forming CPC powder to make FA-forming CPC with TCS. A 1.5-M phosphate solution was mixed as a cement liquid with a powder/liquid ratio of 2.22. Cell culture was carried out using cell culture inserts, whereby each test material was put on a porous membrane insert in the cell culture plate. Proliferation, morphologic changes, and alkaline phosphatase activity in ROS cells were measured in the presence of FA-forming CPC with TCS and MTA and compared. The logarithmic growth phase and cellular morphologic changes in ROS cells were identical in all experimental groups. Additionally, no significant difference in alkaline phosphatase activity was noted in ROS cells exposed to FA-forming CPC with TCS and those exposed to MTA. In conclusion, FA-forming CPC with TCS has characteristics identical to those of MTA under the present experimental conditions and may thus be useful for endodontic applications.


Assuntos
Compostos de Alumínio/farmacologia , Apatitas/farmacologia , Compostos de Cálcio/farmacologia , Fosfatos de Cálcio/farmacologia , Cimentos Dentários/farmacologia , Osteoblastos/efeitos dos fármacos , Óxidos/farmacologia , Materiais Restauradores do Canal Radicular/farmacologia , Silicatos/farmacologia , Fosfatase Alcalina/metabolismo , Animais , Proliferação de Células , Células Cultivadas , Combinação de Medicamentos , Osteoblastos/metabolismo , Ratos
6.
Dent Mater J ; 34(2): 263-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25740309

RESUMO

Aim of this study was to develop a novel fluorapatite-forming calcium phosphate cement (FA-CPC) with tricalcium silicate (TCS) for endodontic applications and to examine its in vitro and in vivo characteristics. The FA-CPC powder consisted of 62.8% CaHPO4, 30.8% CaCO3, and 6.4% NaF. One part of TCS was combined with 9 parts of FA-CPC powder (FA-CPC with TCS). A 1.5 M phosphate solution was used as cement liquid. Setting time (ST), diametral tensile strength (DTS), phase composition by X-ray diffraction (XRD), and cement alkalinity were analyzed. Cement biocompatibility was assessed using rat subcutaneous model. Cement ST was 10.3±0.6 min and DTS was 3.89±0.76 MPa. XRD patterns showed that highly crystalline apatitic material was the only significant phase present and pH value was approximate 11.0. FA-CPC with TCS demonstrated similar biocompatibility as that of mineral trioxide aggregate control. These results suggest that FA-CPC with TCS may be useful for endodontic applications.


Assuntos
Apatitas/química , Cimentos Ósseos/química , Compostos de Cálcio/química , Fosfatos de Cálcio/química , Silicatos/química , Animais , Cimentos Dentários , Teste de Materiais , Ratos , Resistência à Tração , Difração de Raios X
7.
J Res Natl Inst Stand Technol ; 115(4): 225-232, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21037951

RESUMO

The bone defect repair functions of calcium phosphate cement (CPC) are related to its osteoconductivity and its gradual replacement by new bone. Adding mannitol to CPC may enhance its bone repair potential by increasing CPCs macroporosity and dissolution rate. The objective of the study was to assess microporosity and macroporosity and dissolution rates for CPC mixed with mannitol. Three groups of CPC discs were prepared by combining an equimolar mixture of tetracalcium phosphate and anhydrous dicalcium phosphate with (0 %, 10 %, or 50 %) mass fraction (hereafter expressed as mass %) of mannitol. Macroporosity and microporosity of the samples were calculated from volume and mass measurements of the discs. Discs were then placed in a pH 3.0 demineralizing solution simulating acidified physiological solution, and dissolution rates were measured by a previously described constant-composition titration method. Pure CPC exhibited no macropores and microporosity (mean ± s.d.; n = 5) of (46.8 ± 0.8) % volume fraction (hereafter expressed as vol %). Adding 10 mass % mannitol resulted in 15.6 ± 3.9 vol % macroporosity and 39.4 ± 1.8 vol % microporosity, and adding 50 mass % mannitol produced 54.7 ± 0.8 vol % macroporosity and 21.1 ± 0.4 vol % microporosity. The dissolution rates (mean ± s.d.; n = 5) of CPC with (0, 10, and 50) mass % mannitol incorporation were (30.6 ± 3.4, 44.8 ± 10.2, and 54.7 ± 3.6, respectively) µg · cm(-2) · min(-1), or (0.018 ± 0.002, 0.032 ± 0.007, and 0.072 ± 0.005, respectively) µL · cm(-2) · min(-1). Adding either 10 mass % or 50 mass % mannitol into CPC significantly (p < 0.05) increased CPC dissolution rates. Adding mannitol readily increased macroporosity and dissolution rate of CPC, which may enhance the capacity of CPC to be osteoconductive.

8.
J Res Natl Inst Stand Technol ; 115(4): 277-290, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21037803

RESUMO

Previous studies showed that water-free, premixed calcium phosphate cements (Pre-CPCs) exhibited longer hardening times and lower strengths than conventional CPCs, but were stable in the package. The materials hardened only after being delivered to a wet environment and formed hydroxyapatite as the only product. Pre-CPCs also demonstrated good washout resistance and excellent biocompatibility when implanted in subcutaneous tissues in rats. The present study evaluated characteristics of Pre-CPCs when implanted in subcutaneous tissues (Study I) and used for repairing surgically created two-wall periodontal defects (Study II). Pre-CPC pastes were prepared by combining CPC powders that consisted of CPC-1: Ca(4)(PO(4))(2)O and CaHPO(4), CPC-2: α-Ca(3)(PO(4))(2) and CaCO(3) or CPC-3: DCPA and Ca(OH)(2) with a glycerol at powder-to-liquid mass ratios of 3.5, 2.5, and 2.5, respectively. In each cement mixture, the Ca to P molar ratio was 1.67. The glycerol contained Na(2)HPO(4) (30 mass %) and hydroxypropyl methylcellulose (0.55 %) to accelerate cement hardening and improve washout resistance, respectively. In Study I, the test materials were implanted subcutaneously in rats. Four weeks after the operation, the animals were sacrificed and histopathological observations were performed. The results showed that all of the implanted materials exhibited very slight or negligible inflammatory reactions in tissues contacted with the implants. In Study II, the mandibular premolar teeth of mature beagle dogs were extracted. One month later, two-wall periodontal bone defects were surgically created adjacent to the teeth of the mandibular bone. The defects were filled with the Pre-CPC pastes and the flaps replaced in the preoperative position. The dogs were sacrificed at 1, 3 and 6 months after surgery and sections of filled defects resected. Results showed that one month after surgery, the implanted Pre-CPC-1 paste was partially replaced by bone and was converted to bone at 6 months. The pockets filled with Pre-CPC-2 were completely covered by newly formed bone in 1 month. The Pre-CPC-2 was partially replaced by trabecular bone in 1 month and was completely replaced by bone in 6 months. Examination of 1 month and 3 month samples indicated that Pre-CPC-2 resorbed and was replaced by bone more rapidly than Pre-CPC 1. Both Pre-CPC pastes were highly osteoconductive. When implanted in periodontal defects, Pre-CPC-2 was replaced by bone more rapidly than Pre-CPC-1.

9.
J Dent ; 38(9): 736-41, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20685375

RESUMO

OBJECTIVE: A sequential topical application of calcium and fluoride-phosphate solutions was reported to occlude open dentin tubules, mainly with fluoroapatite precipitates by a rapid ionic reaction, and to be effective at treating dentin hypersensitivity. However, its ability to reduce dentin permeability (Lp) is unknown. The aim of this in vitro study was to evaluate the effect of this treatment on Lp. METHODS: Nine extracted human third molars were sectioned transversely to obtain 0.5 mm-thick discs, which were then etched and rinsed. Aqueous solutions of 5% (w/w) disodium phosphate containing 0.3% (w/w) sodium fluoride (A) and 10% (w/w) calcium chloride (B) were prepared. The sequential application of the A&B solutions was repeated three times on each disc, which was then rinsed with distilled water. The Lp of the discs was measured before and after the application using a modified Pashley's fluid flow measuring system. The differences in the Lp values between the conditions before and after the solution applications were analysed using a generalized estimating equation method and paired t-test. Scanning Electron Microscopy (SEM) was used to observe the dentin surfaces. RESULTS: All nine discs consistently indicated reduced Lp following the application of the A&B solutions. There was a significant decrease in the mean Lp [microL/(cm(2) s cm H(2)O)] from baseline (-0.27+/-0.25, p=0.011). Overall, an average decrease of 34% Lp occurred after the application of the A&B solutions. SEM observation indicated that the reaction products covered the entire dentin disc surface. CONCLUSION: The application of the A&B solutions was effective at reducing the Lp of the dentin discs.


Assuntos
Cloreto de Cálcio/farmacologia , Dessensibilizantes Dentinários/farmacologia , Permeabilidade da Dentina/efeitos dos fármacos , Fosfatos/farmacologia , Fluoreto de Sódio/farmacologia , Apatitas/química , Apatitas/farmacologia , Cloreto de Cálcio/química , Precipitação Química , Ácido Cítrico/farmacologia , Dentina/efeitos dos fármacos , Dentina/metabolismo , Dentina/ultraestrutura , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Fosfatos/química , Camada de Esfregaço , Fluoreto de Sódio/química
10.
Tissue Eng Part A ; 16(9): 2743-53, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20388037

RESUMO

Tissue engineering offers immense promise for bone regeneration. Human umbilical cord mesenchymal stem cells (hUCMSCs) can be collected without invasive procedures required for bone marrow MSCs. The objective of this study was to investigate the physical properties and the differentiation capacity of hUCMSCs on calcium phosphate cement (CPC) scaffolds with improved dissolution/resorption rates. CPC consisted of tetracalcium phosphate and dicalcium phosphate anhydrous, with various tetracalcium phosphate/dicalcium phosphate anhydrous ratios. At 1/3 ratio, CPC had a dissolution rate 40% faster than CPC control at 1/1. The faster-resorbable CPC had strength and modulus similar to CPC control. Their strength and modulus exceeded the reported values for cancellous bone, and were much higher than those of hydrogels and injectable polymers for cell delivery. hUCMSCs attached to the nano-apatitic CPC and proliferated rapidly. hUCMSCs differentiated into the osteogenic lineage, with significant increases in alkaline phosphatase activity, osteocalcin, collagen I, and osterix gene expression. In conclusion, in this study we reported that hUCMSCs attaching to CPC with high dissolution/resorption rate showed excellent proliferation and osteogenic differentiation. hUCMSCs delivered via high-strength CPC have the potential to be an inexhaustible and low-cost alternative to the gold-standard human bone marrow mesenchymal stem cells. These results may broadly impact stem-cell-based tissue engineering.


Assuntos
Cimentos Ósseos/química , Cimentos Ósseos/metabolismo , Fosfatos de Cálcio/química , Fosfatos de Cálcio/metabolismo , Células-Tronco/citologia , Engenharia Tecidual/métodos , Cordão Umbilical/citologia , Humanos , Alicerces Teciduais
11.
J Res Natl Inst Stand Technol ; 115(4): 267-276, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21479080

RESUMO

This study reports for the first time in vitro and in vivo properties of fluorapatite (FA)-forming calcium phosphate cements (CPCs). The experimental cements contained from (0 to 3.1) mass % of F, corresponding to presence of FA at levels of approximately (0 to 87) mass %. The crystallinity of the apatitic cement product increased greatly with the FA content. When implanted subcutaneously in rats, the in vivo resorption rate decreased significantly with increasing FA content. The cement with the highest FA content was not resorbed in soft tissue, making it the first known biocompatible and bioinert CPC. These bioinert CPCs might be useful for applications where slow or no resorption of the implant is required to achieve the desired clinical outcome.

12.
J Res Natl Inst Stand Technol ; 115(4): 233-241, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21479133

RESUMO

Previous studies reported premixed calcium phosphate cements (CPCs) that were stable in the package and form hydroxyapatite (HA) as the product after exposure to an aqueous environment. These cements had setting times of greater than 60 min, which are too long to be useful for some clinical applications. The present study investigated properties of fast-setting HA-forming premixed CPCs that initially consisted of two separate premixed pastes: (1) finely ground (1.0 µm in median size) dicalcium phosphate anhydrous (DCPA) mixed with an aqueous NaH(2)PO(4) solution, 1.5 mol/L or 3.0 mol/L in concentration, and (2) tetracalcium phosphate consisting of combinations of particles of two different size distributions, 5 µm (TTCP5) and 17 µm (TTCP17) in median size, mixed with glycerin. Equal volume of Pastes 1 and 2 were injected with the use of atwo-barrel syringe fitted with a static mixer into sample molds. The molar Ca/P ratio of combined paste was approximately 1.5. Cements were characterized in terms of setting time (Gilmore needle), diametral tensile strength (DTS), and phase composition (powder x-ray diffraction, XRD). Setting times were found to range from (4.3 ± 0.6 to 68 ± 3) min (mean ± sd; n = 3), and 1-d and 7-d DTS values were from (0.89 ± 0.08 to 2.44 ± 0.16) MPa (mean ± sd; n = 5). Both the NaH(2)PO(4) concentration and TTCP particle size distribution had significant (p < 0.01) effects on setting time and DTS. Powder XRD analysis showed that low crystallinity HA and unreacted DCPA were present in the 1-day specimens, and the extent of HA formation increased with increasing amount of TTCP5 in the TTCP paste. CONCLUSION: Injectable HA-forming premixed CPCs with setting times from 4 to 70 min can be prepared by using DCPA and TTCP as the ingredients. Compared to the conventional powder liquid cements, these premixed CPCs have the advantages of being easy to use and having a range of hardening times.

13.
J Res Natl Inst Stand Technol ; 115(6): 471-6, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-27134799

RESUMO

A calcium phosphate cement (CPC) was shown to have the necessary attributes for endodontic materials except adequate basicity needed for antimicrobial properties. To enhance its basicity, tricalcium silicate (Ca3SiO5), a highly alkaline compound, was added to CPC at a mass fraction of 0.25, 0.5 or 0.75. The basicity, acid neutralization and physical properties of the CPC-Ca3SiO5 composites were investigated. Mineral trioxide aggregate (MTA) was used as the control. The acid neutralizing capacity of the CPC-Ca3SiO5 composites and MTA were measured by titrating the suspensions of ground set samples with a 0.2 mol / L HCl at predetermined pH levels, i.e., 11, 9.0, and 7.4. The setting time of CPC-Ca3SiO5 composites determined by the Gilmore needle method was 40 ± 10 min. Acid neutralizing capacity of CPC depended (p < 0.05) on Ca3SiO5 content. CPC containing 75 % Ca3SiO5 could neutralize slightly less acid than MTA (p < 0.05), but it had a shorter setting time than that of MTA (> 4 h) and excellent handling properties.

14.
J Mater Sci Mater Med ; 20(8): 1771-9, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19365616

RESUMO

Secondary caries and restoration fracture are common problems in restorative dentistry. The aim of this study was to develop Ca-PO(4) nanocomposite having improved stress-bearing properties and Ca and PO(4) ion release to inhibit caries, and to determine the effects of filler level. Nanoparticles of dicalcium phosphate anhydrous (DCPA), two larger DCPA powders, and reinforcing whiskers were incorporated into a resin. A 6 x 3 design was tested with six filler mass fractions (0, 30, 50, 65, 70, and 75%) and three DCPA particle sizes (112 nm, 0.88 mum, 12.0 mum). The DCPA nanocomposite at 75% fillers had a flexural strength (mean +/- SD; n = 6) of 114 +/- 23 MPa, matching the 112 +/- 22 MPa of a commercial non-releasing, hybrid composite (P > 0.1). This was 2-fold of the 60 +/- 6 MPa of a commercial releasing control. Decreasing the particle size increased the ion release. Increasing the filler level increased the ion release at a rate faster than being linear. The amount of ion release from the nanocomposite matched or exceeded those of previous composites that released supersaturating levels of Ca and PO(4) and remineralized tooth lesions. This suggests that the much stronger nanocomposite may also be effective in remineralizing tooth lesion and inhibiting caries. In summary, combining calcium phosphate nanoparticles with reinforcing co-fillers in the composite provided a way to achieving both caries-inhibiting and stress-bearing capabilities. Filler level and particle size can be tailored to achieve optimal composite properties.


Assuntos
Resinas Acrílicas/química , Fosfatos de Cálcio/uso terapêutico , Resinas Compostas/química , Cárie Dentária/prevenção & controle , Restauração Dentária Permanente/métodos , Tamanho da Partícula , Poliuretanos/química , Resinas Acrílicas/síntese química , Resinas Acrílicas/farmacocinética , Resinas Acrílicas/uso terapêutico , Cálcio/farmacocinética , Fosfatos de Cálcio/síntese química , Fosfatos de Cálcio/química , Fosfatos de Cálcio/farmacocinética , Cariostáticos/síntese química , Cariostáticos/química , Cariostáticos/uso terapêutico , Resinas Compostas/síntese química , Resinas Compostas/farmacocinética , Resinas Compostas/uso terapêutico , Humanos , Teste de Materiais , Fosfatos/farmacocinética , Maleabilidade , Poliuretanos/síntese química , Poliuretanos/farmacocinética , Poliuretanos/uso terapêutico , Estresse Mecânico , Suporte de Carga/fisiologia
15.
J Res Natl Inst Stand Technol ; 113(6): 311-320, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19779581

RESUMO

Calcium phosphate cements (CPCs) were prepared using mixtures of tetracalcium phosphate (TTCP) and dicalcium phosphate anhydrous (DCPA), with TTCP/DCPA molar ratios of 1/1, 1/2, or 1/3, with the powder and water as the liquid. Diametral tensile strength (DTS), porosity, and phase composition (powder x-ray diffraction) were determined after the set specimens have been immersed in a physiological-like solution (PLS) for 1 d, 5 d, and 10 d. Cement dissolution rates in an acidified PLS were measured using a dual constant composition method. Setting times ((30 ± 1) min) were the same for all cements. DTS decreased with decreasing TTCP/DCPA ratio and, in some cases, also decreased with PLS immersion time. Porosity and hydroxyapatite (HA) formation increased with PLS immersion time. Cements with TTCP/DCPA ratios of 1/2 and 1/3, which formed calcium-deficient HA, dissolved more rapidly than the cement with a ratio of 1/1. In conclusion, cements may be prepared with a range of TTCP/DCPA ratios, and those with lower ratio had lower strengths but dissolved more rapidly in acidified PLS.

16.
Dent Mater J ; 27(6): 787-94, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19241686

RESUMO

A calcium phosphate cement (CPC-1), prepared by mixing an equimolar mixture of tetracalcium phosphate and dicalcium phosphate anhydrous with water, has been shown to be highly biocompatible and osteoconductive. A new type of calcium phosphate cement (CPC-2), prepared by mixing a mixture of alpha-tricalcium phosphate and calcium carbonate with pH 7.4 sodium phosphate solution, was also reported to be highly biocompatible. The objective of the present study was to compare the osteoconductivities of CPC-1 and CPC-2 when implanted in surgically created defects in the jaw bones of dogs. At 1 month after surgery, implanted CPC-1 was partially replaced by new bone and converted to bone within 6 months. In comparison, at 1 month after surgery, the defect filled with CPC-2 was mostly replaced by new bone. Therefore, bone formation in CPC-2-filled pocket was more rapid than in CPC-1-filled pocket. These findings supported the hypothesis that CPC-2 converted to bone more rapidly than CPC-1.


Assuntos
Perda do Osso Alveolar/cirurgia , Materiais Biocompatíveis/uso terapêutico , Cimentos Ósseos/uso terapêutico , Substitutos Ósseos/uso terapêutico , Fosfatos de Cálcio/uso terapêutico , Perda do Osso Alveolar/patologia , Animais , Materiais Biocompatíveis/síntese química , Cimentos Ósseos/síntese química , Regeneração Óssea/efeitos dos fármacos , Substitutos Ósseos/síntese química , Carbonato de Cálcio/química , Fosfatos de Cálcio/síntese química , Fosfatos de Cálcio/química , Tecido Conjuntivo/patologia , Cães , Durapatita/química , Tecido de Granulação/patologia , Concentração de Íons de Hidrogênio , Mandíbula/efeitos dos fármacos , Mandíbula/patologia , Mandíbula/cirurgia , Osteoblastos/patologia , Osteoclastos/patologia , Osteogênese/efeitos dos fármacos , Fosfatos/química , Distribuição Aleatória , Retalhos Cirúrgicos , Fatores de Tempo , Cicatrização/efeitos dos fármacos
17.
J Biomed Mater Res B Appl Biomater ; 81(1): 116-25, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16924611

RESUMO

Clinical data indicate that secondary caries and restoration fracture are the most common problems facing tooth restorations. Our ultimate goal was to develop mechanically-strong and caries-inhibiting dental composites. The specific goal of this pilot study was to understand the relationships between composite properties and the ratio of reinforcement filler/releasing filler. Nanoparticles of monocalcium phosphate monohydrate (MCPM) were synthesized and incorporated into a dental resin for the first time. Silicon carbide whiskers were fused with silica nanoparticles and mixed with the MCPM particles at MCPM/whisker mass ratios of 1:0, 2:1, 1:1, 1:2, and 0:1. The composites were immersed for 1-56 days to measure Ca and PO4 release. When the MCPM/whisker ratio was changed from 0:1 to 1:2, the composite flexural strength (mean +/- SD; n = 5) decreased from 174 +/- 26 MPa to 138 +/- 9 MPa (p < 0.05). A commercial nonreleasing composite had a strength of 112 +/- 14 MPa. When the MCPM/whisker ratio was changed from 1:2 to 1:1, the Ca concentration at 56 days increased from 0.77 +/- 0.04 mmol/L to 1.74 +/- 0.06 mmol/L (p < 0.05). The corresponding PO4 concentration increased from 3.88 +/- 0.21 mmol/L to 9.95 +/- 0.69 mmol/L (p < 0.05). Relationships were established between the amount of release and the MCPM volume fraction v(MCPM) in the resin: [Ca]= 42.9 v(MCPM) (2.7), and [PO4] = 48.7 v(MCPM) (1.4). In summary, the method of combining nanosized releasing fillers with reinforcing fillers yielded Ca- and PO4-releasing composites with mechanical properties matching or exceeding a commercial stress-bearing, nonreleasing composite. This method may be applicable to the use of other Ca-PO4 fillers in developing composites with high stress-bearing and caries-preventing capabilities, a combination not yet available in any dental materials.


Assuntos
Fosfatos de Cálcio/química , Resinas Compostas/química , Materiais Dentários/química , Nanopartículas/química , Compostos Inorgânicos de Carbono/química , Cárie Dentária/prevenção & controle , Elasticidade , Teste de Materiais , Tamanho da Partícula , Compostos de Silício/química , Resistência à Tração
18.
J Biomater Appl ; 21(3): 299-315, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16543283

RESUMO

Calcium phosphate cement (CPC) can self-harden in vivo to form hydroxyapatite (HA) with excellent osteoconductivity. In recent studies, CPC-chitosan composites are developed with high mechanical strength and washout resistance. The objectives of the present study are to optimize the setting time and mechanical properties of a CPC-chitosan composite by tailoring the chitosan content, and to evaluate the bioresorbability by using an in vitro dissolution model. Six chitosan mass fractions are tested: 0, 10, 15, 20, 25, and 30%. Specimens are immersed in solutions with pH ranging from 3.5 to 5 to simulate the acidic environments produced by osteoclasts in vivo. Dissolution is measured as the fraction of mass loss versus immersion time from 7d to 28d. The CPC-chitosan composite with 20% by mass chitosan has a setting time (mean+/-SD; n=4) of 13 1 min, significantly less than 87 7 min for CPC control without chitosan (p<0.05). The composite flexural strength (mean+/-SD; n 1/4 6) was 14 2 MPa, significantly higher than 4 1 MPa of CPC control (p<0.05). At an intermediate pH of 4.5, the fraction of mass loss for CPC with 20% chitosan and CPC control without chitosan are not significantly different (p>0.1). The dissolution rates (fraction of mass loss per day,%/d) were 1.05 for CPC control and 1.08 for CPC-chitosan. In summary, a CPC-chitosan composite is developed with fast-setting and a flexural strength three-fold of that of CPC control without chitosan. Both materials are soluble in acidic environments, indicating that adding chitosan did not compromise the bioresorbability of CPC. The strong and resorbable CPC-chitosan composite may be useful in moderate stress-bearing craniofacial and orthopedic repairs.


Assuntos
Cimentos Ósseos/química , Fosfatos de Cálcio/química , Quitosana/química , Elasticidade , Dureza , Testes de Dureza , Cinética , Manufaturas/análise , Teste de Materiais , Mecânica , Tamanho da Partícula , Fatores de Tempo
19.
Dent Mater ; 23(4): 433-41, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16678895

RESUMO

OBJECTIVES: Calcium phosphate cement (CPC) is a promising material for dental, periodontal, and craniofacial repairs. However, its use requires on-site powder-liquid mixing that increases the surgical placement time and raises concerns of insufficient and inhomogeneous mixing. The objective of this study was to determine a formulation of premixed CPC (PCPC) with rapid setting, high strength, and good in vitro cell viability. METHODS: PCPCs were formulated from CPC powder+non-aqueous liquid+gelling agent+hardening accelerator. Five PCPCs were thus developed: PCPC-Tartaric, PCPC-Malonic, PCPC-Citric, PCPC-Glycolic, and PCPC-Malic. Formulations and controls were compared for setting time, diametral tensile strength, and osteoblast cell compatibility. RESULTS: Setting time (mean+/-S.D.; n=4) for PCPC-Tartaric was 8.2+/-0.8 min, significantly less than the 61.7+/-1.5 min for the Premixed Control developed previously (p<0.001). On 7th day immersion, the diametral tensile strength of PCPC-Tartaric reached 6.5+/-0.8 MPa, higher than 4.5+/-0.8 MPa of Premixed Control (p=0.036). Osteoblast cells displayed a polygonal morphology and attached to the nano-hydroxyapatite crystals in the PCPCs. All cements had similar live cell density values (p=0.126), indicating that the new PCPCs were as cell compatible as a non-premixed CPC control known to be biocompatible. Each of the new PCPCs had a cell viability that was not significantly different (p>0.1) from that of the non-premixed CPC control. SIGNIFICANCE: PCPCs will eliminate the powder-liquid mixing during surgery and may also improve the cement performance. The new PCPCs supported cell attachment and yielded a high cell density and viability. Their mechanical strengths approached the reported strengths of sintered porous hydroxyapatite implants and cancellous bone. These nano-crystalline hydroxyapatite cements may be useful in dental, periodontal, and craniofacial repairs.


Assuntos
Fosfatos de Cálcio/toxicidade , Cimentos Dentários/toxicidade , Hidroxiapatitas/toxicidade , Osteoblastos/efeitos dos fármacos , Células 3T3 , Animais , Adesão Celular , Sobrevivência Celular , Cimentos Dentários/síntese química , Análise do Estresse Dentário , Durapatita , Hidroxiapatitas/síntese química , Camundongos , Nanoestruturas , Tartaratos/química , Resistência à Tração
20.
J Biomed Mater Res B Appl Biomater ; 78(2): 291-5, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16906596

RESUMO

Treatments that obdurate dentin tubules have been used for reducing dentin hypersensitivity. The purpose of this study was to determine the effect of a treatment with a slurry of micron sized calcium phosphate on the hydraulic conductance (L(p)) of etched dentin discs in vitro. The treatment slurry was prepared by mixing a powder mixture of dicalcium phosphate anhydrous and calcium hydroxide with a solution that contained sodium fluoride and carboxymethyl cellulose. The mean baseline L(p) (in mL cm(-2) s(-1) H(2)O cm(-1)) was 2.07 +/- 1.45 (mean +/- SD; n = 13)). After one treatment and 2, 4, and 7 days of incubation in a protein-free saliva-like solution (SLS), the mean relative L(p), presented as % of baseline, were 65 +/- 16, 42 +/- 27, 36 +/- 26, and 33 +/- 27 (n = 13), respectively. The L(p) values of the baseline and treatment after incubation in the SLS were significantly (p < 0.05) different. Scanning electron microscopic examination showed partial obturation of dentin tubules in the treated dentin. X-ray diffraction and chemical analyses indicated the major product formed from the slurry was a fluoride-containing hydroxyapatite. Treatment appeared effective in further reducing L(p) of dentin discs after incubation in the SLS.


Assuntos
Hidróxido de Cálcio/química , Fosfatos de Cálcio/química , Permeabilidade da Dentina , Dentina , Carboximetilcelulose Sódica , Dentina/ultraestrutura , Humanos , Fluoreto de Sódio , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA