Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Invest Surg ; 33(6): 520-529, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30644766

RESUMO

Objective: The disk-up sinus reamer (DSR) is a modified instrument used to elevate the maxillary sinus floor. This study aimed to compare the effects of modified DSR sinus floor elevation (DSFE) with osteotome sinus floor elevation (OSFE), both with simultaneous implant placement. Methods: Twelve miniature pigs were treated with DSFE on one side and OSFE on the other. Implants 9 mm in length were placed in six pigs without grafting, while implants 11 mm in length were placed in the other six pigs with grafting. After submerged healing for 3 months, vertical bone gain (VBG), general and histological observation, and bone contact ratio (BCR) were analyzed. Results: The mean maxillary residual bone height (RBH) when implants were placed was 6.45 ± 0.36 mm. In the no-grafting group, DSFE and OSFE had a similar VBG after 3 months. The grafting group with DSFE recorded a significantly higher VBG (VBG0: 7.83 ± 0.44 mm, VBG1: 7.54 ± 0.40 mm) than the graft group with OSFE (VBG0: 5.45 ± 0.56 mm, VBG1: 4.34 ± 2.15 mm) (p < 0.05). One implant became loose and the sinus mucosa of three pigs appeared metallic in color on the control side (OSFE). Conclusions: The effect of OSFE and DSFE is similar when there is no need for grafting. DSFE seems a better alternative method for sinus floor elevation with grafting when more VBG is needed.


Assuntos
Enxerto de Osso Alveolar/métodos , Implantação Dentária Endóssea/instrumentação , Seio Maxilar/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Levantamento do Assoalho do Seio Maxilar/instrumentação , Animais , Implantação Dentária Endóssea/métodos , Implantes Dentários , Feminino , Modelos Animais , Levantamento do Assoalho do Seio Maxilar/métodos , Suínos , Porco Miniatura
2.
J Prosthet Dent ; 122(4): 383-388, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30982624

RESUMO

STATEMENT OF PROBLEM: High rates of veneering chipping are a common prosthodontic complication of restorations with a titanium framework. A new bio high-performance polymer (BioHPP) based on polyetheretherketone (PEEK) has been introduced for denture superstructures. Clinical reports suggest that BioHPP could be used as an alternative framework material to support complete-arch restorations. However, peer-reviewed information is lacking regarding the performance of BioHPP as a framework material for implant-supported screw-retained fixed dental prostheses (FDPs) veneered with composite resin. PURPOSE: The purpose of this in vitro study was to evaluate and compare the bond strength of modified PEEK (BioHHP) and titanium with a veneering composite resin and compare the marginal fit and fracture resistance of implant-supported screw-retained FDPs fabricated by using computer-aided design and computer-aided manufacturing (CAD-CAM) frameworks veneered with composite resin. MATERIAL AND METHODS: A composite resin was bonded to 2 framework materials (n=20/group): pure titanium (Ti) and BioHPP (Bi). The shear bond strength (SBS) was determined after 24-hour wet storage. Furthermore, 20 3-unit CAD-CAM BioHPP and titanium frameworks were fabricated (n=10/group). The marginal fit between frameworks and abutments was evaluated by scanning electron microscopy by using the single-screw test. After thermocycling and mastication simulation, the fracture resistance of FDPs veneered with the composite resin was examined. The independent sample t test was used to evaluate differences (α=.05). RESULTS: Significantly higher shear bond strengths were obtained in group Bi (31.1 ±3.5 MPa) than in group Ti (20.5 ±1.8 MPa). The mean marginal gap width was 19 ±4 µm in group Bi and 16 ±6 µm in group Ti. Statistical tests showed no significant differences (P>.05). After loading, veneering chipping was observed at a load of 1960 ±233 N in group Ti. Although the BioHPP frameworks fractured at 1518 ±134 N, no chipping occurred. CONCLUSIONS: The bond strength of BioHPP with the composite resin was greater than that of titanium. CAD-CAM BioHPP frameworks exhibit good marginal fit and fracture resistance. BioHPP may be a suitable alternative to metal as a framework to be veneered with composite resin.


Assuntos
Prótese Dentária Fixada por Implante , Titânio , Resinas Compostas , Desenho Assistido por Computador , Materiais Dentários , Porcelana Dentária , Teste de Materiais , Polímeros , Zircônio
3.
Int J Oral Maxillofac Implants ; 29(6): 1446-53, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25397808

RESUMO

PURPOSE: Improving the peri-implant bone quality has notable clinical value in cases of osteoporosis following implant insertion. MATERIALS AND METHODS: In this study, strontium ranelate-loaded chitosan film was produced on a titanium surface in different concentrations of strontium ranelate (SR) (0, 2, 20, 40, and 80 mmol/L of the strontium ion [Sr2+]) with the expectation of utilizing the bone healing-enhancement effect of Sr2+. The physicochemical properties of SR-loaded chitosan films were characterized by x-ray diffraction (XRD), scanning electron microscopy (SEM), and Fourier transform infrared spectroscopy (FTIR). The release/dissolution mechanism was tested by inductively coupled plasma optical emission spectrometry (ICP-OES), and in vitro cell responses were evaluated using primary osteoblasts (POBs) in terms of cell proliferation, alkaline phosphatase (ALP) activity, and quantitative analysis of key osteoblastic gene expression. RESULTS: XRD and FTIR observation showed that only a few SRs reacted chemically with chitosan through hydrogen bonds or conjugate action. The initial burst release (70% to 85%) of Sr2+ occurred in the first 3 days and was followed by a slower release stage. At a low concentration (2 mmol/L or 20 mmol/L), SR-loaded chitosan film promoted cell responses of POBs with enhanced proliferation, ALP activity, and expression levels of bone morphogenetic protein 2 (BMP-2), runt-related transcription factor 2 (Runx-2), ALP, and osteocalcin, but at a high concentration (40 mmol/L or 80 mmol/L), it inhibited POB growth. CONCLUSION: These results indicated that SR-loaded chitosan film on a titanium surface promotes osteoblast proliferation and differentiation in a dose-dependent manner, which may represent a new approach in the treatment of a titanium implant.


Assuntos
Conservadores da Densidade Óssea/farmacologia , Quitosana/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Dentários/química , Osteoblastos/efeitos dos fármacos , Tiofenos/farmacologia , Titânio/química , Fosfatase Alcalina/análise , Animais , Conservadores da Densidade Óssea/química , Proteína Morfogenética Óssea 2/análise , Técnicas de Cultura de Células , Diferenciação Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Quitosana/química , Materiais Revestidos Biocompatíveis/química , Subunidade alfa 1 de Fator de Ligação ao Core/análise , Camundongos , Microscopia Eletrônica de Varredura , Osteocalcina/análise , Espectrofotometria Atômica , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície , Tiofenos/química , Fatores de Tempo , Difração de Raios X
4.
Saudi Med J ; 35(10): 1195-202, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25316463

RESUMO

OBJECTIVES: To evaluate masticatory efficiency (ME) and oral health-related quality of life (OHRQoL) in patients rehabilitated with implant-retained mandibular overdentures. METHODS: In this randomized controlled clinical trial, 50 edentulous patients visiting the Implant Center and Department of Prosthodontics, West China College of Stomatology, Sichuan University, Chengdu, China between June 2010 and June 2012 were selected and received 2 implant-retained mandibular overdenture treatments. All patients were rehabilitated with maxillary complete dentures. The ME and OHRQoL were determined both one month before the mandibular complete denture was anchored to the osseointegrated implants, and 6 months after anchoring. Paired t-tests were used to compare means of ME, and oral health impact profile-49 (OHIP-49)  domains scores between pre- and post-implant. Linear regression models were utilized to seek correlations between ME and OHIP domains scores. RESULTS: The ME increased from pre- to post-implant retained mandibular overdentures significantly (p<0.001). The total OHIP score and 4 subscales scores were changed significantly from pre- to post-implant; namely, functional limitation, psychological discomfort, physical disability, and physical pain. The total OHIP score, functional limitation, physical disability, and physical pain subscale scores were related to ME. CONCLUSION: Implant-retained mandibular over dentures can significantly improve patients' ME and OHRQoL. The improvement in OHRQoL is mainly because of the improved ME. An improved chewing experience, and pain relief also contributes to improvement of OHRQoL. 


Assuntos
Implantes Dentários , Prótese Total , Revestimento de Dentadura , Mastigação , Boca Edêntula/reabilitação , Qualidade de Vida , Idoso , Feminino , Humanos , Modelos Lineares , Masculino , Mandíbula , Maxila , Pessoa de Meia-Idade , Saúde Bucal , Resultado do Tratamento
5.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 43(4): 507-12, 2012 Jul.
Artigo em Chinês | MEDLINE | ID: mdl-22997885

RESUMO

OBJECTIVE: To develop a new local delivery system, zoledronic-acid-loaded chitosan/calcium phosphate ceramic, and to determine its characterization and in vitro response of osteoblast cells. METHODS: Zoledronic-acid-loaded chitosan/calcium phosphate ceramic were prepared by solution casting method at a concentration of 10(-5), 10(-4), and 10(-3) mol/L, respectively. The physicochemical properties of the resulting materials were determined using SEM and FTIR. Drug absorbance was measured using CCK-8 colorimetric assay and alkaline phosphatase assay to detect the effect of drug-loaded materials on the proliferation and differentiation of osteoblasts. RESULTS: After ZOL loading, SEM showed that porous calcium phosphate ceramic was coated with chitosan evenly. The IR spectra indicated that drug absorption peaks were shifted and a new one was formed for the drug-loaded biomaterials. The material at the highest concentration could inhibit the proliferation and alkaline phosphatase activities of osteoblast cells, but no such effect was found at a drug-loading concentration of 10(-4)-10(-5) mol/L. CONCLUSION: We confirmed that the local delivery system in this study has ability of loading ZOL. The biomaterial with high drug concentrations inhibits the proliferation and differentiation of osteoblasts, but not when the drug concentrations are low.


Assuntos
Fosfatos de Cálcio/química , Diferenciação Celular/efeitos dos fármacos , Quitosana/química , Difosfonatos/farmacologia , Portadores de Fármacos/química , Imidazóis/farmacologia , Osteoblastos/efeitos dos fármacos , Animais , Animais Recém-Nascidos , Fosfatos de Cálcio/administração & dosagem , Proliferação de Células , Células Cultivadas , Cerâmica/química , Quitosana/administração & dosagem , Portadores de Fármacos/administração & dosagem , Feminino , Masculino , Osteoblastos/citologia , Osteoblastos/metabolismo , Ratos , Ratos Sprague-Dawley , Ácido Zoledrônico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA