Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Arrhythm ; 39(1): 52-60, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36733320

RESUMO

Background: Ventricular tachycardia (VT) non-inducibility at the end of ablation is associated with a less likely VT recurrence. However, it is not clear whether we should use VT non-inducibility as a routine end point of VT ablation. The aim of this study was to evaluate VT recurrence in patients in whom VT non-inducibility was not achieved at the end of the radiofrequency (RF) ablation and the factors attributing to the VT recurrence. Methods: We analyzed that 62 patients in whom VT non-inducibility was not achieved at the end of the RF ablation were studied. Results: Over 2 years, 22 (35%) of the cases had VT recurrences. A multivariate analysis showed that an LVEF ≥35% (HR: 0.19; 95% CI: 0.06-0.49; p < .01) and elimination of the clinical VT as an acute ablation efficacy (HR: 0.23; 95% CI: 0.04-0.81; p = .02) were independent predictors of fewer VT recurrences. RF ablation was associated with a 91.1% reduction in VT episodes. Conclusion: Even if VT non-inducibility was not achieved, patients with an LVEF ≥35% or in whom the clinical VT could be eliminated might be prevented from having VT recurrences. The validity of the VT non-inducibility of any VT should be evaluated considering each patient's background and the results of the procedure.

2.
J Cardiovasc Electrophysiol ; 34(3): 527-535, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36598438

RESUMO

BACKGROUND: Lesion gaps assessed by late-gadolinium enhancement magnetic resonance imaging (LGE-MRI) are associated with the atrial fibrillation (AF) recurrence after pulmonary vein isolation. Animal studies have demonstrated that the catheter-contact force (CF), stability, and orientation are strongly associated with lesion formation. However, the impact of those procedural factors on the lesion characteristics associated with AF recurrence has not been well discussed. METHODS: A total of 30 patients with paroxysmal AF who underwent catheter ablation were retrospectively enrolled. Radiofrequency (RF) applications were performed with 35 W for 30 s in a point-by-point fashion under esophageal temperature monitoring. The inter-lesion distance was 4 mm. The lesions were visualized by LGE-MRI 3 months postprocedure and assessed by the LGE volume (ml), gap number (GN), and average gap length (AGL [mm]). The gaps were defined as nonenhancement sites of >4 mm. The procedural factors including the catheter-CF, stability, and orientation were calculated on the NavX system. RESULTS: Six (20%) of 30 patients had AF recurrences 12 months postablation. A univariate analysis demonstrated that the AGL was associated with AF recurrence (hazard ratio [HR]: 1.20, confidence interval [CI]: 1.03-1.42, p = .02). All AF recurrence were found in patients with an AGL of >7 mm. The catheter-CF and stability were associated with an AGL of >7 mm, but not the orientation (CF-HR: 0.62, CI: 0.39-0.97, p = .038; stability-HR: 0.8, CI: 0.66-0.98, p = .027). CONCLUSIONS: RF ablation with a low CF and poor catheter stability has a potential risk of creating large lesion gaps associated with AF recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Meios de Contraste , Gadolínio , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Ablação por Cateter/métodos , Recidiva , Veias Pulmonares/cirurgia , Átrios do Coração , Resultado do Tratamento
3.
J Arrhythm ; 38(6): 1056-1062, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36524047

RESUMO

Background: It is uncertain whether cardiac resynchronization therapy with a defibrillator (CRT-D) provides better survival benefits than a CRT-pacemaker (CRT-P) in heart failure patients with a reduced ejection fraction (≦35%, HFrEF) treated with contemporary HF therapy. Methods: We retrospectively analyzed the ventricular arrhythmia (VAs; sustained ventricular tachycardia/fibrillation) events in HFrEF patients who underwent CRT without a prior history of VAs or aborted sudden cardiac death before the CRT implantation. Between January/2010 and December/2020, a CRT device was implanted in 79 HFrEF patients (mean age: 69 ± 12 years, male: 57, ischemic cardiomyopathy: 16). CRT-D and CRT-P devices were implanted in 50 and 29 patients, respectively, at each physician's discretion. CRT-Ds were indicated in younger patients than were CRT-Ps (66 ± 12 vs. 73 ± 12 years, p = 0.03), but the gender distribution did not differ (female, 24% [12 of 50] vs. 35% [10 of 29], p = 0.44). The VA events during a median follow-up of 3.5-years (interquartile range [IQR]:1.6-5.5) and their predictors were analyzed. Results: VA events occurred in 9 patients with CRT-Ds (18%) and one with a CRT-P (3%, p = 0.08). The VA event rate was significantly lower in patients without a prior non-sustained ventricular tachycardia (NSVT: ≥3 beats; rate, ≥120 bpm; lasting <30 s, HR 0.05; 95% CI 0.01-0.30; p < 0.01) and females (HR 0.11; 95% CI 0.01-0.93; p = 0.04). Of note, no female patients without a prior history of NSVT experienced VA events. Conclusion: HFrEF CRT candidates without a prior history of NSVT and females may obtain less benefit from a primary preventive defibrillator indication.

4.
J Arrhythm ; 38(3): 400-407, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35785370

RESUMO

Background: Corticosteroids are widely used in patients with cardiac sarcoidosis (CS). In addition, upgrading to cardiac resynchronization therapy (CRT) is sometimes needed. This study aimed to investigate the impact of corticosteroid use on the clinical outcomes following CRT upgrades. Methods: A total of 48 consecutive patients with non-ischemic cardiomyopathies who underwent CRT upgrades were retrospectively reviewed and divided into three groups: group 1 included CS patients taking corticosteroids before the CRT upgrade (n = 7), group 2, CS patients not taking corticosteroids before the CRT upgrade (n = 10), and group 3, non-CS patients (n = 31). The echocardiographic response, heart failure hospitalizations, and cardiovascular deaths were evaluated. Results: The baseline characteristics during CRT upgrades exhibited no significant differences in the echocardiographic data between the three groups. After the CRT upgrade, responses regarding the ejection fraction (EF) and end-systolic volume (ESV) were significantly lower in CS patients than non-CS patients (ΔEF: group 1, 6.7% vs. group 2, 7.7% vs. group 3, 13.6%; p = .039, ΔESV: 3.0 ml vs. -12.7 ml vs. -37.2 ml; p = .008). The rate of an echocardiographic response was lowest in group 1 (29%). There were, however, no significant differences in the cumulative freedom from a composite outcome among the three groups (p = .19). No cardiovascular deaths occurred in group 1. Conclusion: The echocardiographic response to an upgrade to CRT and the long-term prognosis in patients with CS should be carefully evaluated because of the complex etiologies and impact of immunosuppressive therapy.

5.
J Arrhythm ; 38(2): 221-231, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35387140

RESUMO

Background: Some of atrial fibrillation (AF) drivers are found in normal/mild late-gadolinium enhancement (LGE) areas, as well as moderate ones. The atrial wall thickness (AWT) has been reported to be important as a possible AF substrate. However, the AWT and degree of LGEs as an AF substrate has not been fully validated in humans. Objective: The purpose of this study was to evaluate the impact of the AWT in normal/mild LGE areas on AF drivers. Methods: A total of 287 segments in 15 persistent AF patients were assessed. AF drivers were defined as non-passively activated areas (NPAs), where rotational activation was frequently observed, and were detected by the novel real-time phase mapping (ExTRa Mapping), mild LGE areas were defined as areas with a volume ratio of the enhancement voxel of 0% to <10%. The AWT was defined as the minimum distance from the manually determined endocardium to the epicardial border on the LGE-MRI. Results: NPAs were found in 20 (18.0%) of 131 normal/mild LGE areas where AWT was significantly thicker than that in the passively activated areas (PAs) (2.5 ± 0.3 vs. 2.2 ± 0.3 mm, p < .001). However, NPAs were found in 41 (26.3%) of 156 moderate LGE areas where AWT was thinner than that of PAs (2.1 ± 0.2 mm vs. 2.23 ± 0.3 mm, p = .02). An ROC curve analysis yielded an optimal cutoff value of 2.2 mm for predicting the presence of an NPA in normal/mild LGE areas. Conclusion: The location of AF drivers in normal/mild LGE areas might be more accurately identified by evaluating AWT.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA