Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Cardiothorac Surg ; 19(1): 212, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38616278

RESUMO

BACKGROUND: A ruptured thoracoabdominal aortic aneurysm (rTAAA) represents a considerable challenge for surgeons. To date, endovascular procedures have not been able to completely replace open repair when debranching is required. CASE PRESENTATION: A 73-year-old man was admitted to our hospital after complaining of left lateral abdominal pain. Enhanced computed tomography revealed a left retroperitoneal hematoma and a large, ruptured Crawford type IV TAAA. We first performed emergency resuscitative surgery to close the lacerated foramen. A graft replacement was performed 1 month after the initial surgery when the patient had stabilized. At 5 years postoperatively, neither occlusion nor anastomotic pseudoaneurysm was noted on computed tomography. CONCLUSIONS: We provide an update on the perioperative management of patients undergoing open rTAAA repair. This procedure can be considered to ensure complete repair of an rTAAA.


Assuntos
Falso Aneurisma , Aneurisma da Aorta Toracoabdominal , Ruptura Aórtica , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Anastomose Cirúrgica
2.
Heart Vessels ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38592490

RESUMO

The use of thoracic endovascular aortic repair (TEVAR) for thoracic aortic aneurysm (TAA) and Stanford type B aortic dissection (TBAD) has been increasing; however, in terms of etiology, the differences of long term after TEVAR outcomes remain unexplored. Thus, we investigated etiology-specific long-term results of TEVAR for TAA and TBAD. A total of 421 TEVAR procedures were performed at our institution from July 2007 to December 2021; 249 TAA cases and 172 TBAD cases were included. Traumatic aortic dissection and aortic injury cases were excluded. The mean observation duration was 5.7 years. The overall 30-day mortality rate was 1.4% (n = 6), with 1.2% (n = 3) in the TAA group and 1.7% (n = 3) in the TBAD group. The overall incidence of postoperative stroke was 0.9% (n = 4), with 1.2% (n = 3) and 0.6% (n = 1) in the TAA and TBAD groups, respectively (p = 0.90). Paraplegia developed in 1.7% (n = 7) of patients, with 2.4% (n = 6) in the TAA group and 0.6% (n = 1) in the TBAD group. Freedom from aortic-related death was not significantly different between the two etiologies; however, thoracic reintervention was more common in the TBAD group (p = 0.003), with endoleak being the most common indication for reintervention. Additionally, retrograde type A aortic dissection occurred in four TBAD cases, while migration occurred in three TAA cases. The perioperative results of TEVAR for TAA and TBAD were satisfactory. The long-term results were unfavorable owing to the occurrence of etiology-specific and common complications. In terms of the high frequency of reintervention, the long-term complications associated with TEVAR are etiology specific.

3.
Heart Vessels ; 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38536509

RESUMO

Medical management is the standard treatment of chronic type B aortic dissection (CTBAD). However, the roles of open surgical repair (OSR) and thoracic endovascular repair (TEVAR) in patients with CTBAD remain controversial. Thus, this study aimed to assess and compare the mid- and long-term clinical outcomes of OSR via left thoracotomy with that of TEVAR for CTBAD. The data of 85 consecutive patients who underwent surgery for CTBAD from April 2007 to May 2021 were retrospectively reviewed. The patients were divided into two groups: Group G, which included patients who underwent OSR, and Group E, which included patients who underwent TEVAR. Groups G and E comprised 33 and 52 patients, respectively. Preoperative and postoperative computed tomography (CT) studies were retrospectively analyzed for the maximum diameter. The mean duration of the follow-up period was 5.8 years. Operative mortality did not occur. There was no difference in complications, such as stroke (G: 2 vs. E: 0, p = 0.30), paraplegia (G: 1 vs. E: 1, p = 0.66), and respiratory failure (G: 2, vs. E: 0, p = 0.30). The difference in preoperative factors was observed, including the intervals between onset and operation (G; 4.9 years vs. E; 1.9 years, p < 0.01), maximum diameter in preoperative CT (G; 59.0 mm vs. E; 50.5 mm, p < 0.001), and maximum false lumen diameter (G; 35.5 mm vs. E; 29.0 mm, p < 0.01). There was no significant difference in the mid- and long-term survival rates (p = 0.49), aorta-related deaths (p = 0.33), and thoracic re-intervention rates (p = 0.34). Postoperative adverse events occurred in Group E: four cases of retrospective type A aortic dissection, two cases of aorto-bronchial fistula, and one case of aorto-esophagus fistula. Aorta-related death and re-intervention rates crossed over in both groups after seven years postoperatively. Although endovascular repair of CTBAD is less invasive, the rate of freedom from re-intervention was unsatisfactory. Some fatal complications were observed in the endovascular group, and the mid- and long-term outcomes were reversed compared with those in the OSR group. Although OSR is an invasive procedure, it could be performed safely without perioperative complications. OSR has more feasible mid- and long-term outcomes.

4.
Eur Heart J Case Rep ; 7(8): ytad392, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37637100

RESUMO

Background: Mechanisms of paravalvular leak (PVL) after mitral valve replacement have not been fully delineated. Herein, we report a case of structures on the ventricular side of the mitral valve in a patient with an extremely late PVL. Case summary: A 68-year-old female underwent aortic and mitral valve replacement with a mechanical valve 29 years ago. She was in good health for 28 years. However, exertional dyspnoea appeared 8 months ago. She was admitted to our hospital for congestive heart failure and haemolytic anaemia. Echocardiography showed severe regurgitation due to PVL of the mitral valve. The fluoroscopy showed that a circular calcification was found below the mitral prosthesis. The operation was performed through a median sternotomy. After the aortic cross-clamp, the aortic mechanical valve was removed. The ventricular side of the mitral valve was inspected with the endoscope through the aortic annulus before manoeuvers were performed in the mitral valve. A gap was seen between the prosthetic valve and annular tissue and subvalvular calcification. A bioprosthetic valve was placed with a modified collar-reinforcement technique using a xenopericardium strip. The postoperative course was uneventful. PVL and haemolysis completely disappeared. Discussion: The ventricular side of the prosthetic valve could be observed before the mitral valve was removed. Not only the protruding circular calcification and displacement of the prosthetic valve to the atrial side but also the loss of adhesion and adhesive nature of the annular tissue played a definitive role in the late PVL occurrence and recurrence after percutaneous or surgical repair.

5.
J Artif Organs ; 26(3): 233-236, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36002644

RESUMO

Fulminant myocarditis is a fatal development from profound biventricular heart failure and often requires both right- and left-ventricular assistance to maintain hemodynamics, even at the risk of increased mortality and morbidity. Here, we present a 42-year-old female with profound biventricular failure due to fulminant myocarditis, resolved by an isolated durable left-ventricular assist device support under a fenestrated, Fontan-like circulation and managed low-pulmonary vascular resistance.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Miocardite , Feminino , Humanos , Adulto , Miocardite/complicações , Miocardite/cirurgia , Resultado do Tratamento , Insuficiência Cardíaca/cirurgia , Hemodinâmica , Choque Cardiogênico
6.
J Cardiothorac Surg ; 17(1): 264, 2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-36217166

RESUMO

BACKGROUND: The flow capacity of the in situ internal thoracic artery (ITA) is not necessarily sufficient and can be a cause of hypoperfusion syndrome. We present a catastrophic case of in situ ITA grafting for an isolated left main trunk obstruction 13 years after the modified Bentall operation. CASE PRESENTATION: A 33-years-old woman had undergone the modified Bentall operation. Coronary angiography showed a critical stenosis in the left coronary artery. The patient underwent emergency off-pump coronary artery bypass graft with the left ITA to the left anterior descending artery (LAD). On the 7th day, the patient had severe dyspnoea and hypotension. Catheter angiography showed that the ITA was patent; however, blood flow from the in situ ITA was delayed, and reversal flow from the apex to the proximal LAD was found. The patient underwent implantation of a left ventricular assist device. CONCLUSIONS: Concomitant aortocoronary bypass to the circumflex branch will minimise the risk of hypoperfusion, especially for young patients without atherosclerotic disease.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Artéria Torácica Interna , Adulto , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Feminino , Humanos , Anastomose de Artéria Torácica Interna-Coronária , Artéria Torácica Interna/cirurgia , Grau de Desobstrução Vascular
7.
JTCVS Open ; 11: 14-22, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36172444

RESUMO

Objective: We aimed to determine the efficacy of total arch replacement with stented elephant trunk by comparing it with hemiarch replacement with and without open stent graft for acute aortic dissection type 1. Methods: We reviewed records of 177 patients who underwent hemiarch replacement (HAR group) (concomitant open stent, 125) and 98 patients who underwent total arch replacement (TAR group) (concomitant stented elephant trunk, 91) for acute type 1 dissection. Compared with the TAR group, the HAR group was older (68.1 vs 60.9 years; P < .01) and had more thrombosed false lumen (28.8% vs 4.1%, P < .01). Results: In-hospital death occurred for 7 patients in the HAR group and 1 patient in the TAR group (P = .17). More patients in the TAR group had a postoperative thrombosed false lumen, compared with the HAR group (68% vs 54%, P = .03). In patients with preoperative nonthrombosed false lumen in the HAR group, the rate of postoperative thrombosis was significantly lower than with versus without an open stent (31% vs 65%, P = .01). The rate of freedom from an aortic arch event in the TAR group at 5 years was significantly greater than that in the HAR group (100% vs 83.7%, P = .01). Conclusions: Stented elephant trunk with TAR provided a high rate of false lumen thrombosis and a low incidence of arch events, whereas an open stent during HAR was not beneficial in terms of false lumen thrombosis and arch event prevention.

8.
Heart Lung Circ ; 31(10): 1399-1407, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35840512

RESUMO

BACKGROUND: In coronary artery bypass grafting (CABG) for haemodialysis patients, arteriovenous fistula can reduce blood flow from the internal mammary artery (IMA) graft. The purpose of this study was to delineate the rationale of ipsilateral IMA grafting to the arteriovenous fistula by assessing graft flow and patency. METHOD: The clinical records of 139 haemodialysis patients who underwent off-pump CABG, including IMA grafting to the left anterior descending artery (LAD) between April 2007 and December 2018, were retrospectively reviewed. Clinical outcomes and transit-time flowmetry results of IMA to LAD bypass grafts during off-pump CABG and postoperative angiography were examined. RESULTS: An ipsilateral IMA to the arteriovenous fistula (Ipsi-IMA) was used in 89 patients, and a contralateral IMA to the arteriovenous fistula (Contra-IMA) was used in 50 patients and no hospital deaths occurred. The mean graft flow and angiographic patency rate did not differ between the Ipsi-IMA and Contra-IMA groups. In patients with 51 to 90% stenosis of LAD, there was no significant difference in the mean graft flow. In comparison, in the patients with 91 to 100% stenosis of LAD, the mean graft flow in the Ipsi-IMA group was significantly lower than that in the Contra-IMA group (p=0.03). Kaplan-Meier analyses showed a 5-year survival rate of 57.6% for Ipsi-IMA and 64.8% for Contra-IMA (p=0.47). CONCLUSIONS: In the revascularisation of the LAD, the graft patency rate of the Ipsi-IMA was not inferior to that of the Contra-IMA. However, when the LAD has 91 to 100% stenosis, a Contra-IMA to arteriovenous fistula may be beneficial in terms of sufficient flow capacity.


Assuntos
Fístula Arteriovenosa , Artéria Torácica Interna , Fístula Arteriovenosa/diagnóstico , Fístula Arteriovenosa/cirurgia , Constrição Patológica , Ponte de Artéria Coronária/métodos , Humanos , Artéria Torácica Interna/transplante , Estudos Retrospectivos , Grau de Desobstrução Vascular
9.
Artigo em Inglês | MEDLINE | ID: mdl-35179581

RESUMO

OBJECTIVES: Total arch replacement (TAR) using an endovascular approach has been initially introduced as the frozen elephant trunk technique (FET). In our institute, TAR using the FET with Frozenix has been used as the first-line treatment for distal aortic arch aneurysms since 2014. This study aimed to evaluate the early and long-term outcomes and demonstrate the efficacy of this procedure. METHODS: Between 2014 and 2021, 121 consecutive patients were treated with TAR using the FET with Frozenix for distal aortic arch aneurysms. Early and long-term outcomes were retrospectively analysed. RESULTS: The 30-day mortality rate was 2.5% (3/121). Of postoperative complications, paraplegia due to spinal cord injury occurred in 2 (1.7%) patients, stroke in 12 (9.9%) and acute renal failure in 10 (8.3%). At follow-up, 23 secondary aortic interventions were required and 8 (6.6%) patients underwent intended secondary thoracic endovascular aortic repair for residual descending aortic aneurysm. Late and aortic-related deaths occurred in 16 (13.2%) and 4 (3.3%) patients, respectively. The overall long-term survival rates at 1, 3 and 5 years were 87.6%, 83.1% and 65.4%, respectively, while the rates of freedom from aortic-related death at 1, 3 and 5 years were 95.7%, 95.7% and 84.8%, respectively. CONCLUSIONS: TAR using the FET with Frozenix for distal aortic arch aneurysms has acceptable early mortality and morbidity. Spinal cord injury and paraplegia occur less frequently than previously reported. The technique has satisfactory long-term survival and freedom from aortic-related death.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma Aórtico , Dissecção Aórtica , Implante de Prótese Vascular , Traumatismos da Medula Espinal , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma Aórtico/cirurgia , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Humanos , Paraplegia/etiologia , Estudos Retrospectivos , Traumatismos da Medula Espinal/etiologia , Resultado do Tratamento
10.
BMC Cardiovasc Disord ; 22(1): 54, 2022 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-35172726

RESUMO

BACKGROUND: Extracorporeal left ventricular assist device is often required for acute myocardial infarction patients in cardiogenic shock when temporary mechanical circulatory support fails to provide hemodynamic stabilization. This study aimed to evaluate the clinical outcomes of acute myocardial infarction patients in cardiogenic shock supported by an extracorporeal left ventricular assist device. METHODS: This retrospective study enrolled 13 acute myocardial infarction patients in cardiogenic shock treated with an extracorporeal left ventricular assist device from April 2011 to July 2020. RESULTS: Twelve (92.3%) and eleven (84.6%) patients were supported using venoarterial extracorporeal membrane oxygenation and intra-aortic balloon pumping before implantation, respectively. The median duration from acute myocardial infarction to extracorporeal left ventricular assist device implantation was 7 (3.5-24.5) days. The overall in-hospital mortality rate was 30.8% (n = 4). Extracorporeal left ventricular assist device was explanted in one patient for cardiac recovery; eight (61.5%) patients were approved as heart transplant candidates in whom the extracorporeal left ventricular assist device was exchanged for a durable left ventricular assist device; two (15.4%) expired while waiting for a heart transplant, and two (15.4%) received a successful transplant. The 1- and 3-year overall survival rates after extracorporeal left ventricular assist device implantation were 68.3% and 49.9%, respectively. CONCLUSIONS: The operative mortality after extracorporeal left ventricular assist device implantation in acute myocardial infarction patients in cardiogenic shock was favorable. Our strategy of early hemodynamic stabilization with extracorporeal left ventricular assist device implantation in these patients as a bridge-to-bridge therapy was effective in achieving better survival.


Assuntos
Oxigenação por Membrana Extracorpórea/instrumentação , Transplante de Coração , Coração Auxiliar , Hemodinâmica , Infarto do Miocárdio/cirurgia , Choque Cardiogênico/cirurgia , Função Ventricular Esquerda , Listas de Espera , Adolescente , Adulto , Remoção de Dispositivo , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/fisiopatologia , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/mortalidade , Choque Cardiogênico/fisiopatologia , Fatores de Tempo , Tempo para o Tratamento , Resultado do Tratamento , Listas de Espera/mortalidade , Adulto Jovem
11.
J Cardiothorac Surg ; 15(1): 311, 2020 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33046086

RESUMO

BACKGROUND: In individuals with hypertrophic obstructive cardiomyopathy, elongated anterior mitral leaflets are commonly associated with systolic anterior motion. In patients with mild septal hypertrophy, a myectomy is considered insufficient to relieve systolic anterior motion and left ventricular outflow tract obstruction. CASE PRESENTATION: In the patient, who had relatively mild septal hypertrophy, the section of the anterior leaflet protruding into the left ventricular outflow tract was resected, concomitant with septal myectomy and the relocation of the papillary muscles. An edge-to-edge stitch was placed at the uppermost segment of the coaptation zone. Using these manoeuvres, systolic anterior motion, left ventricular outflow tract obstruction and mitral regurgitation were successfully resolved postoperatively. CONCLUSIONS: We describe a surgical technique with an edge-to-edge suture for the resection of an elongated anterior mitral leaflet. In combination with septal myectomy and relocation of the papillary muscles, this technique is a simple and viable option, especially when septal hypertrophy is not severe.


Assuntos
Cardiomiopatia Hipertrófica/cirurgia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Idoso , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Procedimentos Cirúrgicos Cardiovasculares , Ecocardiografia , Feminino , Humanos , Valva Mitral/anormalidades , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Técnicas de Sutura , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem
12.
J Cardiothorac Surg ; 15(1): 312, 2020 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33046087

RESUMO

BACKGROUND: Annular dilation by left atrial remodeling is considered the main cause of atrial function mitral regurgitation. Although acceptable outcomes have been obtained using mitral ring annuloplasty alone for atrial functional mitral regurgitation, data assessing outcomes of this procedure are limited. Therefore, we aimed to assess midterm outcomes of mitral valve repair in patients with atrial functional mitral regurgitation. METHODS: We retrospectively studied 40 patients (mean age: 69 ± 9 years) who had atrial fibrillation that persisted for > 1 year, preserved left ventricular ejection fraction of > 40%, and mitral valve repair for atrial functional mitral regurgitation. The mean clinical follow-up duration was 42 ± 24 months. RESULTS: Mitral ring annuloplasty was performed for all patients. Additional repair including anterior mitral leaflet neochordoplasty was performed for 22 patients. Concomitant procedures included maze procedure in 20 patients and tricuspid ring annuloplasty in 31 patients. Follow-up echocardiography showed significant decreases in left atrial dimensions and left ventricular end-diastolic dimensions. Recurrent mitral regurgitation due to ring detachment or leaflet tethering was observed in five patients and was seen more frequently among those with preoperative left ventricular dilatation. Three patients without tricuspid ring annuloplasty or sinus rhythm recovery by maze procedure developed significant tricuspid regurgitation. Five patients who underwent the maze procedure showed sinus rhythm recovery. Rates of freedom from re-admission for heart failure at 1 and 5 years after surgery were 95 and 86%, respectively. CONCLUSIONS: Mitral valve repair is not sufficient to prevent recurrent atrial functional mitral regurgitation in patients with preoperative left ventricular dilatation. Tricuspid ring annuloplasty may be required for long-term prevention of significant tricuspid regurgitation.


Assuntos
Fibrilação Atrial/cirurgia , Insuficiência Cardíaca/etiologia , Insuficiência da Valva Mitral/cirurgia , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Resultado do Tratamento
13.
Eur J Cardiothorac Surg ; 58(4): 707-713, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32236552

RESUMO

OBJECTIVES: We evaluated the operative and long-term outcomes of the frozen elephant trunk (FET) technique for acute type A aortic dissection. METHODS: This study evaluated 426 consecutive patients who underwent aortic repair for acute type A aortic dissection from June 2007 to December 2018 at our centre. Of these, 139 patients underwent total arch replacement with FET (FET group), and 287 underwent other procedures (no FET group). Ninety-two patients in the FET group were matched to 92 patients in the no FET group by using propensity score matching analysis. RESULTS: Thirty-day mortality and neurological dysfunction were not significantly different between the FET and no FET groups (1.4% vs 2.4%, P = 0.50 and 5.0% vs 6.3%, P = 0.61, respectively). Long-term survival was better in the FET group than in the no FET group (P = 0.008). Freedom from distal thoracic reintervention was similar in the FET and no FET groups (P = 0.74). In the propensity-matched patients, freedom from aortic-related death was better in the FET group than in the no FET group (P = 0.044). CONCLUSIONS: Operative outcomes showed no significant difference between the 2 groups. FET contributes to better long-term survival in patients with acute type A aortic dissection.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Humanos , Estudos Retrospectivos
14.
Ann Thorac Surg ; 109(1): 86-92, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31336064

RESUMO

BACKGROUND: The Trifecta valve (Abbott, St Paul, MN) has excellent hemodynamic performance with acceptable rates of freedom from structural valve degeneration. However, some recent studies have reported early Trifecta valve failure. Here, we report a case series of seven Trifecta valve failures with a review of the literature. METHODS: Of 107 implantations of Trifecta bioprostheses between 2012 and 2014, we encountered seven Trifecta valve failures (6.5%). Failure of a 19-mm Trifecta valve occurred in 1 patient, failure of a 21-mm Trifecta valve occurred in 5 patients, and failure of a 23-mm Trifecta valve occurred in 1 patient. The mean duration of valve durability was 51 ± 16 months. The mean effective orifice area index on the first echocardiogram after Trifecta valve implantation was 0.96 ± 0.26. The mode of presentation was prosthetic valve stenosis in 3 patients and severe aortic regurgitation in 4 patients. RESULTS: Six patients underwent redo surgical aortic valve replacement. The common pathologic findings were circumferential pannus formation with noncoronary cusp tear and leaflet calcification. The rates of preoperative end-renal stage disease and postoperative prosthesis-patient mismatch were higher in patients with Trifecta valve failure. The incidence of early Trifecta valve failure was 3.1% at 48 months and 13.1% at 72 months. CONCLUSIONS: In our experience, early Trifecta valve failure was caused by cusp tears or leaflet calcification. Patients with end-renal stage disease and prosthesis-patient mismatch should be closely followed. Some patients with cusp tears may require urgent surgery.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/cirurgia , Falha de Prótese , Idoso , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos
15.
J Cardiothorac Surg ; 14(1): 205, 2019 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-31775821

RESUMO

BACKGROUND: Good mid-term durability of mitral valve repair of bileaflet lesions has been reported; however, patients may develop failure during follow-up. This study assessed late outcomes and mechanisms of failure associated with mitral valve repair of bileaflet lesions. METHODS: Fifty-six patients (mean age 67 ± 12 years) underwent mitral valve repair of bileaflet lesions due to degenerative disease in 2011-2018. Mitral annuloplasty was added to all procedures except for 1 patient with annular calcification. Mitral valve lesions were identified by surgical inspection. Mean clinical and echocardiography follow-up occurred at 2.7 ± 2.1 and 2.5 ± 1.9 years, respectively. RESULTS: Additional mitral valve repair techniques involved triangular resection (n = 15 patients), quadrangular resection with sliding plasty (n = 12), neochordoplasty (n = 52), and commissural plication (n = 26). Prolapse of ≥2 anterior and posterior leaflet scallops occurred in 22 (39%) and 30 (54%) patients, respectively. During follow-up, 10 (17.8%) patients developed moderate or severe mitral regurgitation. Whereas prolapse or tethering was observed early after neochordoplasty or quadrangular resection, recurrent regurgitation occurred late after commissural repair. Five-year freedom from recurrent moderate or severe mitral regurgitation rates was 71.1 ± 11.0%. CONCLUSIONS: Seventeen percent of patients developed recurrent mitral regurgitation during follow-up. Repair failure in the early phase occurred owing to aggressive resection of the posterior mitral leaflet or maladjustment of the artificial neochordae. Recurrent mitral regurgitation might occur in the late phase even after acceptable commissural repair. A sequential approach may be useful to improve the quality of mitral valve repair in bileaflet lesions.


Assuntos
Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/patologia , Prolapso da Valva Mitral/diagnóstico , Prolapso da Valva Mitral/patologia , Recidiva , Resultado do Tratamento
16.
Innovations (Phila) ; 14(6): 537-544, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31619102

RESUMO

OBJECTIVE: To delineate the efficacy and safety of transthoracic cannulation to the ascending aorta through a right pleural cavity during minimally invasive cardiac surgery (MICS). METHODS: We retrospectively assessed the records of 104 patients who underwent MICS in our institution between December 2011 and December 2018. Procedures included mitral valve repair (88 patients), aortic valve replacement (8 patients), atrial septal defect closure (6 patients), and myxoma resection (2 patients). Aortic valve replacements were performed through the third intercostal space (ICS), whereas the other procedures were mainly performed through the fourth ICS. The femoral group comprised 60 patients in whom an artificial graft was anastomosed to the femoral artery and 4 who underwent cannulation into the femoral artery. The aorta group comprised 40 patients in whom transthoracic cannulation was performed through the second or third ICS, separate from the main skin incision. RESULTS: No mortality or critical complications were associated with cardiopulmonary bypass. Perfusion pressure measured at outflow of the artificial lung (224 ± 43 vs. 190 ± 42; P < 0.001) and pump pressure measured at the outflow of the pump (293 ± 50 vs. 255 ± 57; P < 0.001) were significantly higher in the femoral group than in the aorta group. The skin incision lengths were similar (56.9 ± 6.9 vs. 55.1 ± 6.0 mm; P = 0.107). CONCLUSIONS: Transthoracic cannulation into the ascending aorta is reliable and can be safely performed. The possible risks associated with peripheral cannulation and retrograde perfusion can be avoided thereafter.


Assuntos
Aorta/cirurgia , Procedimentos Cirúrgicos Cardíacos/instrumentação , Cateterismo/métodos , Artéria Femoral/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Idoso , Ponte Cardiopulmonar/métodos , Ponte Cardiopulmonar/estatística & dados numéricos , Cateterismo/efeitos adversos , Feminino , Átrios do Coração/cirurgia , Neoplasias Cardíacas/cirurgia , Comunicação Interatrial/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Valvas Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Mixoma/cirurgia , Perfusão/métodos , Perfusão/tendências , Pressão/efeitos adversos , Estudos Retrospectivos , Segurança , Ferida Cirúrgica/epidemiologia , Resultado do Tratamento
17.
Transplant Proc ; 51(9): 3174-3177, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31619345

RESUMO

A 19-year-old Asian woman presented to the emergency department with ventricular fibrillation. Emergent coronary angiography revealed a 99% ostial stenosis of the left main coronary trunk, and percutaneous coronary intervention was performed. Takayasu arteritis was suspected, but fluorodeoxyglucose positron emission tomography scanning showed no active inflammation. Cardiac function was affected by ischemic cardiomyopathy, and an extracorporeal left ventricular assisted device was implanted under INTERMACS profile 1 status. Histopathology of the ascending aortic wall at the outflow anastomosis site showed no significant sign of Takayasu arteritis. The absence of systemic inflammation led to the replacement of the extracorporeal left ventricular assisted device with a Jervik 2000 as a bridge to transplant. An orthotropic heart transplant took place after a 39-month wait. Histopathology of the explanted heart revealed intimal and adventitial thickening with destruction of the elastic lamina localized at the sinus of Valsalva. Our final pathologic diagnosis was localized Takayasu arteritis. To counter the increased risk of stenosis or pseudoaneurysm formation at the vascular anastomosis site, anti-inflammatory therapy was essential in Takayasu arteritis. The post-heart transplant immunosuppression regime was considered stronger than that for Takayasu arteritis, and we therefore administered prednisolone, mycophenolate mofetil, and tacrolimus as standard protocol. There have been no signs of either relapse or rejection of transplantation for over 1 year. Further closed observation is required to clarify the long-term outcome of this rare condition with regard to heart transplantation.


Assuntos
Cardiomiopatias/etiologia , Cardiomiopatias/cirurgia , Transplante de Coração , Seio Aórtico/patologia , Arterite de Takayasu/complicações , Arterite de Takayasu/patologia , Feminino , Coração Auxiliar , Humanos , Isquemia Miocárdica/etiologia , Isquemia Miocárdica/cirurgia , Adulto Jovem
18.
Gen Thorac Cardiovasc Surg ; 67(8): 655-660, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30737658

RESUMO

OBJECTIVES: We investigated current mechanisms causing low graft flow (LGF) following coronary artery bypass grafting, particularly for the right coronary artery (RCA). METHODS: We retrospectively assessed 230 individual bypass grafts as the sole bypass graft for the RCA using preoperative and postoperative quantitative angiography. Overall, 155 in-situ gastroepiploic arteries (GEAs) and 75 saphenous vein grafts (SVGs) were included. The size and status of the revascularised area were examined to determine whether these factors were associated with LGF (defined as ≤ 20 mL/min with intraoperative flowmetry). A distal lesion was defined as stenosis at segment #4, whereas a proximal lesion was stenosis at #1, #2 and #3. RESULTS: Graft flow in the SVG and the GEA for distal lesion was significantly less compared with that for proximal lesion (34 ± 26 vs. 60 ± 46, p < 0.0001 and 22 ± 12 vs. 43 ± 28, p = 0.0004, respectively). For proximal lesion, LGF was significantly more frequent when the minimal luminal diameter was over 1.27 compared with when it was less than 1.27 (p = 0.02). Prior myocardial infarction significantly correlated with LGF in the GEA (p = 0.007) and the SVG (p = 0.03). In 55 bypass grafts with LGF, the causes were competitive flow in 20.0%, small revascularised area in 38.1% and prior myocardial infarction in 32.7%. CONCLUSIONS: Along with the current strategy based on the severity of native coronary stenosis, the incidence of competitive flow decreased remarkably. This resulted in flow demand, myocardial status and collateral vessels more influential on graft patency.


Assuntos
Ponte de Artéria Coronária , Estenose Coronária/cirurgia , Vasos Coronários/fisiologia , Artéria Gastroepiploica/transplante , Veia Safena/transplante , Idoso , Velocidade do Fluxo Sanguíneo/fisiologia , Prótese Vascular , Angiografia Coronária/métodos , Estenose Coronária/fisiopatologia , Vasos Coronários/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio , Miocárdio , Período Pós-Operatório , Fluxo Sanguíneo Regional/fisiologia , Estudos Retrospectivos , Grau de Desobstrução Vascular
19.
Ann Vasc Surg ; 57: 272.e5-272.e7, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30684611

RESUMO

An aortic diverticulum, including Kommerell's diverticulum, is an uncommon, congenital, aortic arch anomaly. Surgery for a diverticulum is challenging, and several surgical strategies have been reported. Here, we present the case of an asymptomatic 57-year-old man who was referred to our hospital. Computed tomography revealed right aortic arch and aortic diverticulum, and he underwent distal limited open stenting under hypothermic circulatory arrest with selective cerebral perfusion via median sternotomy. The postoperative course was uneventful. Thus, this report shows that our procedure is useful and safe for treating aortic diverticulum.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Divertículo/cirurgia , Procedimentos Endovasculares/instrumentação , Stents , Aorta Torácica/anormalidades , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Aortografia/métodos , Prótese Vascular , Angiografia por Tomografia Computadorizada , Divertículo/diagnóstico por imagem , Parada Cardíaca Induzida/métodos , Humanos , Hipotermia Induzida , Masculino , Pessoa de Meia-Idade , Perfusão/métodos , Esternotomia , Resultado do Tratamento
20.
J Cardiothorac Surg ; 13(1): 121, 2018 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-30466471

RESUMO

BACKGROUND: The aim of this study was to delineate impacts of percutaneous coronary intervention (PCI), flow demand, and status of myocardium on graft flow. METHODS: We retrospectively assessed 736 individual coronary artery bypass grafts that had been created as the sole bypass graft for a vascular region in 405 patients. The grafts comprised 334 internal thoracic artery (ITA) to left anterior descending (LAD), 129 ITA and 65 saphenous vein grafts (SVG) to left circumflex (LCX), and 142 gastroepiploic artery (GEA) and 66 SVG to right coronary artery (RCA). Minimal luminal diameter, size of revascularized area, history of myocardial infarction, and PCI in the relevant area were examined to determine whether these factors are associated with flow insufficiency (FI), which was defined as ≤ 20 mL/min. RESULTS: FI developed in 123/736 grafts (16.7%) and correlated significantly with stenosis in the distal portion (23.0% vs. 12.8%, p = 0.0003). Prior myocardial infarction significantly correlated with FI in GEA-RCA (p = 0.002) and ITA-LCX grafts (p = 0.04). There was a history of PCI to the LAD (PCI group) in 54 ITA to LAD bypass grafts (16.2%), whereas the remaining 280 had no history of PCI to the LAD (no-PCI group). Graft flow was significantly greater in the no-PCI than in the PCI group (53 ± 29 vs. 42 ± 27; p = 0.006). The incidences of FI and graft failure were significantly higher in the PCI than the no-PCI group (22.2%, vs. 8.2%; p = 0.003; 9.2% vs. 1.8%; p = 0.003, respectively). CONCLUSIONS: Prior PCI has a negative impact on graft flow. The influences of small revascularized area, myocardial infarction, and PCI are greater, necessitating consideration of factors associated with flow demand or microvasculature when planning revascularization.


Assuntos
Reestenose Coronária/diagnóstico por imagem , Oclusão de Enxerto Vascular/diagnóstico por imagem , Grau de Desobstrução Vascular , Idoso , Angiografia Coronária , Ponte de Artéria Coronária , Reestenose Coronária/fisiopatologia , Reestenose Coronária/prevenção & controle , Feminino , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/prevenção & controle , Humanos , Cuidados Intraoperatórios , Masculino , Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea , Estudos Retrospectivos , Reologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA