Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 339
Filtrar
1.
J Vasc Surg Cases Innov Tech ; 10(4): 101536, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38966819

RESUMO

We present a rare anatomical configuration of a 19-year-old woman, characterized by descending thoracic aortic aneurysm with right aberrant subclavian arteries with a Kommerell's diverticulum in a left aortic arch. The complexity of this vascular anomaly was accompanied by an anomalous origin of left subclavian artery. The patient underwent a single-stage open surgical repair via left thoracotomy under deep hypothermic circulatory arrest. The bilateral aberrant subclavian arteries were separately reconstructed in situ using hand-sewn branched grafts.

2.
JTCVS Open ; 19: 31-38, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39015446

RESUMO

Objective: Aortoesophageal fistula is a rare, life-threatening condition. There is no consensus regarding the surgical management of the esophagus in this condition. Methods: We retrospectively evaluated 13 patients diagnosed with aortoesophageal fistulas at a single institution from 2003 to 2021. Descriptive statistics were used to analyze patient characteristics, operative characteristics, and patient outcomes. Kaplan-Meier survival analysis was performed. Results: Patients' mean age was 63.5 years, and 6 (46.2%) were female. The most common presenting symptoms were hemoptysis/hematemesis (69.2%), chest/back pain (46.2%), and fever (38.5%). Twelve patients (92.3%) had a history of aortic procedures. The median time between the index operation and repair of the secondary aortoesophageal fistula in the 12 patients was 5 months. The index operation was a thoracic endovascular aortic repair in 10 of 12 patients (83.3%). Eleven patients (84.6%) underwent primary esophageal repair with flap coverage (omentum or muscle). One of these patients needed an esophagectomy within 1 year. The primary surgical management of the aorta was graft excision and replacement, aside from 1 patient who underwent primary repair. The 30-day survival was 69.2%, and 1-year and 5-year survivals were 31.7%. There were no recurrent infections at the esophageal fistula site. Conclusions: Aortoesophageal fistula remains a rare condition, but its case numbers have increased with thoracic endovascular aortic repair. It continues to be a difficult condition to manage and has a high fatality rate. Esophageal-preserving surgery may be a safe and less-invasive option for patients with a small defect.

3.
J Pharm Sci ; 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38734208

RESUMO

The olfactory and trigeminal pathways are direct delivery pathways between the nose and brain. To determine the effect of direct delivery on drug distribution in the brain, two model drugs with different physical properties, antipyrine (ANP), with high membrane permeability, and ranitidine (RNT), with low membrane permeability, were selected. For ANP, direct delivery from the nose to the brain was observed only in the olfactory bulb beside the nasal cavity, with a direct transport percentage (DTP) of approximately 45 %, whereas in the frontal and occipital brains, the contribution from the systemic circulation to the brain was observed as the primary route of brain distribution. No significant variations were observed in the pharmacokinetics of ANP in the left and right brain, whereas RNT was distributed in all brain regions with a DTP of > 95 %. The closer the brain region is to the nasal cavity, the higher the DTP. Furthermore, the left brain, the same nostril site (left nostril) of administration, had a larger level of drug delivery than the right brain. These findings imply that the influence of the administered nostril site differs based on the physicochemical properties and amount of the drug.

4.
Gen Thorac Cardiovasc Surg ; 72(5): 293-304, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38480670

RESUMO

Heritable thoracic aortic disease puts patients at risk for aortic aneurysms, rupture, and dissections. The diagnosis and management of this heterogenous patient population continues to evolve. Last year, the American Heart Association/American College of Cardiology Joint Committee published diagnosis and management guidelines for aortic disease, which included those with genetic aortopathies. Additionally, evolving research studying the implications of underlying genetic aberrations with new genetic testing continues to become available. In this review, we evaluate the current literature surrounding the diagnosis and management of heritable thoracic aortic disease, as well as novel therapeutic approaches and future directions of research.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma Aórtico , Doenças da Aorta , Estados Unidos , Humanos , Aorta Torácica/cirurgia , Doenças da Aorta/genética , Doenças da Aorta/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/genética , Aneurisma da Aorta Torácica/cirurgia
5.
JACC Cardiovasc Interv ; 17(5): 608-618, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38479962

RESUMO

BACKGROUND: Whether intraluminal drug-coated balloon (DCB) angioplasty is superior to subintimal DCB angioplasty regarding femoropopliteal (FP) chronic total occlusion (CTO) outcomes has not been systematically determined. OBJECTIVES: The aim of this study was to compare the 1-year clinical outcomes of intraluminal and subintimal DCB angioplasty for the treatment of patients with symptomatic FP CTO. METHODS: This subanalysis of POPCORN (Prospective Multi-Center Registry of Drug-Coated Balloon for Femoropopliteal Disease) evaluated 469 lesions in 469 symptomatic patients with lower extremity artery disease who presented with FP CTO and underwent DCB treatment. Wire passage (intraluminal vs subintimal) was evaluated using intravascular ultrasound. The outcome measure, 1-year freedom from restenosis, was compared between subintimal and intraluminal DCB angioplasty groups after propensity score matching analysis. The Institutional Review Boards of participating centers approved this study. Informed consent was obtained from the participants or their families. RESULTS: During the median follow-up period of 14.2 months, restenosis occurred in 140 patients. After propensity score matching, the subintimal group had a significantly lower 1-year rate of freedom from restenosis than the intraluminal group (77.0% vs 84.2%, respectively; P = 0.024). Interaction analysis revealed a more marked increased risk for restenosis in the subintimal DCB angioplasty group in patients with severe calcification, low-dose DCB use, or smoking. CONCLUSIONS: The present study revealed that intraluminal DCB angioplasty was superior to subintimal DCB angioplasty for FP CTO treatment, with a significantly better 1-year rate of freedom from restenosis.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Humanos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Doença Arterial Periférica/etiologia , Angioplastia com Balão/efeitos adversos , Materiais Revestidos Biocompatíveis , Grau de Desobstrução Vascular
6.
Biomol NMR Assign ; 18(1): 71-78, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38551798

RESUMO

The intraflagellar transport (IFT) machinery plays a crucial role in the bidirectional trafficking of components necessary for ciliary signaling, such as the Hedgehog, Wnt/PCR, and cAMP/PKA systems. Defects in some components of the IFT machinery cause dysfunction, leading to a wide range of human diseases and developmental disorders termed ciliopathies, such as nephronophthisis. The IFT machinery comprises three sub-complexes: BBsome, IFT-A, and IFT-B. The IFT protein 54 (IFT54) is an important component of the IFT-B sub-complex. In anterograde movement, IFT54 binds to active kinesin-II, walking along the cilia microtubule axoneme and carrying the dynein-2 complex in an inactive state, which works for retrograde movement. Several mutations in IFT54 are known to cause Senior-Loken syndrome, a ciliopathy. IFT54 possesses a divergent Calponin Homology (CH) domain termed as NN-CH domain at its N-terminus. However, several aspects of the function of the NN-CH domain of IFT54 are still obscure. Here, we report the 1H, 15N, and 13C resonance assignments of the NN-CH domain of human IFT54 and its solution structure. The NN-CH domain of human IFT54 adopts essentially the α1-α2-α3-α4-α5 topology as that of mouse IFT54, whose structure was determined by X-ray crystallographic study. The structural information and assignments obtained in this study shed light on the molecular function of the NN-CH domain in IFT54.


Assuntos
Proteínas dos Microfilamentos , Domínios Proteicos , Humanos , Proteínas de Ligação ao Cálcio/química , Proteínas de Ligação ao Cálcio/metabolismo , Calponinas , Proteínas dos Microfilamentos/química , Isótopos de Nitrogênio , Ressonância Magnética Nuclear Biomolecular , Soluções
7.
J Endovasc Ther ; : 15266028241231472, 2024 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-38369732

RESUMO

PURPOSE: Surgical thromboendarterectomy has been the gold standard treatment for common femoral artery (CFA) disease. However, endovascular therapy (EVT) is conducted in certain patients with CFA lesions because of multiple comorbidities. The interwoven nitinol stent (IWS) has been developed to prevent stent fracture. Thus, this study aimed to evaluate the feasibility of EVT using IWS for CFA lesions in clinical practice. MATERIALS AND METHODS: This retrospective multicenter registry analyzed patients who had symptomatic lower-extremity artery disease due to CFA lesions and underwent EVT using IWS between 2019 and 2021. The primary endpoint was restenosis 2 years after EVT. RESULTS: This study enrolled a total of 177 patients with 196 CFA lesions. The 2-year estimate of freedom from restenosis was 88.0%. The 2-year freedom rates from the target-lesion revascularization, major amputation, and all-cause death were 92.9%, 99.0%, and 75.2%, respectively. The clinical features significantly associated with restenosis risk were the reference vessel diameter (RVD, per 1.0 mm, hazard ratio [HR], 0.24 [0.08-0.70]; p=0.009), external iliac artery (EIA) involvement (HR=4.03 [1.56-10.4]; p=0.004), superficial femoral artery (SFA) involvement (HR=3.05 [1.00-9.25]; p=0.049), body mass index (BMI; per 1.0, HR=0.85 [0.73-0.99]; p=0.032), occlusion of deep femoral arteries (DFAs) at baseline (HR=7.89 [2.04-30.5]; p=0.003), and chronic limb-threatening ischemia (CLTI, HR=2.63 [1.02-6.78]; p=0.045). Their significant association was also confirmed by the random survival forest analysis. During a median follow-up of 12.0 months, guiding sheaths were inserted via CFAs implanted IWSs in 73 cases (37.2%), and no patients had cannulation-related complications, such as failed hemostasis, fracture of IWS, and stent occlusion. CONCLUSIONS: Endovascular therapy using IWS in CFA lesions showed acceptable 2-year patency rates at 88.0% and might preserve the arterial access via the ipsilateral CFAs. Small RVD, involving EIA and SFA lesions, emaciation, occluded DFA, and CLTI are associated with poor 2-year patency rates following EVT, thus, IWS implantation in CFA lesions may be an option for patients unsuitable for surgical revascularization. CLINICAL IMPACT: This retrospective multicenter registry enrolled 177 patients with 199 CFA lesions treated with EVT using interwoven nitinol stents, because surgical thromboendarterectomy was difficult due to their multiple comorbidities. The 2-year estimate of freedom from restenosis was acceptable at 88.0%. The 2-year freedom rate from major amputation was also high at 99.0%. Moreover, during a median follow-up of 12.0 months, guiding sheaths were inserted via CFAs implanted IWSs in 73 cases, and no patients had cannulation-related complications such as failed hemostasis, fracture of IWS, and stent occlusion.

8.
J Control Release ; 367: 515-521, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38237689

RESUMO

This study explored the effectiveness of nasal administration in delivering magnetic nanoparticles into the brain for magnetic particle imaging of target regions. Successful delivery of iron oxide nanoparticles, which serve as contrast agents, to specific sites within the brain is crucial for achieving magnetic particle imaging. Nasal administration has gained attention as a method to bypass the blood-brain barrier and directly deliver therapeutics to the brain. In this study, we investigated surface modification techniques for administering magnetic nanoparticles into the nasal cavity, and provided experimental validation through in vivo studies. By compositing magnetic nanoparticles with gold nanoparticles, we enabled additional surface modification via AuS bonds without compromising their magnetic properties. The migration of the designed PEGylated magnetic nanoparticles into the brain following nasal administration was confirmed by magnetization measurements. Furthermore, we demonstrated the accumulation of these nanoparticles at specific target sites using probe molecules immobilized on the PEG terminus. Thus, the efficacy of delivering magnetic nanoparticles to the brain via nasal administration was demonstrated in this study. The findings of this research are expected to contribute significantly to the realization of magnetic particle imaging of target regions within the brain.


Assuntos
Nanopartículas de Magnetita , Nanopartículas , Administração Intranasal , Nanopartículas de Magnetita/química , Ouro , Encéfalo/diagnóstico por imagem , Nanopartículas/química , Fenômenos Magnéticos , Tamanho da Partícula , Sistemas de Liberação de Medicamentos
9.
AAPS PharmSciTech ; 25(1): 26, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38273054

RESUMO

The color of the tablets and capsules produced by pharmaceutical companies is important from the perspectives of product branding and counterfeiting. According to some studies, light can change tablet color during storage. In this study, tablets comprising amlodipine besylate (AB), a well-known light-sensitive drug, were coated with commonly used coating materials and exposed to light. Compared to the tablets that were not exposed to light, the color of those exposed to light changed over time. In fact, a faster and more pronounced color change was observed in the tablets exposed to light; however, the amount of AB did not decrease significantly in these tablets. The coating materials and their amounts were varied to clarify the materials involved in the color change. Based on the results, titanium dioxide and hypromellose may be involved in the color change process. As titanium dioxide is a photocatalyst, it may induce or promote chemical changes in hypromellose upon light irradiation. Overall, care should be exercised during selection of the coating polymer because titanium dioxide may promote photodegradation of the coatings while protecting the tablet's active ingredient from light.


Assuntos
Polímeros , Titânio , Derivados da Hipromelose , Fotólise , Comprimidos
12.
J Vasc Surg Cases Innov Tech ; 9(3): 101216, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37408950

RESUMO

A 30-year-old woman presented following a motor vehicle collision with a grade III blunt thoracic aortic injury and an aberrant right subclavian artery. Using intraoperative ultrasound and diagnostic subtraction angiography, we deployed an aortic endograft (cTAG; W.L. Gore & Associates), excluding the injury and aberrant right subclavian artery. The patient immediately lost arterial waveforms in her left arm, confirming incidental coverage of the left subclavian artery, likely due to the polytetrafluoroethylene sheath of the endograft. Her pulses returned after placement of a left subclavian chimney via retrograde brachial artery access.

13.
Heart Vessels ; 38(9): 1117-1129, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37217811

RESUMO

Isolated atherosclerotic popliteal lesions (IAPLs) have been considered challenging. This study aimed to investigate the efficacy of endovascular therapy (EVT) using the newer devices for IAPLs. This retrospective multicenter registry analyzed patients with lower extremity artery disease having IAPLs who underwent EVT using the newer devices between 2018 and 2021. The primary outcome was primary patency 1 year after EVT. A total of 392 consecutive patients undergoing EVT for IAPLs were enrolled. The Kaplan-Meier analysis showed that the primary patency and the freedom from target lesion revascularization were 80.9% and 87.8% 1 year after EVT, respectively. The multivariate Cox proportional hazards regression analysis showed that the clinical features that were independently associated with restenosis risk were drug-coated balloon (DCB) use for younger age (< 75 years old; adjusted hazard ratio, 3.08 [95% confidence interval 1.08-8.74]; P = 0.035), non-ambulatory status (2.74 [95% confidence interval 1.56-4.81]; P < 0.001), cilostazol use (0.51 [95% confidence interval 0.29-0.88]; P = 0.015), severe calcification (1.86 [95% confidence interval 1.18-2.94]; P = 0.007), and small external elastic membrane (EEM) area measured by intravascular ultrasound (IVUS) (< 30 mm2) (2.07 [95% confidence interval 1.19-3.60]; P = 0.010). From the univariate analysis, among patients treated with DCB, younger patients (n = 141) were associated with more comorbidities including smoking (P < 0.001), diabetes mellitus (P < 0.001), end-stage renal disease (P < 0.001), history of revascularization (P = 0.046) and small EEM area (P = 0.036), compared to older patients (n = 140). Moreover, smaller post-procedural minimum lumen area measured by IVUS after DCB dilatation was observed in younger patients (12 ± 4 vs. 14 ± 4 mm2, P = 0.033). This retrospective study demonstrated that the current EVT provided an acceptable 1-year primary patency rate in patients with IAPLs. The primary patency was lower following DCB in younger patients, likely due to the higher rates of comorbidities in this patient population.


Assuntos
Angioplastia com Balão , Aterosclerose , Procedimentos Endovasculares , Doença Arterial Periférica , Humanos , Idoso , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/cirurgia , Estudos Retrospectivos , Artéria Femoral , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/terapia , Doença Arterial Periférica/etiologia , Angioplastia com Balão/efeitos adversos , Resultado do Tratamento , Aterosclerose/cirurgia , Aterosclerose/etiologia , Procedimentos Endovasculares/efeitos adversos , Sistema de Registros , Grau de Desobstrução Vascular , Materiais Revestidos Biocompatíveis
14.
Ann Vasc Dis ; 16(1): 38-45, 2023 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37006868

RESUMO

Background: Drug-coated balloons (DCBs) and drug-eluting stents (DES) were available for treating femoropopliteal disease since 2017 and 2019. However, there are few reports to investigate whether approval of DCB and DES improved primary patency in clinical practice. Materials and Methods: We divided consecutive 407 patients into 2017 (n=93), 2018 (n=128), and 2019 (n=186) groups, undergoing endovascular therapy (EVT) for de novo femoropopliteal lesions in our hospital. We retrospectively compared clinical characteristics, procedure, and one-year patency between the three groups. Results: Baseline characteristics were not different except for the lower rate of popliteal lesions in 2017 (p=0.030). Use of DCB increased from 7.5% in 2017 to 38.7% in 2019, and use of DES from 0.0% in 2018 to 24.2% in 2019. One-year primary patency increased significantly both from 2017 to 2018 (62.7% vs. 70.8%, p=0.036) and from 2018 to 2019 (70.8% vs. 80.5%, p=0.025). Cox proportional multivariate analysis revealed that restenosis was independently associated with advanced age (p=0.036) and hemodialysis (p=0.003). Conversely, use of paclitaxel-based devices (p<0.001) and larger diameter of finalized devices (p=0.005) were protective factors against restenosis. Conclusion: One-year primary patency after EVT in femoropopliteal lesions was improved annually by utilizing DCB and DES, individually.

15.
Methodist Debakey Cardiovasc J ; 19(2): 49-58, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36910546

RESUMO

Thoracoabdominal aortic aneurysms (TAAA) represent a unique pathology that is associated with considerable mortality if untreated. While the advent of endovascular technologies has introduced new modalities for consideration, the mainstay of TAAA treatment remains open surgical repair. However, the optimal conduct of open TAAA repair requires careful consideration of patient risk factors and a collaborative team effort to mitigate the risk of perioperative complications. In this chapter, we briefly outline the history of treating TAAA, preoperative preparation and postoperative care, and our operative techniques for treatment.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/cirurgia , Estudos Retrospectivos , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia
16.
J Vasc Surg ; 78(1): 142-149, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36822257

RESUMO

OBJECTIVE: Dual antiplatelet therapy (DAPT) continues to be the preferred medication regimen after the placement of a carotid stent using the transcarotid revascularization (TCAR) technique despite a dearth of quality data. Therefore, this investigation was performed to define the risks associated with antiplatelet choice. METHODS: We queried all patients who underwent TCAR captured by the Vascular Quality Initiative from September 2016 to June 2022, to determine the association between antiplatelet choice and outcomes. Patients maintained on DAPT were compared with those receiving alternative regimens consisting of single antiplatelet, anticoagulation, or a combination of the two. A 1:1 propensity-score match was performed with respect to baseline comorbidities, functional status, anatomic/physiologic risk, medications, and intraoperative characteristics. In-hospital and 1-year outcomes were compared between the groups. RESULTS: During the study period, 29,802 procedures were included in our study population, with 24,651 (82.7%) receiving DAPT and 5151 (17.3%) receiving an alternative antiplatelet regimen. A propensity-score match with respect to 29 variables generated 4876 unique pairs. Compared with patients on DAPT, in-hospital ipsilateral stroke was significantly higher in patients receiving alternative antiplatelet regimens (1.7% vs 1.1%, odds ratio [95% confidence interval]: 1.54 [1.10-2.16], P = .01), whereas no statistically significant difference was noted with respect to mortality (0.6% vs 0.5%, 1.35 [0.72-2.54], P = .35). A composite of stroke/death was also more likely in patients receiving an alternative regimen (2.4% vs 1.7%, 1.47 [1.12-1.93], P = .01). Immediate stent thrombosis (2.75 [1.16-6.51]) and a nonsignificant trend toward increased return to the operating room were more common in the alternative patients. Conversely, the incidence of perioperative myocardial infarction was lower in the alternative regimen group (0.4% vs 0.7%, 0.53 [0.31-0.90], P = .02). At 1 year after the procedure, we observed an increased risk of mortality (hazard ratio [95% confidence interval]: 1.34 [1.11-1.63], P < .01) but not stroke (0.52 [0.27-0.99], P = .06) in patients treated with an alternative medication regimen. CONCLUSIONS: This propensity-score-matched analysis demonstrates an increased risk of in-hospital stroke and 1-year mortality after TCAR in patients treated with an alternative medication regimen instead of DAPT. Further studies are needed to elucidate the drivers of DAPT failure in patients undergoing TCAR to improve outcomes for carotid stenting patients.


Assuntos
Estenose das Carótidas , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Inibidores da Agregação Plaquetária/efeitos adversos , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/terapia , Estenose das Carótidas/complicações , Fatores de Risco , Resultado do Tratamento , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/epidemiologia , Stents/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Medição de Risco
18.
J Thorac Cardiovasc Surg ; 165(3): 944-953, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34517983

RESUMO

OBJECTIVE: Intraoperative motor and somatosensory evoked potentials have been applied to monitor spinal cord ischemia during repair. However, their predictive values remain controversial. The purpose of this study was to evaluate the impact of motor evoked potentials and somatosensory evoked potentials on spinal cord ischemia during open distal aortic repair. METHODS: Our group began routine use of both somatosensory evoked potentials and motor evoked potentials at the end of 2004. This study used a historical cohort design, using risk factor and outcome data from our department's prospective registry. Univariate and multivariable statistics for risk-adjusted effects of motor evoked potentials and somatosensory evoked potentials on neurologic outcome and model discrimination were assessed with receiver operating characteristic curves. RESULTS: Both somatosensory evoked potentials and motor evoked potentials were measured in 822 patients undergoing open distal aortic repair between December 2004 and December 2019. Both motor evoked potentials and somatosensory evoked potentials were intact for the duration of surgery in 348 patients (42%). Isolated motor evoked potential loss was observed in 283 patients (34%), isolated somatosensory evoked potential loss was observed in 18 patients (3%), and both motor evoked potential and somatosensory evoked potential loss were observed in 173 patients (21%). No spinal cord ischemia occurred in the 18 cases with isolated somatosensory evoked potential loss. When both signals were lost, signal loss happened in the order of motor evoked potentials and then somatosensory evoked potentials. Immediate spinal cord ischemia occurred in none of those without signal loss, 4 of 283 (1%) with isolated motor evoked potential loss, and 15 of 173 (9%) with motor evoked potential plus somatosensory evoked potential loss. Delayed spinal cord ischemia occurred in 12 of 348 patients (3%) with intact evoked potentials, 24 of 283 patients (8%) with isolated motor evoked potentials loss, and 27 of 173 patients (15%) with motor evoked potentials + somatosensory evoked potentials loss (P < .001). Motor evoked potentials and somatosensory evoked potentials loss were each independently associated with spinal cord ischemia. For immediate spinal cord ischemia, no return of motor evoked potential signals at the conclusion of the surgery had the highest odds ratio of 15.87, with a receiver operating characteristic area under the curve of 0.936, whereas motor evoked potential loss had the highest odds ratio of 3.72 with an area under the curve of 0.638 for delayed spinal cord ischemia. CONCLUSIONS: Somatosensory evoked potentials and motor evoked potentials are both important monitoring measures to predict and prevent spinal cord ischemia during and after open distal aortic repairs. Intraoperative motor evoked potential loss is a risk for immediate and delayed spinal cord ischemia after open distal aortic repair, and somatosensory evoked potential loss further adds predictive value to the motor evoked potential.


Assuntos
Aneurisma da Aorta Torácica , Isquemia do Cordão Espinal , Humanos , Medula Espinal , Potenciais Somatossensoriais Evocados/fisiologia , Potencial Evocado Motor , Isquemia do Cordão Espinal/diagnóstico , Isquemia do Cordão Espinal/etiologia , Isquemia do Cordão Espinal/prevenção & controle , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia
19.
Ann Thorac Surg ; 115(2): e49-e51, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35305993

RESUMO

Thoracoabdominal aortic aneurysms in toddlers are extremely rare. However, we experienced an extent III thoracoabdominal aortic aneurysm in a boy with tuberous sclerosis who underwent 3 open repairs and 1 endovascular aortic repair between the ages of 4 years and 18 years. This case highlights the potential for severe recurrent vascular aneurysms in the thoracic and abdominal aorta as a complication of tuberous sclerosis in children. Although aortic aneurysms in children are rare, it is vital to recognize these cases to prevent death due to rupture.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Esclerose Tuberosa , Masculino , Humanos , Pré-Escolar , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico , Esclerose Tuberosa/complicações , Esclerose Tuberosa/cirurgia , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Resultado do Tratamento , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos
20.
Semin Thorac Cardiovasc Surg ; 35(3): 465, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35779847
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA