Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
ACS Nano ; 18(10): 7424-7432, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38408195

RESUMO

Four-dimensional scanning transmission electron microscopy (4D-STEM) offers an attractive approach to simultaneously obtain precise structural determinations and capture details of local electric fields and charge densities. However, accurately extracting quantitative data at the atomic scale poses challenges, primarily due to probe propagation and size-related effects, which may even lead to misinterpretations of qualitative effects. In this study, we present a comprehensive analysis of electric fields and charge densities in both pristine and defective h-BN flakes. Through a combination of experiments and first-principle simulations, we demonstrate that while precise charge quantification at individual atomic sites is hindered by probe effects, 4D-STEM can directly measure charge transfer phenomena at the monolayer edge with sensitivity down to a few tenths of an electron and a spatial resolution on the order of a few angstroms.

2.
Ultramicroscopy ; 257: 113889, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38056397

RESUMO

Direct electron detection is currently revolutionizing many fields of electron microscopy due to its lower noise, its reduced point-spread function, and its increased quantum efficiency. More specifically to this work, Timepix3 is a hybrid-pixel direct electron detector capable of outputting temporal information of individual hits in its pixel array. Its architecture results in a data-driven detector, also called event-based, in which individual hits trigger the data off the chip for readout as fast as possible. The presence of a pixel threshold value results in an almost readout-noise-free detector while also defining the hit time of arrival and the time the signal stays over the pixel threshold. In this work, we have performed various experiments to calibrate and correct the Timepix3 temporal information, specifically in the context of electron microscopy. These include the energy calibration, and the time-walk and pixel delay corrections, reaching an average temporal resolution throughout the entire pixel matrix of 1.37±0.04ns. Additionally, we have also studied cosmic rays tracks to characterize the charge dynamics along the volume of the sensor layer, allowing us to estimate the limits of the detector's temporal response depending on different bias voltages, sensor thickness, and the electron beam ionization volume. We have estimated the uncertainty due to the ionization volume ranging from about 0.8 ns for 60 keV electrons to 8.8 ns for 300 keV electrons.

5.
Nat Commun ; 14(1): 4442, 2023 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-37488103

RESUMO

The synergy between free electrons and light has recently been leveraged to reach an impressive degree of simultaneous spatial and spectral resolution, enabling applications in microscopy and quantum optics. However, the required combination of electron optics and light injection into the spectrally narrow modes of arbitrary specimens remains a challenge. Here, we demonstrate microelectronvolt spectral resolution with a sub-nanometer probe of photonic modes with quality factors as high as 104. We rely on mode matching of a tightly focused laser beam to whispering gallery modes to achieve a 108-fold increase in light-electron coupling efficiency. By adapting the shape and size of free-space optical beams to address specific physical questions, our approach allows us to interrogate any type of photonic structure with unprecedented spectral and spatial detail.

6.
Sci Adv ; 8(40): eabq4947, 2022 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-36206335

RESUMO

Following optical excitations' life span from creation to decay into photons is crucial in understanding materials photophysics. Macroscopically, this is studied using optical techniques, such as photoluminescence excitation spectroscopy. However, excitation and emission pathways can vary at nanometer scales, preventing direct access, as no characterization technique has the relevant spatial, spectral, and time resolution. Here, using combined electron spectroscopies, we explore excitations' creation and decay in two representative optical materials: plasmonic nanoparticles and luminescent two-dimensional layers. The analysis of the energy lost by an exciting electron that is coincident in time with a visible-ultraviolet photon unveils the decay pathways from excitation toward light emission. This is demonstrated for phase-locked (coherent) interactions (localized surface plasmons) and non-phase-locked ones (point defect excited states). The developed cathodoluminescence excitation spectroscopy images energy transfer pathways at the nanometer scale, widening the available toolset to explore nanoscale materials.

7.
Ultramicroscopy ; 239: 113539, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35598348

RESUMO

The acquisition of a hyperspectral image is nowadays a standard technique used in the scanning transmission electron microscope. It relates the spatial position of the electron probe to the spectral data associated with it. In the case of electron energy loss spectroscopy (EELS), frame-based hyperspectral acquisition is much slower than the achievable rastering time of the scan unit (SU), which sometimes leads to undesirable effects in the sample, such as electron irradiation damage, that goes unperceived during frame acquisition. In this work, we have developed an event-based hyperspectral EELS by using a Timepix3 application-specific integrated circuit detector with two supplementary time-to-digital (TDC) lines embedded. In such a system, electron events are characterized by their positional and temporal coordinates, but TDC events only by temporal ones. By sending reference signals from the SU to the TDC line, it is possible to reconstruct the entire spectral image with SU-limited scanning pixel dwell time and thus acquire, with no additional cost, a hyperspectral image at the same rate as that of a single channel detector, such as annular dark-field. To exemplify the possibilities behind event-based hyperspectral EELS, we have studied the decomposition of calcite (CaCO3) into calcium oxide (CaO) and carbon dioxide (CO2) under the electron beam irradiation.

8.
Nano Lett ; 22(1): 319-327, 2022 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-34907775

RESUMO

Whispering-gallery mode resonators host multiple trapped narrow-band circulating optical resonances that find applications in quantum electrodynamics, optomechanics, and sensing. However, the spherical symmetry and low field leakage of dielectric microspheres make it difficult to probe their high-quality optical modes using far-field radiation. Even so, local field enhancement from metallic nanoparticles (MNPs) coupled to the resonators can interface the optical far field and the bounded cavity modes. In this work, we study the interaction between whispering-gallery modes and MNP surface plasmons with nanometric spatial resolution by using electron-beam spectroscopy with a scanning transmission electron microscope. We show that gallery modes are induced over a selective spectral range of the nanoparticle plasmons, and additionally, their polarization can be controlled by the induced dipole moment of the MNP. Our study demonstrates a viable mechanism to effectively excite high-quality-factor whispering-gallery modes and holds potential for applications in optical sensing and light manipulation.

9.
Ultramicroscopy ; 215: 112993, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32516700

RESUMO

This paper discusses the reconstruction of partially sampled spectrum-images to accelerate the acquisition in scanning transmission electron microscopy (STEM). The problem of image reconstruction has been widely considered in the literature for many imaging modalities, but only a few attempts handled 3D data such as spectral images acquired by STEM electron energy loss spectroscopy (EELS). Besides, among the methods proposed in the microscopy literature, some are fast but inaccurate while others provide accurate reconstruction but at the price of a high computation burden. Thus none of the proposed reconstruction methods fulfills our expectations in terms of accuracy and computation complexity. In this paper, we propose a fast and accurate reconstruction method suited for atomic-scale EELS. This method is compared to popular solutions such as beta process factor analysis (BPFA) which is used for the first time on STEM-EELS images. Experiments based on real as synthetic data will be conducted.

10.
Nano Lett ; 20(5): 2973-2979, 2020 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-31967839

RESUMO

Atomic vibrations and phonons are an excellent source of information on nanomaterials that we can access through a variety of methods including Raman scattering, infrared spectroscopy, and electron energy-loss spectroscopy (EELS). In the presence of a plasmon local field, vibrations are strongly modified and, in particular, their dipolar strengths are highly enhanced, thus rendering Raman scattering and infrared spectroscopy extremely sensitive techniques. Here, we experimentally demonstrate that the interaction between a relativistic electron and vibrational modes in nanostructures is fundamentally modified in the presence of plasmons. We finely tune the energy of surface plasmons in metallic nanowires in the vicinity of hexagonal boron nitride, making it possible to monitor and disentangle both strong phonon-plasmon coupling and plasmon-driven phonon enhancement at the nanometer scale. Because of the near-field character of the electron beam-phonon interaction, optically inactive phonon modes are also observed. Besides increasing our understanding of phonon physics, our results hold great potential for investigating sensing mechanisms and chemistry in complex nanomaterials down to the molecular level.

11.
Ultramicroscopy ; 212: 112912, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31812451

RESUMO

The evolution of the scanning modules for scanning transmission electron microscopes (STEM) allows now to generate arbitrary scan pathways, an approach currently explored to improve acquisition speed and to reduce electron dose effects. In this work, we present the implementation of a random scan operating mode in STEM achieved at the hardware level via a custom scan control module. A pre-defined pattern with fully shuffled raster order is used to sample the entire region of interest. Subsampled random sparse images can then be extracted at successive time frames, to which suitable image reconstruction techniques can be applied. With respect to the conventional raster scan mode, this method permits to limit dose accumulation effects, but also to decouple the spatial and temporal information in hyperspectral images. We provide some proofs of concept of the flexibility of the random scan operating mode, presenting examples of its applications in different spectro-microscopy contexts: atomically-resolved elemental maps with electron energy loss spectroscopy and nanoscale-cathodoluminescence spectrum images. By employing adapted post-processing tools, it is demonstrated that the method allows to precisely track and correct for sample instabilities and to follow spectral diffusion with a high spatial resolution.

12.
Nano Lett ; 15(2): 1229-37, 2015 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-25603194

RESUMO

Plasmon modes of the exact same individual gold nanoprisms are investigated through combined nanometer-resolved electron energy-loss spectroscopy (EELS) and cathodoluminescence (CL) measurements. We show that CL only probes the radiative modes, in contrast to EELS, which additionally reveals dark modes. The combination of both techniques on the same particles thus provides complementary information and also demonstrates that although the radiative modes give rise to very similar spatial distributions when probed by EELS or CL, their resonant energies appear to be different. We trace this phenomenon back to plasmon dissipation, which affects in different ways the plasmon signatures probed by these techniques. Our experiments are in agreement with electromagnetic numerical simulations and can be further interpreted within the framework of a quasistatic analytical model. We therefore demonstrate that CL and EELS are closely related to optical scattering and extinction, respectively, with the addition of nanometer spatial resolution.

13.
ACS Nano ; 7(5): 4006-13, 2013 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-23600708

RESUMO

Spatially resolved electron energy loss spectroscopy (SR-EELS) using scanning transmission electron microscope (STEM) allows the identification and determination of the spatial distribution of the components/elements of immuno-functionalized core-shell superparamagnetic magnetite nanoparticles. Here, we report that SR-EELS measurements allow the direct identification and study of the biological moieties (protein G and anti-HRP antibody) in complex bionanocarriers of relevance for biomedical applications. Our findings show that the biomacromolecules are located on specific areas on the nanoparticles' surface. In addition, efficiency of this functionalization was evaluated by means of biochemical techniques.


Assuntos
Anticorpos Imobilizados/análise , Anticorpos Imobilizados/química , Elétrons , Nanopartículas de Magnetita/química , Análise Espectral , Anticorpos Imobilizados/imunologia , Peroxidase do Rábano Silvestre/imunologia , Propriedades de Superfície
14.
Nano Lett ; 11(2): 568-73, 2011 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-21182283

RESUMO

We report the spectral imaging in the UV to visible range with nanometer scale resolution of closely packed GaN/AlN quantum disks in individual nanowires using an improved custom-made cathodoluminescence system. We demonstrate the possibility to measure full spectral features of individual quantum emitters as small as 1 nm and separated from each other by only a few nanometers and the ability to correlate their optical properties to their size, measured with atomic resolution. The direct correlation between the quantum disk size and emission wavelength provides evidence of the quantum confined Stark effect leading to an emission below the bulk GaN band gap for disks thicker than 2.6 nm. With the help of simulations, we show that the internal electric field in the studied quantum disks is smaller than what is expected in the quantum well case. We show evidence of a clear dispersion of the emission wavelengths of different quantum disks of identical size but different positions along the wire. This dispersion is systematically correlated to a change of the diameter of the AlN shell coating the wire and is thus attributed to the related strain variations along the wire. The present work opens the way both to fundamental studies of quantum confinement in closely packed quantum emitters and to characterizations of optoelectronic devices presenting carrier localization on the nanometer scale.


Assuntos
Iluminação/instrumentação , Nanotecnologia/instrumentação , Nanotubos/química , Nanotubos/ultraestrutura , Pontos Quânticos , Espectrofotometria Ultravioleta/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Tamanho da Partícula , Espalhamento de Radiação
15.
J Comput Assist Tomogr ; 26(6): 1057-62, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12488761

RESUMO

This work aims to improve the quality of scintigraphy. It evaluates the use of a large-hole collimator, the Computer Aided Collimation Gamma Camera Project (CACAO), in SPECT. Acquisition data from the same object were simulated for CACAO and for a conventional collimator. Better signal-to-noise ratios were found for CACAO images, whatever the number of emitted photons. This work demonstrates that high-resolution images may be obtained with large-hole collimators. The combination of CACAO and pixilated detectors may further improve radionuclide imaging.


Assuntos
Algoritmos , Cintilografia/métodos , Calibragem , Humanos , Processamento de Imagem Assistida por Computador , Fótons , Cintilografia/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA