1.
J Arthroplasty ; 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38423259

RESUMO

BACKGROUND: Preoperative intra-articular corticosteroid injections to the hip joint increase the risk of periprosthetic joint infection (PJI) during primary total hip arthroplasty (THA). This study aimed to determine the relationship between preoperative timing of intra-articular corticosteroid injections and PJI risk following THA using data from a single-center hospital. METHODS: This single-center, retrospective cohort study included patients who underwent a THA between 2014 and 2020. Medical records were checked for intra-articular corticosteroid injections and PJI within 1 year of surgery. Patients were categorized into groups based on whether they received "no injection" or "injection 0 to 3 months," "3 to 6 months," and "> 6 months prior to THA." Hazard ratios (HRs) for these groups were calculated using multivariate Cox regression analysis, correcting for potential confounders, and presented with 95% confidence intervals [95% CIs]. RESULTS: In total, 4,507 patients (5,909 THAs) were identified. A total of 1,581 patients (27%) received an injection prior to THA. Without considering the timing factor, no increased risk for PJI following an intra-articular injection was noted (P = .19). Comparing the specified groups using multivariate analysis, corticosteroid injection within 3 months of THA showed an increased risk of PJI (HR 2.63, 95% CI 1.18 to 5.87, P = .018), but this effect was not observed for the "injection 3 to 6 months" group (HR 1.51, 95% CI 0.74 to 3.08, P = .264). CONCLUSIONS: Corticosteroid injections administered up to 3 months prior to THA increased the risk of PJI within 1 year after THA, with an HR of 2.63; however, injections between 3 and 6 months before surgery did not have a significantly higher infection rate.

2.
J Arthroplasty ; 38(3): 470-475, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36126888

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) is a reliable procedure for end-stage osteoarthritis with excellent long-term survivorship, but approximately 15% of patients are not satisfied. Pain catastrophizing (PC) has been proposed as a potential cause but current evidence is limited to smaller studies with short-term follow-up. Our goal was to assess outcomes following TKA in a large cohort with and without PC. METHODS: A prospective comparative study was performed with patients undergoing unilateral primary TKA between 2019 and 2021 with 2-year follow-up. All patients completed a PC Scale questionnaire preoperatively and a score of minimum 30 was considered PC. Outcomes consisted of Knee injury and Osteoarthritis Outcome Score-Physical Function Shortform (KOOS-PS), Oxford Knee Score (OKS), numeric rating scale Pain, and aseptic revisions. Ultimately, 301 patients were included (mean age 69 years [range, 30-92 years], with 60.8% women). Forty four patients (14.6%) had PC. RESULTS: Preoperatively, PC patients had inferior KOOS-PS, inferior OKS, and more pain than non-PC patients (all P < .001). PC patients had more improvement from preoperatively to 6 months postoperatively for KOOS-PS, OKS, and pain (all P < .05) and to 12 months for KOOS-PS and OKS (both P < .005). Similarly, PC patients had more improvement from preoperative to 24 months for OKS (P = .003). At 24 months, however, PC patients reported more pain than non-PC patients. There was no difference in revision rates (P = .192). CONCLUSION: Patients who had PC reported worse function and pain preoperatively but had more improvement to 6 months and 12 months postoperatively. At 24 months, similar subjective function was noted, although PC patients reported more pain.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Feminino , Idoso , Masculino , Artroplastia do Joelho/métodos , Estudos Prospectivos , Osteoartrite do Joelho/cirurgia , Resultado do Tratamento , Dor/cirurgia , Catastrofização , Articulação do Joelho/cirurgia
3.
Hip Pelvis ; 34(4): 236-244, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36601610

RESUMO

Purpose: The most recent diagnostic criteria for periprosthetic joint infection (PJI) include the use of the alpha-defensin (AD) lateral-flow (LF) test, but hip and knee arthroplasties were usually combined in previous studies. This prospective study was designed to examine the accuracy of the AD-LF test for diagnosis of PJI in chronic painful total hip arthroplasties (THA). Materials and Methods: Patients with chronic painful hip arthroplasties were prospectively enrolled between March 2018 and May 2020. Exclusion criteria included acute PJI or an insufficient amount of synovial fluid. The modified Musculoskeletal Infection Society (MSIS) criteria were primarily used for PJI diagnosis. Fifty-seven patients were included in the analysis group. Revision surgery was not performed in 38 patients, for different reasons (clinical group); these patients remain "Schrödinger's hips": in such cases PJI cannot be excluded nor confirmed until you "open the box". Results: The result of the AD-LF test was positive in nine patients and negative in 48 patients. Six patients were diagnosed with PJI. AD-LF sensitivity (MSIS criteria) was 83% (95% confidence interval [CI] 36-100%) and specificity was 92% (95% CI 81-98%). The positive and negative predictive value were 56% and 98%, respectively. Conclusion: The AD test is useful in addition to the existing arsenal of diagnostic tools, and can be helpful in the decision-making process. Not all patients with chronical painful THA will undergo revision surgery. Consequently, in order to determine the reliable diagnostic accuracy of this test, future PJI diagnostic studies should include a second arm of "Schrödinger's hips".

4.
Injury ; 52(3): 316-323, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33257020

RESUMO

INTRODUCTION: There has been an increased interest in the role of preoperative posterior tilt, as measured on lateral radiographs, on the outcomes of internal fixation of non-displaced femoral neck fractures (FNF). The goal was to assess the available evidence for this in the literature. PATIENTS AND METHODS: PRISMA guidelines were followed. PubMed, Embase and Cochrane were searched on June 10th, 2020 for studies assessing the role of posterior tilt on outcomes of internal fixation of non-displaced FNF. Primary outcomes were non-union and fixation failure, avascular necrosis (AVN), treatment failure, and reoperation (excluding symptomatic hardware removal). Outcomes were reported in Odds Ratio (OR) with 95% confidence intervals [CI]. RESULTS: Fourteen studies and 3729 patients were included (mean age 76 years, 72% female, mean follow-up 25 months). Moderate evidence was noted for the following: patients with greater preoperative posterior tilt had an increased risk of non-union and fixation failure (OR 2.4 [1.3 - 4.3]; p = 0.006), no increased risk of AVN (p = 0.550), an increased risk of treatment failure (OR 6.0 [2.2 - 15.9]; p<0.001) and reoperation (OR 2.5 [1.4 - 4.4]; p = 0.002). Furthermore, a greater preoperative tilt of 9.0° [4.1° - 13.9°] for treatment failure and 6.1° [3.7° - 8.5°] (p<0.001) for reoperation were noted in the unsuccessfully treated groups when compared to the successfully treated groups. Four studies found a threshold for posterior tilt ranging from 7° to 20° CONCLUSION: There is moderate evidence that patients with non-displaced FNF and greater tilt have an increased risk of unsuccessful outcomes following internal fixation. Older patients with a preoperative tilt of ≥20° might benefit from arthroplasty surgery, although studies assessing the optimal threshold are needed.


Assuntos
Fraturas do Colo Femoral , Idoso , Artroplastia , Feminino , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia , Fixação Interna de Fraturas , Humanos , Masculino , Radiografia , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
5.
Clin Biomech (Bristol, Avon) ; 70: 192-196, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31644999

RESUMO

BACKGROUND: With an increasingly younger population and more active patients, assessment of functional outcome is more important than ever in patients undergoing total knee arthroplasty. Accelerometers have been used successfully to objectively evaluate gait quality in other fields. The aim of this study was to assess gait quality with accelerometers before and after surgery, and to assess added value of resulting parameters to patient reported outcome measures scores. METHODS: Sixty-five patients (mean age 65 years (range 41-75)) who underwent primary total knee arthroplasty were evaluated using a tri-axial trunk accelerometer preoperatively and 1 year after surgery. Gait quality parameters derived from the accelerometry data were evaluated in three dimensions at both time points. Factor analysis was performed on all outcome variables and changes from before to 1 year after surgery in the most representative variable for each factor were studied. FINDINGS: Factor analysis identified three separate gait quality factors, with questionnaire and gait quality parameters loading on different factors. Both gait quality factor scores and questionnaire factor scores improved significantly 1 year after surgery. As expected based on the factor analysis, only weak to moderate associations were found between patient reported outcome measures and gait quality before surgery, after surgery and in change scores. INTERPRETATION: The independence of patient reported outcome measures and gait quality parameters measured with trunk accelerometry indicates that gait quality parameters provide additional information on functional outcome after total knee arthroplasty. Providing caretakers with objectively measurable targets using accelerometry could help improve outcome of these patients.


Assuntos
Artroplastia do Joelho , Análise da Marcha , Osteoartrite do Joelho/fisiopatologia , Medidas de Resultados Relatados pelo Paciente , Acelerometria , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Estudos Prospectivos , Inquéritos e Questionários , Resultado do Tratamento , Caminhada
6.
Int Orthop ; 42(9): 2025-2034, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29679108

RESUMO

BACKGROUND: Fluorodeoxyglucose positron emission tomography (FDG-PET) is a novel method of assessing suspected periprosthetic hip infection. However, a heterogeneity of sensitivity and specificity using different diagnostic criteria across clinical studies has been published. The objective of this study is to evaluate the various diagnostic criteria using FDG-PET in diagnosing periprosthetic hip infection. METHODS: FDG-PET scans of patients suffering from painful hip prostheses between 2008 and 2015 were retrospectively reviewed. The PET images were considered positive for infection using five criteria: any increased uptake at the (1) bone-prosthesis-interface, (2) periprosthetic soft tissue (PST), or (3) both, (4) increased uptake in the bone-prosthesis-interface compared to the PST, and (5) increased uptake along the femoral bone-prosthesis-interface. The final diagnosis of infection was based on the pre-operative and intra-operative findings with clinical follow-up > 12 months. RESULTS: A total of 33 hip prostheses were evaluated in this study, of which 16 were determined to be infected and 17 uninfected. Any periprosthetic FDG uptake was found in all symptomatic prostheses (sensitivity 100%; specificity 0%). When increased uptake in the bone-prosthesis-interface (sensitivity 100%; specificity 65%) or PST (sensitivity 94%; specificity 59%) was considered infected, specificity increased. A higher intensity of uptake at the bone-prosthesis-interface than PST demonstrated only moderate specificity (sensitivity 44%; specificity 71%). The most specific criterion for infection was an increased FDG uptake along the femoral bone-prosthesis-interface (sensitivity 81%; specificity 94%). CONCLUSIONS: Our results demonstrated that the accuracy of FDG-PET is highly dependent of the diagnostic criteria used for periprosthetic hip infection. Only an acceptable diagnostic accuracy (sensitivity 81%; specificity 94%) was found when increased FDG uptake along the femoral bone-prosthesis-interface was considered positive for infection.


Assuntos
Prótese de Quadril/efeitos adversos , Tomografia por Emissão de Pósitrons/métodos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Fluordesoxiglucose F18/administração & dosagem , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/administração & dosagem , Estudos Retrospectivos , Sensibilidade e Especificidade
8.
Clin Orthop Relat Res ; 475(5): 1395-1410, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28050818

RESUMO

BACKGROUND: In the assessment of possible periprosthetic knee infection, various imaging modalities are used without consensus regarding the most accurate technique. QUESTIONS/PURPOSES: To perform a meta-analysis to compare the accuracy of various applied imaging modalities in the assessment of periprosthetic knee infection. METHODS: A systematic review and meta-analysis was conducted with a comprehensive search of MEDLINE and Embase® in accordance with the PRISMA and Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) recommendations to identify clinical studies in which periprosthetic knee infection was investigated with different imaging modalities. The sensitivity and specificity of each imaging technique were determined and compared with the results of microbiologic and histologic analyses, intraoperative findings, and clinical followup of more than 6 months. A total of 23 studies, published between 1990 and 2015, were included for meta-analysis, representing 1027 diagnostic images of symptomatic knee prostheses. Quality of the included studies showed low concerns regarding external validity, whereas internal validity indicated more concerns regarding the risk of bias. The most important concerns were found in the lack of uniform criteria for the diagnosis of a periprosthetic infection and the flow and timing of the included studies. Differences among techniques were tested at a probability less than 0.05 level. Where there was slight overlap of confidence intervals for two means, it is possible for the point estimates to be statistically different from one another at a probability less than 0.05. The z-test was used to statistically analyze differences in these situations. RESULTS: Bone scintigraphy was less specific than all other modalities tested (56%; 95% CI, 0.47-0.64; p < 0.001), and leukocyte scintigraphy (77%; 95% CI, 0.69-0.85) was less specific than antigranulocyte scintigraphy (95%; 95% CI, 0.88-0.98; p < 0.001) or combined leukocyte and bone marrow scintigraphy (93%; 95% CI, 0.86-0.97; p < 0.001). Fluorodeoxyglucose positron emission tomography (FDG-PET) (84%; 95% CI, 0.76-0.90) was more specific than bone scintigraphy (56%; 95% CI, 0.47-0.64; p < 0.001), and less specific than antigranulocyte scintigraphy (95%; 95% CI, 0.88-0.98; p = 0.02) and combined leukocyte and bone marrow scintigraphy (93%; 95% CI, 0.86-0.97; p < 0.001). Leukocyte scintigraphy (88%; 95% CI, 0.81-0.93; p = 0.01) and antigranulocyte scintigraphy (90%; 95% CI, 0.78-0.96; p = 0.02) were more sensitive than FGD-PET (70%; 95% CI, 0.56-0.81). However, because of broad overlapping of confidence intervals, no differences in sensitivity were observed among the other modalities, including combined bone scintigraphy (93%; 95% CI, 0.85-0.98) or combined leukocyte and bone marrow scintigraphy (80%; 95% CI, 0.66-0.91; p > 0.05 for all paired comparisons). CONCLUSIONS: Based on current evidence, antigranulocyte scintigraphy and combined leukocyte and bone marrow scintigraphy appear to be highly specific imaging modalities in confirming periprosthetic knee infection. Bone scintigraphy was a highly sensitive imaging technique but lacks the specificity needed to differentiate among various conditions that cause painful knee prostheses. FDG-PET may not be the preferred imaging modality because it is more expensive and not more effective in confirming periprosthetic knee infection. LEVEL OF EVIDENCE: Level III, diagnostic study.


Assuntos
Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/instrumentação , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Cintilografia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Medula Óssea/diagnóstico por imagem , Criança , Pré-Escolar , Feminino , Fluordesoxiglucose F18 , Granulócitos , Humanos , Articulação do Joelho/microbiologia , Leucócitos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Valor Preditivo dos Testes , Infecções Relacionadas à Prótese/microbiologia , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Resultado do Tratamento , Adulto Jovem
9.
Clin Spine Surg ; 30(6): E853-E856, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27548041

RESUMO

STUDY DESIGN: Retrospective cohort study comparing intraobserver and interobserver reliability of 3 different radiologic fusion classifications following uninstrumented single-level anterior lumbar interbody fusion. OBJECTIVE OF THE STUDY: The objective of the study was to compare the intraobserver and interobserver reliability of 3 different radiologic spinal fusion scoring systems. SUMMARY OF BACKGROUND DATA: Knowledge regarding radiologic spinal fusion is crucial when studying patients that were treated with lumbar interbody fusion. The scoring system should be reliable and reproducible. Various radiologic classification systems coexist, but the reliability of these systems has thus far not been compared in a single consecutive group of patients. The aim of the present study was the identification of the most valid scoring system in the assessment of interbody fusion. METHODS: We studied a retrospective consecutive cohort of 50 patients who underwent an anterior lumbar interbody fusion procedure by a single surgeon using a stand-alone cage performed between 1993 and 2002. Plain anterior-posterior, lateral radiographs, and flexion-extension radiographs were made during follow-up visits and were used for analysis. The interbody fusion was scored on these radiographic images using the 3 classification systems (Brantigan, Burkus, and the Radiographic Score) by 2 experienced musculoskeletal radiologists and 2 senior orthopedic spinal surgeons all of whom were blinded to clinical data and outcome. RESULTS: Of the 3 classifications included in the current study, the Burkus classification had a moderate interobserver agreement and a substantial to perfect intraobserver agreement. The other classifications (Bratingan and the Radiographic Score) showed only fair interobserver agreement and moderate to substantial agreement among all observers. No significant differences in reliability between orthopedic surgeons and radiologists were found for all 3 classifications. CONCLUSIONS: The Burkus classification system was classified as most reliable in this, but showed only moderate interobserver agreement. Therefore, the need for a more reliable classification system for the radiographic assessment of lumbar interbody fusion still exists to date.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Fusão Vertebral , Adulto , Idoso , Demografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Adulto Jovem
10.
J Med Case Rep ; 8: 419, 2014 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-25495338

RESUMO

INTRODUCTION: The present case report describes a patient who presented with an early complication after a unicompartmental knee arthroplasty. It is not the first case in this subject but the unique aspect of this case report rests on the timing in which the failure occurred. CASE PRESENTATION: A 64-year-old Caucasian man received a medial unicompartmental knee arthroplasty (Oxford® Partial Knee) due to isolated anteromedial osteoarthritis of his right knee. His initial recovery was good, however, after 3 months he presented with acute pain and a locked knee. Radiographs showed a complete loosening and migration of the femoral component. During revision surgery no clear explanation was found for failure of the femoral component. CONCLUSIONS: The most likely explanation for loosening is the combination of peak stresses on the posterior facet of the femoral components of a unicompartmental knee arthroplasty in a patient in a cross-legged knee position causing bone-cement or cement-implant interface failure. Further research is necessary in prosthetic designs and applications of the unicompartmental knee arthroplasty to determine the origin of this early complication.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho , Complicações Pós-Operatórias/diagnóstico por imagem , Falha de Prótese , Dor Aguda , Humanos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/cirurgia , Radiografia , Amplitude de Movimento Articular
11.
Acta Orthop Belg ; 80(1): 88-98, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24873091

RESUMO

Glenoid fractures are rare, and relatively little is known about their mechanism, fracture pattern and optimal treatment strategies. The avulsions and rim fractures are strongly associated with anterior shoulder dislocations. Fossa fractures are mostly seen in high energy trauma patients as direct impact of the humeral head against the glenoid fossa. CT-scanning can be very useful in diagnosing the extend of injury and relation of humeral head with the main fragment of the glenoid. Fracture classification systems, have been designed mainly based on trauma mechanism, location and severity of fracture pattern. Treatment depends on instability, the degree of displacement and the articular surface fragment size, but is conservative in most cases. Due to the increase of arthroscopic fixation possibilities, operative treatment may increase. In this review, we have tried to summarize the available evidence into a treatment algorithm for different types of glenoid fractures. With regard to best functional outcome, an anatomical and concentric joint restoration should be the goal of treatment. Outcome is generally good in conservative and operative treatment, but exact data is difficult to appreciate, due to heterogeneity and comorbidities in different studies.


Assuntos
Fraturas Ósseas , Escápula/lesões , Adulto , Feminino , Fraturas Ósseas/classificação , Fraturas Ósseas/patologia , Fraturas Ósseas/terapia , Humanos , Masculino
12.
J Nucl Med ; 55(7): 1122-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24868107

RESUMO

UNLABELLED: (18)F-fluoride PET is a promising noninvasive method for measuring bone metabolism and bone blood flow. The purpose of this study was to assess the performance of various clinically useful simplified methods by comparing them with full kinetic analysis. In addition, the validity of deriving bone blood flow from K1 of (18)F-fluoride was investigated using (15)O-H2O as a reference. METHODS: Twenty-two adults (mean age ± SD, 44.8 ± 25.2 y), including 16 patients scheduled for bone surgery and 6 healthy volunteers, were studied. All patients underwent dynamic (15)O-H2O and (18)F-fluoride scans before surgery. Ten of these patients had serial PET measurements before and at 2 time points after local bone surgery. During all PET scans, arterial blood was monitored continuously. (18)F-fluoride data were analyzed using nonlinear regression (NLR) and several simplified methods (Patlak and standardized uptake value [SUV]). SUV was evaluated for different time intervals after injection and after normalizing to body weight, lean body mass, and body surface area, and simplified measurements were compared with NLR results. In addition, changes in SUV and Patlak-derived fluoride influx rate (Ki) after surgery were compared with corresponding changes in NLR-derived Ki. Finally, (18)F-fluoride K1 was compared with bone blood flow derived from (15)O-H2O data, using the standard single-tissue-compartment model. RESULTS: K1 of (18)F-fluoride correlated with measured blood flow, but the correlation coefficient was relatively low (r = 0.35, P < 0.001). NLR resulted in a mean Ki of 0.0160 ± 0.0122, whereas Patlak analysis, for the interval 10-60 min after injection, resulted in an almost-identical mean Ki of 0.0161 ± 0.0117. The Patlak-derived Ki, for 10-60 min after injection, showed a high correlation with the NLR-derived Ki (r = 0.976). The highest correlation between Ki and lean body mass-normalized SUV was found for the interval 50-60 min (r = 0.958). Finally, changes in SUV correlated significantly with those in Ki (r = 0.97). CONCLUSION: The present data support the use of both Patlak and SUV for assessing fluoride kinetics in humans. However, (18)F-fluoride PET has only limited accuracy in monitoring bone blood flow.


Assuntos
Fluoretos/metabolismo , Adulto , Transporte Biológico , Osso e Ossos/irrigação sanguínea , Osso e Ossos/diagnóstico por imagem , Fluoretos/síntese química , Radioisótopos de Flúor , Humanos , Cinética , Modelos Biológicos , Cintilografia
13.
Rheumatol Int ; 33(4): 959-63, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22833241

RESUMO

With increasing age, there may be a decrease in femoral blood flow. In some patients, this may result in local ischaemia, which subsequently may lead to local degenerative changes. Consequently, bone blood flow may play an important role in the aetiology of osteoarthritis of the hip. Little is known about bone blood flow in the femoral head of patients with advanced hip osteoarthritis. The purpose of this study was to evaluate bone blood flow and metabolism in vivo in patients with osteoarthritis of the hip. Ten patients with symptomatic osteoarthritis of the hip were enrolled prospectively. Femoral bone blood flow and metabolism were measured using positron emission tomography together with H2(15)O and [(18)F]fluoride, respectively. Blood flow was 0.054 ± 0.032 mL cm(-3) min(-1) and 0.041 ± 0.012 mL cm(-3) min(-1) in symptomatic and contralateral femoral heads, respectively (p = 0.435). The net flux of fluoride from plasma to bone mineral (K i ) was significantly (p = 0.027) higher in the femoral head of the osteoarthritic hip (0.022 ± 0.012 mL cm(-3) min(-1)) than in that of the contralateral hip (0.007 ± 0.005 mL cm(-3) min(-1)). This study showed significant increase in bone metabolism in the proximal femur of patients with symptomatic osteoarthritis of the hip joint. There was no evidence of decreased blood flow.


Assuntos
Cabeça do Fêmur/irrigação sanguínea , Cabeça do Fêmur/metabolismo , Osteoartrite do Quadril/fisiopatologia , Fluxo Sanguíneo Regional/fisiologia , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea/fisiologia , Feminino , Cabeça do Fêmur/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/metabolismo , Radiografia , Cintilografia
14.
Mol Imaging Biol ; 10(5): 288-93, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18543040

RESUMO

PURPOSE: To evaluate bone blood flow and bone formation in patients after total hip revision surgery with impacted bone grafting using H2 15O and [18F]fluoride positron emission tomography (PET). PROCEDURES: To asses bone blood flow and bone metabolism in bone allograft after impaction grafting, four patients treated with total hip revision surgery were enrolled prospectively in this study. Six patients scheduled for primary hip arthroplasties were included as a control group. The study protocol consisted of three H2 15O and [18F]fluoride PET scans in each patient. RESULTS: Bone blood flow increased significantly compared to the preoperative state in patients treated for primary hip arthroplasty. In patients undergoing revision surgery, bone blood flow was twofold to threefold higher compared to the preoperative state, but did not reach significance. Bone metabolism in patients undergoing revision was threefold higher 2 weeks postoperatively compared to the primary hip group. We found a significant correlation between Ki and bone blood flow. CONCLUSIONS: Allogeneic bone grafts induce a higher rate of local periprosthetic bone formation compared to periprosthetic bone formation after a primary total hip placement. In vivo coupling between bone blood flow and bone metabolism suggests that bone metabolism in allogeneic bone grafts may partly rely on bone blood flow adaptations.


Assuntos
Osso e Ossos/metabolismo , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/metabolismo , Prótese de Quadril , Tomografia por Emissão de Pósitrons/métodos , Idoso , Deutério , Feminino , Radioisótopos de Flúor , Luxação do Quadril/cirurgia , Humanos , Masculino , Radioisótopos de Oxigênio , Projetos Piloto , Resultado do Tratamento
15.
J Arthroplasty ; 22(6): 818-27, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17826271

RESUMO

This meta-analysis was performed to summarize and compare the diagnostic performance and diagnostic accuracy of radiographic and scintigraphic techniques in the evaluation of patients suspected of having aseptically loose acetabular components. Twenty-eight studies, published between January 1975 and October 2004, presented sufficient data for quantitative analysis. The pooled sensitivity and specificity rates for plain radiography were 70% (95% confidence interval [CI] = 59%-79%) and 80% (95% CI = 73%-86%), respectively; those for subtraction arthrography were 89% (95% CI = 84%-93%) and 76% (95% CI = 68%-82%), respectively; and those for nuclear arthrography were 87% (95% CI = 57%-97%) and 64% (95% CI = 40%-82%), respectively. Finally, bone scintigraphy had a sensitivity of 67% (95% CI = 57%-76%) and a specificity of 75% (95% CI = 64%-83%). We found a significantly higher sensitivity for subtraction arthrography as compared with plain radiography and bone scintigraphy. Therefore, subtraction arthrography is recommended for use as an additional diagnostic technique when plain radiography is found to be inconclusive.


Assuntos
Artrografia , Artroplastia de Quadril/instrumentação , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Falha de Prótese , Técnica de Subtração , Acetábulo , Humanos , Cintilografia , Sensibilidade e Especificidade
16.
Arch Orthop Trauma Surg ; 126(5): 316-23, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16547724

RESUMO

BACKGROUND: Plain radiography, subtraction arthrography, nuclear arthrography, and bone scintigraphy are imaging techniques commonly used to identify aseptic femoral component loosening. Controversy exists about the relative utility of these techniques. PATIENTS AND METHODS: We evaluated the diagnostic accuracy and interobserver reliability of the four techniques in 78 consecutive patients (mean age 70 years, range 29-88 years) referred for evaluation of their femoral hip prostheses. The standard evaluation protocol consisted of plain radiography followed by subtraction arthrography, nuclear arthrography, and bone scintigraphy. Surgery or the subsequent clinical course of the patient was used as gold standard. RESULTS: Overall, plain radiography had a sensitivity and specificity of 81 and 74%, respectively. Subtraction arthrography had a sensitivity of 47% and a specificity of 78%. Nuclear arthrography had a sensitivity of 69% and a specificity of 76%, and bone scintigraphy had a sensitivity of 88% with a specificity of 50%. CONCLUSION: We found considerable interobserver variability in all four techniques. Multivariate regression analysis revealed that bone scintigraphy and nuclear arthrography together made a significant contribution to the diagnosis when used in combination with plain radiography and are, when plain radiography is inconclusive, useful additional diagnostic techniques for the detection of femoral component loosening.


Assuntos
Artrografia/métodos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Cintilografia , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Sensibilidade e Especificidade , Medronato de Tecnécio Tc 99m
17.
Eur J Radiol ; 56(1): 113-9, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15893898

RESUMO

OBJECTIVE: To summarize and compare the diagnostic accuracy of contrast and subtraction arthrography in the assessment of aseptic loosening of total hip arthroplasties. DESIGN: This meta-analysis was performed using methods described by the Cochrane Methods Group on Systematic Reviews of Screening and Diagnostic Tests. We included original, English-language papers published between January 1975 to October 2004 that examined contrast-enhanced arthrography with or without subtraction for diagnosis of loosening of total hip prostheses. A qualitative and quantitative analysis was performed by two investigators. RESULTS: With regard to the acetabular component, pooled sensitivity and specificity for contrast arthrography was 70% (95% confidence interval, 52-84) and 74% (95% CI, 53-87), respectively. Subtraction arthrography had a significantly higher sensitivity of 89% (95% CI, 84-93) (p=0.01), with a similar specificity of 76% (95% CI, 68-82). For the femoral component, pooled sensitivity and specificity for contrast arthrography were 63% (95% CI, 53-72) and 78% (95% CI, 68-86). Pooled estimates for subtraction arthrography revealed a significantly higher sensitivity of 86% (95% CI, 74-93) (p=0.003). Specificity was 85% (95% CI, 77-91) and was similar to the data of contrast arthrography (p=0.23). CONCLUSION: Using the present data we found that the subtraction arthrography is a sensitive technique for detection of loosening of total hip prostheses, offering added value over contrast arthrography, especially for evaluation of the femoral component.


Assuntos
Artrografia/métodos , Meios de Contraste/administração & dosagem , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Falha de Prótese , Técnica de Subtração , Adulto , Artroplastia de Quadril/efeitos adversos , Humanos , Curva ROC , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
J Bone Joint Surg Am ; 86(11): 2456-63, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15523018

RESUMO

BACKGROUND: The diagnosis of a loose total hip prosthesis is often established with use of radiographic and nuclear medicine techniques, but there is controversy about the relative utility of plain radiography, subtraction arthrography, nuclear arthrography, and bone scintigraphy. In this retrospective study, we evaluated the sensitivity, specificity, and interobserver reliability of these imaging modalities in patients suspected of having aseptic loosening of the acetabular component. METHODS: From 1994 to 1999, eighty-six consecutive patients with pain after a total hip arthroplasty were evaluated for possible loosening of the components. The imaging evaluation included plain radiography followed by a one-day protocol that included bone scintigraphy, subtraction arthrography, and nuclear arthrography. For this study, two experienced nuclear medicine physicians and two experienced radiologists, all of whom were blinded with respect to the clinical pretest data and the clinical outcome, retrospectively interpreted the diagnostic images. The sensitivity and the specificity of each imaging modality were established by comparing the findings obtained with each technique with those found at surgery or during the subsequent clinical course of the patient. Interobserver variability was determined with the intraclass correlation coefficient. RESULTS: Plain radiography had a sensitivity of 85% (95% confidence interval, 71 to 94) and a specificity of 85% (95% confidence interval, 66 to 96) in detecting aseptic loosening of the acetabular component, but it had only fair interobserver variability (intraclass correlation coefficient, 0.37). For subtraction arthrography, the sensitivity was 72% (95% confidence interval, 57 to 84), the specificity was 70% (95% confidence interval, 50 to 86), and there was good interobserver variability (intraclass correlation coefficient, 0.71). For nuclear arthrography, the sensitivity was 57% (95% confidence interval, 41 to 71), the specificity was 67% (95% confidence interval, 46 to 84), and there was fair interobserver variability (intraclass correlation coefficient, 0.24). For bone scintigraphy, the sensitivity was 83% (95% confidence interval, 69 to 92), the specificity was 67% (95% confidence interval, 46 to 84), and there was moderate interobserver variability (intraclass correlation coefficient, 0.43). CONCLUSIONS: Plain radiography had the highest diagnostic accuracy in the evaluation of aseptic loosening of the acetabular component. The diagnostic accuracy was increased when plain radiography was combined with bone scintigraphy or subtraction arthrography. However, we found considerable interobserver variability in image interpretation, even with experienced radiologists and nuclear medicine physicians.


Assuntos
Artroplastia de Quadril , Articulação do Quadril/diagnóstico por imagem , Falha de Prótese , Acetábulo , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Radiografia , Cintilografia , Sensibilidade e Especificidade , Técnica de Subtração
SELEÇÃO DE REFERÊNCIAS