Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Magn Reson Med Sci ; 23(2): 225-237, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36682776

RESUMO

Free-running 5D whole-heart coronary MR angiography (MRA) is gaining in popularity because it reduces scanning complexity by removing the need for specific slice orientations, respiratory gating, or cardiac triggering. At 3T, a gradient echo (GRE) sequence is preferred in combination with contrast injection. However, neither the injection scheme of the gadolinium (Gd) contrast medium, the choice of the RF excitation angle, nor the dedicated image reconstruction parameters have been established for 3T GRE free-running 5D whole-heart coronary MRA. In this study, a Gd injection scheme, RF excitation angles of lipid-insensitive binominal off-resonance RF excitation (LIBRE) pulse for valid fat suppression and continuous data acquisition, and compressed-sensing reconstruction regularization parameters were optimized for contrast-enhanced free-running 5D whole-heart coronary MRA using a GRE sequence at 3T. Using this optimized protocol, contrast-enhanced free-running 5D whole-heart coronary MRA using a GRE sequence is feasible with good image quality at 3T.


Assuntos
Meios de Contraste , Coração , Coração/diagnóstico por imagem , Angiografia Coronária/métodos , Angiografia por Ressonância Magnética/métodos , Gadolínio
2.
Diagnostics (Basel) ; 12(4)2022 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-35454062

RESUMO

Unstable carotid plaques are visualized as high-signal plaques (HSPs) on 3D turbo spin-echo T1-weighted black-blood vessel wall imaging (3D TSE T1-BB VWI). The purpose of this study was to compare manual segmentation and semiautomated segmentation for the quantification of carotid HSPs using 3D TSE T1-BB VWI. Twenty cervical carotid plaque lesions in 19 patients with a plaque contrast ratio of > 1.3 compared to adjacent muscle were studied. Using the mean voxel value for the adjacent muscle multiplied by 1.3 as a threshold value, the semiautomated software exclusively segmented and measured the HSP volume. Manual and semiautomated HSP volumes were well correlated (r = 0.965). Regarding reproducibility, the inter-rater ICC was 0.959 (bias: 24.63, 95% limit of agreement: −96.07, 146.35) for the manual method and 0.998 (bias: 15.2, 95% limit of agreement: −17.83, 48.23) for the semiautomated method, indicating improved reproducibility by the semiautomated method compared to the manual method. The time required for semiautomated segmentation was significantly shorter than that of manual segmentation times (81.7 ± 7.8 s versus 189.5 ± 49.6 s; p < 0.01). The results obtained in this study demonstrate that the semiautomated segmentation method allows for reliable assessment of the HSP volume in patients with carotid plaque lesions, with reduced time and effort for the analysis.

3.
J Matern Fetal Neonatal Med ; 35(25): 5274-5281, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33491514

RESUMO

AIM: Noninvasive blood oxygen level-dependent magnetic resonance imaging (BOLD-MRI) has recently been used to evaluate placental oxygenation. However, this method still has unresolved problems, such as long testing times and lack of normal values set. In the present study, we used a shorter protocol in BOLD-MRI and established normal values for placental oxygenation in late pregnancy. METHODS: We recruited 18 healthy singleton pregnant women (>32 weeks of gestation) who had a normal body size before pregnancy and a normal course of pregnancy. They underwent BOLD-MRI with three consecutive 4-min periods of different oxygenation: normoxia (21% O2), hyperoxia (10 L O2/min), and then normoxia. Placental time-activity curves were presented as signal intensity change relative to baseline (ΔR2*). The time from starting maternal oxygen administration to peak ΔR2*. To assess the relationship between peak ΔR2* values and placenta-related parameters and fetal development, the correlation between peak ΔR2*, placental weight, and neonatal birth weight was evaluated using Spearman's rank correlation test. RESULTS: In all cases, the BOLD signal was elevated by maternal oxygen administration, with the peak resolving within 4 min after the end of oxygen administration. Peak ΔR2* and time to peak ΔR2* during oxygenation were 7.99 ± 2.58, and 458.1 ± 73.9 s, respectively. There was a significant correlation between peak ΔR2* and neonatal birth weight (percentile) (r = 0.537, p = .022), and between placental weight and neonatal birth weight (r = 0.769, p < .01). CONCLUSIONS: In all cases, the BOLD signal increased with maternal hyperoxia using this protocol. So, 4 min observation following maternal oxygen administration is sufficient for peak ΔR2* evaluation. These reference values set in this study may be one of the indicators of BOLD signal changes in normal pregnancies after 32 weeks of gestation.


Assuntos
Hiperóxia , Placenta , Recém-Nascido , Gravidez , Feminino , Humanos , Placenta/diagnóstico por imagem , Placenta/metabolismo , Peso ao Nascer , Saturação de Oxigênio , Oxigênio , Imageamento por Ressonância Magnética/métodos
4.
J Cardiovasc Magn Reson ; 23(1): 56, 2021 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-33993891

RESUMO

BACKGROUND: Coronary magnetic resonance angiography (CMRA) allows non-ionizing visualization of luminal narrowing in coronary artery disease (CAD). Although a prior study showed the usefulness of CMRA for risk stratification in short-term follow-up, the long-term prognostic value of CMRA remains unclear. The purpose of this study was to evaluate the long-term prognostic value of CMRA. METHODS: A total of 506 patients without history of myocardial infarction or prior coronary artery revascularization underwent free-breathing whole-heart CMRA between 2009 and 2015. Images were acquired using a 1.5 T or 3 T scanner and visually evaluated as the consensus decisions of two observers. Obstructive CAD on CMRA was defined as luminal narrowing of ≥ 50% in at least one coronary artery. Major adverse cardiac events (MACE) comprised cardiac death, nonfatal myocardial infarction, and unstable angina. RESULTS: Obstructive CAD on CMRA was observed in 214 patients (42%). During follow-up (median, 5.6 years), 31 MACE occurred. Kaplan-Meier curve analysis revealed a significant difference in event-free survival between patients with and without obstructive CAD for MACE (log-rank, p = 0.003) and cardiac death (p = 0.012). Annualized event rates for MACE in patients with no obstructive CAD, 1-vessel disease, 2-vessel disease, and left-main or 3-vessel disease were 0.6%, 1.5%, 2.3%, and 3.6%, respectively (log-rank, p = 0.003). Cox proportional hazard regression analysis showed that, among obstructive CAD on CMRA and clinical risk factors (age, sex, hypertension, diabetes, dyslipidemia, smoking, and family history of CAD), obstructive CAD and diabetes were significant predictors of MACE (hazard ratios, 2.9 [p = 0.005] and 2.2 [p = 0.034], respectively). In multivariate analysis, obstructive CAD remained an independent predictor (adjusted hazard ratio, 2.6 [p = 0.010]) after adjusting for diabetes. Addition of obstructive CAD to clinical risk factors significantly increased the global chi-square result from 8.3 to 13.8 (p = 0.022). CONCLUSIONS: In long-term follow-up, free breathing whole heart CMRA allows non-invasive risk stratification for MACE and cardiac death and provides incremental prognostic value over conventional risk factors in patients without a history of myocardial infarction or prior coronary artery revascularization. The presence and severity of obstructive CAD detected by CMRA were associated with worse prognosis. Importantly, patients without obstructive CAD on CMRA displayed favorable prognosis.


Assuntos
Doença da Artéria Coronariana , Angiografia por Ressonância Magnética , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Fatores de Risco
5.
J Am Heart Assoc ; 7(3)2018 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-29432130

RESUMO

BACKGROUND: Recent studies using stress-rest perfusion cardiovascular magnetic resonance (CMR) demonstrated a close correlation between myocardial ischemia and reduced fractional flow reserve (FFR). However, its diagnostic concordance may be reduced in patients with multivessel disease. We sought to evaluate the concordance of adenosine stress-rest perfusion CMR for predicting reduced FFR, and to determine the additive value of measuring global coronary flow reserve (CFR) in the coronary sinus in multivessel disease. METHODS AND RESULTS: Ninety-six patients with angiographic luminal narrowing >50% underwent comprehensive CMR study and FFR measurements in 139 coronary vessels. FFR <0.80 was considered hemodynamically significant. Global CFR was quantified as the ratio of stress-rest coronary sinus flow measured by phase-contrast cine CMR. In 25 patients with single-vessel disease, visual assessment of perfusion CMR yielded high diagnostic concordance for predicting flow-limiting stenosis, with the area under receiver operating characteristic curve of 0.93 on a per-patient basis. However, in 71 patients with multivessel disease, perfusion CMR underestimated flow-limiting stenosis, resulting in the reduced area under receiver operating characteristic curve of 0.74. When CFR of <2.0 measured in the coronary sinus was considered as global myocardial ischemia, combined assessment provided correct reclassifications in 7 patients with false-negative myocardial ischemia, and improved the diagnostic concordance to 92% sensitivity and 73% specificity with the area under receiver operating characteristic curve of 0.88 (95% confidence interval, 0.80%-0.97%, P=0.002). CONCLUSIONS: Visual analysis of stress-rest perfusion CMR has limited concordance with FFR in patients with multivessel disease. Multiparametric CMR integrating stress-rest perfusion CMR and flow measurement in the coronary sinus is useful for detecting reduced FFR in multivessel disease.


Assuntos
Adenosina/administração & dosagem , Cateterismo Cardíaco , Doença da Artéria Coronariana/diagnóstico por imagem , Seio Coronário/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Imagem Cinética por Ressonância Magnética , Imagem de Perfusão do Miocárdio/métodos , Vasodilatadores/administração & dosagem , Idoso , Velocidade do Fluxo Sanguíneo , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Seio Coronário/fisiopatologia , Estenose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
6.
J Alzheimers Dis ; 59(3): 951-959, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28697558

RESUMO

Microvascular lesions including cortical microinfarctions (CMIs) and cerebral lobar microbleeds (CMBs) are usually caused by cerebral amyloid angiopathy (CAA) in the elderly and are correlated with cognitive decline. However, their radiological-histopathological coincidence has not been revealed systematically with widely used 3-Tesla (3T) magnetic resonance imaging (MRI). The purpose of the present study is to delineate the histopathological background corresponding to MR images of these lesions. We examined formalin-fixed 10-mm thick coronal brain blocks from 10 CAA patients (five were also diagnosed with Alzheimer's disease, three with dementia with Lewy bodies, and two with CAA only) with dementia and six non CAA patients with neurodegenerative disease. Using 3T MRI, both 3D-fluid attenuated inversion recovery (FLAIR) and 3D-double inversion recovery (DIR) were examined to identify CMIs, and T2* and susceptibility-weighted images (SWI) were examined to identify CMBs. These blocks were subsequently examined histologically and immunohistochemically. In CAA patients, 48 CMIs and 6 lobar CMBs were invariably observed in close proximity to degenerated Aß-positive blood vessels. Moreover, 16 CMIs (33%) of 48 were detected with postmortem MRI, but none were seen when the lesion size was smaller than 1 mm. In contrast, only 1 undeniable CMI was founded with MRI and histopathology in 6 non CAA patients. Small, cortical high-intensity lesions seen on 3D-FLAIR and 3D-DIR images likely represent CMIs, and low-intensity lesions in T2* and SWI correspond to CMBs with in vivo MRI. Furthermore, a close association between amyloid-laden vessels and these microvascular lesions indicated the contribution of CAA to their pathogenesis.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Hemorragia Cerebral/diagnóstico por imagem , Infarto Cerebral/diagnóstico por imagem , Imageamento por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Autopsia , Hemorragia Cerebral/complicações , Infarto Cerebral/complicações , Demência/complicações , Demência/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade
7.
Artigo em Japonês | MEDLINE | ID: mdl-28637960

RESUMO

BACKGROUND: Coronary computed tomography angiography (CCTA) in patients with pacemaker suffers from metallic lead-induced artifacts, which often interfere with accurate assessment of coronary luminal stenosis. The purpose of this study was to assess a frequency of the lead-induced artifacts and artifact-suppression effect by the single energy metal artifact reduction (SEMAR) technique. METHODS: Forty-one patients with a dual-chamber pacemaker were evaluated using a 320 multi-detector row CT (MDCT). Among them, 22 patients with motion-free full data reconstruction images were the final candidates. Images with and without the SMEAR technique were subjectively compared, and the degree of metallic artifacts was compared. RESULTS: On images without SEMAR, severe metallic artifacts were often observed in the right coronary artery (#1, #2, #3) and distal anterior descending branch (#8). These artifacts were effectively suppressed by SEMAR, and the luminal accessibility was significantly improved in #3 and #8. CONCLUSION: While pacemaker leads often cause metallic-induced artifacts, SEMAR technique reduced the artifacts and significantly improved the accessibility of coronary lumen in #3 and #8.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Marca-Passo Artificial , Idoso , Artefatos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Metais
8.
Am J Cardiol ; 119(10): 1542-1547, 2017 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-28335982

RESUMO

The aim of this study was to compare myocardial strain by cardiovascular magnetic resonance feature tracking (CMR-FT) to those derived from displacement encoding with stimulated echoes (DENSE) in patients with acute myocardial infarction (AMI). Twenty patients (65 pa13 years) with AMI underwent cine, DENSE, black-blood T2-weighted and late gadolinium enhancement CMR at 1.5 T. Global and segmental strain was determined by CMR-FT analysis and DENSE on matched 3 short-axis planes. Global circumferential strain by CMR-FT showed a good agreement with that by DENSE (r = 0.85, p <0.001; bias 0.02, limits of agreement -0.03 to 0.06). For segmental circumferential strain, r coefficient between CMR-FT and DENSE was 0.61 (p <0.001) with bias of 0.02, limits of agreement of -0.07 to 0.11. Regional circumferential strain determined by CMR-FT in infarct segments (-0.08 ± 0.05) was significantly altered compared with that in remote normal segments (-0.15 ± 0.05, p <0.001). CMR-FT measurement of regional and global circumferential strain showed good agreement with DENSE in patients with AMI.


Assuntos
Ventrículos do Coração/patologia , Imagem Cinética por Ressonância Magnética/métodos , Contração Miocárdica/fisiologia , Infarto do Miocárdio/diagnóstico , Miocárdio/patologia , Função Ventricular Esquerda/fisiologia , Idoso , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Infarto do Miocárdio/fisiopatologia , Curva ROC , Reprodutibilidade dos Testes
9.
Medicine (Baltimore) ; 95(46): e5410, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27861382

RESUMO

To evaluate the feasibility of a single injection protocol for coronary CT angiography (CTA) and lower extremity CTA in patients suspected for peripheral arterial disease (PAD).This prospective observational study included a total of 103 patients who showed an ankle brachial index ≤0.9 and underwent the single injection protocol for coronary and lower extremity CTA. All CTAs used iodinated contrast (weight × 0.06 mL/s × 20 seconds). A prospective Electrocardiogram (ECG)-gated coronary CTA was performed, followed by helical lower extremity CTA beginning 9 seconds after coronary CTA. Using catheter angiography as reference standard, diagnostic ability of CTA was evaluated.The mean total volume of iodinated contrast used was 70 ±â€Š14 mL. Contrast opacification in the superficial femoral artery was adequate (408 ±â€Š97  Hounsfield Units [HU]) and PAD was detected in 72.8% (75/103). The estimated radiation doses for lower extremity and coronary CTA were 3.6 ±â€Š1.2 and 5.5 ±â€Š4.5 mSv. A significant coronary stenosis was detected in 47 patients (45.6%). Coronary CT image quality was recorded as excellent in 86.4%, acceptable in 11.7%, and unacceptable for 1.9%. Contrast opacification within the superficial femoral artery was adequate in all cases while 27.2% needed an additional scan below the calf to capture the contrast bolus arrival in the smaller lower extremity vessels. Segment based sensitivity, specificity, positive, and negative predictive values were 57.9%, 97.9%, 73.8%, and 95.9% for the coronary CTA, and 63.4%, 91.5%, 76.3%, and 85.3% for peripheral CTA.A single injection protocol for coronary CTA and lower extremity CTA is feasible with a relatively small volume of iodinated contrast.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários , Artéria Femoral , Doença Arterial Periférica/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/uso terapêutico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Eletrocardiografia/métodos , Estudos de Viabilidade , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/patologia , Humanos , Extremidade Inferior/irrigação sanguínea , Masculino , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade
10.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 72(6): 496-502, 2016 Jun.
Artigo em Japonês | MEDLINE | ID: mdl-27320153

RESUMO

BACKGROUND: A clear coronary CT angiography (CCTA) can be obtained when temporal resolution (TR) is shorter than slow filling (SF) duration. The SF duration was calculated by the following equation: SF=-443+0.742 (RR-PQ). Although, the TR of half and full reconstruction using 320-ADCT (0.275 s/r) are known, the TR of automatic patient motion correction (APMC) reconstruction is not clear. The purpose of this study is to clarify the each minimum value of (RR-PQ) for acquiring a clear CCTA that was made by half, full or APMC reconstruction. METHOD: CCTA was performed in consecutive 345 (M/F=195/150, Age: 69±10 years) patients except for arrhythmia and the final heart rate (controlled by ß-blocker) ≥80 bpm using 320-ADCT (Aquilion ONE, 0.275 s/r). In all subjects, 3 CCTAs were generated by half, full, or APMC reconstruction at the same optimal phase. Image quality (A: excellent, B: acceptable, C: poor) was estimated by the consensus of three trained researchers. We classified (RR-PQ) into 15 groups by each 50 ms interval. RESULTS: The A or B % prediction (y) significantly correlated (y=-240.08+0.401x, r=0.98, p=0.0006 in half, y=-238.26+0.378x, r=0.98, p=0.0001 in APMC, and y=-236.84+0.332x, r=0.97, p<0.0001 in full reconstruction) with (RR-PQ) (x), respectively. CONCLUSION: The minimum values of (RR-PQ) for 95% prediction of A or B image quality were ≥836 ms in half, ≥881 ms in APMC, and ≥998 ms in full reconstruction.


Assuntos
Angiografia Coronária/métodos , Movimento (Física) , Tomografia Computadorizada por Raios X/métodos , Idoso , Artefatos , Feminino , Frequência Cardíaca , Humanos , Masculino
11.
Eur J Radiol ; 85(5): 1035-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27130068

RESUMO

PURPOSE: To compare the capability of three-dimensional (3D) T1-weighted turbo field-echo (TFE) black-blood (BB) magnetic resonance imaging (MRI) and turbo-spin echo (TSE) BB MRI for discerning carotid plaques and the difference of signal intensities of the plaques from that of adjacent muscle in patients with cervical carotid stenosis. METHODS: Cervical carotid stenosis was evaluated by 3.0-T MR in 43 patients (38 men and 5 women; age, 36-83 years; mean age, 70 years) during 8 months. The carotid BB MRI comprised 3D T1-weighted TSE BB (T1-TSEBB) and 3D T1-weighted TFE BB (T1-TFEBB) sequences. The delineation of the carotid plaque border was evaluated in comparison with digital subtraction angiography (DSA). The border between the plaque and vessel lumen was rated visually (4-point analysis) and quantitatively (contrast-to-noise ratio). The signal-intensity ratio (SIR) of the plaque to the adjacent muscle was also measured. Data of 3D T1-TSEBB and 3D T1-TFEBB were compared statistically using the Wilcoxon signed-rank test. RESULTS: Visual and quantitative analyses revealed that the border between the plaque and vessel lumen was better delineated on 3D T1-TSEBB MRI than on 3D T1-TFEBB MRI (p<0.01, respectively). SIR of the plaque-to-adjacent muscle was higher on 3D T1- TFEBB MRI than on 3D T1-TSEBB MRI (p<0.05). High signal plaques with a SIR of >1.5 were underestimated on 3D T1-TSEBB MRI. CONCLUSIONS: 3D T1-TSEBB MRI was superior to 3D T1-TFEBB MRI for delineating carotid plaques; however, high signal plaques were underestimated on 3D T1-TSEBB MRI.


Assuntos
Estenose das Carótidas/diagnóstico , Placa Aterosclerótica/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento Tridimensional , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Projetos Piloto , Estudos Retrospectivos , Razão Sinal-Ruído
12.
Eur Heart J Cardiovasc Imaging ; 17(5): 550-6, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26420291

RESUMO

AIMS: Recent study suggests that algorithms such as the Duke Clinical score (DCS) may overestimate the pretest probability. The Agatston score representing the grade of coronary artery calcification can be simply calculated from low-radiation exposure ECG-gated plain CT. In this study, we investigated whether or not more superior diagnostic performance for obstructive coronary artery disease (CAD) can be obtained by combining DCS with the Agatston score. METHODS AND RESULTS: Of 3939 consecutive patients suspected of having stable angina without known CAD who underwent Coronary Computed Tomography Angiography (CCTA) as well as calculation of the DCS and Agatston score at our hospital, 3688 patients were selected as subjects. Obstructive CAD was defined as >50% diameter stenosis on CCTA; we investigated the diagnostic performance based on the area under the curve (AUC) of a receiver operating characteristic (ROC) curve, Net Reclassification Improvement (NRI), and Integrated Discrimination Improvement (IDI). The AUCs of ROCs prepared using the DCS alone and combination of the DCS and Agatston score were 0.7137 and 0.8057, respectively, showing that the diagnostic performance of the combination was significantly superior to DCS alone (P < 0.001). NRI was 0.8132 and IDI was 0.1374, showing that the diagnostic performance was improved by the combination of the DCS and Agatston score compared with DCS alone (P < 0.001). NRI (0.3522) and IDI (0.0287) were improved compared with those of the Agatston score alone (P < 0.001). CONCLUSION: The combination of the DCS and Agatston score improved the diagnostic performance for obstructive CAD compared with DCS alone and Agatston score.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença
13.
Int J Cardiovasc Imaging ; 32(4): 661-70, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26662268

RESUMO

In conventional coronary computed tomography angiography (CCTA), metal artifacts are frequently observed where stents are located, making it difficult to evaluate in-stent restenosis. This study was conducted to investigate whether subtraction CCTA can improve diagnostic accuracy in the evaluation of in-stent restenosis. Subtraction CCTA was performed using 320-row CT in 398 patients with previously placed stents who were able to hold their breath for 25 s and in whom mid-diastolic prospective one-beat scanning was possible. Among these patients, 126 patients (94 men and 32 women, age 74 ± 8 years) with 370 stents who also underwent invasive coronary angiography (ICA) were selected as the subjects of this study. With ICA findings considered the gold standard, conventional CCTA was compared against subtraction CCTA to determine whether subtraction can improve diagnostic accuracy in the evaluation of in-stent restenosis. When non-assessable stents were considered to be stenotic, the diagnostic accuracy in the evaluation of in-stent restenosis was 62.7 % for conventional CCTA and 89.5 % for subtraction CCTA. When the non-assessable stents were considered to be non-stenotic the diagnostic accuracy was 90.3 % for conventional CCTA and 94.31 % for subtraction CCTA. When subtraction CCTA was used to evaluate only the 138 stents that were judged to be non-assessable by conventional CCTA, 116 of these stents were judged to be assessable, and the findings for 109 of them agreed with those obtained by ICA. Even for stents with an internal diameter of 2.5-3 mm, the lumen can be evaluated in more than 80 % of patients. Subtraction CCTA provides significantly higher diagnostic accuracy than conventional CCTA in the evaluation of in-stent restenosis.


Assuntos
Angiografia Digital , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/terapia , Reestenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Artefatos , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/etiologia , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Resultado do Tratamento
14.
Jpn J Radiol ; 34(2): 140-7, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26670593

RESUMO

PURPOSE: To evaluate the role of coronary artery calcium scoring (CACS) and/or coronary CT angiography (CCTA) in asymptomatic elderly patients with high pretest probability for coronary artery disease (CAD). MATERIALS AND METHODS: Forty-eight consecutive asymptomatic elderly (>65 years) subjects who had a high pretest probability and underwent CACS/CCTA were included. Each CCTA was evaluated for adequacy for assessment of coronary stenosis. Significant stenosis (>50% diameter narrowing) was assessed on evaluable CT images and by invasive catheter angiography (ICA). RESULTS: All subjects were men with mean CACS of 880 ± 1779. Among those with low (0-99), intermediate (100-399), and high (400-999) CACS, ICA-verified significant stenosis was present in 8% (1/13), 23% (2/13), and 67% (8/12), respectively. Among those with very high CACS (≥ 1000) (n = 10), 90% of CCTAs were not evaluable for stenosis. CONCLUSION: In asymptomatic elderly subjects with high pretest probability, CACS followed by CCTA may be considered for those with intermediate to high CACS.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador
15.
Magn Reson Med Sci ; 15(3): 340-5, 2016 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-26701697

RESUMO

We propose a simple but novel data acquisition technique for whole-heart coronary magnetic resonance angiography (CMRA). In this technique, the breath-hold chasing MRA, data are collected during breath-hold intervals, with the navigation window manually adjusted to the diaphragmatic level. Compared with the conventional free breathing MRA, this method provided 33% reduction of acquisition time and improved visibility of right coronary artery in 18 normal subjects without any additional software or hardware requirements.


Assuntos
Suspensão da Respiração , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Angiografia por Ressonância Magnética/métodos , Idoso , Circulação Coronária/fisiologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade
16.
Int J Cardiovasc Imaging ; 31(8): 1635-42, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26288954

RESUMO

To investigate the clinical usefulness of subtraction coronary computed tomographic angiography (CCTA) in patients with severe calcification. A 320-row area detector CT system was used in this study. The subjects were 78 patients (47 men and 31 women, 739 years of age) with an Agatston score of >300 who were able to undergo prospective one-beat scanning during a single breath-hold. The CCTA findings were compared against invasive coronary angiography. The diagnostic capabilities of CCTA for the severely calcified segments with and without the additional information provided by subtraction CCTA were compared. Severe calcification was observed in 174 (31.9%) of the 546 segments, and non-assessable regions were observed in 74 (13.6%) of the segments. The addition of subtraction CCTA information improved the diagnostic accuracy for segments with severe calcification from 67.8 to 82.8% on a per-segment basis and from 70.1 to 82.1% on a per-patient basis, with non-assessable segments considered to be stenotic. When non-assessable segments were considered to be an incorrect diagnosis, the diagnostic accuracy was improved from 48.3 to 75.9% on a per-segment basis and from 43.3 to 79.1% on a per-patient basis. In addition, when evaluation was limited to non-assessable segments, subtraction CCTA provided a diagnostic accuracy of 81.1% when non-assessable segments were considered to be stenotic or 66.2% when non-assessable segments were considered to be an incorrect diagnosis. Subtraction CCTA improves the diagnostic capabilities of CCTA in patients with severe calcification.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Técnica de Subtração , Calcificação Vascular/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
17.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 71(3): 237-45, 2015 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-25797667

RESUMO

PURPOSE: The purpose of this study is to validate the clinical usefulness of Advanced Patient Motion Correction (APMC) reconstruction when motion artifacts were observed in a prospective ECG-gated coronary CT angiography (CCTA), which was acquired by low tube current scanning with full reconstruction using 320-row area detector CT (0.275 s/rot.). METHODS: Of 530 consecutive CCTA, we selected 119 patients (M/F: 71/48, Age: 69 ± 11 y, BMI: 23.5 ± 2.5) with (RR-PQ) ≥ 968 ms before scanning, and performed a CCTA with low tube current scanning [30% of usual tube current (30%mA)], adaptive iterative dose reduction 3D, and full reconstruction. Image quality for motion artifacts was subjectively evaluated using a 3-point scale (excellent, acceptable, and unacceptable). RESULTS: Of 119, 102 CCTA had "excellent" images (group A) and 17 had "acceptable" images (group B). The APMC and half reconstruction were retried in the 17 CCTA with "acceptable" images. Finally, all CCTA became "excellent" images. The RR-PQ of group B during scanning (966 ± 80 ms) was significantly (P = 0.0001) shorter than group A (1,088 ± 123 ms). Each image noise (standard deviation of CT value) of aorta, left atrium, and left ventricle was 21.7 ± 2.3, 24.7 ± 2.3, 24.5 ± 2.4 in full, 25.7 ± 2.2, 29.0 ± 3.4, 28.2 ± 2.7 in APMC, and 30.4 ± 2.8, 34.3 ± 4.2, 33.3 ± 2.9 HU in half reconstruction. Mean dose-length product of all patients was 66.2 ± 34.4 mGy · cm. CONCLUSION: "Excellent" CCTA images can be obtained in 85.7% of patients with (RR-PQ)≥ 968 ms by full reconstruction. APMC is useful for motion artifacts and image noise reduction when patient' s HR increases during scanning rather than half reconstruction.


Assuntos
Angiografia Coronária/métodos , Eletrocardiografia , Tomografia Computadorizada por Raios X/métodos , Idoso , Artefatos , Angiografia Coronária/instrumentação , Feminino , Humanos , Masculino , Movimento (Física) , Tomografia Computadorizada por Raios X/instrumentação
18.
Jpn J Radiol ; 33(3): 122-30, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25626571

RESUMO

PURPOSE: To clarify the frequency and distribution pattern of calcifications in all and in only non-assessable coronary arterial segments in symptomatic patients with coronary heart disease. MATERIALS AND METHODS: Among 2355 consecutive coronary CT angiographies performed using a 320-row ADCT, 1129 studies performed by prospective one-beat scanning without metallic and motion artifacts were evaluated. Frequency and degree of calcification were assessed for each coronary segment. Evaluations were performed in all and in only non-assessable segments, and the results were compared. RESULTS: Calcified segments were observed in 15.6 % of patients and 2.4 % of segments. The most extensively calcified segments were those in the proximal left anterior descending branch. 1.1 % of all of the segments were not assessable due to calcification, and 90 % of those non-assessable segments had high-grade calcifications. When the calcium score value was 1000 or 2000, the expected frequency of non-assessable segments was 27.5 or 53.5 %, respectively. CONCLUSION: There were specific features of the distribution of coronary arterial calcifications. It is important to be familiar with these features when deciding whether or not to perform subtraction CCTA.


Assuntos
Angiografia Coronária , Tomografia Computadorizada por Raios X , Calcificação Vascular/diagnóstico por imagem , Artefatos , Estudos de Coortes , Angiografia Coronária/instrumentação , Doença das Coronárias/diagnóstico por imagem , Humanos , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X/instrumentação
19.
Heart Vessels ; 30(5): 563-71, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24770610

RESUMO

Existing methods to calculate pre-test probability of obstructive coronary artery disease (CAD) have been established using selected high-risk patients who were referred to conventional coronary angiography. The purpose of this study is to develop and validate our new method for pre-test probability of obstructive CAD using patients who underwent coronary CT angiography (CTA), which could be applicable to a wider range of patient population. Using consecutive 4137 patients with suspected CAD who underwent coronary CTA at our institution, a multivariate logistic regression model including clinical factors as covariates calculated the pre-test probability (K-score) of obstructive CAD determined by coronary CTA. The K-score was compared with the Duke clinical score using the area under the curve (AUC) for the receiver-operating characteristic curve. External validation was performed by an independent sample of 319 patients. The final model included eight significant predictors: age, gender, coronary risk factor (hypertension, diabetes mellitus, dyslipidemia, smoking), history of cerebral infarction, and chest symptom. The AUC of the K-score was significantly greater than that of the Duke clinical score for both derivation (0.736 vs. 0.699) and validation (0.714 vs. 0.688) data sets. Among patients who underwent coronary CTA, newly developed K-score had better pre-test prediction ability of obstructive CAD compared to Duke clinical score in Japanese population.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Intensificação de Imagem Radiográfica/métodos , Medição de Risco , Idoso , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Probabilidade , Curva ROC , Estudos Retrospectivos , Índice de Gravidade de Doença
20.
J Cardiovasc Comput Tomogr ; 8(3): 198-204, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24939068

RESUMO

BACKGROUND: The Duke clinical score (DCS) is commonly used to estimate the pretest probability of coronary artery disease (CAD). However, the criterion was developed in a population undergoing catheter angiography. OBJECTIVE: To test the hypothesis that DCS overestimates the CAD probability when applied to patients evaluated with coronary CT angiography (CCTA). A second objective is to compute an adjustment of the calculated DCS to apply to this population. METHODS: The DCS was calculated for the 3996 consecutive CCTA studies (February 2009 to April 2013) performed for symptomatic patients with no known CAD. Performance of the DCS for the detection of CAD was evaluated by the area under the receiver operating characteristic curve. Using the training cohort (n = 2789), a linear regression line between the calculated probability and the observed prevalence of CAD identified a modified DCS cutoff for a better risk categorization; this was internally validated by a separate cohort (n = 1207). RESULTS: The DCS showed a good discrimination (area under the receiver operating characteristic curve = 0.71) for the detection of CAD (prevalence = 23.3%). The calibration analysis showed an overall 2.4-fold overestimation by DCS with a DCS < 23% corresponding to the low-risk category (ie, observed prevalence of CAD < 10%). There was no appropriate DCS cutoff to define high-risk category (ie, prevalence > 90%). The validation cohort showed a prevalence of 9.4% when DCS < 23% was used to define low risk. CONCLUSION: Among patients who underwent CCTA, DCS overestimated the pretest probability by at least 2-fold; the DCS < 23% should define the lower risk probability. The DCS poorly identifies high-risk population and thus development of new CCTA-based criteria is warranted.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Japão , Masculino , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA