1.
Biosensors (Basel) ; 12(11)2022 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-36354490

RESUMO

COVID-19 (or SARS-CoV-2) has deeply affected human beings worldwide for over two years, and its flexible mutations indicate the unlikeliness of its termination in a short time. Therefore, it is important to develop a quantitative platform for direct COVID-19 detection and human status monitoring. Such a platform should be simpler than nucleic acid amplification techniques such as polymerase chain reaction, and more reliable than the disposable test kits that are based on immunochromatography. To fulfill these requirements, we conducted proof-of-concept experiments for the quantitative detection of spike glycoprotein peptides and antibodies in one platform, i.e., all-dielectric metasurface fluorescence (FL) sensors. The high capability to enhance FL intensity enabled us to quantitatively measure the glycoproteins and antibodies more efficiently compared with the previous methods reported to date. Furthermore, the intrinsic limit of detection in the metasurface FL sensors was examined via confocal microscopy and found to be less than 0.64 pg/mL for glycoprotein peptides. Moreover, the sensors had a dynamic range more than five orders that of the target concentrations, indicating extremely high sensitivity. These two-way functions of the metasurface FL sensors can be helpful in reducing daily loads in clinics and in providing quantitative test values for proper diagnosis and cures.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus/genética , Anticorpos Antivirais
2.
PLoS One ; 16(7): e0254029, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34197563

RESUMO

Development of a simple, rapid and specific assay for the simultaneous detection of Campylobacter spp. and Salmonella spp. based on duplex loop-mediated isothermal amplification (d-LAMP), combined with lateral-flow biosensor (LFB) is reported herein. LAMP amplicons of both pathogens were simultaneously amplified and specifically differentiated by LFB. The specificity of the d-LAMP-LFB was evaluated using a set of 68 target and 12 non-target strains, showing 100% inclusivity and exclusivity. The assay can simultaneously detect Campylobacter and Salmonella strains as low as 1 ng and 100 pg genomic DNA per reaction, respectively. The lowest inoculated detection limits for Campylobacter and Salmonella species in artificially contaminated chicken meat samples were 103 CFU and 1 CFU per 25 grams, respectively, after enrichment for 24 h. Furthermore, compared to culture-based methods using field chicken meat samples, the sensitivity, specificity and accuracy of d-LAMP- LFB were 95.6% (95% CI, 78.0%-99.8%), 71.4% (95% CI, 29.0%-96.3%) and 90.0% (95% CI, 73.4%-97.8%), respectively. The developed d-LAMP-LFB assay herein shows great potentials for the simultaneous detection of the Campylobacter and Salmonella spp. and poses a promising alternative approach for detection of both pathogens with applications in food products.


Assuntos
Campylobacter/isolamento & purificação , Galinhas/microbiologia , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Salmonella/isolamento & purificação , Animais , Técnicas Biossensoriais/normas , Campylobacter/genética , Campylobacter/patogenicidade , Análise de Alimentos , Microbiologia de Alimentos , Humanos , Limite de Detecção , Salmonella/genética , Salmonella/patogenicidade
3.
PLoS One ; 16(1): e0245144, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33411848

RESUMO

Clostridium perfringens is a key anaerobic pathogen causing food poisoning. Definitive detection by standard culture method is time-consuming and labor intensive. Current rapid commercial test kits are prohibitively expensive. It is thus necessary to develop rapid and cost-effective detection tool. Here, loop-mediated isothermal amplification (LAMP) in combination with a lateral-flow biosensor (LFB) was developed for visual inspection of C. perfringens-specific cpa gene. The specificity of the developed test was evaluated against 40 C. perfringens and 35 other bacterial strains, which showed no cross-reactivity, indicating 100% inclusivity and exclusivity. LAMP-LFB detection limit for artificially contaminated samples after enrichment for 16 h was 1-10 CFU/g sample, which was comparable to the commercial real-time PCR kit. The detection performance of LAMP-LFB was also compared to culture-based method using 95 food samples, which revealed the sensitivity (SE), specificity (SP) and Cohen's kappa coefficient (κ) of 88.0% (95% CI, 75.6%-95.4%), 95.5% (95% CI, 84.8%-99.4%) and 0.832 (95% CI, 0.721-0.943), respectively. Area under the receiver operating characteristic (ROC) curve was 0.918 (95% CI, 0.854-0.981), indicating LAMP-LFB as high relative accuracy test. In conclusion, LAMP-LFB assay is a low-cost qualitative method and easily available for routine detection of C. perfringens in food samples, which could serve as an alternative to commercial test kit.


Assuntos
Técnicas Biossensoriais , Clostridium perfringens/genética , Microbiologia de Alimentos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Limite de Detecção
4.
Int J Anal Chem ; 2016: 1432781, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28101104

RESUMO

In this study, we demonstrate a long-range surface plasmon resonance (LR-SPR) biosensor for the detection of whole cell by captured antigens A and B on the surface of red blood cells (RBCs) as a model. The LR-SPR sensor chip consists of high-refractive index glass, a Cytop film layer, and a thin gold (Au) film, which makes the evanescent field intensity and the penetration depth longer than conventional SPR. Therefore, the LR-SPR biosensor has improved capability for detecting large analytes, such as RBCs. The antibodies specific to blood group A and group B (Anti-A and Anti-B) are covalently immobilized on a grafting self-assembled monolayer (SAM)/Au surface on the biosensor. For blood typing, RBC samples can be detected by the LR-SPR biosensor through a change in the refractive index. We determined that the results of blood typing using the LR-SPR biosensor are consistent with the results obtained from the agglutination test. We obtained the lowest detection limits of 1.58 × 105 cells/ml for RBC-A and 3.83 × 105 cells/ml for RBC-B, indicating that the LR-SPR chip has a higher sensitivity than conventional SPR biosensors (3.3 × 108 cells/ml). The surface of the biosensor can be efficiently regenerated using 20 mM NaOH. In summary, as the LR-SPR technique is sensitive and has a simple experimental setup, it can easily be applied for ABO blood group typing.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA