Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Nano Lett ; 18(6): 3623-3629, 2018 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-29718676

RESUMO

The virus bioresistor (VBR) is a chemiresistor that directly transfers information from virus particles to an electrical circuit. Specifically, the VBR enables the label-free detection of a target protein that is recognized and bound by filamentous M13 virus particles, each with dimensions of 6 nm ( w) × 1 µm ( l), entrained in an ultrathin (∼250 nm) composite virus-polymer resistor. Signal produced by the specific binding of virus to target molecules is monitored using the electrical impedance of the VBR: The VBR presents a complex impedance that is modeled by an equivalent circuit containing just three circuit elements: a solution resistance ( Rsoln), a channel resistance ( RVBR), and an interfacial capacitance ( CVBR). The value of RVBR, measured across 5 orders of magnitude in frequency, is increased by the specific recognition and binding of a target protein to the virus particles in the resistor, producing a signal Δ RVBR. The VBR concept is demonstrated using a model system in which human serum albumin (HSA, 66 kDa) is detected in a phosphate buffer solution. The VBR cleanly discriminates between a change in the electrical resistance of the buffer, measured by Rsoln, and selective binding of HSA to virus particles, measured by RVBR. The Δ RVBR induced by HSA binding is as high as 200 Ω, contributing to low sensor-to-sensor coefficients-of-variation (<15%) across the entire calibration curve for HSA from 7.5 nM to 900 nM. The response time for the VBR is 3-30 s.


Assuntos
Bacteriófago M13/química , Técnicas Biossensoriais/instrumentação , Albumina Sérica Humana/análise , Vírion/química , Técnicas Biossensoriais/métodos , Impedância Elétrica , Desenho de Equipamento , Humanos , Limite de Detecção
2.
J Anal Toxicol ; 39(9): 726-33, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26311850

RESUMO

The detection of 6-acetylmorphine (6-AM) in urine by immunoassay methods is challenging due to its short half-life and its similarity in structure to many commonly abused opiates that are often present at very high concentrations in urine. Current 6-AM homogeneous enzyme immunoassays use lyophilized reagents because of the instability of 6-AM in water or lack of the required specificity due to high cross-reactivity with morphine. A new 6-AM rFab-based homogeneous enzyme immunoassay (HEIA) has been developed with highly improved specificity. Using a cutoff concentration of 10 ng/mL, morphine or morphine glucuronides did not produce a positive signal up to 300,000 or 1,000,000 ng/mL, respectively. Assay imprecision (n = 80) was less than 1.5% using four replicates per day for 20 days over the range 0-20 ng/mL. Cross-reactivity with structurally related or non-related compounds was assessed at concentrations up to 1,000,000 ng/mL. Interferences from endogenous compounds at ±25% cutoff were also performed at the concentrations ranging from 100,000 to 500,000 ng/mL. The effect of varied pH values on assay performance at ±25% cutoff was investigated; no false-positive or false-negative results were observed between pH 4 and -11. Based on the analysis of 149 authentic urine samples, the accuracy of the 6-AM HEIA compared with LC-MS-MS was 100%. These results demonstrated that rFab can be suitable for traditional HEIA with desired detection sensitivity and stability.


Assuntos
Técnicas Imunoenzimáticas , Fragmentos de Imunoglobulinas/química , Derivados da Morfina/urina , Analgésicos Opioides/urina , Cromatografia Líquida , Meia-Vida , Humanos , Concentração de Íons de Hidrogênio , Limite de Detecção , Morfina/urina , Sensibilidade e Especificidade , Manejo de Espécimes , Detecção do Abuso de Substâncias , Espectrometria de Massas em Tandem
3.
Genome Res ; 20(8): 1133-42, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20508142

RESUMO

Isogenic settings are routine in model organisms, yet remain elusive for genetic experiments on human cells. We describe the use of designed zinc finger nucleases (ZFNs) for efficient transgenesis without drug selection into the PPP1R12C gene, a "safe harbor" locus known as AAVS1. ZFNs enable targeted transgenesis at a frequency of up to 15% following transient transfection of both transformed and primary human cells, including fibroblasts and hES cells. When added to this locus, transgenes such as expression cassettes for shRNAs, small-molecule-responsive cDNA expression cassettes, and reporter constructs, exhibit consistent expression and sustained function over 50 cell generations. By avoiding random integration and drug selection, this method allows bona fide isogenic settings for high-throughput functional genomics, proteomics, and regulatory DNA analysis in essentially any transformed human cell type and in primary cells.


Assuntos
Técnicas de Transferência de Genes , Genoma Humano , Genômica/métodos , Sequências Reguladoras de Ácido Nucleico/genética , Dedos de Zinco/genética , Sequência de Bases , Linhagem Celular , Endonucleases/genética , Loci Gênicos , Humanos , Dados de Sequência Molecular , Proteômica/métodos
4.
Chembiochem ; 9(17): 2846-52, 2008 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-18973165

RESUMO

An Achilles heel inherent to all molecular display formats, background binding between target and display system introduces false positives into screens and selections. For example, the negatively charged surfaces of phage, mRNA, and ribosome display systems bind with unacceptably high nonspecificity to positively charged target molecules, which represent an estimated 35% of proteins in the human proteome. Here we report the first systematic attempt to understand why a broad class of molecular display selections fail, and then solve the underlying problem for both phage and RNA display. Firstly, a genetic strategy was used to introduce a short, charge-neutralizing peptide into the solvent-exposed, negatively charged phage coat. The modified phage (KO7(+)) reduced or eliminated nonspecific binding to the problematic high-pI proteins. In the second, chemical approach, nonspecific interactions were blocked by oligolysine wrappers in the cases of phage and total RNA. For phage display applications, the peptides Lys(n) (where n=16 to 24) emerged as optimal for wrapping the phage. Lys(8), however, provided effective wrappers for RNA binding in assays against the RNA binding protein HIV-1 Vif. The oligolysine peptides blocked nonspecific binding to allow successful selections, screens, and assays with five previously unworkable protein targets.


Assuntos
Bacteriófagos , Biblioteca de Peptídeos , RNA Mensageiro , Proteínas de Ligação a RNA , Sequência de Aminoácidos , Bacteriófago M13/química , Bacteriófago M13/genética , Bacteriófagos/química , Bacteriófagos/genética , Desoxirribonucleases/química , Desoxirribonucleases/genética , Ensaio de Imunoadsorção Enzimática , Ligantes , Lisina/química , Dados de Sequência Molecular , Mutagênese , Ligação Proteica , RNA Mensageiro/química , RNA Mensageiro/genética , Proteínas de Ligação a RNA/química , Proteínas de Ligação a RNA/genética , Produtos do Gene vif do Vírus da Imunodeficiência Humana/química , Produtos do Gene vif do Vírus da Imunodeficiência Humana/genética
5.
Anal Chem ; 78(10): 3265-70, 2006 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-16689525

RESUMO

A dense virus layer, readily tailored for recognition of essentially any biomarker, was covalently attached to a gold electrode surface through a self-assembled monolayer. The resistance of this "virus electrode", Z(Re), measured in the frequency range from 2 to 500 kHz in a salt-based pH 7.2 buffer, increased when the phage particles selectively bound either an antibody or prostate-specific membrane antigen (PSMA), a biomarker for prostate cancer. In contrast to prior results, we show the capacitive impedence of the virus electrode, Z(Im), is both a noisier and a less sensitive indicator of this binding compared to Z(Re). The specificity of antibody and PSMA binding, and the absence of nonspecific binding to the virus electrode, was confirmed using quartz crystal microbalance gravimetry.


Assuntos
Bacteriófago M13/química , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Bacteriófago M13/ultraestrutura , Eletroquímica , Eletrodos , Ouro/química , Microscopia de Força Atômica
6.
Nucleic Acids Res ; 32(21): 6407-13, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15585664

RESUMO

Protein engineering uses oligonucleotide-directed mutagenesis to modify DNA sequences through a two-step process of hybridization and enzymatic synthesis. Inefficient reactions confound attempts to introduce mutations, especially for the construction of vast combinatorial protein libraries. This paper applied computational approaches to the problem of inefficient mutagenesis. Several results implicated oligonucleotide annealing to non-target sites, termed 'cross-hybridization', as a significant contributor to mutagenesis reaction failures. Test oligonucleotides demonstrated control over reaction outcomes. A novel cross-hybridization score, quickly computable for any plasmid and oligonucleotide mixture, directly correlated with yields of deleterious mutagenesis side products. Cross-hybridization was confirmed conclusively by partial incorporation of an oligonucleotide at a predicted cross-hybridization site, and by modification of putative template secondary structure to control cross-hybridization. Even in low concentrations, cross-hybridizing species in mixtures poisoned reactions. These results provide a basis for improved mutagenesis efficiencies and increased diversities of cognate protein libraries.


Assuntos
Mutagênese Sítio-Dirigida , Oligonucleotídeos/química , Algoritmos , Sequência de Bases , Biologia Computacional , Dados de Sequência Molecular , Hibridização de Ácido Nucleico
7.
Chem Biol ; 10(2): 161-8, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12618188

RESUMO

The highly abundant GTP binding protein elongation factor Tu (EF-Tu) fulfills multiple roles in bacterial protein biosynthesis. Phage-displayed peptides with high affinity for EF-Tu were selected from a library of approximately 4.7 x 10(11) different peptides. The lack of sequence homology among the identified EF-Tu ligands demonstrates promiscuous peptide binding by EF-Tu. Homolog shotgun scanning of an EF-Tu ligand was used to dissect peptide molecular recognition by EF-Tu. All homolog shotgun scanning selectants bound to EF-Tu with higher affinity than the starting ligand. Thus, homolog shotgun scanning can simultaneously optimize binding affinity and rapidly provide detailed structure activity relationships for multiple side chains of a polypeptide ligand. The reported peptide ligands do not compete for binding to EF-Tu with various antibiotic EF-Tu inhibitors, and could identify an EF-Tu peptide binding site distinct from the antibiotic inhibitory sites.


Assuntos
Fator Tu de Elongação de Peptídeos/antagonistas & inibidores , Biblioteca de Peptídeos , Peptídeos/metabolismo , Peptídeos/farmacologia , Sequência de Aminoácidos , Sítios de Ligação , Clonagem Molecular , Ensaio de Imunoadsorção Enzimática , Escherichia coli/metabolismo , Guanosina Difosfato/metabolismo , Dados de Sequência Molecular , Oligonucleotídeos/química , Fator Tu de Elongação de Peptídeos/metabolismo , Peptídeos/síntese química , Conformação Proteica , Reação em Cadeia da Polimerase Via Transcriptase Reversa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA