Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Trials ; 25(1): 426, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38943169

RESUMO

BACKGROUND: Current management of mesenteric ischemia is primarily endovascular stent treatment. Typical CMI symptoms are postprandial abdominal pain, food fear, weight loss, and diarrhea. Revascularization is often necessary, as mesenteric ischemia may progress to bowel necrosis and death if left untreated. This study aims to compare the outcome using bare metal stent (BMS) or covered stent (CS) in the endovascular treatment of chronic and acute on chronic mesenteric ischemia. METHODS: This is an investigator-driven, prospective, randomized, single-blinded, and single-center, national cohort study at the Copenhagen University Hospital, Denmark. A total of 98 patients with chronic mesenteric ischemia (CMI) and acute-on-chronic mesenteric ischemia (AoCMI) will be randomized to treatment with either BeSmooth BMS (Bentley Innomed GmbH) or BeGraft CS (Bentley Innomed GmbH). Randomization occurs intraoperatively after lesion crossing. DISCUSSION: There is currently no published data from prospective controlled trials regarding the preferred type of stent used for the treatment of chronic and acute-on-chronic mesenteric ischemia. This trial will evaluate the short- and long-term outcome of BMS versus CS when treating CMI and AoCMI, as well as the benefit of a more intense postoperative surveillance program. TRIAL REGISTRATION: ClinicalTrials.gov NCT05244629. Registered on February 8, 2022.


Assuntos
Isquemia Mesentérica , Stents , Humanos , Isquemia Mesentérica/terapia , Isquemia Mesentérica/cirurgia , Estudos Prospectivos , Método Simples-Cego , Doença Crônica , Dinamarca , Resultado do Tratamento , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Desenho de Prótese
2.
Ann Med Surg (Lond) ; 86(4): 1867-1872, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38576952

RESUMO

Background: Conventional peroral methods to visualize biliary strictures are not feasible in some patients with altered anatomy or biliary obstruction, and percutaneous transhepatic cholangioscopy can be used as an alternative procedure. This study aimed to retrospectively review the use of percutaneous transhepatic cholangiography using the SpyGlass DS technology (S-PTCS) during a 5-year period at a Danish tertiary referral centre. Materials and methods: All patients who underwent S-PTCS at a single Danish tertiary referral centre between 2016 and 2021 were retrospectively analyzed. The visual, technical, and overall success rates of S-PTCS were analyzed, as well as the complication rate. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of S-PTCS were calculated. Results: Twenty-two patients were included in the study. Visual, technical, and overall success of S-PTCS was achieved in 17/22, 22/22, and 21/22 patients, respectively. S-PTCS yielded a sensitivity of 83.3%, a specificity of 100%, a PPV of 100%, a NPV of 94.1%, and an accuracy of 95.4%. Complications occurred in 1/22 patients. Conclusion: S-PTCS is a safe modality, with high success rates, high predictive values, and a low rate of complications. This study suggests that S-PTCS is an alternative to conventional methods in patients with indeterminate biliary strictures where conventional methods were unfeasible.

3.
Surg Endosc ; 38(4): 2010-2018, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38413471

RESUMO

BACKGROUND: To investigate factors associated with risk for rebleeding and 30-day mortality following prophylactic transarterial embolization in patients with high-risk peptic ulcer bleeding. METHODS: We retrospectively reviewed medical records and included all patients who had undergone prophylactic embolization of the gastroduodenal artery at Rigshospitalet, Denmark, following an endoscopy-verified and treated peptic Sulcer bleeding, from 2016 to 2021. Data were collected from electronic health records and imaging from the embolization procedures. Primary outcomes were rebleeding and 30-day mortality. We performed logistical regression analyses for both outcomes with possible risk factors. Risk factors included: active bleeding; visible hemoclips; Rockall-score; anatomical variants; standardized embolization procedure; and number of endoscopies prior to embolization. RESULTS: We included 176 patients. Rebleeding occurred in 25% following embolization and 30-day mortality was 15%. Not undergoing a standardized embolization procedure increased the odds of both rebleeding (odds ratio 3.029, 95% confidence interval (CI) 1.395-6.579) and 30-day overall mortality by 3.262 (1.252-8.497). More than one endoscopy was associated with increased odds of rebleeding (odds ratio 2.369, 95% CI 1.088-5.158). High Rockall-score increased the odds of 30-day mortality (odds ratio 2.587, 95% CI 1.243-5.386). Active bleeding, visible hemoclips, and anatomical variants did not affect risk of rebleeding or 30-day mortality. Reasons for deviation from standard embolization procedure were anatomical variations, targeted treatment without embolizing the gastroduodenal artery, and technical failure. CONCLUSIONS: Deviation from the standard embolization procedure increased the risk of rebleeding and 30-day mortality, more than one endoscopy prior to embolization was associated with higher odds of rebleeding, and a high Rockall-score increased the risk of 30-day mortality. We suggest that patients with these risk factors are monitored closely following embolization. Early detection of rebleeding may allow for proper and early re-intervention.


Assuntos
Hemostase Endoscópica , Úlcera Péptica , Humanos , Estudos Retrospectivos , Hemostase Endoscópica/métodos , Fatores de Risco , Úlcera Péptica Hemorrágica/etiologia , Úlcera Péptica Hemorrágica/terapia , Úlcera Péptica/terapia , Recidiva
4.
Cardiovasc Intervent Radiol ; 47(5): 632-639, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38233575

RESUMO

PURPOSE: To evaluate the efficacy of a single perioperative dose of dexamethasone in reducing postembolization syndrome following prostatic artery embolization. MATERIALS AND METHODS: We conducted a single-center double-blind randomized controlled trial from March 2021 to May 2022 (NCT04588857). Participants were randomized to receive either i.v. 24 mg dexamethasone or saline. The primary outcome measures were temperature, pain, and quality of life in the first 5 days following prostatic artery embolization. Sample size of 60 patients was needed for the assessment of primary outcomes. Participants were followed for 6 months and assessed for a variety of secondary outcome measures including inflammatory markers and lower urinary tract symptoms severity. RESULTS: Due to lack of clinical effect and mild symptoms in the control group, the trial was terminated early. 31 participants (16 dexamethasone vs. 15 control) were enrolled and analyzed. A difference in mean temperature was observed on day 1 (37.23 ± 0.64 °C control vs 36.74 ± 0.41 °C dexamethasone, p = 0.02, 95% CI 0.09-0.89). Difference in pain (score out of 10) was seen only on day 5 (1.48 ± 1.2 control vs. 2.9 ± 2.24 dexamethasone, p = 0.04, 95% CI - 2.78-- 0.04). A difference in C-reactive protein values was observed on day 2 (108 [54-161] mg/l control vs 10 [5-33] mg/l dexamethasone, p < 0.01). No significant differences in other outcomes were observed. No side effects were recorded. CONCLUSIONS: Twenty-four milligrams of dexamethasone bolus is safe but does not reduce postembolization syndrome following prostatic artery embolization.


Assuntos
Dexametasona , Embolização Terapêutica , Próstata , Humanos , Masculino , Método Duplo-Cego , Embolização Terapêutica/métodos , Dexametasona/administração & dosagem , Dexametasona/uso terapêutico , Próstata/irrigação sanguínea , Idoso , Pessoa de Meia-Idade , Síndrome , Resultado do Tratamento , Sintomas do Trato Urinário Inferior/etiologia , Sintomas do Trato Urinário Inferior/terapia , Sintomas do Trato Urinário Inferior/tratamento farmacológico , Qualidade de Vida , Hiperplasia Prostática/terapia , Anti-Inflamatórios/administração & dosagem , Anti-Inflamatórios/uso terapêutico
6.
Injury ; 54(5): 1321-1329, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36907823

RESUMO

BACKGROUND: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an emerging and potentially life-saving procedure, necessitating qualified operators in an increasing number of centres. The procedure shares technical elements with other vascular access procedures using the Seldinger technique, which is mastered by doctors not only in endovascular specialties but also in trauma surgery, emergency medicine, and anaesthesiology. We hypothesised that doctors mastering the Seldinger technique (experienced anaesthesiologist) would learn the technical aspects of REBOA with limited training and remain technically superior to doctors unfamiliar with the Seldinger technique (novice residents) given similar training. METHODS: This was a prospective trial of an educational intervention. Three groups of doctors were enroled: novice residents, experienced anaesthesiologists, and endovascular experts. The novices and the anaesthesiologists completed 2.5 h of simulation-based REBOA training. Their skills were tested before and 8-12 weeks after training using a standardised simulated scenario. The endovascular experts, constituting a reference group, were equivalently tested. All performances were video recorded and rated by three blinded experts using a validated assessment tool for REBOA (REBOA-RATE). Performances were compared between groups and with a previously published pass/fail cutoff. RESULTS: Sixteen novices, 13 board-certified specialists in anaesthesiology, and 13 endovascular experts participated. Before training, the anaesthesiologists outperformed the novices by 30 percentage points of the maximum REBOA-RATE score (56% (SD 14.0) vs 26% (SD 17%), p<0.01). After training, there was no difference in skills between the two groups (78% (SD 11%) vs 78 (SD 14%), p = 0.93). Neither group reached the endovascular experts' skill level (89% (SD 7%), p<0.05). CONCLUSION: For doctors mastering the Seldinger technique, there was an initial inter-procedural transfer of skills advantage when performing REBOA. However, after identical simulation-based training, novices performed equally well to anaesthesiologists, indicating that vascular access experience is not a prerequisite to learning the technical aspects of REBOA. Both groups would need more training to reach technical proficiency.


Assuntos
Oclusão com Balão , Procedimentos Endovasculares , Choque Hemorrágico , Humanos , Estudos Prospectivos , Hemorragia/terapia , Procedimentos Endovasculares/métodos , Aorta/cirurgia , Oclusão com Balão/métodos , Ressuscitação/métodos , Catéteres
8.
J Vasc Surg ; 77(3): 770-777.e2, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36306934

RESUMO

OBJECTIVE: Prior reports of the low profile Zenith Alpha abdominal graft (Cook Medical Inc, Bloomington, IN) have shown impaired limb graft patency to be the primary causes of reintervention. Special notices from the manufacturer have indicated certain instructions for use (IFU) violations as the main reasons for these complications. In the present study, we assessed the incidence of limb graft occlusion (LGO) and analyzed the effects of the detailed anatomic risk factors for LGO highlighted in the IFU and previously reported studies. METHODS: A retrospective study was performed of 241 patients treated with the low profile Zenith Alpha at a single institution from October 1, 2015 to September 30, 2018. All computed tomography angiograms were analyzed using three-dimensional software. Data were extracted from the electronic medical records until the end of the study period (December 31, 2020). The cumulative incidence of LGO and LGO-related reinterventions were assessed. A regression analysis was performed to evaluate the possible risk factors associated with the development of LGO at specified time points. These included aortic and iliac diameters, graft component oversizing, iliac tortuosity and calcification, overlap of graft components, proximal alignment of ipsilateral and contralateral legs, and sealing zone in the external iliac artery. Reader agreement of iliac calcification and tortuosity was assessed in patients with LGO. RESULTS: A total of 33 limbs (7%) in 27 patients (11%) had become occluded. The cumulative incidence of LGO was 7% (95% confidence interval [CI], 5%-9%) per limb up to 3 years postoperatively. The previously described risk factors for LGO were studied using regression analysis; however, no positive association with LGO was identified. Heavily calcified common iliac arteries (CIAs) and external iliac arteries were protective against LGO compared with noncalcified vessels up to 3 years postoperatively (decreased risk, 17% [95% CI, -27% to -7%]; P = .001; and 15% [95% CI, -26 to -5]; P = .005, respectively). The reader agreement of iliac calcification and tortuosity showed substantial agreement (CIA intrareader kappa = 0.75; CIA interreader kappa = 0.62) and almost perfect agreement (intrareader kappa = 0.85; interreader kappa = 0.84), respectively. CONCLUSIONS: The cumulative incidence of LGO after endovascular aneurysm repair with the Zenith Alpha graft was 7% per limb up to 3 years postoperatively. None of the analyzed risk factors suggested by the IFUs or current literature were positively associated with LGO.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Stents , Aneurisma da Aorta Abdominal/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Fatores de Risco , Desenho de Prótese
9.
Eur Heart J Cardiovasc Imaging ; 23(6): 855-862, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34166489

RESUMO

AIMS: The role of atherosclerosis in the pathogenesis of aortic enlargement is uncertain. We aimed to evaluate the relationship between the diameters of the ascending, descending and abdominal aorta, and coronary artery calcification. METHODS AND RESULTS: Individuals in the Copenhagen General Population Study underwent thoracic and abdominal computed tomography. Maximal aortic diameters were measured in each aortic segment and coronary artery calcium scores (CACS) were calculated. Participants were stratified into five predefined groups according to CACSs and compared to aortic dimensions. The relation between aortic diameter and CACS was adjusted for risk factors for aortic dilatation in a multivariable model. A total of 2678 eligible individuals were included. In all segments of the aorta, aortic diameter was associated to CACSs, with mean increases in aortic diameters ranging from 0.7 to 3.5 mm in individuals with calcified coronary arteries compared to non-calcified subjects (P-value < 0.001). After correction for risk factors, individuals with CACS above 400 had larger ascending, descending and abdominal aortic diameter than the non-calcified reference group (P-value < 0.01). CONCLUSION: Enlarged thoracic and abdominal aortic vascular segments are associated with co-existing coronary artery calcification in the general population.


Assuntos
Doenças da Aorta , Doença da Artéria Coronariana , Calcificação Vascular , Aorta Abdominal/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/epidemiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Humanos , Fatores de Risco , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/epidemiologia
10.
Eur Radiol ; 32(4): 2404-2413, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34786614

RESUMO

OBJECTIVES: To evaluate the effects of center experience and a variety of patient- and procedure-related factors on patient radiation exposure during prostatic artery embolization (PAE) in three Scandinavian centers with different PAE protocols and levels of experience. Understanding factors that influence radiation exposure is crucial in effective patient selection and procedural planning. METHODS: Data were collected retrospectively for 352 consecutive PAE procedures from January 2015 to June 2020 at the three centers. Dose area product (DAP (Gy·cm2)) was selected as the primary outcome measure of radiation exposure. Multiple patient- and procedure-related explanatory variables were collected and correlated with the outcome variable. A multiple linear regression model was built to determine significant predictors of increased or decreased radiation exposure as reflected by DAP. RESULTS: There was considerable variation in DAP between the centers. Intended unilateral PAE (p = 0.03) and each 10 additional patients treated (p = 0.02) were significant predictors of decreased DAP. Conversely, increased patient body mass index (BMI, p < 0.001), fluoroscopy time (p < 0.001), and number of digital subtraction angiography (DSA) acquisitions (p < 0.001) were significant predictors of increased DAP. CONCLUSIONS: To minimize patient radiation exposure during PAE radiologists may, in collaboration with clinicians, consider unilateral embolization, pre-interventional CTA for procedure planning, using predominantly anteroposterior (AP) projections, and limiting the use of cone-beam CT (CBCT) and fluoroscopy. KEY POINTS: • Growing center experience and intended unilateral embolization decrease patient radiation exposure during prostatic artery embolization. • Patient BMI, fluoroscopy time, and number of DSA acquisitions are associated with increased DAP during procedures. • Large variation in radiation exposure between the centers may reflect the use of CTA before and CBCT during the procedure.


Assuntos
Embolização Terapêutica , Hiperplasia Prostática , Exposição à Radiação , Angiografia Digital/métodos , Artérias/diagnóstico por imagem , Embolização Terapêutica/métodos , Fluoroscopia , Humanos , Masculino , Próstata/irrigação sanguínea , Próstata/diagnóstico por imagem , Hiperplasia Prostática/diagnóstico por imagem , Hiperplasia Prostática/terapia , Doses de Radiação , Estudos Retrospectivos
11.
BMJ Open ; 11(11): e047878, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34725072

RESUMO

INTRODUCTION: Postembolisation syndrome (PES) is the most common side effect of vascular embolisation of solid organs. Although prophylactic corticosteroids are known to reduce the incidence and severity of PES, no trials investigating their efficacy have been conducted in men undergoing prostatic artery embolisation (PAE). We postulate that steroids can have a similar effect in reducing PES after PAE. This paper describes the rationale and detailed protocol for a randomised controlled trial evaluating the efficacy of dexamethasone (DEXA) in reducing PES after PAE. METHODS AND ANALYSIS: In this single-centre, randomised, double-blind, placebo-controlled trial, we will enrol 60 individuals undergoing PAE for benign prostatic hyperplasia. Participants will be randomised to receive IV DEXA (24 mg) or placebo (saline). The primary outcomes will be postprocedural fever, pain and quality of life. The secondary outcomes will include postprocedural nausea, postprocedural medicine usage, laboratory parameters (C reactive protein, prostate-specific antigen) and early PAE results. ETHICS AND DISSEMINATION: Ethics approval was obtained from the Danish Committee on Health Research Ethics in the Capital Region (H-20025910). The results from this trial will be disseminated through publication in peer-reviewed journals and national and international presentations. TRIAL REGISTRATION NUMBER: Clinicaltrials.gov identifier: NCT04588857; EudraCT number: 2020-000915-53.


Assuntos
Hiperplasia Prostática , Artérias , Dexametasona/uso terapêutico , Método Duplo-Cego , Humanos , Masculino , Próstata , Hiperplasia Prostática/terapia , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
12.
Cardiovasc Intervent Radiol ; 44(11): 1699-1708, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34476578

RESUMO

OBJECTIVE: To summarize the literature on trans-arterial embolization in inflammatory musculoskeletal conditions, focusing on efficacy and safety. MATERIALS AND METHODS: PRISMA guidelines were followed. A systematic literature search revealed 19 studies, with a total of 394 participants, eligible for inclusion. RESULTS: The included studies consisted of case reports/series and non-randomized interventional studies, with knee osteoarthritis and adhesive capsulitis of the shoulder as the most frequent conditions. In all studies except one, pain was reduced up to four years after treatment. All adverse events were transient. Due to high heterogeneity, meta-analysis was not possible. CONCLUSION: The included early studies showed encouraging results regarding efficacy and safety. However, randomized, placebo-controlled trials are warranted.


Assuntos
Doenças Musculoesqueléticas , Osteoartrite do Joelho , Humanos , Doenças Musculoesqueléticas/terapia , Manejo da Dor
14.
J Trauma Acute Care Surg ; 91(2): 310-317, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34259442

RESUMO

BACKGROUND: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an emergency procedure that is potentially lifesaving in major noncompressible torso hemorrhage. It may also improve outcome in nontraumatic cardiac arrest. However, the procedure can be technically challenging and requires the immediate presence of a qualified operator. Thus, evidence-based training and assessment of operator skills are essential for successful implementation and patient safety. A prerequisite for this is a valid and reliable assessment tool specific for the procedure. The aim of this study was to develop a tool for assessing procedural competence in REBOA based on best-available knowledge from international experts in the field. METHODS: We invited international REBOA experts from multiple specialties to participate in an anonymous three-round iterative Delphi study to reach consensus on the design and content of an assessment tool. In round 1, participants suggested items to be included. In rounds 2 and 3, the relevance of each suggested item was evaluated by all participants to reach consensus. Interround data processing was done systematically by a steering group. RESULTS: Forty panelists representing both clinical and educational expertise in REBOA from 16 countries (in Europe, Asia, and North and South America) and seven different specialties participated in the study. After 3 Delphi rounds and 532 initial item suggestions, the panelists reached consensus on a 10-item assessment tool with behaviorally anchored rating scales. It includes assessment of teamwork, procedure time, selection and preparation of equipment, puncture technique, guidewire handling, sheath handling, placement of REBOA catheter, occlusion, and evaluation. CONCLUSION: We present the REBOA-RATE assessment tool developed systematically by international experts in the field to optimize content validity. Following further studies of its validity and reliability, this tool represents an important next step in evidence-based training programs in REBOA, for example, using mastery learning. LEVEL OF EVIDENCE: Therapeutic, level V.


Assuntos
Aorta/cirurgia , Oclusão com Balão/métodos , Hemorragia/terapia , Ressuscitação/métodos , Competência Clínica , Consenso , Técnica Delphi , Emergências , Procedimentos Endovasculares/métodos , Hemorragia/prevenção & controle , Humanos , Internacionalidade , Treinamento por Simulação , Tronco
15.
J Trauma Acute Care Surg ; 91(4): 663-671, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34225347

RESUMO

BACKGROUND: Valid and reliable assessment of skills is essential for improved and evidence-based training concepts. In a recent study, we presented a novel tool to assess procedural skills in resuscitative endovascular balloon occlusion of the aorta (REBOA), REBOA-RATE, based on international expert consensus. Although expert consensus is a strong foundation, the performance of REBOA-RATE has not been explored. The study aimed to examine the reliability and validity of REBOA-RATE. METHODS: This was an experimental simulation-based study. We enrolled doctors with three levels of expertise to perform two REBOA procedures in a simulated scenario of out-of-hospital cardiac arrest. Procedures were video-recorded, and videos were blinded and randomized. Three clinical experts independently rated all procedures using REBOA-RATE. Data were analyzed using Messick's framework for validity evidence, including generalizability analysis of reliability and determination of a pass/fail standard. RESULTS: Forty-two doctors were enrolled: 16 novices, 13 anesthesiologists, and 13 endovascular experts. They all performed two procedures, yielding 84 procedures and 252 ratings. The REBOA-RATE assessment tool showed high internal consistency (Cronbach's α = 0.95) and excellent interrater reliability (intraclass correlation coefficient, 0.97). Assessment using one rater and three procedures could ensure overall reliability suitable for high-stakes testing (G-coefficient >0.80). Mean scores (SD) for the three groups in the second procedure were as follows: novices, 32% (24%); anesthesiologists, 55% (29%); endovascular experts, 93% (4%) (p < 0.001). The pass/fail standard was set at 81%, which all experts but no novices passed. CONCLUSION: Data strongly support the reliability and validity of REBOA-RATE, which successfully discriminated between all experience levels. The REBOA-RATE assessment tool requires minimal instruction, and one rater is sufficient for reliable assessment. Together, these are strong arguments for the use of REBOA-RATE to assess REBOA skills, allowing for competency-based training and certification concepts. LEVEL OF EVIDENCE: Diagnostic test, no or poor gold standard, level V.


Assuntos
Oclusão com Balão/normas , Competência Clínica/normas , Procedimentos Endovasculares/educação , Parada Cardíaca Extra-Hospitalar/terapia , Ressuscitação/educação , Aorta/cirurgia , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/normas , Humanos , Masculino , Manequins , Reprodutibilidade dos Testes , Ressuscitação/métodos , Ressuscitação/normas , Treinamento por Simulação/métodos
16.
J Vasc Surg ; 74(3): 979-987, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33684470

RESUMO

OBJECTIVE: Three-dimensional ultrasound (3D-US) has already demonstrated improved reproducibility with a high degree of agreement (intermodality variability), reproducibility (interoperator variability), and repeatability (intraoperator variability) compared with conventional two-dimensional ultrasound (2D-US) when estimating the maximum diameter of native abdominal aortic aneurysms (AAAs). The aim of the present study was, in a clinical, multicenter setting, to evaluate the accuracy of 3D-US with aneurysm model quantification software (3D-US abdominal aortic aneurysm [AAA] model) for endovascular aortic aneurysm repair (EVAR) sac diameter assessment vs that of computed tomography angiography (CTA) and 2D-US. METHODS: A total of 182 patients who had undergone EVAR from April 2016 to December 2017 and were compliant with a standardized EVAR surveillance program were enrolled from five different vascular centers (Rigshospitalet, Copenhagen, Denmark; Catharina Ziekenhuis, Eindhoven, Netherlands; L'hospital de la Timone, Paris, France; Cleveland Clinic, Cleveland, Ohio; and The Christ Hospital, Cincinnati, Ohio) in four countries. All image acquisitions were performed at the local sites (ie, 2D-US, 3D-US, CTA). Only the 2D-US and CTA readings were performed both locally and centrally. All images were read centrally by the US and CTA core laboratory. Anonymized image data were read in a randomized and blinded manner. RESULTS: The sample used to estimate the accuracy of the 3D-US AAA model and 2D-US included 164 patients and 177 patients, respectively. The Bland-Altman analysis revealed that the mean difference between CTA and 3D-US was -2.43 mm (95% confidence interval [CI], -5.20 to 0.14; P = .07) with a lower and upper limit of agreement of -8.9 mm (95% CI, -9.3 to -8.4) and 2.7 mm (95% CI, 2.3-3.2), respectively. For 2D-US and CTA, the mean difference was -3.62 mm (95% CI, -6.14 to -1.10; P = .002), with a lower and upper limit of agreement of -10.3 mm (95% CI, -10.8 to -9.8) and 2.5 mm (95% CI, 2-2.9), respectively. CONCLUSIONS: The 3D-US AAA model showed no significant difference compared with CTA for measuring the anteroposterior diameter, indicating less bias for 3D-US compared with 2D-US. Thus, 3D-US with AAA model software is a viable modality for anteroposterior diameter assessment for surveillance after EVAR.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Imageamento Tridimensional , Complicações Pós-Operatórias/diagnóstico por imagem , Ultrassonografia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
17.
Stem Cell Res Ther ; 12(1): 68, 2021 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-33468240

RESUMO

BACKGROUND: In recent years, adipose-derived stromal cells (ASCs) have been heavily studied for soft tissue regeneration, augmentation, and dermal wound healing. METHODS: In this review, we investigated the trends in injectable scaffolds for ASC delivery in the dermis, and injectable or implantable scaffolds for ASC delivery in the subcutis. A total of 547 articles were screened across three databases; of these, 22 studies were found to be eligible and were included. The scaffolds were subdivided and analyzed based on their tissue placement (dermis or subcutis), delivery method (injected or implanted), and by the origin of the materials (natural, synthetic, and combinatory). RESULTS: ASCs embedded in scaffolds generally showed improved viability. Neovascularization in the transplanted tissue was greater when undifferentiated ASCs were embedded in a combinatory scaffold or if differentiated ASCs were embedded in a natural scaffold. ASCs embedded in natural materials underwent more adipogenic differentiation than ASCs embedded in synthetic scaffolds, indicating an etiologically unknown difference that has yet to be described. Increased mechanical strength of the scaffold material correlated with improved outcome measurements in the investigated studies. Wound healing studies reported reduced healing time in all except one article due to contraction of the control wounds. CONCLUSIONS: In future clinical trials, we recommend embedding ASCs in injectable and implantable scaffolds for enhanced protection, retained viability, and improved therapeutic effects. TRIAL REGISTRATION: This review was registered with PROSPERO: ID=CRD42020171534 . The use of scaffolds as a vehicle for ASC delivery generally improved cell viability, angiogenesis, and wound healing in vivo compared to utilizing ASCs alone. ASCs embedded in natural materials induced more adipogenesis than ASCs embedded in synthetic materials. Adipogenic-induced ASCs further increased this effect. The included studies indicate that the seeded scaffold material influences the differentiation of ASCs in vivo. All studies investigating the mechanical strength of ASC scaffolds reported improved outcome measurements with improved mechanical strength. The results suggest that scaffolds, in general, are favorable for ASC delivery. We recommend initiating clinical studies using scaffolds based on mechanical properties and tunability to improve ASC viability. For fat regeneration, natural scaffolds are recommended.


Assuntos
Tecido Adiposo , Células Estromais , Adipogenia , Diferenciação Celular , Alicerces Teciduais , Cicatrização
18.
Ann Vasc Surg ; 72: 321-329, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33160060

RESUMO

BACKGROUND: To compare aortic sac changes after endovascular aneurysm repair (EVAR) assessed by three-dimensional ultrasound (3D-US), two-dimensional ultrasound (2D-US), and traditional computed tomographic angiography (CTA). METHODS: Using volume assessment with three-dimensional CTA (3D-CTA-volume) as the gold standard, this study investigated aortic sac changes at three and 12 months after EVAR with three different ultrasound methods (2D-US anterior-posterior (AP) diameter, 3D-US AP centerline diameter, and 3D-US partial volume), and traditional CT multiplanar outer-to-outer diameter (CT-MPR OTO diameter). From august 1st, 2011 to January 2014, consecutive EVAR patients (n = 113) were available for analysis in two time intervals; 1) between preoperative and three-month follow-up and 2) between three and 12 month follow-up. RESULTS: The risk of missing true aortic sac growth (false negative finding) at three-month postoperative visit using 3D-US partial volume, 3D-US AP centerline diameter, 2D-US AP diameter, and CT-MPR OTO diameter was 19%, 21%, 22%, and 18%, respectively. Corresponding low sensitivities (0% to 21%) and kappa-values (<0.50) in detecting aortic sac changes were found. The risk of missing true growth between three and 12 months were lower (6%, 5%, 6%, and 6%, respectively), and matching sensitivities 33%, 33%, 17%, and 17%, respectively. CONCLUSIONS: All tested methods for aortic sac changes were as good as traditional CT-MPR OTO diameter and corresponded poorly with 3D-CTA-volume at three months postoperative visit but substantially better after 12 months where the residual sac change was more profound.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Aortografia , Implante de Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Imageamento Tridimensional , Ultrassonografia , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do Tratamento
19.
Diagnostics (Basel) ; 10(10)2020 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-33066281

RESUMO

Dual-energy computed tomography (DECT) can estimate tissue vascularity and perfusion via iodine quantification. The aim of this systematic review was to outline current and emerging clinical applications of iodine quantification within the gastrointestinal tract using DECT. The search was conducted with three databases: EMBASE, Pubmed and The Cochrane Library. This identified 449 studies after duplicate removal. From a total of 570 selected studies, 30 studies were enrolled for the systematic review. The studies were categorized into four main topics: gastric tumors (12 studies), colorectal tumors (8 studies), Crohn's disease (4 studies) and miscellaneous applications (6 studies). Findings included a significant difference in iodine concentration (IC) measurements in perigastric fat between T1-3 vs. T4 stage gastric cancer, poorly and well differentiated gastric and colorectal cancer, responders vs. non-responders following chemo- or chemoradiotherapy treatment among cancer patients, and a positive correlation between IC and Crohn's disease activity. In conclusion, iodine quantification with DECT may be used preoperatively in cancer imaging as well as for monitoring treatment response. Future studies are warranted to evaluate the capabilities and limitations of DECT in splanchnic flow.

20.
Diagnostics (Basel) ; 10(9)2020 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-32878325

RESUMO

Postembolization syndrome (PES) is the most common side effect of vascular embolization of solid organs. The aim of this review was to determine the incidence of PES and its individual components after prostatic artery embolization (PAE). A systematic review with a pre-specified search strategy for PubMed, Embase, Web of Science and Cochrane Library was performed according to PRISMA guidelines. Studies in English regarding PAE in humans with 10 or more participants were eligible for inclusion. No restrictions on participant demographics or PAE technique were imposed. The search returned 378 references, of which 32 studies with a total of 2116 patients met the inclusion criteria. The results for overall PES frequency and individual PES components were presented as median (interquartile range, (IQR)). Overall median PES frequency was 25.5% (12.5-45.8). The two most frequent individual PES components were dysuria/urethral burning and local pain, with a median frequency of 21.7% (13.8-33.3) and 20% (5.4-29.4), respectively. Most outcome measures were characterized by a marked lack of uniformity and inconsistency in reporting across studies. Development of a uniform reporting system would help the clinicians recognize and treat PES accordingly.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA