Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 17(8): e0273748, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36037201

RESUMO

BACKGROUND: Data on awareness of HIV status among people living with HIV (PLHIV) are critical to estimating progress toward epidemic control. To ascertain the accuracy of self-reported HIV status and antiretroviral drug (ARV) use in the Nigeria HIV/AIDS Indicator and Impact Survey (NAIIS), we compared self-reported HIV status with HIV rapid diagnostic test (RDT) results and self-reported ARV use with detectable blood ARV levels. METHODS: On the basis of responses and test results, participants were categorized by HIV status and ARV use. Self-reported HIV status and ARV use performance characteristics were determined by estimating sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Proportions and other analyses were weighted to account for complex survey design. RESULTS: During NAIIS, 186,405 participants consented for interview out of which 58,646 reported knowing their HIV status. Of the 959 (weighted, 1.5%) who self-reported being HIV-positive, 849 (92.1%) tested HIV positive and 64 (7.9%) tested HIV negative via RDT and polymerase chain reaction test for discordant positive results. Of the 849 who tested HIV positive, 743 (89.8%) reported using ARV and 72 (10.2%) reported not using ARV. Of 57,687 who self-reported being HIV negative, 686 (1.2%) tested HIV positive via RDT, with ARV biomarkers detected among 195 (25.1%). ARV was detected among 94.5% of those who self-reported using ARV and among 42.0% of those who self-reported not using ARV. Overall, self-reported HIV status had sensitivity of 52.7% (95% confidence interval [CI]: 49.4%-56.0%) with specificity of 99.9% (95% CI: 99.8%-99.9%). Self-reported ARV use had sensitivity of 95.2% (95% CI: 93.6%-96.7%) and specificity of 54.5% (95% CI: 48.8%-70.7%). CONCLUSIONS: Self-reported HIV status and ARV use screening tests were found to be low-validity measures during NAIIS. Laboratory tests to confirm self-reported information may be necessary to determine accurate HIV and clinical status for HIV studies in Nigeria.


Assuntos
Síndrome da Imunodeficiência Adquirida , Infecções por HIV , Síndrome da Imunodeficiência Adquirida/tratamento farmacológico , Antirretrovirais/uso terapêutico , Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , Infecções por HIV/epidemiologia , Humanos , Nigéria/epidemiologia , Autorrelato
2.
PLOS Glob Public Health ; 2(11): e0001077, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36962660

RESUMO

Human Immunodeficiency Virus (HIV) diagnosis remains the gateway to HIV care and treatment. However, due to changes in HIV prevalence and testing coverage across different geopolitical zones, it is crucial to evaluate the national HIV testing algorithm as false positivity due to low prevalence could be detrimental to both the client and the service delivery. Therefore, we evaluated the performance of the national HIV rapid testing algorithm using specimens collected from multiple HIV testing services (HTS) sites and compared the results from different HIV prevalence levels across the six geopolitical zones of Nigeria. The evaluation employed a dual approach, retrospective, and prospective. The retrospective evaluation focused on a desktop review of program data (n = 492,880) collated from patients attending routine HTS from six geopolitical zones of Nigeria between January 2017 and December 2019. The prospective component utilized samples (n = 2,895) collected from the field at the HTS and tested using the current national serial HIV rapid testing algorithm. These samples were transported to the National Reference Laboratory (NRL), Abuja, and were re-tested using the national HIV rapid testing algorithm and HIV-1/2 supplementary assays (Geenius to confirm positives and resolve discordance and multiplex assay). The retrospective component of the study revealed that the overall proportion of HIV positives, based on the selected areas, was 5.7% (28,319/492,880) within the study period, and the discordant rate between tests 1 and 2 was 1.1%. The prospective component of the study indicated no significant differences between the test performed at the field using the national HIV rapid testing algorithm and the re-testing performed at the NRL. The comparison between the test performed at the field using the national HIV rapid testing algorithm and Geenius HIV-1/2 supplementary assay showed an agreement rate of 95.2%, while that of the NRL was 99.3%. In addition, the comparison of the field results with HIV multiplex assay indicated a sensitivity of 96.6%, the specificity of 98.2%, PPV of 97.0%, and Kappa Statistic of 0.95, and that of the NRL with HIV multiplex assay was 99.2%, 99.4%, 99.0%, and 0.99, respectively. Results show that the Nigeria national serial HIV rapid testing algorithm performed very well across the target settings. However, the algorithm's performance in the field was lower than the performance outcomes under a controlled environment in the NRL. There is a need to target testers in the field for routine continuous quality improvement implementation, including refresher trainings as necessary.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA