Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Ophthalmic Vis Res ; 17(3): 384-389, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36160100

RESUMO

Purpose: In this case-control study, we measured visual acuity, objective refraction, ocular biometric parameters, and strabismus in premature cases classified according to the following categories: argon laser-treated retinopathy of prematurity (ROP), untreated spontaneously regressed ROP, no ROP, and full-term controls. Methods: Cases with a history of prematurity at six years of age were categorized into the following groups: patients with a history of treated type 1 ROP using argon laser (group I), untreated spontaneously regressed ROP (group II), and no history of ROP (group III). Group IV included age-matched healthy full-term controls. Funduscopy was performed for all the cases and the control group. Results: In total, 24 eyes of 12 laser-treated ROP cases, 186 eyes of 93 spontaneously regressed ROP patients, 74 eyes of 37 premature cases with no history of ROP, and 286 eyes of 143 controls were included in the study. The mean spherical equivalent in the treated cases was not significantly different from that in the untreated cases and patients in group III. However, the average cylindrical power was significantly different among the groups (P < 0.004). Furthermore, anisometropia ( ≥ 1.5 diopters) was diagnosed with a higher rate in the treated cases (P = 0.03). The corneal curvature of the laser-treated eyes was significantly steeper and the axial length was significantly shorter than those in the other groups (P < 0.002 and P < 0.001, respectively, for multivariate analysis). Strabismus was found in three treated patients (25%). Additionally, there were three treated eyes (12.5%) diagnosed with macular dragging. Conclusion: Premature cases including those who had a history of argon laser-treated ROP and those with untreated spontaneously regressed ROP showed acceptable long-term visual and refractive outcomes along with a fairly low rate of ocular disorders.

2.
J Ophthalmic Vis Res ; 17(4): 609-610, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36742458

RESUMO

[This corrects the article on p. 384 in vol. 17 PMCPMC9493422.].

3.
Iran J Public Health ; 49(7): 1202-1210, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33083286

RESUMO

BACKGROUND: We aimed to use the scientometric approach to evaluate immunological studies on the subject of sulfur mustard over the past 20 years. METHODS: In this scientometric study, the Web of Science Core Collection was searched on the studies about sulfur mustard. The published papers related to the field of immunology were retrieved from these papers. HistCite software and VOSviewer were the applied software packages for bibliometric analysis, information visualization, and creating bibliometric networks. RESULTS: Over the past 20 years, 741 researchers from 22 countries have published 201 scientific papers in 95 journals. Iran and the United States with 93 and 68 published articles ranked at the top. The Journal of International Immunopharmacology, with 33 published papers, 439 Total Global Citation Score (TGCS), and 105 Total Local Citation Score (TLCS) was the most productive and most influential in this regard. The paper entitled "Biomonitoring of exposure to chemical warfare agents: A review" and another paper entitled "Sardasht-Iran Cohort Study of Chemical Warfare Victims: Design and Methods" were the most influential papers in this topic with 200 TGCS and 27 TLCS, respectively. The most productive and the most influential centers were "Immunoregulation Research Center of Shahed University" and "The Janbazan Medical and Engineering Research Center (JMERC)," respectively. CONCLUSION: The result of our report as the unique scientometric evaluation of the research on sulfur mustard and Immunology can be used as a roadmap for authors, researchers, and policymakers to define the best ways to allocate their financial and executive resources.

4.
Artigo em Inglês | MEDLINE | ID: mdl-30923718

RESUMO

The aim of this study was to describe patient demographics, microbiological profile, and antibiotic susceptibility of corneal ulcer at a tertiary referral center to improve and optimize diagnosis and treatment of this potentially blinding entity and to reduce antibiotic misuse. Detailed external and slit-lamp bio-microscopic examination of 123 consecutive patients with suspected corneal ulcer was performed at an ophthalmology clinic. Corneal scraping was carried out under slit-lamp bio-microscopy. The obtained material was inoculated on culture media and smeared on a slide for Gram's staining for morphological identification of bacteria and fungus. For samples that developed colony in culture media, antibiotic susceptibility testing was performed. In a significant percentage of patients (72%) neither bacterial agents nor fungi were the cause of corneal ulcer. Of the 34 culture-proven corneal ulcers, in 79% of the cases, bacteria were detected while in 21% of cases, fungi were found. Of the 27 bacterial corneal ulcers, the majority were (67%) caused by Gram-positive bacteria, of which 50% were Streptococcus pneumoniae, and in the Gram-negative bacterial corneal ulcers, most of the cases (44%) were caused by Pseudomonas aeruginosa. In the antibiotic susceptibility report, Streptococcus pneumoniae, Staphylococcus aureus, Pseudomonas aeruginosa, and Escherichia coli were resistant to Cotrimoxazole (TS), Streptococcus pneumoniae to Erythromycin (E), Staphylococcus aureus to Peniciline (PG), Pseudomonas aeruginosa to Ceftriaxone (CRO) and Nitrofurantoin (NI), and finally, Escherichia coli to Gentamicin (GM). In conclusion, in a significant number of the patients neither bacterial agents nor fungi were offending microorganisms and bacteria were the most common agent of microbiological corneal ulcer, found in 79% of culture-proven corneal ulcers, followed by fungus, found in 21% of culture-proven corneal ulcers.

5.
Int J Ophthalmol ; 11(8): 1330-1336, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30140637

RESUMO

AIM: To explore the relationship between different parameters of Ocular Response Analyzer (ORA) and Corvis ST (CST) in a sample of healthy Iranian school-aged children and the relationship between parameters of these 2 instruments against intraocular pressure (IOP), measured by the Goldmann applanation tonometer (GAT-IOP), age and gender, and find possible correlation between ORA and CST with GAT. METHODS: This cross-sectional study included 90 healthy children. A general interview and complete eye examination were performed. Following successful GAT-IOP measurement, ORA and CST were conducted. The CST parameters were A 1/2 length (A1L, A2L), A 1/2 velocity (A1V, A2V), highest concavity deformation amplitude (HCDA), radius of curvature (RoC), peak distance (PD), central corneal thickness (CCT) and IOP. The ORA parameters were corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated IOP (IOP-G) and corneal compensated IOP (IOP-CC). Extracted data was analyzed using the Statistical Package for Social Science software. RESULTS: Totally 39 males with age of 9.08±1.60 (6-12)y and 51 females with age of 8.96±1.55 (6-13)y were included. Many CST parameters were significantly correlated with CH, CRF, IOP-G and IOP-CC. Some CST parameters had a significant correlation with GAT-IOP, including IOP-CST in both eyes and HCDA, A2L, PD, and RoC in the left eye, but none with age, except A2L in the right eye. The CRF measurement showed a significant correlation with GAT-IOP in both eyes and CH in the right eye, yet, none with age. Among all CST and ORA parameters, CCT-CST in both eyes and A1L in right eye had a significant correlation with gender, although this was a negligible negative correlation. Comparison of mean IOP values by different devices showed a significantly highest IOP overestimation by CST and lowest by IOP-CC compared with GAT. Also, IOP-G versus IOP-CST significantly had the lowest IOP overestimation among others. Overall, either low positive correlation or negligible correlation was found between IOP measurements by 3 instruments. CONCLUSION: The study finds the highest IOP overestimation by CST and lowest by IOP-CC compared with GAT. Overall, either low positive correlation or negligible correlation is found between IOP measurements by the 3 instruments.

6.
Dermatol Res Pract ; 2014: 596564, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25580109

RESUMO

Background. The aim of this study was to investigate maspin and ezrin expression in different subtypes of periocular basal cell carcinoma (BCC). Methods. Tissue samples from 43 patients with periocular BCC. Our cases were comprised of 10 morpheaform, 25 nodular, and 8 adenoid type BCCs. Immunohistochemical staining for maspin and ezrin was performed by Envision detection system. Results. There was no difference between different subtypes of BCC in maspin expression regarding positivity, intensity, and pattern of expression. Ezrin was expressed in all subtypes of BCC but the intensity was significantly higher in morpheaform BCC compared to nodular and adenoid types (P < 0.001 and P = 0.012, resp.); ninety percent of morpheaform samples showed strong ezrin intensity, while this strong intensity was only present in 25% and 12% of adenoid and nodular subtypes, respectively. There was no correlation between age, sex, or tumor margin involvement and expression of neither maspin nor ezrin. There was no correlation between maspin and ezrin expression except in nodular type, in which an inverse correlation was found (P = 0.004). Conclusion. Ezrin is expressed intensely in morpheaform BCC of periocular region. Further studies are needed to show the significance of this finding in prognosis of morpheaform BCC.

7.
J Ophthalmic Vis Res ; 4(3): 160-3, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23198066

RESUMO

PURPOSE: To evaluate the association between fixation preference (FP) and amblyopia in strabismic patients. METHODS: This study includes 50 patients with horizontal, vertical or mixed strabismus of at least 10 prism diopters. Best-corrected monocular visual acuity (VA) was measured using Snellen E-chart and the presence of amblyopia was determined accordingly; FP was evaluated and graded from 0 to 3. RESULTS: Of 50 patients, including 27 female and 23 male subjects, 29 (58%) patients had FP but 18 (36%) subjects were truly amblyopic. Overall, the sensitivity and specificity of FP for detection of amblyopia was 88.9% and 59.4% respectively. The positive predictive value (PPV) and negative predictive value (NPV) were 55.2% and 90.5% respectively. Sensitivity, PPV and NPV were significantly higher in esotropic as compared to exotropic patients. Strong monocular FP was correlated with more than 3 lines of interocular difference (IOD) in visual acuity (P=0.001). CONCLUSION: Although FP is not an ideal method for diagnosis of strabismic amblyopia, it has high sensitivity, PPV and NPV in esotropic patients and in subjects with more than 3 lines of IOD in VA.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA