Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
3.
Haemophilia ; 23(5): 689-696, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28470862

RESUMO

BACKGROUND: N8-GP (turoctocog alfa pegol) is an extended half-life glycoPEGylated recombinant factor VIII (FVIII) product developed for the prevention and treatment of bleeds in haemophilia A patients. AIM: This is a planned interim analysis of pathfinder™3, an international, open-label, Phase 3 trial evaluating the efficacy and safety (including immunogenicity) of N8-GP administered before, during and after major surgery in severe haemophilia A patients aged ≥12 years. METHODS: Sixteen patients who underwent 18 major surgical procedures (including synovectomy, joint replacement and ankle arthrodesis) were included here. Postoperative assessments were conducted daily for days 1-6, and once for days 7-14. Primary endpoint was N8-GP haemostatic efficacy, assessed after completion of surgery using a four-point scale ('excellent', 'good', 'moderate', 'none'). RESULTS: Haemostasis was successful (rated 'excellent' or 'good') on completion of surgery in 17 (94.4%) procedures and rated as 'moderate' (5.6%) for one surgery in a patient with multiple comorbidities who needed an intraoperative N8-GP dose (20.7 IU kg-1 ). In the postoperative period, three bleeds occurred (one during days 1-6; two during days 7-14); all were successfully treated with N8-GP. Mean N8-GP consumption on day of surgery was 80.0 IU kg-1 ; patients received a mean of 1.7 doses (median: 2, range: 1-3). No safety concerns were identified. CONCLUSION: The data showed that N8-GP was effective and well tolerated for the prevention and treatment of bleeds during major surgery; such FVIII products with extended half-lives may modify current treatment schedules, enabling fewer infusions and earlier patient discharge.


Assuntos
Fator VIII/uso terapêutico , Hemofilia A/complicações , Hemofilia A/tratamento farmacológico , Hemorragia/etiologia , Hemorragia/prevenção & controle , Procedimentos Cirúrgicos Operatórios/efeitos adversos , Adolescente , Adulto , Idoso , Fator VIII/administração & dosagem , Fator VIII/efeitos adversos , Fator VIII/farmacocinética , Meia-Vida , Hemofilia A/diagnóstico , Hemofilia A/cirurgia , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Polietilenoglicóis , Índice de Gravidade de Doença , Adulto Jovem
5.
Haemophilia ; 23(1): 59-66, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27480904

RESUMO

INTRODUCTION: MC710, a 1:10 protein weight ratio mixture of plasma-derived activated factor VII (FVIIa) and factor X (FX), is a novel bypassing agent for haemostasis in haemophilia patients with inhibitors. We evaluated the haemostatic efficacy and safety of one to two administrations of MC710 in 21 joint, muscle, and subcutaneous bleeding episodes in 14 male patients, in a multi-centre, open-label, non-randomized clinical trial. METHODS: Subjects were intravenously administered one or two doses of 60 or 120 µg kg-1 MC710 (as FVIIa) once or twice (to a maximum of 180 µg kg-1 ) over up to five bleeding episodes per subject. The haemostatic efficacy of MC710 was determined for each episode by investigator evaluation, using changes in visual analogue scale (VAS) for pain relief, and/or knee joint or muscle circumference for swelling reduction, and range of motion (ROM) for improvement of joint mobility. RESULTS: In 21 treatments for bleeding episodes, 19 were rated "excellent" or "effective" 8 h after the last treatment. VAS significantly decreased over time, and ROM significantly improved over time compared with the values before treatment. One mild adverse reaction, decreased blood potassium, and two serious adverse events, both knee joint bleeding, were observed within 1 week after first administration, with no significant effect on safety. Furthermore, diagnostic markers did not show any signs of disseminated intravascular coagulation (DIC). CONCLUSION: These results show that MC710 has sufficient haemostatic efficacy and safety, and can be used as a potential bypassing agent to control bleeding in haemophilia patients with inhibitors.


Assuntos
Fator VIIa/uso terapêutico , Fator X/uso terapêutico , Hemofilia A/tratamento farmacológico , Adolescente , Adulto , Humanos , Masculino , Adulto Jovem
6.
Haemophilia ; 23(2): e116-e123, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27943552

RESUMO

INTRODUCTION: Detecting signs of joint deterioration is important for early effective orthopaedic intervention in managing haemophilic arthropathy. AIM: We developed a simple, patient self-administered sheet to evaluate the joint condition, and assessed the predictive ability of this assessment sheet for the need for an orthopaedic intervention. METHODS: This was a single-centre, cross-sectional study. The association between the score of each of the four items of the assessment sheet (bleeding, swelling, pain and physical impairment) and the results of radiological findings and physical examinations based on Haemophilia Joint Health Score 2.1 was assessed. An optimal scoring system was explored by the area under the curve (AUC). The cut-off value for the need for surgery or physiotherapy was determined using the receiver operating characteristic curve procedure. RESULTS: Forty-two patients were included. The 'physical impairment' item showed the highest correlation coefficient with the results of radiographic and physical examinations (range: 0.57-0.76). The AUC of finally adjusted scoring indicates good ability to discriminate between patients with and without a need for orthopaedic intervention. The positive predictive value was the highest at a cut-off value of 4 points for knees (63.0%) and ankles (70.0%), at 5 points for elbows (66.7%) and the highest predictive accuracy at the cut-off value of 4 points for all the joints. The linear trend of the need for an orthopaedic intervention was observed with an increasing score. CONCLUSION: The joint condition assessment sheet can help clinicians assess the need for orthopaedic intervention for haemophilic arthropathy in Japanese patients with haemophilia.


Assuntos
Hemartrose/terapia , Hemofilia A/complicações , Adulto , Hemofilia A/terapia , Humanos , Procedimentos Ortopédicos , Exame Físico , Inquéritos e Questionários
10.
Haemophilia ; 21(5): 702-7, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25854709

RESUMO

INTRODUCTION: Dosage adjustment is very important to perform continuous infusion (CI) of recombinant factor IX (rFIX) concentrates more effectively and economically, and clearance (CL) is strongly related to the infusion rate. However, previous reports have shown that the CL of rFIX concentrates varies widely (4.2-11.4 mL kg(-1) h(-1) ). AIM: The goal of this study was to gain a better understanding of the CL of the rFIX concentrate (BeneFIX(®) ) to precisely set the infusion rate of rFIX concentrates. METHODS: We estimated CLs by five different calculation approaches: from area under the blood concentration-time curve (AUC), from in vivo recovery (IVR) and half-life, from actual FIX activity value during CI, and from the simulation by one-compartment model in seven patients with haemophilia B. RESULTS: The mean CL calculated from AUC was 3.8 ± 0.4 mL kg(-1) h(-1) (range = 3.3-4.3 mL kg(-1) h(-1) ). CONCLUSION: The mean CL calculated from IVR and distribution half-life was 4.4 ± 0.4 mL kg(-1) h(-1) (range = 4.0-5.1 mL kg(-1) h(-1) ). The mean CL calculated from IVR and terminal half-life was 2.1 ± 0.5 mL kg(-1) h(-1) (range = 1.7-2.8 mL kg(-1) h(-1) ). The mean CL during CI was 4.9 ± 0.6 mL kg(-1) h(-1) (range = 4.2-5.6 mL kg(-1) h(-1) ). In addition, when we simulated the theoretical CL using a one-compartment model, the adjusted mean CL during CI was 4.8 ± 0.5 mL kg(-1) h(-1) (range = 4.0-5.4 mL kg(-1) h(-1) ). The CL obtained from distribution half-life was comparable to the CL during CI, while the CL calculated from terminal half-life did not reflect actual CL. Further, the rFIX concentrate was characterized by a one-compartment model under certain conditions.


Assuntos
Fator IX/farmacocinética , Proteínas Recombinantes/farmacocinética , Adulto , Idoso , Área Sob a Curva , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA