Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 13285, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858419

RESUMO

In this work we demonstrate a miniaturised imaging system based around a time-gated SPAD array operating in a "chip-on-tip" manner. Two versions of the system are demonstrated, each measuring 23 mm × 23 mm × 28 mm with differing fields of view and working distances. Initial tests demonstrate contrast between materials in widefield fluorescence imaging (WFLIm) mode, with frame rates of > 2 Hz achievable. Following this, WFLIm images of autofluorescence in ovine lung tissue are obtained at frame rates of ~ 1 Hz. Finally, the ability of the second system to perform simultaneous WFLIm and time of flight (aka Flourescence Lifetime Imaging Distance and Ranging, FLImDAR) is also tested. This shows that the system is capable of 4 mm resolution of object separation when tested on 3D printed samples. It is further demonstrated as being able to perform scene reconstruction on autofluorescent lung tissue. This system is, to date, the smallest chip on tip WFLIm system published, and is the first demonstration of the FLImDAR technique in a compact, portable system.

2.
Opt Express ; 32(4): 6481-6493, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38439349

RESUMO

Time-resolved fibre optic Raman distributed temperature sensing (DTS) measurements experience long measurement times due to a weak backscattered Raman signal inside optical fibres or limited detector count rates. Here, improvements to previous work based on individual detectors are demonstrated using a 512 pixel complementary-metal-oxide semiconductor (CMOS) single-photon avalanche diode (SPAD) line sensor array with integrated (on-chip) timing electronics. Multiplexed single photon counting increases count rate and decreases measurement time for practical applications. This allows temperature to be measured every 0.5 m with 0.7 °C accuracy and a 10 s measurement time using a 13.0 m optical fibre, performance over longer distance is also investigated.

3.
Biomed Opt Express ; 15(1): 212-221, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38223190

RESUMO

In this work a combined fluorescence lifetime and surface topographical imaging system is demonstrated. Based around a 126 × 192 time resolved single photon avalanche diode (SPAD) array operating in time correlated single-photon counting (TCSPC) mode, both the fluorescence lifetime and time of flight (ToF) can be calculated on a pixel by pixel basis. Initial tests on fluorescent samples show it is able to provide 4 mm resolution in distance and 0.4 ns resolution in lifetime. This combined modality has potential biomedical applications such as surgical guidance, endoscopy, and diagnostic imaging. The system is demonstrated on both ovine and human pulmonary tissue samples, where it offers excellent fluorescence lifetime contrast whilst also giving a measure of the distance to the sample surface.