Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 283
Filtrar
1.
Ophthalmol Ther ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38874887

RESUMO

INTRODUCTION: The aim of this study was to evaluate the refractive error in patients undergoing combined phacovitrectomy with and without gas tamponade. METHODS: This was a retrospective chart review including patients undergoing phacoemulsification alone (Group 1), combined phacovitrectomy for epiretinal membrane (Group 2), and combined phacovitrectomy with gas tamponade for rhegmatogenous retinal detachment (RRD) (Group 3). Axial length and keratometry were measured using an optical biometric system (Argos, Alcon Laboratories. Inc.), and a three-piece intraocular lens (IOL; NX-70S) was implanted in all groups. In each group, the prediction error at 3 months was calculated using IOL power calculation formulas (SRK/T, Hill-RBF, Kane, and Barrett Universal II) for each eye. Outcome measures included the mean prediction error (MPE), its standard deviation (SD), and the mean absolute error (MAE). The change in IOL position at 3 months was also assessed using anterior segment optical coherence tomography. RESULTS: A total of 104 eyes were included (Group 1: 30; Group 2: 34; Group 3: 40 eyes). The MPE was -0.08 ± 0.37 diopters (D), -0.26 ± 0.32 D, and -0.59 ± 0.34 D in Group 1, Group 2, and Group 3, respectively, using the Barrett Universal II formula (P < 0.01, ANOVA). The movement forward in the IOL position was 0.95 ± 0.16 mm, 0.94 ± 0.12 mm, and 1.07 ± 0.20 mm in Group 1, Group 2, and Group 3, respectively (P < 0.01). No significant difference was shown in MPE among the four formulas after combined phacovitrectomy with gas (P = 0.531). CONCLUSIONS: Phacovitrectomy in RRD induced a significant myopic shift using any of the clinically available formulas. This suggests that myopic shift should be taken into consideration for better refractive outcomes in phacovitrectomy with gas tamponade in RRD.

2.
Nat Commun ; 15(1): 4600, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38816382

RESUMO

Electron transfer is a fundamental energy conversion process widely present in synthetic, industrial, and natural systems. Understanding the electron transfer process is important to exploit the uniqueness of the low-dimensional van der Waals (vdW) heterostructures because interlayer electron transfer produces the function of this class of material. Here, we show the occurrence of an electron transfer process in one-dimensional layer-stacking of carbon nanotubes (CNTs) and boron nitride nanotubes (BNNTs). This observation makes use of femtosecond broadband optical spectroscopy, ultrafast time-resolved electron diffraction, and first-principles theoretical calculations. These results reveal that near-ultraviolet photoexcitation induces an electron transfer from the conduction bands of CNT to BNNT layers via electronic decay channels. This physical process subsequently generates radial phonons in the one-dimensional vdW heterostructure material. The gathered insights unveil the fundamentals physics of interfacial interactions in low dimensional vdW heterostructures and their photoinduced dynamics, pushing their limits for photoactive multifunctional applications.

3.
Small Methods ; : e2301387, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38470210

RESUMO

The application of carbon nanotube (CNT) yarns as thermoelectric materials for harvesting energy from low-grade waste heat including that generated by the human body, is attracting considerable attention. However, the lack of efficient n-type CNT yarns hinders their practical implementation in thermoelectric devices. This study reports efficient n-doping of CNT yarns, employing 4-(1, 3-dimethyl-2, 3-dihydro-1H-benzimidazole-2-yl) phenyl) dimethylamine (N-DMBI) in alternative to conventional n-dopants, with o-dichlorobenzene emerging as the optimal solvent. The small molecular size of N-DMBI enables highly efficient doping within a remarkably short duration (10 s) while ensuring prolonged stability in air and at high temperature (150 °C). Furthermore, Joule annealing of the yarns significantly improves the n-doping efficiency. Consequently, thermoelectric power factors (PFs) of 2800, 2390, and 1534 µW m-1  K-2 are achieved at 200, 150, and 30 °C, respectively. The intercalation of N-DMBI molecules significantly suppresses the thermal conductivity, resulting in the high figure of merit (ZT) of 1.69×10-2 at 100 °C. Additionally, a π-type thermoelectric module is successfully demonstrated incorporating both p- and n-doped CNT yarns. This study offers an efficient doping strategy for achieving CNT yarns with high thermoelectric performance, contributing to the realization of lightweight and mechanically flexible CNT-based thermoelectric devices.

5.
Trials ; 25(1): 53, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38225659

RESUMO

BACKGROUND: Endoscopic submucosal dissection (ESD) is the standard treatment for early gastric neoplasms (EGN). Controlling intraoperative bleeding is crucial for ensuring safe and reliable procedures. ESD using the spray coagulation mode (SCM-ESD) has been developed to control bleeding more effectively than ESD using the conventional forced coagulation mode (FCM-ESD). This study aims to compare the hemostatic efficacies of SCM-ESD and FCM-ESD. METHODS: This multicenter, prospective, parallel, randomized, open-label superiority trial will be conducted in five Japanese institutions. Patients with a preoperative diagnosis of intramucosal EGC will be randomized to undergo either SCM-ESD or FCM-ESD. The primary outcome measure is the completion of ESD with an electrosurgical knife alone, without the use of hemostatic forceps. Secondary outcomes include the number and duration of hemostasis using hemostatic forceps, procedure time, curability, and safety. A total of 130 patients will be enrolled in this study. DISCUSSION: This trial will provide evidence on the hemostatic efficacy of SCM-ESD compared with FCM-ESD in patients with intramucosal EGN, potentially improving the safety and reliability of ESD procedures. TRIAL REGISTRATION: The trial has been registered at the University Hospital Medical Information Network Clinical Trials Registration (UMIN-CTR) as UMIN000040518. The reception number is R000054009.


Assuntos
Ressecção Endoscópica de Mucosa , Hemostáticos , Neoplasias Gástricas , Humanos , Ressecção Endoscópica de Mucosa/efeitos adversos , Hemostáticos/efeitos adversos , Neoplasias Gástricas/cirurgia , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento , Hemostasia , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
6.
Dig Endosc ; 36(1): 40-48, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37079002

RESUMO

OBJECTIVE: This study was performed to evaluate whether the use of CAD EYE (Fujifilm, Tokyo, Japan) for colonoscopy improves colonoscopy quality in gastroenterology trainees. METHODS: The patients in this multicenter randomized controlled trial were divided into Group A (observation using CAD EYE) and Group B (standard observation). Six trainees performed colonoscopies using a back-to-back method in pairs with gastroenterology experts. The primary end-point was the trainees' adenoma detection rate (ADR), and the secondary end-points were the trainees' adenoma miss rate (AMR) and Assessment of Competency in Endoscopy (ACE) tool scores. Each trainee's learning curve was evaluated using a cumulative sum (CUSUM) control chart. RESULTS: We analyzed data for 231 patients (Group A, n = 113; Group B, n = 118). The ADR was not significantly different between the two groups. Group A had a significantly lower AMR (25.6% vs. 38.6%, P = 0.033) and number of missed adenomas per patient (0.5 vs. 0.9, P = 0.004) than Group B. Group A also had significantly higher ACE tool scores for pathology identification (2.26 vs. 2.07, P = 0.030) and interpretation and identification of pathology location (2.18 vs. 2.00, P = 0.038). For the CUSUM learning curve, Group A showed a trend toward a lower number of cases of missed multiple adenomas by the six trainees. CONCLUSION: CAD EYE did not improve ADR but decreased the AMR and improved the ability to accurately locate and identify colorectal adenomas. CAD EYE can be assumed to be beneficial for improving colonoscopy quality in gastroenterology trainees. TRIAL REGISTRATION: University Hospital Medical Information Network Clinical Trials Registry (UMIN000044031).


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Inteligência Artificial , Estudos Prospectivos , Competência Clínica , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Adenoma/diagnóstico , Adenoma/patologia , Pólipos do Colo/diagnóstico
7.
Allergol Int ; 73(2): 264-274, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37914545

RESUMO

BACKGROUND: Non-IgE-mediated gastrointestinal food allergies (non-IgE-GIFAs) seem to be increasing rapidly worldwide. However, nationwide studies have been limited to food-protein-induced enterocolitis (FPIES) and food-protein-induced allergic proctocolitis (FPIAP), with little attention to other non-IgE-GIFA subgroups. The aim of this study was to elucidate the clinical features of all patients with non-IgE-GIFAs, not just certain subgroups. METHODS: We conducted a nationwide cross-sectional survey of non-IgE-GIFAs in Japan from April 2015 through March 2016. A questionnaire was sent to hospitals and clinics throughout Japan. The questionnaire asked about the number of physician-diagnosed non-IgE-GIFA patients, the status of fulfillment of the diagnostic criteria, tentative classification into 4 clusters based on the initial symptoms, the day of onset after birth, complications, and the suspected offending food(s). RESULTS: The response rate to that questionnaire was 67.6% from hospitals and 47.4% from clinics. Analyses were conducted about "diagnosis-probable" patient cohort (n = 402) and the "diagnosis-confirmed" patients (n = 80). In half of the reported non-IgE-GIFA patients, onset occurred in the neonatal period. The patients were evenly distributed among 4 non-IgE-GIFA clusters. In Cluster 1, with symptoms of vomiting and bloody stool, the onset showed a median of 7 days after birth, which was the earliest among the clusters. Cow's milk was the most common causative food. CONCLUSIONS: In half of the patients, the onset of non-IgE-GIFAs was in the neonatal period. This highlights the importance of studying the pathogenesis in the fetal and neonatal periods.


Assuntos
Enterocolite , Hipersensibilidade Alimentar , Proctocolite , Lactente , Recém-Nascido , Feminino , Animais , Bovinos , Humanos , Hipersensibilidade Alimentar/diagnóstico , Hipersensibilidade Alimentar/epidemiologia , Hipersensibilidade Alimentar/complicações , Estudos Transversais , Enterocolite/diagnóstico , Enterocolite/epidemiologia , Alimentos , Proctocolite/diagnóstico , Proctocolite/epidemiologia , Proctocolite/complicações , Alérgenos
9.
Sci Rep ; 13(1): 2348, 2023 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-36759539

RESUMO

Deep-sea mining of hydrothermal deposits off the coast of Japan is currently under consideration, and environmental baseline studies of the area are required to understand possible impacts. The aim of this study is to clarify population structures of dominant benthic megafaunal species near hydrothermal vent fields in the Okinawa Trough, using a population genetics approach. We examined dominant deep-sea scavenging species including eels, several amphipods, and a decapod and performed population genetic analyses based on the mitochondrial cytochrome c oxidase subunit I region. Several sites were sampled within Okinawa Trough to examine intra-population diversity while two other locations 1400-2400 km away were chosen for inter-population comparisons. For synaphobranchid eels Simenchelys parasitica and Synaphobranchus kaupii, our results showed significant intra-population diversity but no inter-population genetic differentiation, suggesting strong genetic connectivity and/or large population sizes. In addition, single nucleotide polymorphism analysis also confirmed strong genetic connectivity for Simenchelys parasitica. Among scavenging amphipods, we detected seven putative species using molecular phylogenetic analysis. We evaluated population structures of the most abundant species of amphipods and a decapod species (Nematocarcinus lanceopes). Our results provide basic information on the genetic population structures of benthic megafaunal species near hydrothermal vent fields, which can be used to select candidate species for future connectivity analysis with high-resolution genetic markers and aid understanding of the potential population impacts of environmental disturbances.


Assuntos
Decápodes , Fontes Hidrotermais , Animais , Filogenia , Genética Populacional , Mitocôndrias/genética , Ecossistema
10.
Dig Dis Sci ; 68(4): 1426-1434, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36272038

RESUMO

BACKGROUND AND AIM: This study aimed to compare patients with and without sedation during emergency endoscopy for upper gastrointestinal bleeding (UGIB) and to clarify the safety and efficacy of sedation in emergency endoscopy. METHODS: We retrospectively collected 389 patients who underwent emergency endoscopy for UGIB at Ureshino Medical Center from 2016 to 2021. Patients were divided into two groups: sedation group during emergency endoscopy and nonsedation group. Clinical characteristics, patient status on admission, and UGIB etiology were evaluated. Treatment outcomes and adverse events were evaluated using propensity score matching (PSM), and risk factors for mortality from UGIB were investigated using Cox multivariate analysis. RESULTS: The sedation group was significantly younger, composed of a higher proportion of males, and had chronic liver disease. Blood pressure and hemoglobin level on admission were significantly higher in the sedation group. The main cause of bleeding was peptic ulcer, which was significantly higher in the nonsedation group. PSM created 133 matched pairs. The success rate of endoscopic hemostasis was similar in both groups, and procedure time was significantly shorter in the sedation group than in the nonsedation group (17.6 ± 10.0 versus 20.2 ± 10.2 min, P = 0.04). There were no significant differences in adverse events between groups. Cox multivariate analyses revealed that red blood cell transfusion [hazard ratio (HR) 4.45, P < 0.02] and rebleeding (HR 3.30, P = 0.03) were associated with increased risk of 30-day mortality from UGIB. CONCLUSIONS: Sedation reduced the procedure time during emergency endoscopy for UGIB. Sedation during emergency endoscopy for UGIB is acceptable for safe endoscopic procedures.


Assuntos
Hemorragia Gastrointestinal , Úlcera Péptica , Masculino , Humanos , Estudos Retrospectivos , Pontuação de Propensão , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Endoscopia Gastrointestinal/efeitos adversos , Úlcera Péptica/complicações
11.
BMC Gastroenterol ; 22(1): 445, 2022 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-36333660

RESUMO

BACKGROUND: This study aimed to evaluate the usefulness of discharge standards in outpatients undergoing sedative endoscopy by comparing the modified post-anesthetic discharge scoring system (MPADSS) and the modified Aldrete score. METHODS: We prospectively enrolled 376 outpatients who underwent gastrointestinal endoscopy under midazolam sedation; 181 outpatients were assessed regarding discharge after sedative endoscopy using the MPADSS (group M), and 195 patients were assessed by the modified Aldrete score (group A). The clinical characteristics, types of endoscopy, endoscopic outcomes, and anesthesia outcomes were evaluated between the two groups. We compared discharge score, recovery time, and adverse events using propensity-score matching. RESULTS: Propensity-score matching created 120 matched pairs. The proportion of patients who had a recovery time within 60 min after endoscopy was significantly higher in group A than that in group M (42.5% versus 25.0%, respectively; P < 0.01). The proportion of patients who required > 120 min of recovery time after endoscopy was significantly lower in group A than that in group M (0.0% versus 5.0%, respectively; P = 0.03). However, significantly more patients had drowsiness at discharge in group A compared with group M (19.1% versus 5.0%, respectively; P < 0.01). There was no significant difference in the adverse event rate within 24 h of discharge between the groups. CONCLUSIONS: Patients assessed by the modified Aldrete score were allowed to discharge earlier than those assessed by the MPADSS. However, a patient's level of consciousness should be assessed carefully, especially in patients who visit the hospital alone.


Assuntos
Anestésicos , Propofol , Humanos , Hipnóticos e Sedativos/efeitos adversos , Sedação Consciente/efeitos adversos , Pacientes Ambulatoriais , Alta do Paciente , Pontuação de Propensão , Endoscopia Gastrointestinal/efeitos adversos , Propofol/efeitos adversos
12.
Plant Biotechnol (Tokyo) ; 39(2): 185-189, 2022 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-35937534

RESUMO

The brassinosteroid (BR) phytohormone is an important regulator of plant growth. To identify novel transcription factors that regulate BR responses, we screened chimeric repressor gene silencing technology (CRES-T) plants, in which transcription factors were converted into chimeric repressors by the fusion of SRDX plant-specific repression domain, with brassinazole (Brz), an inhibitor of BR biosynthesis. We identified that a line that expressed the chimeric repressor for zinc finger homeobox transcription factor, BRASSINOSTEORID-RELATED-HOMEOBOX-2 (BHB2-sx), exhibited Brz-hypersensitive phenotype with shorter hypocotyl under dark, dwarf and round and dark green leaves similar to BR-deficient phenotype. Similar to BHB2-sx plants, bhb2 knockout mutant also exhibited Brz hypersensitive phenotype. In contrast, ectopic expression of BHB2 (BHB2-ox) showed hypocotyl elongation phenotype (BR excessive), showing decrease to Brz sensitivity. The expression of the DWF4 and CPD BR biosynthesis genes was repressed in BHB2-sx plants, whereas it was enhanced in BHB2-ox plants. The BR deficient-like phenotype of BHB2-sx plants was partially restored by treatment with brassinolide (BL), indicating that the BR deficient phenotype of BHB2-sx plant may be due to suppression of BR biosynthesis. Our results indicate that BHB2 is a positive regulator of BR response may be due to the promotion of BR biosynthesis genes.

13.
Plant Biotechnol (Tokyo) ; 39(2): 209-214, 2022 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-35937537

RESUMO

Brassinosteroid (BR) is a phytohormone that acts as important regulator of plant growth. To identify novel transcription factors that may be involved in unknown mechanisms of BR signaling, we screened the chimeric repressor expressing plants (CRES-T), in which transcription factors were converted into chimeric repressors by the fusion of SRDX plant-specific repression domain, to identify those that affect the expression of BR inducible genes. Here, we identified a homeobox-leucine zipper type transcription factor, BRASSINOSTEROID-RELATED-HOMEOBOX 3 (BHB3), of which a chimeric repressor expressing plants (BHB3-sx) significantly downregulated the expression of BAS1 and SAUR-AC1 that are BR inducible genes. Interestingly, ectopic expression of BHB3 (BHB3-ox) also repressed the BR inducible genes and shorten hypocotyl that would be similar to a BR-deficient phenotype. Interestingly, both BHB3-sx and BHB3-ox showed pale green phenotype, in which the expression of genes related photosynthesis and chlorophyll contents were significantly decreased. We found that BHB3 contains three motifs similar to the conserved EAR-repression domain, suggesting that BHB3 may act as a transcriptional repressor. These results indicate that BHB3 might play an important role not only to the BR signaling but also the regulation of greenings.

15.
Nanotechnology ; 33(23)2022 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-35196260

RESUMO

Carbon nanotubes (CNTs) exhibit extremely high nanoscopic thermal/electrical transport and mechanical properties. However, the macroscopic properties of assembled CNTs are significantly lower than those of CNTs because of the boundary structure between the CNTs. Therefore, it is crucial to understand the relationship between the nanoscopic boundary structure in CNTs and the macroscopic properties of the assembled CNTs. Previous studies have shown that the nanoscopic phonon transport and macroscopic thermal transport in CNTs are improved by Joule annealing because of the improved boundary Van-der-Waals interactions between CNTs via the graphitization of amorphous carbon. In this study, we investigate the mechanical strength and thermal/electrical transport properties of CNT yarns with and without Joule annealing at various temperatures, analyzing the phenomena occurring at the boundaries of CNTs. The obtained experimental and theoretical results connect the nanoscopic boundary interaction of CNTs in CNT yarns and the macroscopic mechanical and transport properties of CNT yarns.

16.
J Stroke Cerebrovasc Dis ; 31(4): 106350, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35152132

RESUMO

OBJECTIVE: The use of a transradial approach utilizing a Simmons-shaped catheter for neurointervention has been steadily increasing. Although the right radial artery is commonly used, in interventional cardiology, the left transradial approach offers clear clinical benefits for right-handed patients. To the best of our knowledge, no previous studies have examined intracranial aneurysm embolization with the routine use of the left transradial approach. The aim of this study was to evaluate the technical feasibility of left transradial intracranial aneurysm embolization. METHODS: We conducted a retrospective review of a prospective database of consecutive patients who had undergone left transradial intracranial aneurysm coiling using a 6-French Simmons guiding sheath between January and August 2021. The following outcome variables were then analyzed: whether the catheterization was successful, the angiographical results, and the presence of any procedure-related complications. RESULTS: In total, 25 patients underwent left transradial coiling for 15 anterior and 10 posterior circulation aneurysms. The Simmons guiding sheath could be successfully shaped and cannulated into the targeted vessel in all patients. All aneurysms were completely embolized without any complications. Immediate postoperative angiograms showed Raymond 1 in 10 aneurysms (40.0%), Raymond 2 in 12 (48.0%), and Raymond 3a in 3 (12.0%). None of the patients required crossover to the right radial or femoral arteries, and no radial artery spasms or occlusions were observed. CONCLUSION: The results of this study suggest that the left transradial approach for intracranial aneurysm coiling is not only safe, effective, and technically feasible, but also provides improved comfort to right-handed patients.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Cateterismo/métodos , Catéteres , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Humanos , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/terapia , Artéria Radial/diagnóstico por imagem , Estudos Retrospectivos
17.
Dig Endosc ; 34(1): 171-179, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33971037

RESUMO

BACKGROUND AND AIM: Elobixibat is a novel ileal bile acid transporter inhibitor. This study aimed to compare the efficacy, tolerability, and safety of the combination of elobixibat and 1 L of polyethylene glycol formulation containing ascorbic acid (PEG-Asc) solution versus the combination of sodium picosulfate and 1-L PEG-Asc solution as bowel preparation for colonoscopy. METHODS: This multi-center, randomized, observer-blinded, non-inferiority study recruited 210 outpatients who were assigned to either the elobixibat plus 1-L PEG-Asc group (group A) or the sodium picosulfate plus 1-L PEG-Asc group (group B). The quality of the bowel cleansing level was assessed by the Boston Bowel Preparation Scale (BBPS) and compared the bowel cleansing level between the groups. Data regarding bowel preparation time, patients' tolerability, and adverse events were also analyzed. RESULTS: Data for 196 patients (99 in group A and 97 in group B) were analyzed finally. BBPS was comparable between group A and B (8.3 ± 0.9 vs. 8.3 ± 0.7; P = 0.88). Consequently, the adequate bowel preparation rate in groups A and B was 95.0% and 99.0%, respectively (-4.0%, 95% CI -9.3 to 1.5). Bowel preparation time in group A was similar to that in group B (348.2 ± 79.8 min vs. 330.8 ± 82.5 min; P = 0.13), whereas, sleep disturbance was significantly less frequent in group A than in group B (10.2% vs. 22.7%; P = 0.02). CONCLUSIONS: The combination of elobixibat and 1-L PEG-Asc can be considered an alternative bowel preparation for colonoscopy considering the equivalent bowel cleansing effect and less frequent sleep disturbance. The Japan Registry of Clinical Trials (jRCTs41180026).


Assuntos
Catárticos , Dipeptídeos , Ácido Ascórbico , Catárticos/efeitos adversos , Colonoscopia , Humanos , Polietilenoglicóis , Estudos Prospectivos , Tiazepinas
18.
Clin J Gastroenterol ; 15(1): 237-243, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34689312

RESUMO

We encountered a case of pancreatic neuroendocrine carcinoma (pNEC) diagnosed via pathological autopsy that was initially diagnosed clinically as G3 pancreatic neuroendocrine tumor (G3 pNET) and discussed the differences between these entities in the literature. A 76-year-old man was admitted to our department because of jaundice. Computed tomography revealed multiple round nodules in both lung fields, suggesting metastasis, and a mass lesion was detected in the head of the pancreas with poor contrast in the arterial phase and slight contrast enhancement in the equilibrium phase. Biopsy of the lungs and pancreas led to a diagnosis of multiple pulmonary metastases of G3 pNET. Because the lesions were unresectable, chemotherapy was administered. Treatment was started with everolimus for 5 weeks. However, the patient experienced severe loss of appetite and malaise, and the lung lesions progressed, prompting treatment discontinuation. Subsequently, the patient's disease progressed rapidly, and he died 99 days after the start of chemotherapy. We performed a pathological autopsy with the consent of the family because of the rapid tumor growth. A pathological autopsy revealed a final diagnosis of pNEC, which differed from the clinical diagnosis.


Assuntos
Carcinoma , Tumores Neuroendócrinos , Neoplasias Pancreáticas , Idoso , Autopsia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Humanos , Masculino , Tumores Neuroendócrinos/patologia , Pâncreas/patologia , Neoplasias Pancreáticas/patologia
19.
Brain Dev ; 44(1): 73-76, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34400011

RESUMO

Moebius syndrome (MBS) is a congenital disorder characterized by facial and abducens palsy, sometimes accompanied with other cranial nerve palsies and comorbid conditions. Anatomical anomalies of the brainstem are assumed to be major etiologies of MBS. Its phenotypic presentation can be variable. We report a female patient with MBS who presented with neurogenic bladder (NB). She was born via normal vaginal delivery. At birth, she showed bilateral abducens palsy and right facial palsy. We diagnosed MBS by cranial computed tomography scan and magnetic resonance imaging. She had recurrent urinary tract infection. Hydronephrosis was noted on ultrasonography and bilateral vesicoureteral reflux (grade 5) on voiding cystourethrography. Urodynamic investigation showed detrusor overactivity and detrusor-sphincter dyssynergia, which follow the pattern of NB resulting from infrapontine-suprasacral lesions. Patients with MBS have lower brainstem dysfunction, and accordingly we should be aware of NB.


Assuntos
Síndrome de Möbius/complicações , Síndrome de Möbius/diagnóstico , Bexiga Urinaria Neurogênica/etiologia , Pré-Escolar , Feminino , Humanos , Masculino , Síndrome de Möbius/patologia , Síndrome de Möbius/fisiopatologia , Ponte/patologia , Ponte/fisiopatologia , Urodinâmica
20.
Clin J Gastroenterol ; 15(1): 157-163, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34716544

RESUMO

An 86-year-old woman presented with a history of endoscopic papillary sphincterotomy for bile duct stones and diverticulitis. The patient was admitted as an emergency case of acute cholangitis due to choledocholithiasis, underwent endoscopic bile duct stenting, and was discharged with a plan for endoscopic lithotripsy. One month later, the patient was readmitted owing to abdominal pain. Abdominal computed tomography at admission showed that the bile duct stent had migrated to the sigmoid colon and the presence of a small amount of extraintestinal gas, suggesting a colonic perforation. Lower gastrointestinal endoscopy showed adhesions and intestinal stenosis in the sigmoid colon, probably after diverticulitis, and the bile duct stent that had perforated the same site. The stent was removed and endoscopic closure of the perforation was performed using an over-the-scope clip. Abdominal computed tomography 8 days after the closure showed no extraintestinal gas. The patient resumed eating and was discharged on the 14th day of admission. There was no recurrence of abdominal pain. Endoscopic closure of sigmoid colon perforation due to bile duct stent migration using an over-the-scope clip has not been reported thus far, and it may be a new treatment option in the future.


Assuntos
Colo Sigmoide , Perfuração Intestinal , Idoso de 80 Anos ou mais , Ductos Biliares , Colangiopancreatografia Retrógrada Endoscópica , Colo Sigmoide/diagnóstico por imagem , Colo Sigmoide/cirurgia , Feminino , Humanos , Perfuração Intestinal/diagnóstico por imagem , Perfuração Intestinal/etiologia , Perfuração Intestinal/cirurgia , Stents/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA