Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 28(Pt 6): 1758-1768, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34738929

RESUMO

A new correction algorithm for closed orbit distortion based on an adaptive feedforward control (AFC) has been developed. At SPring-8, two helicity-switching twin-helical undulators (THUs) had been implemented with conventional feedforward corrections. However, the validity of these corrections turned out to be expiring due to unforeseen variation in the error magnetic fields with time. The developed AFC system has been applied to the THUs dynamically updating the feedforward table without stopping the helicity switching amid user experiments. The error sources in the two THUs are successfully resolved and corrected even while the two THUs are switching simultaneously with the same repetition period. The actual operation of the new AFC system enables us to keep the orbit variations suppressed with an accuracy at the sub-micrometre level in a transparent way for light source users.

2.
J Synchrotron Radiat ; 10(Pt 4): 295-302, 2003 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-12824928

RESUMO

A two-dimensional visible synchrotron light interferometer has been developed to measure the transverse profile of an electron beam at the SPring-8 storage ring. The new interferometer enables the simultaneous measurement of beam sizes along the major and minor axes and the beam-tilt angle of an assumed elliptical Gaussian distribution. The principle of the interferometer is explained through basic formulae. To calibrate the point-spread function of the interferometer, a simple error model was assumed for disturbances in the amplitude and phase of the light; these disturbances were presumably caused by optical elements, such as mirrors and lenses. The experimental method to determine the parameters in the error model is shown. To verify the two-dimensional profiling capabilities of the interferometer, an electron beam stored in the SPring-8 storage ring operated at various working points was observed. A beam broadening from 20 to 120 microm in the vertical direction and changes in the beam-tilt angle were clearly observed at working points close to the differential resonance. However, the vertical spatial resolution is limited by the available vertical separation of the apertures of the diffracting mask because of the narrow aperture of the upstream vacuum duct.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA